SOLAR POWERED WIND & LIGHT SENSOR AUTOMATE | Wind-Light sensor is a device for measuring wind speed and light intensity. The information is transmitted to ARC outdoor motorized shades that will move to their top or bottom limits. FEATURES:
Measure wind speed with an anemometer Measure light intensity with a Lux meter LCD display ARC compatibility USB-C Charging Port Solar Charging Panel Loss of communication Safeguard Technology MT02-0301-072001_PRGM_v2.3_MAR 2022 SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturers liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not submerge in water or expose to extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. Statement Regarding FCC Compliance For use with motorized shading devices. Keep away from children. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep clear when in operation. Replace battery with correctly specified type. Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of R&TTE Directive 2014/53/EU This device complies with Part 15 of the FCC Rules / Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage; 2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 2 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 1 STATIC TITLE CONTENTS 1 2 INSTALLATION OVERVIEW 2.1 Components 2.2 LCD Display 2.3 Safeguard Technology 3 SETUP 3.1 Pair the motor to a remote (if required) 3.2 Check motor Direction 3.3 Pair or Unapir the Sensor to a Motor using a Pre-Paired Remote 3.4 Setup wind speed control 3.5 Setup light control 4 ADDITIONAL FUNCTIONS 4.1 Display measured wind speed & light intensity 4.2 Display the pre-set threshold value 4.3 Wind Sensor Function 4.4 Light Sensor Function 4.5 Activate/Deactivate Sun & Wind sensor functionality on the motor 5 6 TROUBLESHOOTING NOTES 4 5 5 6 6 7 7 7 8 8 9 10 10 10 11 11 12 13 14 ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 3 1 STATIC TITLE 1 INSTALLATION 1. Find an appropriate location with direct sunlight and in a location that will see the same wind conditions the paired device will see. 2. Remove the base covers 3. 4. The solar panel must be face up and in direct sunlight Fix the sensor to a suitable surface 5. Re-attach the base covers 6. Ensure the three rotating cups are in an approximately horizontal position Transmission Distance:
35 meters indoors 200 meters open space 4 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 2 OVERVIEW 2.1 COMPONENTS Anemometer cup Luminosity Sensor Display Menu Up Factory Reset Button Adjust P2 Solar Panel USB-C Charging Port ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 5 2.2 LCD DISPLAY LIGHT 433MHz RF SIGNAL BATTERY WIND LOOP VALUE WIND SPEED UNIT LIGHT UNIT 1. 2. 3. The LCD screen lighting stays active for 30 seconds. If there is no operation, the sensor automatically switches its screen off for energy saving, but the program will keep running for normal detection and command transmissions. When the screen is off, pressing any (non-reset) button triggers the screen to be on again for another minute. Sun icon: indicates the light intensity detection mode. Flag icon: indicates the wind speed detection mode. 4. Battery icon: The voltage of the internal battery is checked by its inner program once every day. The appearance of this battery icon indicates that its voltage is below 2.7V. It is recommend that the sensor is placed in direct sunlight or plug in a USB-C cable to charge the sensor for minimum of 6 hours. 5. RF signal icon: displayed when transmitting a signal. 2.3 SAFEGUARD TECHNOLOGY Once the sensor is paired to an Automate external motor, the sensor will check in with the motor every 30mins. If the motor does not receive the signal at the checkpoint, the motor will close as a protective measure. Once the Safeguard feature has been triggered, motor will only move in small increments. This is a sign that there is a fault in the sensor or that the internal battery has gone flat. If this happens, you will need to place the sensor in direct sunlight or plug in a USB-C cable to charge the sensor for minimum of 6 hours. 6 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 3 SETUP 3.1 PAIR THE MOTOR TO A REMOTE (IF REQUIRED) Hold P1 button on motor head. Hold STOP on controller to add or remove. AU FT motor head US FT motor head Motor Response Motor Response Approx. NOTE:
Complete setup using motor programming instructions. The sensor will only work if the motor is configured with the upper and bottom limits. 3.2 CHECK MOTOR DIRECTION Confirm that motor direction is setup as below so any paired sensors will activate correctly. DOWN on the remote OPENS the Awning (awning moves in an outward/downward direction). E.g. And UP on the remote CLOSES the Awning (awning moves in an inward/upward direction). E.g. Note: Follow motor programming instructions to reverse motor direction if necessary. ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 7 3.3 PAIR OR UNAPIR THE SENSOR TO A MOTOR USING A PRE-PAIRED REMOTE Press P2 on controller Press P2 on controller Press P2 to wake the sensor if required Press P2 on the sensor to add or remove it M A M A M A M A M A UP P2 UP P2 UP P2 UP P2 UP P2 Motor Response Motor Response Motor Response NOTE:
