Reference Manual 00809-0100-4075, Rev CA March 2014 Smart Wireless THUM Adapter Reference Manual 00809-0100-4075, Rev CA Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision 1 HART Device Revision 1 Field Communicator Field Device Revision Dev v2.5 DD v4 NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure to thoroughly understand the contents before installing, using, or maintaining this product. The United States has two toll-free assistance numbers and one international number. Customer Central 1 800 999 9307 (7:00 a.m. to 7:00 p.m. CST) National Response Center 1 800 654 7768 (24 hours a day) Equipment service needs International 1 952 906 8888 The products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate readings. For information on Rosemount nuclear-qualified products, contact an Emerson Process Management Sales Representative. Explosions could result in death or serious injury:
Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Product Certifications section for any restrictions associated with a safe installation. Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices.
Electrical shock can result in death or serious injury:
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. iii Reference Manual 00809-0100-4075, Rev CA NOTICE The THUM and all other wireless devices should be installed only after the Smart Wireless Gateway has been installed and is functioning properly. Wireless devices should also be powered up in order of proximity from the Smart Wireless Gateway, beginning with the closest. This will result in a simpler and faster network installation. NOTICE During normal operation, or in fault condition, the THUM will cause a 2.5 V drop in the connected loop. It is important to ensure that the power supply can provide at least 2.5 V more than the lift off voltage of the wired device to make sure it works properly with the THUM installed. To determine the lift off voltage for the wired device, review the wired device operation and installation manual. iv Reference Manual 00809-0100-4075, Rev CA Content Table of Contents March 2014 1Section 1: Introduction 1.1 Safety messages. 1 1.1.1 Warnings . 1 1.2 Overview . 2 1.2.1 Manual . 2 1.2.2 Features . 3 1.3 Considerations . 3 1.3.1 General . 3 1.3.2 Commissioning . 3 1.3.3 Mechanical. 3 1.3.4 Electrical . 3 1.3.5 Environmental . 3 1.3.6 Wireless considerations. 4 1.4 Service support. 6 1.5 Product recycling/disposal . 6 2Section 2: Configuration 2.1 Safety messages. 7 2.1.1 Warnings . 7 2.2 Connections . 7 2.3 Device sensor configuration. 8 2.4 Connection diagrams . 8 2.5 Device network configuration . 9 2.5.1 Join device to network . 9 2.5.2 Configure update rate . 9 2.5.3 Configure THUM long tag . 10 2.5.4 Wired device tag . 10 2.6 HART tree . 11 Table of Contents v Table of Contents March 2014 Reference Manual 00809-0100-4075, Rev CA 3Section 3: Mounting 3.1 Safety messages. 13 3.1.1 Warnings . 13 3.2 Mounting . 14 3.2.1 Direct mount . 14 3.2.2 Remote mount . 15 3.2.3 Power supply . 15 3.2.4 Load resistor . 15 3.2.5 Wiring . 16 3.3 Loop current test . 26 4Section 4: Commissioning 4.1 Safety messages. 29 4.1.1 Warnings . 29 4.2 Device network configuration . 30 4.2.1 Network status . 31 4.2.2 Verify operation . 31 5Section 5: Operation and Maintenance 5.1 Safety messages. 33 5.1.1 Warnings . 33 5.2 Startup sequence . 33 5.3 Advanced setup . 34 5.3.1 Configure advanced update rate . 34 5.3.2 4-20 mA current . 34 5.3.3 Voltage drop . 34 5.3.4 Discovery mode . 34 5.3.5 Configure HART polling . 35 5.3.6 Configure router only mode . 35 5.3.7 HART address . 35 5.3.8 HART master . 35 6Section 6: Troubleshooting 6.1 Overview . 37 6.1.1 Warnings . 37 vi Table of Contents Reference Manual 00809-0100-4075, Rev CA Table of Contents March 2014 AAppendix A: Reference Data A.1 Functional specifications . 39 A.2 Physical specifications. 39 A.3 Performance specifications . 40 A.4 Dimensional drawings. 41 A.5 Ordering information . 43 A.6 Accessories and spare parts . 44 BAppendix B: Product Certifications B.1 Approved Manufacturing Locations . 45 B.2 European Directive Information . 45 B.3 Telecommunication Compliance . 45 B.4 FCC and IC . 46 B.5 Ordinary Location Certification for FM . 46 B.6 Hazardous Locations Certificates . 46 Table of Contents vii Reference Manual 00809-0100-4075, Rev CA Section 1: Introduction March 2014 Section 1 Introduction Safety messages . page 1 Overview . page 2 Considerations . page 3 Service support . page 6 Product recycling/disposal . page 6 1.1 Safety messages Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (
performing an operation preceded by this symbol.
). Please refer to the following safety messages before 1.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury. Make sure only qualified personnel perform the installation.
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices. Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications. Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals. Introduction 1 Section 1: Introduction March 2014 1.2 1.2.1 Overview Manual Reference Manual 00809-0100-4075, Rev CA This manual is designed to assist in the installation, operation, and maintenance of the Smart Wireless THUM Adapter. Section 1: Introduction
Manual and Transmitter Overview Considerations Return of Materials Section 2: Configuration
Device Sensor Configuration Device Network Configuration Section 3: Mounting
Mount the Sensor Sensor Assembly/Leads Grounding Section 4: Commissioning
Network Status Verify Operation Section 5: Operation and Maintenance
Startup Sequence Advanced Setup Appendix A: Reference Data
Specifications Dimensional Drawings Ordering Information Appendix B: Product Certifications
Product Certifications Installation Drawings 2 Introduction Reference Manual 00809-0100-4075, Rev CA 1.2.2 Features Section 1: Introduction March 2014
An installation-ready solution that provides rich wireless HART data Works with any 2- or 4-wire HART devices Flexibility to meet your most demanding applications Wireless output with >99% data reliability delivers rich HART data, protected by industry leading security Gain access to additional HART information, such as diagnostics or multi-variable data Add wireless to almost any measurement point without affecting the approval of the sub-device IEC 62591 (WirelessHART) capabilities extend the full benefits of PlantWeb to previously inaccessible locations 1.3 1.3.1 Considerations General The Smart Wireless THUM Adapter is connected to a HART sub-device. With simple HART configuration, the THUM transmits the HART information from the sub-device into the Wireless network. 1.3.2 Commissioning The THUM can be commissioned before or after installation. It may be useful to bench commission the THUM before installation to ensure proper operation and to become familiar with the functionality. The instruments should be installed in accordance with intrinsically safe or non-incendive field wiring practices, when required. The THUM Adapter is powered when connected to a powered loop. 1.3.3 Mechanical When choosing an installation location and position for the transmitter, take into account access to the device. For best performance, the antenna should be vertical and have some space between objects in a parallel metal plane such as a pipe or metal framework, as the pipes or framework may adversely affect the performance of the antenna. 1.3.4 Electrical The THUM Adapter is connected into a powered 420 mA loop, powering itself by scavenging power. The THUM Adapter causes a voltage drop across the loop. The drop is linear from 2.25 volts at 3.5 mA to 1.2 volts at 25 mA, but does not effect the 420 mA signal on the loop. Under fault conditions, the maximum voltage drop is 2.5 volts. 1.3.5 Environmental Verify that the operating environment of the transmitter is consistent with the appropriate hazardous locations certifications. Introduction 3 Section 1: Introduction March 2014 Reference Manual 00809-0100-4075, Rev CA Temperature limits Operating Limit Storage Limit 40 to 185 F 40 to 85 C 40 to 185 F 40 to 85 C 1.3.6 Wireless considerations Power up sequence Power should not be applied to any wireless device until the Smart Wireless Gateway
(Gateway) is installed and functioning properly. Wireless devices should also be powered up in order of proximity from the Gateway, beginning with the closest. This will result in a simpler and faster network installation. Enable Active Advertising on the Gateway to ensure that new devices join the network faster. For more information see the Smart Wireless Gateway Manual
(Doc. No. 00809-0200-4420). THUM adapter position If possible, the THUM Adapter should be positioned vertically, either straight up or straight down, and it should be approximately 3 ft. (1 m) from any large structure, building, or conductive surface to allow for clear communication to other devices. If the THUM Adapter is mounted horizontally, wireless communication range may be decreased. Figure 1-1. THUM adapter position Conduit entry When installing the THUM Adapter into the conduit entry of a wired device, use an approved thread sealant. Thread sealant provides a water tight seal. The thread sealant also provides a lubrication to ensure easy removal of the THUM Adapter. M20 conduit adapter When using the M20 Conduit Adapter on the THUM Adapter, use an approved thread sealant and tighten wrench tight to the THUM Adapter. When installing the M20 conduit adapter into a conduit tighten to 32.5 Nm/25 ft-lb. to ensure water tight seal. 4 Introduction Reference Manual 00809-0100-4075, Rev CA Section 1: Introduction March 2014 Field communicator connections In order for the Field Communicator to interface with the THUM Adapter, the wired device must be powered. The Field Communicator must be put into poll mode and should use the THUM Adapter address of 63. Power supply Minimum loop load of 250 Ohms. The THUM Adapter communicates and derives power from a standard 4-20 mA/HART loop. The THUM Adapter causes a small voltage drop on the loop which is linear from 2.25 V at 3.5 mA to 1.2 V at 25 mA. Under fault conditions, the maximum voltage drop is 2.5 V. The THUM Adapter will not affect the 4-20 mA signal under normal or fault conditions as long as the loop has at least a 2.5 V margin at the maximum loop current (25 mA for a typical 4-20 mA/HART device). Limit the power supply to 0.5 Amps maximum, and voltage to 55 Vdc. Loop Current THUM Adapter voltage drop 3.5 mA 25 mA 2.25 V 1.2 V Load resistor If required, add a load resistor as shown in Figure 3-20, Figure 3-22, and Figure 3-24. The resistor should be adequately rated for the application (1W minimum) and be compatible with the supplied splice connector which accepts wire sizes from 14 to 22 AWG. When adding a load resistor, ensure that uninsulated conductors do not contact the enclosure and/or other exposed metal parts. Introduction 5 Section 1: Introduction March 2014 Reference Manual 00809-0100-4075, Rev CA 1.4 Service support To expedite the return process outside of North America, contact your Emerson Process Management representative. Within the United States, call the Emerson Process Management Response Center toll-free number 1 800 654 7768. The center, which is available 24 hours a day, will assist you with any needed information or materials. The center will ask for product model and serial numbers, and will provide a Return Material Authorization (RMA) number. The center will also ask for the process material to which the product was last exposed. Individuals who handle products exposed to a hazardous substance can avoid injury if they are informed of, and understand, the hazard. If the product being returned was exposed to a hazardous substance as defined by OSHA, a copy of the required Material Safety Data Sheet (MSDS) for each hazardous substance identified must be included with the returned goods. 1.5 Product recycling/disposal Recycling of equipment and packaging should be taken into consideration and disposed of in accordance with local and national legislation/regulations. 6 Introduction Reference Manual 00809-0100-4075, Rev CA Section 2: Configuration March 2014 Section 2 Configuration Safety messages . page 7 Connections . page 7 Device sensor configuration . page 8 Connection diagrams . page 8 Device network configuration . page 9 HART tree . page 11 2.1 Safety messages Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (
performing an operation preceded by this symbol.
). Please refer to the following safety messages before 2.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. 2.2 Connections Section 2 details wiring the THUM Adapter to the different types of compatible sub-devices. Configuration 7 Section 2: Configuration March 2014 Reference Manual 00809-0100-4075, Rev CA 2.3 Device sensor configuration The THUM Adapter, attached to a powered sub-device, receives HART communication from a handheld Field Communicator or AMS. Field communicator In order to communicate with the THUM Adapter, polling must be activated on the Field Communicator. The default address for the THUM Adapter is 63. Also, note that any configuration changes must be sent to the transmitter using the Send key (F2). AMS wireless configurator AMS is capable of connecting devices directly using a HART modem or the Gateway. For configuring through AMS Wireless Configurator, double click the device icon and choose the Configure/Setup tab. AMS configuration changes are implemented when the Apply button is selected. 2.4 Connection diagrams Bench hook-up Connect the bench equipment as shown in either Figure 2-1 or Figure 2-2, and turn on the Field Communicator by pressing the ON/OFF key or log into AMS. The Field Communicator or AMS will search for a HART-compatible device and indicate when the connection is made. If the Field Communicator or AMS fail to connect, it indicates that no device was found. If this occurs, refer to Section 4: Commissioning. Field hook-up Section 2: Configuration details the field hook-up requirements in Figure 2-1 and Figure 2-2. Figure 2-1. THUM adapter only, powered by a current source THUM Adapter Green Red Black White Yellow Ground 250 Ohm Resistor not required, but may be used to verify current
+
-
20 mA Current Source HART Modem 8 Configuration Reference Manual 00809-0100-4075, Rev CA Section 2: Configuration March 2014 Figure 2-2. THUM adapter only, powered by a 24 V power supply with 1200 Ohm resistor to limit current to 20 mA THUM Adapter Green Red Black White Yellow
+
-
24V Power Supply Ground 1200 Ohm Resistor HART MODEM The 1200 Ohm resistor should be adequately rated for the application (3W minimum). 2.5 2.5.1 Device network configuration Join device to network Fast Keys 2, 1, 1 In order to communicate with the Smart Wireless Gateway, and ultimately the Host System, the THUM must be configured to communicate over the wireless network. This step is the wireless equivalent of connecting wires from a transmitter to the host system. 1. 2. 3. From the Home screen, select 2: Configure. Select 1: Guided Setup. Select 1: Join Device to Network. Using a Field Communicator or AMS, enter the Network ID and Join Key so that they match the Network ID and Join Key of the Smart Wireless Gateway and other devices in the network. If the Network ID and Join Key are not identical to those set in the Gateway, the THUM will not communicate with the network. The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup>Network>Settings page on the web server. 2.5.2 Configure update rate Fast Keys 2, 1, 2 The Update Rate is the frequency at which a new measurement is taken and transmitted over the wireless network. This by default is 1 minute. This may be changed at commissioning, or at any time via AMS Wireless Configurator. The Update Rate is user selectable from 8 seconds to 60 minutes. 1. 2. 3. From the Home screen, select 2: Configure. Select 1: Guided Setup. Select 2: Configure Update Rate. Configuration 9 Section 2: Configuration March 2014 Reference Manual 00809-0100-4075, Rev CA 2.5.3 Configure THUM long tag Fast Keys 2, 2, 4, 2 The Long Tag is how the THUM Adapter will show up in the Smart Wireless Gateway web interface. By setting this parameter to a unique value it will be easier to determine which THUM Adapter you are communicating with. One way to do this is to use the tag number of the wired device that the THUM adapter is connected to followed by THUM (HARTTAG-THUM). 1. 2. 3. 4. From the Home screen, select 2: Configure. Select 1: Manual Setup. Select 2: Device Information tab. Enter the Long Tag. 2.5.4 Wired device tag For HART 5 devices the THUM Adapter uses the message field when reporting the HART tag to the Smart Wireless Gateway. To ensure that you can identify the wired device in the Gateway make sure to write the tag information into the message field for all HART 5 devices. For HART 6 or newer devices the THUM reports the long tag as the HART tag to the Gateway. 10 Configuration Reference Manual 00809-0100-4075, Rev CA Section 2: Configuration March 2014 2.6 HART tree Configuration 11 Section 2: Configuration March 2014 Reference Manual 00809-0100-4075, Rev CA 12 Configuration Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Section 3 Mounting Safety messages . page 13 Mounting . page 14 Loop current test . page 26 3.1 Safety messages Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (
performing an operation preceded by this symbol.
). Please refer to the following safety messages before 3.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Mounting 13 Section 3: Mounting March 2014 3.2 Mounting Reference Manual 00809-0100-4075, Rev CA The THUM can be installed in one of two configurations:
Direct Mount: The THUM Adapter is connected directly to the conduit entry of the wired device. Figure 3-1. Direct Mount 3.2.1 Direct mount 1. 2. 3. 4. Install the HART device according to standard installation practices, being sure to use an approved thread sealant on all connections. Attach the THUM Adapter to the wired device as shown in Figure 3-1. When installing the THUM Adapter into the conduit entry of a wired device, use an approved thread sealant. Connect the THUM Adapter to the HART wired device using the wiring diagrams below. See Figure 3-19 through Figure 3-26 on the following pages. Close the housing cover on the HART wired device, so that metal touches metal, but do not over tighten to prevent damaging the unit. NOTE Two splice connectors are included with the THUM Adapter. The first is a two connection splice. The second is a three connection splice for use with a resistor, if there is not enough resistance in the loop. Both of these splice connectors can accept 14 to 22 gauge wire. See wired device reference manual for information on the required loop resistance. Remote Mount: The THUM Adapter is mounted separate from the wired device housing and then connected to the wired device using conduit. Figure 3-2. Remote mount 14 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 3.2.2 Remote mount 1. 2. 3. 4. 5. 6. Install the HART device according to standard installation practices, being sure to use an approved thread sealant on all connections. The THUM Adapter should be mounted as shown in Figure 3-2 on page 14. Connect the THUM Adapter to the wired device using standard practices. Wire running from the THUM Adapter to the wired device must be shielded or in conduit. Ground the Remote Mount Kit per local practices. Connect the THUM Adapter to the HART wired device using the wiring diagrams below. See Figure 3-19 through Figure 3-26 on the following pages. Close the housing cover on the HART wired device, so that metal touches metal, but do not over tighten to prevent damaging the unit. NOTE Two splice connectors are included with the THUM Adapter. The first is a two connection splice. The second is a three connection splice for use with a resistor, if there is not enough resistance in the loop. Both of these splice connectors can accept 14 to 22 gauge wire. See wired device reference manual for information on the required loop resistance. 3.2.3 Power supply Minimum loop load of 250 Ohms. The THUM Adapter communicates and derives power from a standard 4-20 mA/HART loop. The THUM Adapter causes a small voltage drop on the loop which is linear from 2.25 V at 3.5 mA to 1.2 V at 25 mA. Under fault conditions, the maximum voltage drop is 2.5 V. The THUM Adapter will not affect the 4-20 mA signal under normal or fault conditions as long as the loop has at least a 2.5 V margin at the maximum loop current (25 mA for a typical 4-20 mA/HART device). Limit the power supply to 0.5 Amps maximum, and voltage to 55 Vdc. Loop Current THUM Adapter voltage drop 3.5 mA 25 mA 2.25 V 1.2 V 3.2.4 Load resistor If required, add a load resistor as shown in Figure 3-20, Figure 3-22, and Figure 3-24. The resistor should be adequately rated for the application (1W minimum) and be compatible with the supplied splice connector which accepts wire sizes from 14 to 22 AWG. Mounting 15 Section 3: Mounting March 2014 3.2.5 Wiring Reference Manual 00809-0100-4075, Rev CA Note:
In order for the THUM Adapter to function properly there must be at least 250 Ohms resistance in the loop. If the 420 mA loop does not have the required resistance, wire a resistor as shown in Figure 3-20, Figure 3-22, or Figure 3-24 as applicable. When adding a load resistor ensure that uninsulated conductors do not contact the enclosure and/or other exposed metal parts. Figure 3-3. Direct mount wiring diagram for 2-wire device THUM Adapter Green Red Black White Yellow Wired Device Ground
- PWR / COMM
+ PWR / COMM 4-20 mA Loop +
4-20 mA Loop -
Power +
Supply-
Splice Connector Load Resistor 250 NOTE:
In order for the THUM Adapter to function properly there must be at least 250 Ohms resistance in the loop. If the 420 mA loop does not have the required resistance, wire a resistor as shown in Figure 3-6, Figure 3-10, or Figure 3-13 as applicable. Figure 3-4. Remote mount wiring diagram for 2-wire device THUM Adapter Remote Mount Housing Green Ground Red Black White Yellow 4-20 mA Loop +
4-20 mA Loop -
+ Power
- Supply Shield Wire Load Resistor 250
+ COMM
- COMM To Wired Device 16 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Figure 3-5. Direct mount wiring diagram for 2-wire device with resistor THUM Adapter Green Red Black White Yellow Wired Device Ground 4-20 mA Loop +
4-20 mA Loop -
Power +
Supply-
- PWR / COMM
+ PWR / COMM Load Resistor 250 Splice Connector Figure 3-6. Remote mount wiring diagram for 2-wire device with resistor THUM Adapter Green Ground Red Black White Yellow Remote Mount Housing Load Resistor 250 4-20 mA Loop +
4-20 mA Loop -
+ Power
- Supply Shield Wire
+ COMM
- COMM To Wired Device Figure 3-7. Direct mount wiring diagram for 4-wire passive device THUM Adapter Green Red Black White Yellow Wired Device Ground Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Power +
Supply-
Load Resistor 250
+
M M O C
-
M M O C
+
r e w o P
-
r e w o P Mounting 17 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA NOTE:
A passive loop exists when the wired device is not supplying power to the 420 mA loop. It is important to verify if the wired device is operating in active or passive mode. Figure 3-8. Remote mount wiring diagram for 4-wire passive device THUM Adapter Remote Mount Housing Green Ground Red Black White Yellow 4-20 mA Loop +
4-20 mA Loop -
+ Power
- Supply Shield Wire Load Resistor 250
+ COMM
- COMM To Wired Device Figure 3-9. Direct mount wiring diagram for 4-wire passive device with resistor THUM Adapter Green Red Black White Yellow Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Load Resistor 250 Power +
Supply-
Wired Device Ground
+
M M O C
-
M M O C
+
r e w o P
-
r e w o P 18 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Figure 3-10. Remote mount wiring diagram for 4-wire passive device with resistor THUM Adapter Remote Mount Housing Load Resistor 250 4-20 mA Loop +
4-20 mA Loop -
+ Power
- Supply Shield Wire
+ COMM
- COMM To Wired Device Green Ground Red Black White Yellow Figure 3-11. Direct mount wiring diagram for 4-wire active device THUM Adapter Green Yellow White Black Red Wired Device Ground Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Input Card Load Resistor 250
+
M M O C
-
M M O C
+
r e w o P
-
r e w o P NOTE:
An active loop exists when the wired device is supplying the power to the 4-20 mA loop. It is important to verify if the wired device is operating in active or passive mode. Mounting 19 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA Figure 3-12. Remote mount wiring diagram for 4-wire active device THUM Adapter Remote Mount Housing Green Ground Red Black White Yellow
+ COMM
- COMM To Wired Device 4-20 mA Loop +
4-20 mA Loop -
Shield Wire Input Card Load Resistor 250 Figure 3-13. Direct mount wiring diagram for 4-wire active device with resistor THUM Adapter Green Yellow White Black Red Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Load Resistor 250 Input Card Wired Device Ground
+
M M O C
-
M M O C
+
r e w o P
-
r e w o P 20 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Figure 3-14. Remote mount wiring diagram for 4-wire active device with resistor THUM Adapter Remote Mount Housing Load Resistor 250 Green Ground Red Black White Yellow
+ COMM
- COMM To Wired Device Shield Wire 4-20 mA Loop +
4-20 mA Loop -
Input Card Load Resistor 250 Figure 3-15. Direct mount wiring diagram for 4-wire active device with no 4-20 mA loop THUM Adapter Green Yellow White Black Red Wired Device Splice Connector Ground Load Resistor 250
+
M M O C
-
M M O C
+
r e w o P
-
r e w o P Mounting 21 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA Figure 3-16. Remote mount wiring diagram for 4-wire active device with no 4-20 mA loop THUM Adapter Remote Mount Housing Load Resistor 250 Green Ground Red Black White Yellow
+ COMM
- COMM To Wired Device Figure 3-17. THUM adapter only, powered by a 24 V power supply with 1200 Ohm resistor to limit current to 20 mA THUM Adapter Green Red Black White Yellow Ground 250 Ohm Resistor Junction Box
+
-
24 V Power Supply 1200 Ohm Resistor Required 22 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Figure 3-18. THUM adapter only, powered by a 24 V power supply with 1200 Ohm resistor to limit current to 20 mA THUM Adapter Remote Mount Housing 250 Ohm Resistor Green Ground Red Black White Yellow
+
-
24 V Power Supply 1200 Ohm Resistor Required Figure 3-19. Wiring diagram for 2-wire device THUM Adapter Green Red Black White Yellow Wired Device Ground 4-20 mA Loop +
4-20 mA Loop -
Splice Connector
- PWR / COMM
+ PWR / COMM Figure 3-20. Wiring diagram for 2-wire device with resistor THUM Adapter Wired Device Green Red Black White Yellow Ground 4-20 mA Loop +
4-20 mA Loop -
Resistor Splice Connector
- PWR / COMM
+ PWR / COMM NOTE A passive loop exists when the wired device is not supplying power to the 4-20 loop. It is important to verify if the wired device is operating in active or passive mode. Mounting 23 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA Figure 3-21. Wiring diagram for 4-wire passive device THUM Adapter Wired Device Ground Green Red Black White Yellow 4-20 mA/HART +
4-20 mA/HART -
+
r e w o P
-
r e w o P Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Power +
Power -
Figure 3-22. Wiring diagram for 4-wire passived device with resistor THUM Adapter Green Red Black White Yellow Wired Device Ground Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Resistor Power +
Power -
4-20 mA/HART +
4-20 mA/HART -
+
r e w o P
-
r e w o P NOTE An active loop exists when the wired device is supplying power to the 4-20 mA loop. It is important to verify if the wired device is operating in an active or passive mode. Figure 3-23. Wiring diagram for 4-wire active device THUM Adapter Green Yellow White Black Red Wired Device Ground Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Power +
Power -
4-20 mA/HART +
4-20 mA/HART -
+
r e w o P
-
r e w o P 24 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 Figure 3-24. Wiring diagram for 4-wire active device with resistor THUM Adapter Green Yellow White Black Red Wired Device Ground Splice Connector 4-20 mA Loop +
4-20 mA Loop -
Resistor Power +
Power -
4-20 mA/HART +
4-20 mA/HART -
+
r e w o P
-
r e w o P Figure 3-25. Wiring diagram for 4-wire active device with no 4-20 mA loop THUM Adapter Green Yellow White Black Red Wired Device Ground Splice Connector Resistor Power +
Power -
4-20 mA/HART +
4-20 mA/HART -
+
r e w o P
-
r e w o P Figure 3-26. Wiring diagram for THUM adapter as router, no wired device THUM Adapter Green Red Black White Yellow Ground 24V Power 250 Ohm 1200 Ohm Resistor Junction Box The 1200 Ohm resistor should be adequately rated for the application (3W minimum). Mounting 25 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA 3.3 Loop current test To verify that the THUM Adapter will work under all conditions, a loop current test should be performed. This test will exercise the loop under the highest possible voltage drop conditions. Place loop in manual control. Drive loop to high alarm level. For details see wired device instruction manual. When the THUM Adapter is connected to a valve, this will need to be done at the current source and not from the valve. When the THUM Adapter is connected to a transmitter, this will need to be performed at the transmitter. Place the THUM Adapter into fixed voltage drop mode. 1. 2.
3. AMS Right click on the THUM Adapter and select Configure. When the menu opens, select Manual Setup from the window on the left and select the Wired Device tab on the top. Make sure that the Time drop down menu at the bottom of the page has Current selected. Under the Voltage Drop drop down menu in the Smart Power Options box, select Fixed Voltage Drop. Hit the Apply button to make any changes. See Figure 3-27 on page 27. Field communicator When communicating to the THUM Adapter select: Configure - Manual setup - Wired Device
- Voltage Drop Mode. In the method choose Fixed Voltage Drop. Function Key Sequence Menu Items Voltage Drop 2,2,2,2 Voltage Drop Verify that the current on the loop reaches the high alarm levels. Place the THUM Adapter into variable voltage drop mode. 4. 5. AMS Right click on the THUM Adapter and select Configure. When the menu opens, select Manual Setup from the window on the left and select the Wired Device tab on the top. Make sure that the Time drop down menu at the bottom of the page has Current selected. Under the Voltage Drop drop down menu in the Smart Power Options box, select Variable Voltage Drop. Hit the Apply button to make any changes. See Figure 3-27. Field communicator When communicating to the THUM Adapter select: Configure - Manual setup - Wired Device
- Voltage Drop Mode. In the method choose Variable Voltage Drop. Function Key Sequence Menu Items Voltage Drop 2,2,2,2 Voltage Drop 26 Mounting Reference Manual 00809-0100-4075, Rev CA Section 3: Mounting March 2014 6. Remove loop from high alarm value. Figure 3-27. AMS configure screen Mounting 27 Section 3: Mounting March 2014 Reference Manual 00809-0100-4075, Rev CA 28 Mounting Reference Manual 00809-0100-4075, Rev CA Section 4: Commissioning March 2014 Section 4 Commissioning Safety messages . page 29 Device network configuration . page 30 4.1 Safety messages Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (
performing an operation preceded by this symbol.
). Please refer to the following safety messages before 4.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Commissioning 29 Section 4: Commissioning March 2014 Reference Manual 00809-0100-4075, Rev CA 4.2 Device network configuration In order to communicate with the Smart Wireless Gateway, and ultimately the Information System, the transmitter must be configured to communicate with the wireless network. This step is the wireless equivalent of connecting wires from a transmitter to the information system. Using a Field Communicator or AMS, enter the Network ID and Join Key so that they match the Network ID and Join Key of the gateway and other devices in the network. If the Network ID and Join Key are not identical, the THUM Adapter will not communicate with the network. The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup>Net-
work>Settings page on the web server, shown in Figure 4-1. Figure 4-1. Gateway network setting AMS Right click on the THUM Adapter and select Configure. When the menu opens, select Join Device to Network and follow the method to enter the Network ID and Join Key. Field communicator The Network ID and Join Key may be changed in the wireless device by using the following Fast Key sequence. Set both Network ID and Join Key. Operation can be verified in three locations: by using the Field Communicator, at the Gateway via the Smart Wireless Gateways integrated web server, or via AMS Wireless Configurator. Function Key Sequence Menu Items Wireless Setup 1,4 Smart Power, Network ID, Set Join Key, Radio State 30 Commissioning Reference Manual 00809-0100-4075, Rev CA Section 4: Commissioning March 2014 4.2.1 Network status If the THUM Adapter was configured with the Network ID and Join Key and sufficient time for network polling has passed, the transmitter should be connected to the network. To verify connectivity, open the Smart Wireless Gateways integral web interface and navigate to the Explorer page. This page will display the THUM Adapter's HART tag, PV, SV, TV, QV, and Update Rate. A green status indicator means that the device is working properly. A red indicator means that there is a problem with either the device or its communication path. For more detail on a specific device, click on the tag name. 4.2.2 Verify operation Operation can be verified in three locations: by using the 375 Field Communicator, at the Gateway via the Smart Wireless Gateways integrated web server, or via AMS Wireless Configurator. Field communicator In order for the THUM adapter to communicate with a Field Communicator, a THUM adapter DD is required. The Field Communicator must be put into a polling mode using the THUM adapter address of 63. Connect the Field Communicator to the wired device. The Field Communicator should find both the THUM adapter and the wired device. Table 4-1. Field Communicator connections Function Key Sequence Menu Items Communications 3, 3 Join Status, Wireless Mode, Join Mode, Number of Available Neighbors, Number of Advertisements Heard, Number of Join Attempts Smart Wireless Gateway If the THUM Adapter was configured with the Network ID and Join Key, and sufficient time has passed for network polling, the transmitter will be connected to the network. To verify device operation and connection to the network with the Smart Wireless Gateways integrated web server, open the Smart Wireless Gateways integral web interface and navigate to the Explorer page. NOTE:
It may take several minutes for the device to join the network. Commissioning 31 Section 4: Commissioning March 2014 Reference Manual 00809-0100-4075, Rev CA AMS Wireless Configurator When the device has joined the network, it will appear in the Wireless Configurator as illustrated below. Troubleshooting If the device is not operating properly, refer to the troubleshooting section of the manual. The most common cause of incorrect operation is the Network ID and Join Key. The Network ID and Join Key in the device must match that of the Smart Wireless Gateway. The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup>Network>Settings page on the web server. The Network ID and Join Key may be changed in the wireless device by using the following Fast Key sequence. Reference information Function Key Sequence Menu Items Wireless Setup 1, 4 Smart Power, Network ID, Set Join Key, Radio State NOTE In order to communicate with a Field Communicator, the wired device must be powered. Table 4-2. THUM adapter HART fast key sequence Function Key Sequence Menu Items Device Info 2, 2, 4, 3 Guided Setup Manual Setup 2, 1 2, 2 Wireless 2, 2, 1 Manufacturer, Model, Final Assembly Number, Universal, Field Device, Software, Hardware, Descriptor, Message, Date, Model Number I, II, III, SI Unit Restriction, Country Configure, Guided Setup, Join Device to Network, Configure Update Rate, Zero Trim, Configure Device Display, Configure Process Alarms Configure, Manual Setup, Wireless, Pressure, Device Temperatures, Device Information, Display, Other Network ID, Join Device to Network, Configure Update Rate, Configure Broadcast Power Level, Power Mode, Power Source 32 Commissioning Reference Manual 00809-0100-4075, Rev CA Section 5: Operation and Maintenance March 2014 Section 5 Operation and Maintenance Safety messages . page 33 Startup sequence . page 33 Advanced setup . page 34 5.1 Safety messages Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (
performing an operation preceded by this symbol.
). Please refer to the following safety messages before 5.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. 5.2 Startup sequence Because the THUM is a power scavenging device, different capabilities are available at different times after startup. Configuration is available immediately after startup and includes Update Rate and Discovery method. All network settings including Network ID, Join Key can not be set until the radio is completely initialized. This may take up to three (3) minutes after startup. After this amount of time has passed, the THUM adapter will start to join the network. Time to join the network depends on network size and number of devices and if active advertising is turned on in the Gateway. After sufficient time to join has passed go to the Explorer page on the Smart Wireless Gateway to see if the THUM has joined. Operation and Maintenance 33 Section 5: Operation and Maintenance March 2014 Reference Manual 00809-0100-4075, Rev CA 5.3 5.3.1 Advanced setup Configure advanced update rate Fast Keys 2, 2, 1,3 The Configure Update Rate method sets all three update rates based on one user input. The configure Advanced Update Rate method allows for each update rate to be set independently of the other two. Values for all update rates are between 8 seconds and 60 minutes. Only one update rate can be set to 8 seconds. In AMS Select Manual Setup and then the Wireless tab. 5.3.2 4-20 mA current Fast Keys 2, 2, 2,1 This optimizes the THUM Adapter to the available loop current. There are two options Variable Current Mode and Fixed Current Mode. Variable current mode is the default mode and is used when the current on the loop is changing between 3.5 mA to 25 mA. Fixed Current mode is user selectable. This mode is for when the current on the loop is fixed and will not drop below 15 mA. If the current drops below 15 mA when the THUM Adapter is in fixed current mode, there may be issues with network traffic, and the THUM Adapter may drop off of the wireless network. The HART loop will not be affected. In AMS Select Manual Setup and then the Wired Device tab. 5.3.3 Voltage drop Fast Keys 2, 2, 2,2 This optimizes the THUM Adapter to the available voltage on the loop. There are two options:
Variable and Fixed. Variable is the default mode. In Variable mode the THUM drops between 2.25 V at 3.5 mA and 1.2 V at 25 mA. In Fixed mode the THUM will always drop 2.25 volts. Fixed mode is used for verifying that there is enough voltage on the loop in the loop check procedure. In AMS Select Manual Setup and then the Wired Device tab. 5.3.4 Discovery mode Fast Keys 2, 2, 2,3 The discovery mode is how the THUM Adapter determines which wired device it will update for. There are 3 modes First Device Found, Fixed Polling Address, and Fixed Mapping. The default mode is First Device Found. In First Device Found Mode, the THUM Adapter will update for the first wired device that it finds on the wired bus. This mode is best used when there is only one device on the wired bus. If more than one wired device is found, the THUM Adapter will go into alert. 34 Operation and Maintenance Reference Manual 00809-0100-4075, Rev CA Section 5: Operation and Maintenance March 2014 In Fixed Polling Address mode, the THUM will only update for a wired device at specific HART polling address. Any address can be entered. If no device is found at this address, the THUM Adapter will go into an alarm state. In Fixed Mapping mode, the user selects the long tag from a list of devices that are currently on the wired bus. If the selected device goes off line, the THUM will not start updating new device, and will go into an alarm state. In AMS Select Manual Setup and then the Wired Device tab. 5.3.5 Configure HART polling Fast Keys 2, 2, 2,4 The Configure HART Polling method allows the user to select which commands the THUM Adapter will update for the wired device. The user can select from pre setup information or select custom and enter the HART command that they would like to have the THUM Adapter update for the wired device. In AMS Select Manual Setup and then the Wired Device. 5.3.6 Configure router only mode Fast Keys 2, 2, 5,2 This mode will set the THUM Adapter up as a router only device. The THUM Adapter will no longer look for wired devices or update for any wired device that is on the HART loop. The THUM Adapter will continue to send updates for itself and will also act as a wireless node in the wireless network. In AMS Select Manual Setup and then the Other tab. 5.3.7 HART address Fast Keys 2, 2, 5,3 This is the HART Polling address of the THUM adapter. This can be changed from 0 to 63. This is used when using wired HART communication to talk with the THUM. The THUM Adapter default HART polling address is 63. In AMS Select Manual Setup and then the Other tab. 5.3.8 HART master Fast Keys 2, 2, 5,4 Here is where the user can set the THUM Adapter to either a primary or secondary HART master. The THUM is set to primary as default, if another primary master is on the HART loop it may be necessary to change the THUM Adapter to a secondary master. This will not affect the functionality of the THUM Adapter. The number of retries can be set to between 2 and 5. In AMS Select Manual Setup and then the Other tab. Operation and Maintenance 35 Section 5: Operation and Maintenance March 2014 Reference Manual 00809-0100-4075, Rev CA 36 Operation and Maintenance Reference Manual 00809-0100-4075, Rev CA Section 6: Troubleshooting March 2014 Section 6 Troubleshooting Overview . page 37 Troubleshooting recommended actions . page 38 6.1 Overview Table 6-1 on page 38 provides summarized maintenance and troubleshooting suggestions for the most common operating problems. If you suspect malfunction despite the absence of any diagnostic messages on the Field Communicator display, follow the procedures described here to verify that transmitter hardware and process connections are in good working order. Always deal with the most likely checkpoints first. 6.1.1 Warnings Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe or non-incendive field wiring practices Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Troubleshooting 37 Section 6: Troubleshooting March 2014 Reference Manual 00809-0100-4075, Rev CA Table 6-1. Troubleshooting recommended actions Symptom Recommended Action Wired Troubleshooting Wired device does not turn on when THUM Adapter is added to loop Check the wiring and connections between THUM Adapter and wired device Verify that enough voltage is being supplied to power both the THUM Adapter and wired device Wired Device does not function properly through loop check Determine total voltage drop of system assume 2.5 volts for THUM Adapter Verify that enough voltage is on the loop Can not communicate with wired device or THUM Adapter Verify that wiring is correct Verify that enough voltage is being supplied to power both THUM Adapter and wired device Verify that between 250 and 1100 Ohms resistance is present Can not communicate with THUM Adapter Verify that wiring is correct Verify that enough voltage is being supplied to power both THUM Adapter and wired device Verify that between 250 and 1100 Ohms resistance is present Verify that Field communicator or AMS is set to poll for THUM Adapter address Power Cycle device to try again Configuration Troubleshooting Can not configure THUM Adapter with 375 or AMS THUM Adapter does not communicate with wired device Duplicate HART Master Detected Make sure that the correct DD is loaded into the 375 or AMS Run the Configure Discovery Mode method to connect the THUM Adapter to wired device Check the wiring and connections between THUM Adapter and wired device Verify that between 250 and 1100 Ohms resistance is present for HART communications Verify that the wired device is functioning properly Power Cycle device to try again Verify that two primary masters are on the loop Then set the THUM Adapter into secondary master mode Power Cycle device to try again If THUM Adapter is in secondary master mode and 375 or AMS is connected to loop this error will occur The error will disappear after the 375 or AMS is removed from the loop. Wireless Network Troubleshooting THUM Adapter not joining network Limited Bandwidth Error Verify network ID and join key Wait longer (30 min.) Verify THUM Adapter is within range of at least one other device Verify network is in active network advertise Power Cycle device to try again Verify device is configured to join. Send the Force Join command to the device See troubleshooting section of Smart Wireless Gateway for more information Reduce the Update Rate on THUM Adapter and wired device Increase communication paths by adding more wireless points Check that THUM Adapter has been online for at least an hour Check that THUM Adapter is not routing through a limited routing node Create a new network with an additional Smart Wireless Gateway 38 Troubleshooting Reference Manual 00809-0100-4075, Rev CA Appendix A: Reference Data March 2014 Appendix A Reference Data Functional specifications . page 39 Physical specifications . page 39 Performance specifications . page 40 Dimensional drawings . page 41 Ordering information . page 43 A.1 Functional specifications Input Any 2- or 4-wire HART powered device. Output IEC 62591 (WirelessHART) Humidity limits 0100% relative humidity Update rate User selectable, 8 sec. to 60 min. A.2 Physical specifications Electrical connections The THUM is connected into a powered 420 mA loop, powering itself by scavenging power. The THUM causes a voltage drop across the loop. The drop is linear from 2.25 volts at 3.5 mA to 1.2 volts at 25 mA, but does not effect the 420 mA signal on the loop. Under fault conditions, the maximum voltage drop is 2.5 volts. Power supply Minimum load on loop 250 Ohms. To maintain normal operating functions of the sub-device, the power in the loop must have at least a 2.5 V margin at a 250 Ohm load. Limit power supply to 0.5 Amps maximum. Limit power supply to 55 Vdc maximum. Field Communicator connections Utilize sub-device HART connections. Materials of construction Housing option D - Low-copper aluminum Housing option E - 316 SST Reference Data 39 Appendix A: Reference Data March 2014 Reference Manual 00809-0100-4075, Rev CA Paint - Polyurethane M20-Conduit Adapter - SST M20-Conduit Adapter O-ring - Buna-n Antenna Poly butadine terephthalate (PBT) / Polycarbonate (PC) integrated omnidirectional antenna Weight THUM Adapter only AL - 0.65 lbs. (0.29 kg) THUM Adapter only SST - 1.1 lbs. (0.5 kg) AL THUM Adapter with AL remote kit - 3.2 lbs. (1.45 kg) SST THUM Adapter with SST remote kit - 5.8 lbs. (2.65 kg) AL THUM Adapter with M20 conduit adapter - 0.85 lbs. (.038 kg) SST THUM Adapter with M20 conduit adapter - 1.3 lbs. (0.59 kg) Enclosure ratings Housing option code D is NEMA 4X, and IP66. Mounting The THUM Adapter may be attached directly to the conduit of any 2- or 4-wire HART device or mounted remotely by using the remote mount kit. A.3 Performance specifications ElectroMagnetic compatibility (EMC) All Models:
Meets all relevant requirements of EN 61326-1 (2006) when installed with shielded wiring. The sub-device must also use shielded wiring for installation. Vibration effect Output unaffected when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15 mm displacement peak amplitude / 60-500 Hz 2g). When the THUM Adapter is used on wired devices that are subject to vibration levels greater than 2g, it is recommended that the THUM Adapter be remotely mounted using the remote mount kit. Temperature limits Operating Limit Storage Limit 40 to 185 F 40 to 85 C 40 to 185 F 40 to 85 C Output specifications The THUM allows Wireless communication between the HART device it is connected to and the Smart Wireless Gateway. 40 Reference Data Reference Manual 00809-0100-4075, Rev CA Appendix A: Reference Data March 2014 A.4 Dimensional drawings THUM adapter 1/2 NPT 1.42
(36.1) 2.0
(50.8) 1.91
(48.5) 5.15
(130.8) Dimensions are in inches (millimeters) Reference Data 41 Appendix A: Reference Data March 2014 Reference Manual 00809-0100-4075, Rev CA THUM adapter with M20 conduit adapter 1.07
(27.17) Adapter for M20 Entry 2.0
(50.8) 1.91
(48.5) 4.85
(123.19) 6.48
(164.6) Dimensions are in inches (millimeters) THUM adapter with remote mount kit 4.20
(107) 3.45
(88) Conduit Entry 2.00
(50.8) Electronic Side 4.85
(123.19) Dimensions are in inches (millimeters) 42 Reference Data Reference Manual 00809-0100-4075, Rev CA Appendix A: Reference Data March 2014 SST Wireless Aluminum HART Data 1/2 - 14 NPT M20-Conduit Adapter Product Description Smart Wireless THUM Adapter Ordering information A.5 Table A-1. Smart Wireless THUM adapter ordering information The Standard offering represents the most common options. The starred options () should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Model 775 Output X Housing Standard D Expanded E Mounting Connection Standard 1 2 PlantWeb Functionality Standard 1 Certification Standard NA I5 I6 I1 N1 I7 N7 I2 N2 I3 IP IW IM Wireless Update Rate, Operating Frequency, and Protocol Standard WA3 Omnidirectional, Wireless Antenna, and SmartPower Options Standard WK9 Typical Model Number: 775XD11I5WA3WK9 No Approval FM Intrinsically Safe, Non-incendive CSA Intrinsically Safe ATEX Intrinsic Safety ATEX Type n IECEx Intrinsic Safety IECEx Type n INMETRO Intrinsic Safety INMETRO Type n China Intrinsic Safety Korea (KOSHA) Intrinsic Safety India (CCOE) Intrinsic Safety GOST (Russia) Intrinsically Safe User Configurable Update Rate, 2.4 GHz DSSS, WirelessHART Long range, Integral Antenna, Power Scavenging Reference Data Standard Standard Standard Standard Standard Standard 43 Appendix A: Reference Data March 2014 Reference Manual 00809-0100-4075, Rev CA A.6 Table A-2. Accessories Accessories and spare parts Item Description Remote Mount Kit - AI Remote Mount Kit - SST M20-Conduit Adapter Part Number 00775-9000-0001 00775-9000-0011 00775-9001-0001 44 Reference Data Reference Manual 00809-0100-4075, Rev CA Appendix B: Product Certifications March 2014 Appendix B Product Certifications Approved Manufacturing Locations . page 45 European Directive Information . page 45 Telecommunication Compliance . page 45 FCC and IC . page 46 Ordinary Location Certification for FM . page 46 Hazardous Locations Certificates . page 46 Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota, USA Emerson Process Management GmbH & Co. - Karlstein, Germany Emerson Process Management Asia Pacific Private Limited - Singapore European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. Electro Magnetic Compatibility (EMC) (2004/108/EC) Emerson Process Management complies with the EMC Directive. Radio and Telecommunications Terminal Equipment Directive (R&TTE) (1999/5/EC) Emerson Process Management complies with the R&TTE Directive. Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. B.1 B.2 B.3 Product Certifications 45 Appendix B: Product Certifications March 2014 Reference Manual 00809-0100-4075, Rev CA B.4 B.5 FCC and IC This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including any interference that may cause undesired operation of the device. Cet appareil est conforme la norme RSS Industrie Canada exempt de licence. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer dinterfrences et (2) cet appareil doit accepter toute interfrence, y compris les interferences pouvant causer un mauvais fonctionnement du dispositif. Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). B.6 Hazardous Locations Certificates North American Certifications Factory Mutual (FM) Approvals I5 FM Intrinsically Safe and Non-incendive Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G. Zone Marking: Class I, Zone 0, AEx ia llC Temperature Codes T4(-50 C Ta 70 C) Non-incendive for Class I, Division 2, Groups A, B, C, and D. Intrinsically safe and non-incendive when installed according to Rosemount Drawing 00775-0010. Enclosure Type 4X/IP66 CSA - Canadian Standards Association I6 CSA Intrinsically Safe Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. T3C(-50 C Ta 70 C) Intrinsically safe when installed according to Rosemount Drawing 00775-0012. Suitable for Class I, Division 2, Groups A, B, C, and D. Enclosure Type 4X/IP66 46 Product Certifications Reference Manual 00809-0100-4075, Rev CA Appendix B: Product Certifications March 2014 European Certifications I1 ATEX Intrinsic Safety Certificate: Baseefa09ATEX0125X Ex ia IIC T4(-50 C Ta 70 C) IP66 1180 Table B-1. Input Parameters II 1G Loop Power Ui = 30 V Ii = 200 mA Pi = 1.0 W Ci = 0 Li = 0 Special Conditions for Safe Use (X):
The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0. ATEX Type n Certificate: Baseefa09ATEX0131 Ex nA IIC T4 (-50 C Ta 70 C) Ui = 45 Vdc MAX IP66 II 3 G N1 1180 IECEx Certifications IECEx Intrinsic Safety I7 Certificate: IECEx BAS 09.0050X Ex ia IIC T4(-50 C Ta 70 C) IP66 Table B-2. Input Parameters Loop Power Ui = 30 V Ii = 200 mA Pi = 1.0 W Ci = 0 Li = 0 Special Conditions for Safe Use (X):
The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0. Product Certifications 47 Appendix B: Product Certifications March 2014 Reference Manual 00809-0100-4075, Rev CA N7 IECEx Type n Certificate: IECEx BAS 09.0058 Ex nA IIC T4 (-50 C Ta 70 C) Ui = 45 Vdc MAX IP66 INMETRO Certifications I2 Intrinsic Safety BR-Ex ia IIC T4 (-50 C Ta 70 C) Ga INMETRO Type n BR-Ex nA IIC T4 Gc (-50 C Ta 70 C) N2 China (NEPSI) Certifications I3 China (NEPSI) Intrinsic Safety Ex ia IIC T4 CCoE Certifications IW Intrinsic Safety Ex ia IIC T4 KOSHA Certifications IP Intrinsic Safety Ex ia IIC T4 GOST Certifications IM Intrinsically Safe Ex ia IIC T4 (-50 C Ta 70 C) Ex nA IIC T4 (-50 C Ta 70 C) IP66 48 Product Certifications Reference Manual 00809-0100-4075, Rev CA Appendix B: Product Certifications March 2014 Figure B-1. 775 THUM FM I.S. & Class 1, Div. 2 Installation Drawing (1 of 2) Product Certifications 49 Appendix B: Product Certifications March 2014 Reference Manual 00809-0100-4075, Rev CA Figure B-2. 775 THUM FM I.S. & Class 1, Div. 2 Installation Drawing (2 of 2) D E L L O R T N O C N U E R A S E I P O C D E T N I R P 50 Product Certifications Reference Manual 00809-0100-4075, Rev CA Appendix B: Product Certifications March 2014 Figure B-3. 775 THUM CSA I.S. Installation drawing Product Certifications 51 Appendix B: Product Certifications March 2014 Reference Manual 00809-0100-4075, Rev CA Figure B-4. 775 THUM CSA Installation Drawing 52 Product Certifications Reference Manual 00809-0100-4075, Rev CA March 2014 Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount. the Rosemount logotype, and SMART FAMILY are registered trademarks of Rosemount Inc. Coplanar is a trademark of Rosemount Inc. Halocarbon is a trademark of the Halocarbon Products Corporation.o. Fluorinert is a registered trademark of Minnesota Mining and Manufacturing Company Corporation Syltherm 800 and D.C. 200 are registered trademarks of Dow Corning Corporation. Neobee M-20 is a registered trademark of PVO International, Inc. HART is a registered trademark of the HART Communication Foundation. Foundation fieldbus is a registered trademark of the Fieldbus Foundation. All other marks are the property of their respective owners. March 2014 Rosemount, Inc. All rights reserved. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 906 8889 Emerson Process Management GmbH & Co. Argelsrieder Feld 3 82234 Wessling Germany Tel 49 (8153) 9390 Fax 49 (8153) 939172 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586 Emerson Process Management Latin America 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 USA Tel + 1 954 846 5030
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-04-07 | 2400 ~ 2483.5 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-04-07
|
||||
1 | Applicant's complete, legal business name |
Rosemount Inc
|
||||
1 | FCC Registration Number (FRN) |
0017340878
|
||||
1 | Physical Address |
Measurement Division
|
||||
1 |
Eden Prairie, Minnesota 55344-3695
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@intertek.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
LW2
|
||||
1 | Equipment Product Code |
775-WM
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M**** O**** P****
|
||||
1 | Title |
Project Test Engineer
|
||||
1 | Telephone Number |
612 8********
|
||||
1 | Fax Number |
612 8********
|
||||
1 |
M******@emerson.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Rosemount Inc.
|
||||
1 | Name |
M****** O******** P******
|
||||
1 | Physical Address |
8200 Market Blvd
|
||||
1 |
Chanhassen, Minnesota 55317
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
952-9********
|
||||
1 |
m******@emerson.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Rosemount Inc.
|
||||
1 | Name |
R****** J******** K******
|
||||
1 | Physical Address |
8200 Market Blvd
|
||||
1 |
Chanhassen, Minnesota 55317
|
|||||
1 |
United States
|
|||||
1 | Fax Number |
952-9********
|
||||
1 |
b******@emerson.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 05/22/2014 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Industial Control Field Adapter | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services NA, Inc.
|
||||
1 | Name |
J**** K********
|
||||
1 | Telephone Number |
651-7********
|
||||
1 | Fax Number |
651 7********
|
||||
1 |
j******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2400.00000000 | 2483.50000000 | 0.0063000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC