AUTOMATE V2 MOTOR PROGRAMMING INSTRUCTIONS SOFT STOP Soft Stop ELECTRONIC Battery Check USB Charge SELECTABLE 433 MHZ LIMIT SPEED BI-DIRECTIONAL Soft Stop Soft Stop FAVORITE POSITION Battery Check Battery Check BATTERY CHECK USB Charge USB Charge USB CHARGE SOLAR OPTION LEVEL CONTROL BATTERY POWERED USE THIS DOCUMENT WITH THE FOLLOWING MOTORS:
PART NUMBER DESCRIPTION MT01-1325-069001 AUTOMATE | Li-ion 1.1Nm ARC Motor [25/5V/20rpm] (Skyline Short) MT01-1325-069002 AUTOMATE | Li-ion 1.1Nm ARC Motor [25/5V/20rpm] (Skyline) MT01-1325-069003 AUTOMATE | Li-ion 1.1Nm ARC Motor [25/5V/20rpm] (S45) MT01-1325-069005 AUTOMATE | Li-ion 1.1Nm ARC Motor [25/5V/20rpm] (S45 Short) MT01-1328-069001 AUTOMATE | Li-ion 2.0Nm ARC Motor [28/5V/20rpm] (Skyline) MT01-1328-069002 AUTOMATE | Li-ion 2.0Nm ARC Motor [28/5V/20rpm] (S45) MT01-1335-069001 AUTOMATE | Li-ion 3.0Nm ARC Motor [35/5V/20rpm]
MT01-1345-069001 AUTOMATE | Li-ion Q3.0Nm ARC Motor [45/5V/20rpm]
MT01-1345-069002 AUTOMATE | Li-ion 10.0Nm ARC Motor [45/5V/9rpm]
AUTOMATE V2_PRGM_JANUARY_2020 SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturers liability and warranty. WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturers liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not expose to water, moisture, humid and damp environments or extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. For use with motorized shading devices. Keep away from children. Keep clear when in operation. Replace battery with correctly specified type. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of RED \ Directive 2014/53/EU Statement Regarding FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Statement Regarding IC Compliance 1. This device complies with Industry Canada RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.
-French:
Leprsent appareil est conforme aux CNR dIndustrie Canada applicable aux appareils radio Exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, meme si le brouillage est susceptible den compromettre le fonctionnement. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. CAN ICES-3 (B)/NMB-3(B) Consult the dealer or an experienced radio/TV technician for help. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 2 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 11 SOFT STOP CONFIGURATION 11.1 Turn Soft Stop OFF 11.2 Turn Soft Stop ON 12 BATTERY CHECK FUNCTION 12.1 Send Shade to battery charge level 13 CHARGING LED 13.1 Turn Charging LED ON/OFF 14 SLEEP MODE 15 TROUBLE SHOOTING 14 14 14 15 15 15 15 16 16 CONTENTS ASSEMBLY 1 2 3 4 RETROFIT INSTALLATION CHARGING P1 BUTTON FUNCTIONS 4.1 Motor state test 4.2 Motor configuration options 5 INITIAL SET UP 5.1 Pair motor with controller 5.2 Check motor direction 5.3 Set Limits 6 ADJUSTING LIMITS 6.1 Adjust upper limit 6.2 Adjust lower limit 7 CONTROLLERS AND CHANNELS 10 7.1 Using P2 Button on existing controller to add a new controller or channel 10 7.2 Using a pre-existing controller to add or delete a controller or channel 10 8 FAVORITE POSITIONING 8.1 Set a favorite position 8.2 Send shade to favorite position 8.3 Delete favorite position 9 TILT & ROLLER MODE 9.1 Toggle motor to Tilt Mode 9.2 Toggle Motor to Roller Mode 10 ADJUSTING SPEED 10.1 Increase Motor Speed 10.2 Decrease Motor Speed 4 5 5 6 6 6 7 7 7 8 9 9 9 11 11 11 11 12 12 12 13 13 13 ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 3 1 ASSEMBLY 4 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 2 RETROFIT INSTALLATION 3 CHARGING ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 5 4 P1 BUTTON FUNCTIONS 4.1 Motor state test This table describes the function of a short P1 Button press/release (<2 seconds) depending on current motor configuration. P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described If limit is NOT set None No Action None No Action Short Press Operational control of motor, run to limit. Stop if running If limits are set Motor Runs None Sleep Mode &
Wake and control None If motor is in limits are set Motor wakes and runs in a direction Operational control of motor after pairing and limit setting is completed first time Motor is restored from Sleep Mode and RF control is active 4.2 Motor configuration options The P1 Button is utilized to administer motor configurations as described below. Hold P1 button on motor head. Activate Pairing Mode Approx. Sleep Mode Approx. Approx. Reverse Direction Approx. Approx. Approx. 10 Reset To Factory Settings Approx. Approx. Approx. 10 Approx. P1 button on motor head. 6 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 5 INITIAL SET UP 5.1 Pair motor with controller Select channel on controller. Hold P1 button on motor head. Hold STOP on controller. IMPORTANT Consult user manual for your controller for information on selecting channel. Motor Response Motor Response Approx. Motor is now in step mode and ready for setting limits 5.2 Check motor direction To check travel direction of shade, press UP or To reverse shade direction, hold both UP and DOWN on controller. DOWN. Until the motor responds. OR Quick Press = Step Long Press = Continuous Travel Motor Response Approx. IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. IMPORTANT Reversing motor direction using this method is only possible during initial set-up ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 7 5.3 Set Limits IMPORTANT Cycle shade up and down prior to setting limits to settle fabric Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save upper limit, hold UP and STOP. Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save lower limit, hold DOWN and STOP. OR OR Motor Response Approx. 