If the pair is successfully done, the motor can be triggered to move upward by pressing the UP button on the sensor. Ensure the wind and light sensor functionality on the motor is enabled prior to pairing the wind and sun sensor. The pair relationship is kept even if the motor power is reset or the sensor is reset to its default setting. 3.4 SETUP WIND SPEED CONTROL Press & Hold M button for 2 seconds until screen flashes Cycle though settings till you have the Wind icon( ) by pressing M Adjust the pre-set threshold by pressing UP to increase value or A to decrease value Approx. M A M A M A M A M A M A M A M A M A M A M A M A M A M A M A UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 NOTE: The wind speed control function can be disabled by setting its threshold to ZERO. Other threshold values enable this function. Approx. 10 Wait 10 seconds to set the threshold 8 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 3.5 SETUP LIGHT CONTROL Press & Hold M button for 2 seconds until screen flashes Cycle though settings till you have the Sun icon( ) by pressing M Adjust the pre-set threshold by pressing UP to increase value or A to decrease value Approx. M A M A M A M A M A M A M A M A M A M A M A M A M A M A M A UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 NOTE: The light intensity function can be disabled by setting its threshold to ZERO. Other threshold values enable this function. Approx. 10 Wait 10 seconds to set the threshold Condition Direct Sunlight Daylight Overcast klux (approximate) 100 10 1 ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 9 4 ADDITIONAL FUNCTIONS 4.1 DISPLAY MEASURED WIND SPEED & LIGHT INTENSITY In the sleep mode (blank screen), pressing the Adjust button (A) can loop through light intensity or wind speed. When the loop icon, , is present, the system will automatically display them in a cycle (5 seconds). The sequence is light > wind > loop (light). Press A button Press A button M A M A M A M A M A M A M A M A M A M A UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 4.2 DISPLAY THE PRE-SET THRESHOLD VALUE Press the MENU button (M) repeatedly to display the pre-set threshold values in a cycle, the corresponding icon, , flashes to indicate that the pre-setting value is displayed. Pressing the MENU button (M) again returns to the normal mode. The sequence is: display the light intensity threshold value > display the wind speed threshold value > return to normal mode. Press M button Press M button M A M A M A M A M A M A M A M A M A M A UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 UP P2 10 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 4.3 WIND SENSOR FUNCTION Wind speed continuously exceeds the threshold value of wind speed for longer than 3 seconds The sensor command is executed to control the motor UP action 3 To prevent the motorized shades from frequently opening and closing under a gust, the motor does not operate for next 8 minutes 8 MINS 4.4 LIGHT SENSOR FUNCTION When the environmental light intensity is higher than the threshold for 15 minutes The sensor command is executed to control the motor DOWN action 15 MINS When the environmental light intensity is lower than the threshold for 15 minutes The sensor command is executed to control the motor UP action 15 MINS After this period, the sensor temporarily disables its light detection for the next 15 minutes 15 MINS After this period, the sensor temporarily disables its light detection for the next 15 minutes 15 MINS NOTE :
Wind sensor trigger overrides light sensor, and moves motor up to top limit, despite motor having moved down due to strong light. ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 11 4.5 ACTIVATE/DEACTIVATE SUN & WIND SENSOR FUNCTIONALITY ON THE MOTOR Note: Functionality activated by default. Press P2 on controller Press UP on controller Press STOP on controller Motor Response Motor Response Motor Response (Activated) Motor Response (Deactivated) 12 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 5 TROUBLESHOOTING Problem Cause Remedy Motor is not responding Motor extends then constantly retracts unexpectedly Sensor battery is discharged Recharge battery with a USB cable Radio interference/Shielding Ensure transmitter is positioned away from metal objects and that the motor aerial/receiver is kept straight and away from metal Receiver distance is too far from transmitter Move transmitter to a closer position Power failure Incorrect wiring Pairing error Check the connection from power supply to motor Check if wiring is connected correctly Press UP button on sensor to verify pairing The motors function of detecting wind/light is off Turn on the function Wind or light threshold is too low Increase the threshold to reduce sensitivity Extend motorized shade is casting shadow onto sensor Check & reposition sensor if necessary Wind sensitivity is too high or too low Adjust sensitivity Motor does not react to wind or light setting Time interval of strong wind is less than 8 minutes The wind triggering time length must be over 8 minutes Time interval of light is less than 15 minutes The light triggering time length must be over 15 minutes Screen not turning on Internal Battery Flat Motor is only moving in small increments (after motor setup has been completed) Safeguard feature Motor retracted and not operating
(not getting stepping mode function) Wind Sensor has been triggered Safeguard feature is not triggering Motor and Wind sensor checking timing Place sensor in direct sunlight or plug in the USB-C connection to charge sensor for minimum of 6 hours. Communication between motor and sensor has been lost. Replace the 2 x alkaline batteries and check motion sensor is working correctly. Once the Wind sensor has been triggered there is an 8min lockout as a protective measure. Motor and Wind sensor need to have at least 1 check in before this feature is enabled, this occurs every 30mins. ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 13 6 NOTES 14 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA 1 STATIC TITLE 6 NOTES ROLLEASE ACMEDA Automate Programming Instructions | MT02-0301-072001 | 15 1 STATIC TITLE ROLLEASE ACMEDA | USA Level 7 / 750 East Main Street Stamford, CT 06902, USA ROLLEASE ACMEDA | AUSTRALIA ROLLEASE ACMEDA | EUROPE 110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +1 800 552 5100 | F +1 203 964 0513 T +61 3 9355 0100 | F +61 3 9355 0110 T +39 02 8982 7317 | F +39 02 8982 7317 16 | Automate Programming Instructions | MT02-0301-072001 ROLLEASE ACMEDA