AUTOMATE Paradigm Flush Wall Switch 433 MHz AUTOMATE | Paradigm flush wall switches feature a contemporary design and a wirefree deployment, making them retrofit ready for any location. Paradigm 5 channel switches are perfect for individual shade, room and whole home control. The Paradigm flush mount switch can be mounted on top of any surface. Its slim profile eliminates the need for any holes to be cut in walls. FEATURES:
Multi channel selectable Retrofit Ready Group Control Compatible with screwless decorator cover plates Optionally functions as handheld remote 8 1 0 2 B E F 3
. 1 v _ M G R P _ H S U L F
-
5 S W
-
F R T M CONTENTS 1 2 3 TECHNICAL DATA / PACK CONTENTS SAFETY INSTALLATION Install switch batteries 3.1 Kit Components 3.2 3.3 Magnetic Wall Clip 3.4 Fixed Wall Clip 4 FUNCTIONAL OVERVIEW 4.1 Buttons 4.2 Selecting a channel 5 PROGRAMMING 5.1 Using the P1 button 5.2 Using a pre-existing controller 6 INITIAL SETUP 6.1 Check motor direction 6.2 Set limits 6.3 Locking the limit setting function 7 ADJUSTING LIMITS 7.1 Adjusting upper limit 7.2 Adjusting lower limit 8 FAVORITE POSITIONING 8.1 Set a favorite position 8.2 Send shade to favorite position 8.3 Delete favorite position 9 TROUBLESHOOTING 3 4 5 5 5 6 6 7 7 7 8 8 9 10 10 10 11 12 12 12 13 13 13 13 14 2 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 1 TECHNICAL DATA / PACK CONTENTS TECHNICAL SPECIFICATIONS Voltage:
Frequency:
Transmitting Power:
Ambient Operating Temperature:
3V (CR2430) 433.92 MHz 10 milliwatt
-10C -50C Transmission Distance:
up to 200 meters (open space) ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 3 2 SAFETY WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturers liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not expose to water, moisture, humid and damp environments or extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. For use with motorized shading devices. Keep away from children. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep clear when in operation. Replace battery with correctly specified type. Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of R&TT EC Directive 1999/5/EC This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 5005833 4 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 3 INSTALLATION 3.1 Kit Components 1. 2. 3. 4. 5. 6. 7. 8. 1 x Cover 1 x Switch Remote 1 x Magnetic Wall Clip 1 x Fixed Wall Clip 2 x Pan Head Screw 2 x Phillips Head Screw 2 x Wall Plug 3V - CR2430 Battery 9. Programming Manual 5. 1. 2. 8. 6. 3. 7. 4. 3.2 Install switch batteries Open rear battery cover by gently separating switch covers with a screwdriver Install CR2430 battery with positive side facing up. Snap covers back together. Snap covers back together. ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 5 3.3 Magnetic Wall Clip Use the Magnetic Wall Clip if you require the remote to be easily detachable. Best Practice Tip:
Program the Switch to the motor prior to installation, then test radio performance in the location the switch will be installed in, to ensure best performance. Use supplied fasteners and anchors as needed to attach the base and cover. Switch is held in position magnetically and can be removed as desired. Safely dispose of the unused Fixed Wall Clip. 3.4 Fixed Wall Clip Use the Fixed Wall Clip if you require the remote to be non-removable. Best Practice Tip:
Program the Switch to the motor prior to installation, then test radio performance in the location the switch will be installed in, to ensure best performance. Slide the Switch onto the Wall Clip. Use supplied fasteners and anchors as needed to attach the base and cover. Switch is secured unless the Cover is removed. Safely dispose of the unused Magnetic Wall Clip. 6 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 4 FUNCTIONAL OVERVIEW 4.1 Buttons CHANNELS 1-5 STOP P2 UP DOWN 4.2 Selecting a channel Press desired channel button(s) To deselect channel, press channel button until LED turns off Motor Response Blue LEDs will illuminate indicating channel selection. IMPORTANT Switch requires that at least one channel be selected at all times. First select an additional channel, then deselect channel you don't want to operate. ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 7 5 PROGRAMMING 5.1 Using motor P1 button IMPORTANT Multiple motors can be grouped onto shared channels for co-ordinated control. Limit settings and favorite positions cannot be adjusted when motors are grouped together. Confirm that motor limits and favorite position are already set for each individual motor. Ensure that each motor you want to group is also assigned to another channel by itself Select a channel on switch. Hold P1 button on motor head. Hold STOP on switch. Motor Response Motor Response RELEASE P1 Approx. Approx. 