5 SEC S Motor Response Approx. 5 SEC S IMPORTANT After setting limits, motor will automatically exit from initial set-up mode. 8 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA Hold UP and STOP on controller. Move shade to the desired highest position by pressing the UP or DOWN button. To save upper limit, hold UP and STOP. 6 ADJUSTING LIMITS 6.1 Adjust upper limit Motor Response Approx. 5 SEC S 6.2 Adjust lower limit Motor Response Approx. 5 SEC S IMPORTANT OR OR Motor Response Approx. 5 SEC S Motor Response Approx. 5 SEC S Hold DOWN and STOP on controller. Move shade to the desired lowest position by pressing the UP or DOWN button. To save lower limit, hold DOWN and STOP. The bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised. ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 9 7 CONTROLLERS AND CHANNELS 7.1 Using P2 Button on existing controller to add a new controller or channel A = Existing controller or channel (to keep) B = Controller or channel to add or remove Press P2 on controller A. Press P2 on controller A. Press STOP on an new controller to add it. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor 7.2 Using a pre-existing controller to add or delete a controller or channel A = Existing controller or channel (to keep) B = Controller or channel to add or remove Press P2 on controller A. Press P2 on controller A. Press P2 on the controller B to remove it. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor 10 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 8 FAVORITE POSITIONING 8.1 Set a favorite position Move shade to the desired position by pressing the UP or DOWN button on the controller. Press P2 on controller. Press STOP on controller. Press STOP on controller. OR Motor Response Motor Response Motor Response 8.2 Send shade to favorite position Approx. 8.3 Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 11 9 TILT & ROLLER MODE 9.1 Toggle motor to Tilt Mode Default motor mode is Roller after initial Limits have been set, use following steps to change to Roller Mode. Hold UP & DOWN on controller. Press STOP on controller. Motor Response Motor Response Approx. 5 SEC S 9.2 Toggle Motor to Roller Mode If motor is in Tilt Mode, use following steps to change to Roller Mode. Hold UP & DOWN on controller. Press STOP on controller. Motor Response Motor Response Approx. 5 SEC S 12 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 10 ADJUSTING SPEED 10.1 Increase Motor Speed Default motor mode is the slowest speed. Press P2 Press UP Press UP Motor Response Motor Response Motor Response 10.2 Decrease Motor Speed Press P2 Press DOWN Press DOWN Motor Response Motor Response Motor Response ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 13 11 SOFT STOP CONFIGURATION 11.1 Turn Soft Stop OFF Motor must be in slowest speed to turn Soft Stop OFF. Press P2 Press DOWN Press DOWN Motor Response Motor Response Motor Response 11.2 Turn Soft Stop ON Motor must be in fastest speed to turn Soft Stop ON. Press P2 Press UP Press UP Motor Response Motor Response Motor Response 14 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA 12 BATTERY CHECK FUNCTION 12.1 Send Shade to battery charge level Shade must be at Upper Limit. Hold UP Upper Limit Percentage of Battery Charge Remaining Lower Limit Percentage Depleted Motor Response Approx. SEC5 Shade must be at Upper Limit Shade moves to percentage of Hold UP for Approx. 5s battery charge remaining 13 CHARGING LED 13.1 Turn Charging LED ON/OFF Motor must be at Lower Limit. Hold DOWN to toggle off Hold DOWN to toggle on Motor Response Motor Response Approx. 5 SEC S Red LED flashes x3 Approx. 5 SEC S Red LED flashes x3 ROLLEASE ACMEDA Automate Programming Instructions | Li-ion Tubular Motors | 15 If multiple motors are grouped on a single channel, Sleep Mode may be used to put all but 1 motor to sleep, allowing programming of just the one motor that remains Awake. See page 6 for detailed P1 functions. Exit Sleep Mode: Method 1 Exit Sleep Mode: Method 2 Exit sleep mode once the shade Remove power and then is ready. re-power the motor. Press and release P1 button on the motor head 14 SLEEP MODE 9 SLEEP MODE Enter Sleep Mode Sleep mode is utilized to prevent a motor from incorrect configuration during other motor setup. Hold P1 button on the motor head Motor Response Motor Response Approx. G 15 TROUBLE SHOOTING rolleaseacmeda.com Problem Cause Remedy Motor is not responding Battery in motor is depleted Recharge with a compatible charger Insufficient charging from solar PV panel Check connection and orientation of PV panel Transmitter battery is discharged Replace battery Battery is inserted incorrectly into transmitter Radio interference/shielding Receiver distance is too far from transmitter Move transmitter to a closer position Charging failure Check battery polarity Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal Check power supply to motor is connected and active Recharge with a compatible charger Always reserve an individual channel for programming functions. Use Sleep Mode to program individual motors. Motor beeps x10 when in use Battery voltage is low Cannot program a single motor
(multiple motors respond) Multiple motors are paired to the same channel ROLLEASE ACMEDA | USA Level 7 / 750 East Main Street Stamford, CT 06902, USA ROLLEASE ACMEDA | AUSTRALIA ROLLEASE ACMEDA | EUROPE 110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +1 800 552 5100 | F +1 203 964 0513 T +61 3 9355 0100 | F +61 3 9355 0110 T +39 02 8982 7317 | F +39 02 8982 7317 16 | Automate Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA