TDBU Programming Guide WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturer's liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not expose to water, moisture, humid and damp environments or extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. For use with motorized shading devices. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep clear when in operation. Replace battery with correctly specified type. WARNING: Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. Do not dispose of in general waste. FCC ID: 2AGGZ003B9ACA3E IC:
21769-003B9ACA3E Operation Temperature Range: -10C to +50C Ratings: 3VDC, 15mA FCC & ISED STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device contains licence-exempt transmitter(s)/receiv-
er(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1) Lappareil ne doit pas produire de brouillage;
2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. INSTALLER BEST PRACTICE AND TIPS SLEEP MODE PRODUCT RANGE P1 LOCATIONS This Quick Start Programming Guide is for the Top Down Bottom Up system (controller and remote). P1 Button 9-12 hours If pre-programmed: before shipping the motor ensure the motor is put into sleep mode so it doesnt activate during transit. Top Down Button Up System During operation, if the battery is low, the Endcap LED indicator will flash red to prompt the user to charge the system. LOCK REMOTE Prevent users accidently changing the limit;
ensure the remote is locked as your last step of programming. ZONE / GROUPS Ask the customer the day before to think how shades will be zoned on the remote. This may save an extra call out. SETTLE FABRIC Run the fabric up and down several times to ensure fabric has settled to some extent and re adjust the limits if needed. CHARGE 100%
For battery motors ensure the motor is fully charged as per instructions. INSTALLERS REMOTE Use a spare remote to individually program each shade. Then use that remote to group rooms as per the users needs. If you go back and service the installation later then, that same remote can be used to check the individual shades. LED 5V USB Charging port RF Controller Blinking Red Blinking Green Solid Green LED Status:
Motor 1 Connection Port Motor 2 Connection Port Switch Charging Port P1 Button Low battery alert Charging in process Battery has finished charging USB Cable Note:
There are 2 different End Caps:
1. Left End Cap 2. Right End Cap USB Power Supply INS QUICK START TALLER PROGRAMMING STEP 3 CHECK DIRECTION This setup wizard sho uld be used for new installation or fa Individual steps may not work if you haven't followed the w ctory reset motors only. izard from the beginning. STEP 1 ON REMOTE STEP 2 PAIRING REMOTE WITH MOTOR STEP 5 SET UPPER LIMIT STEP 6 SET BOTTOM LIMIT STEP 7 SAVE YOUR LIMIT 15 2 SECS Press the P1 button on the motor for 2 Seconds until the motor responds The motor will respond with Jog x1 Within 10 seconds hold the Left STOP button on the remote until the motor Jogs x2:
r a b m e H r e w o L OR r a b m e H e l d d M i Press >< (Up) or <> (Down) to check the motor direction. If correct skip to step 5. STEP 4 CHANGE DIRECTION If the shade direction needs to be reversed;
press and hold the >< (Up) & <> (Down) buttons together for 2 seconds until the motor Jog x1. 2 SECS
P1 E S N O P S E R R O T O M Move the middle hembar to the desired top limit by pressing the right
>< (Up) button repeatedly. Move the middle hembar to the desired bottom limit by pressing the right <> (Down) button repeatedly. Lock Button P1 Then press and hold right >< (Up) &
right STOP buttons together for 2 seconds to save the top limit. Then press and hold right <> (Down) &
right STOP buttons together for 2 seconds to save the bottom limit. Repeat steps 1-6 for all motors. Once complete Press the lock button for 5 seconds to lock the remote, the L will breifly appear on the screen.
2 SECS E S N O P S E R R O T O M JOG x2
2 SECS E S N O P S E R R O T O M JOG x2 6 SECS L OR Press (lower channel) or
(higher channel) buttons to select the channel that needs to be programmed JOG x2 E S N O P S E R R O T O M JOG x1 The operation is only valid when there are no limits. Repeat this process using the left ><
(Up) button to set desired top limit and left >< (Up) & left STOP for 2 seconds to set the lower hembar top limit. Repeat this process using the left <>
(Down) button to set desired bottom limit and left <> (Down) & left STOP for 2 seconds to set the lower hembar top limit. FACTORY RESET MOTOR RESET PROCEDURE To reset all settings in the motor press and hold the P1 Button for 14 seconds, you should see 4 independent jogs. 14 SECS MOTOR RESPONSE 2 SECS 6 SECS 10 SECS 14 SECS E S N O P S E R R O T O M JOG x4 I E D U G R E S U I E D U G R E S U I E D U G T R A T S K C U Q I I G N M M A R G O R P D E C N A V D A BUTTON OVERVIEW REPLACE BATTERY WALL MOUNTING SELECTING A CHANNEL GROUP CONTROL Left Up Left Stop Left Down Lower Channel Remove Battery Isolation Tab LCD Display Battery Right Up Right Stop Right Down Higher Channel Isolation Tab Note:
On Startup, Remove Battery isolation tab. Remove cover Use a tool (such as a SIM card pin, mini screwdriver, etc.) to push the battery cover release button and simultaneously slide the battery cover down. Install Battery Remote STEP 1 OR Press left and right arrow; to scroll through channels as required. STEP 2 READY FOR CONTROL Now while the channel is active follow the control instructions. Use supplied fasteners and anchors to attach the base to wall. HIDE UNUSED CHANNELS Your multi channel remote can be configured to have anywhere between 1 or 15 visible channels. Inactive channels will not be visible when scrolling through the Channel selection. Hold STOP and Channel Button Remote Respose: Flashing Stops Continue holding Channel Button and select required channel qty by pressing
>< (UP) or <> (Down)
OR P2 P2 Li-ion Cell Battery
(CR2450)
Middle Hembar Lower Hembar Press STOP to confirm Note: Tools are not provided with the remote. Remote Respose: Flashing Stops If no button is pressed within 4 seconds, the channel slection will automatically be confirmed. Channel "0" is pre-set to control ALL shades paired to your Muli-channel remote. Lower Hembar Up CONTROLLING A SHADE CONTROL SHADE UP OR DOWN 0 Middle Hembar OR Down Up OR Down While the channel is displayed press >< (Up) or <> (Down) to move shade accordingly STOPPING THE SHADE Lower Hembar Middle Hembar Press the corresponding STOP button to stop the hembar at any point. Press and hold Left STOP for 2 seconds to send shade to favorite position (if set). DISABLE LIMIT SETTING This mode is intended to be used after all shade programming is completed. User Mode will prevent accidental or unintended changing of limits. Press the lock button for 5 seconds to lock/unlock the remote. Lock Button LCD displays L when locked L U LCD displays U when unlocked SET A FAVORITE POSITION Repeating these steps after creating a favorite position will delete it. STEP 2. Press Left STOP on controller CREATE CUSTOM GROUPS It is possible to copy one channel to another channel to create custom groups STEP 2. Press P2 again on existing controller Move Hembar to desired position by pressing >< (Up) or <> (Down) on the remote. 2 SECS r a b m e H r e w o L OR r a b m e H e l d d M i Move shade to desired position by adjusting hembar positions by pressing the corresponding
>< (Up) and <> (Down) buttons on the remote. STEP 1. Press P2 on controller 5 5 Select the channel you want to transfer STEP 1. Press P2 on existing controller E S N O P S E R R O T O M JOG x1 Select the channel on the new controller STEP 3. Press P2 on new controller P2 STEP 3. Press Left STOP on controller 2 SECS P2 P2 Step 3 to be completed within 4 seconds of Step 2 E S N O P S E R R O T O M JOG x1 E S N O P S E R R O T O M JOG x1 E S N O P S E R R O T O M JOG x2 E S N O P S E R R O T O M E S N O P S E R R O T O M JOG x1 JOG x2