8 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 5.2 Using pre-existing controller A = Existing switch or channel (to keep) B = Switch or channel to add or remove Select channel that operates motor on existing switch. Press P2 Press P2 a second time on existing switch. Select desired channel on new switch. Press P2 on new switch. Motor response Motor response Motor response ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 9 6 INITIAL SET UP 6.1 Check motor direction To check travel direction of shade, press UP or DOWN on controller. Quick Press = Step Long Press = Continuous Travel IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. 6.2 Set Limits To reverse shade direction, hold both UP and DOWN. Until the motor responds. Motor Response Approx. IMPORTANT Reversing motor direction using this method is only possible during initial set-up Direction change will not occur if switch is locked. See Section 6.3. To save upper limit, hold UP and STOP. Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save lower limit, hold DOWN and STOP. IMPORTANT Cycle shade up and down prior to setting limits to settle fabric Initial set-up is not complete Motor Response Approx. 5 SECS IMPORTANT IMPORTANT For FT Motors, the bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised. After setting limits, motor will automatically exit from initial set-up mode. 10 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 6.3 Locking the limit setting function Stops unwanted changes to limit settings Press STOP and hold for 15 seconds Press STOP and hold for 15 seconds Release STOP button. Locked limit settings Release STOP button. Unlocked limit settings Remote Response Remote Response Approx. 5 All lights flash x 1 IMPORTANT Approx. 5 All lights flash x 2 The locked setting will prevent any multi-button functions. These include reversing direction before setting limits, limit setting and toggling between tilt and roller modes. ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 11 7 ADJUSTING LIMITS 7.1 Adjust upper limit Hold UP and STOP on controller. Move shade to the desired highest position by pressing the UP button. To save upper limit, hold UP and STOP. Motor Response Approx. 5 SEC S 7.2 Adjust lower limit Motor Response Approx. 5 SEC S Hold DOWN and STOP on controller. Move shade to the desired lowest position by pressing the DOWN button. To save lower limit, hold DOWN and STOP. Motor Response Approx. 5 SEC S IMPORTANT Motor Response Approx. 5 SEC S For FT Motors, the bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised. 12 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA 8 FAVORITE POSITIONING 8.1 Set a favorite position Move shade to the desired position by pressing the UP or DOWN button on the controller. Press P2 on controller. Press STOP on controller. Press STOP on controller. P2 Motor Response Motor Response Motor Response UP DOWN 8.2 Send shade to favorite position Approx. 8.3 Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. P2 Motor Response UP DOWN Motor Response Motor Response ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 13 9 TROUBLE SHOOTING Problem Cause Remedy Switch battery is discharged Replace battery Battery is inserted incorrectly Check battery polarity Radio interference / Shielding Motor is not responding Receiver distance is too far from remote Power failure Incorrect motor wiring Cannot set limits on a single motor (multiple motors respond) Using channel 0 to adjust motor limits
(Multi channel remote ONLY) Motor will not go down after setting the top limit. Top limit was set using the DOWN and STOP buttons. Motor will pair, but can not set limits. Switch is in a locked state. Control must be unlocked to set limits or perform any multi-button functions. Ensure remote is positioned away from metal objects and that aerial on motor or receiver is kept straight and away from metal. Move remote to a closer position or consider a repeater for improved performance. Check power supply to motor is connected and active. Check wiring is connected correctly
(refer to motor installation instructions). Always reserve an individual channel for programming functions. SYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi motor projects, that provides individual control for each motor for programming purposes. Reset the motor and begin programming sequence again. Remember that upper limit is to be set using the UP and STOP buttons, and the down limit is set using the DOWN and STOP buttons. Press and hold STOP button for 15 seconds, until locked state changes. 14 | Automate Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA NOTES ROLLEASE ACMEDA Automate Programming Instructions | Flush Wall Switch | 15 ROLLEASE ACMEDA USA 750 East Main Street, 7th Floor Stamford, CT 06902 T +1 203 964 1573 | F +1 203 358 5865 ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 | F +61 3 9355 0110 Queensland Branch Unit 2/62 Borthwick Avenue, Murarrie QLD 4172 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan
(Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 16 | Automate Programming Instructions | Flush Wall Switch