EMR303 Integration Guide Emerson EMR303 Bluetooth Low Energy Module Integration Guidance Revision A2 18 December 2023 Page | 1 EMR303 Integration Guide Contents 1 Purpose ...............................................................................................................................3 2 General Information .............................................................................................................3 2.1 Product Description .......................................................................................................3 3 Specifications .......................................................................................................................3 3.1 Normal Operating Conditions ........................................................................................3 3.2 Electrical Specifications ................................................................................................3 3.3 Radio Specifications .....................................................................................................3 4 Antenna Specifications.........................................................................................................4 5 Installation Guidelines ..........................................................................................................4 5.1 Spectrum Approval Test Modes ....................................................................................4 5.1.1 Bluetooth Tests ......................................................................................................4 6 Regulatory and Standards Compliance ................................................................................5 6.1 FCC Compliance Testing ..............................................................................................5 6.1.1 FCC Labeling Requirements ..................................................................................5 6.1.2 FCC Documentation Requirements .......................................................................6 6.2 ISED Compliance Testing .............................................................................................6 6.2.1 ISED Labeling Requirements .................................................................................6 6.2.2 ISED Documentation Requirements ......................................................................6 6.3 EU Compliance .............................................................................................................7 7 RF Exposure Considerations ...............................................................................................7 Page | 2 EMR303 Integration Guide 1 Purpose This document serves as a guide for integrating the EMR303 BLE module into Emerson products for a complete Bluetooth solution. 2 General Information 2.1 Product Description The BLE module has been designed to be fully compliant with Bluetooth Low Energy Core Specification 5.2. It operates in the 2.4GHz ISM frequency band and is expected to operate to a minimum distance of 50ft line of sight. 3 Specifications 3.1 Normal Operating Conditions Operating supply voltage Operating temperature range Peak supply current Min Typ Max Units 3.8 VDC 1.9 C 85
-40 3.3 Comments 7 10.7 19.3 mA mA mA 25C, 3VDC, Advertising mode 25C, 3VDC, 2M constant TX 85C, 1.85VDC, 2M constant TX 3.2 Electrical Specifications Parameter Test Conditions Min Typ Max Units VIH VIL TA = 25C, VDDS = 3.8V 0.8*VDDS TA = 25C, VDDS = 3.8V 0.2*VDDS V V MHz MHz 3.75 12 SPI freq to main MCU SPI freq to external flash 3.3 Radio Specifications Operating frequency Number of channels Channel separation Occupied channel bandwidth Modulation Raw data rate Output power Min 2402 Typ Max Units 2480 MHz Comments Channel center 2442MHz 40 2 1.1 GFSK 5 1 MHz MHz 99% at 1Mbps IEEE 802.15.1 2 Mbps dBm Page | 3 EMR303 Integration Guide 4 Antenna Specifications The EMR303 module uses an on-board PCB trace antenna with a measured gain of less than
+3.0dBi.The antenna is permanently connected to the radio on the module. No other antennas are approved for use with this module. 5 Installation Guidelines The EMR303 radio module is only available for use in Emerson products. Host integrators must consult with the manufacturer for specific pinout assignments for data and power. Host integrators must perform required testing to ensure compliance with host product regulations. This section describes the test modes needed for spectrum approvals. To access these test modes, special host test firmware must be loaded. 5.1 Spectrum Approval Test Modes Spectrum approval test modes are accessed via serial commands using TIs BTool software. Btool version 1.42.19 must be used. UART connections are available on pins 5 and 6 of the module. USB to UART serial converters from FTDI are recommended (TTL-232RG). Be sure to choose the correct voltage cable that matches with your supply voltage to the BLE module. These test modes are not accessible by the general public. 5.1.1 Bluetooth Tests Radio testing for Bluetooth is performed as both radiated and/or conducted testing. The conducted tests require a Murata RF probe be connected to the BLE module (P/N MXHQ87WA3000) and routed to the labs test equipment. Transmit tests require the following BTool commands and runs at 100% duty cycle:
HCIExt_SetTxPowerCmd Set transmit power to +5dBm HCIExt_EnhancedModemTestTxCm Set PHY mode (1M or 2M) and RF channel to be tested. HCIExt_EndModemTestCmd Select this to change RF channels, PHY modes, or when the test is complete. Receive tests require the following BTool command:
Page | 4 HCIExtModemTestRxCmd Place the module into receive mode for Receiver Spurious Emissions. Select channel to be tested (usually channels 0 and 39). EMR303 Integration Guide 6 Regulatory and Standards Compliance The EMR303 allows modular host product integration in the United States, Canada, and European Union. The following guidance must be reviewed to ensure final compliance to regulatory standards. Host integrators must perform their own system level spectrum approval testing to ensure compliance with world area regulations. 6.1 FCC Compliance Testing The EMR303 radio module has demonstrated compliance to FCC 15.247. In order to fulfill FCC certification requirements, products incorporating the EMR303 must comply with the following:
1. An external label must be provided on the outside of the final product enclosure specifying the FCC identifier as described in below. a. Alternatively, if the device is always shipping with a graphical display, the business unit may incorporate an electronic label that incorporates the FCC identifier (according to e-labeling guidance per FCC KDB 784748 D02). 2. The system level device integrating the EMR303 must demonstrate compliance to FCC 15.247 requirements. a. The device integrating the EMR303 may not cause harmful interference, and must accept any interference received, including interference that may cause undesired operation. 3. An unintentional radiator scan must be performed on the device integrating the EMR303, per FCC rules and regulations, CFR Title 47, Part 15, Subpart B. See FCC rules for specifics on requirements for declaration of conformity. Reference KDB 996369 D04 Module Integration Guide v02 for detailed integration and testing guidance. 6.1.1 FCC Labeling Requirements The outside of the final product enclosure must have a label with the following (or similar) text specifying the FCC identifier. The FCC ID must be in Latin letters and Arabic numbers, 4pt or larger, and visible without magnification. Contains transmitter module FCC ID: LW2-EMR303 Or Contains FCC ID: LW2-EMR303 Page | 5 EMR303 Integration Guide 6.1.2 FCC Documentation Requirements User documentation must contain the following statements:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Changes or modification to the equipment not expressly approved by Emerson could void the user's authority to operate the equipment. 6.2 ISED Compliance Testing The EMR303 radio module has demonstrated compliance to ISED RSS-247. The system level device integrating the EMR303 must demonstrate compliance to RSS-247 requirements and must meet all applicable requirements in RSS-Gen, including the radio frequency exposure compliance requirements in RSS-102. 6.2.1 ISED Labeling Requirements The host product manufacturer must ensure that IC labeling requirements are met. The outside of the final product enclosure must have a label with the following (or similar) text specifying the IC identifier. Alternatively, if the device is always shipping with a graphical display, the business unit may incorporate an electronic label that incorporates the IC identifier (according to e-
labeling guidance in RSS-GEN, Annex B). The IC ID and certification code must be in Latin letters and Arabic numbers, 4pt or larger, and visible without magnification. Contains IC: 2731A-EMR303 6.2.2 ISED Documentation Requirements This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le present appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) Lappareil ne doit pas produire de brouillage;
Page | 6 EMR303 Integration Guide
(2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 6.3 EU Compliance The EMR303 radio module has demonstrated compliance as a module to the following standards:
EN 300 328 V2.2.2 EN 301 489-1 V2.2.2 EN 301 489-17 V3.2.4 EN 62311:2020 Host products are required to demonstrate compliance to the EU Radio Equipment Directive
(RED) 2014/53/EU and follow all documentation and labeling requirements. 7 RF Exposure Considerations The EMR303 module has demonstrated compliance to RF exposure limitations for FCC, ISED, and EU. The EMR303 must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. The EMR303 must be installed in accordance with manufacturers specifications. To be used in any other way than granted, requires additional evaluation and testing. Page | 7