all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
USERS MANUAL | Users Manual | 575.61 KiB | ||||
1 | Block Diagram | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | Operational Description | |||||||
1 | Cover Letter(s) | |||||||
1 | Schematics | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | USERS MANUAL | Users Manual | 575.61 KiB |
Table of Contents 2. 3. 1. General Information...........................................................4 1.1 Introduction.......................................................................................... 4 1.2 Reader/Controller Types...................................................................... 4 1.3 Box Content ......................................................................................... 5 1.4 Ancillary Equipment............................................................................ 5 Technical Specifications ...................................................7 2.1 Key Features ........................................................................................ 8 Reader..................................................................................................................... 9 Controller................................................................................................................ 9 Installation.........................................................................10 3.1 Mounting the AYC- F/G/M60 ........................................................... 10 4. Wiring Instructions ............................................................11 5. Reader Functionality........................................................14 5.1 Transmit Mode................................................................................... 14 5.2 Programming the AYC-F/G/M60 Series ........................................... 14 Programming Menu.............................................................................................. 15 Entering Programming Mode............................................................................... 16 Exiting Programming Mode................................................................................. 16 Selecting Keypad Transmission Format............................................................... 16 Keypad Transmission Format Option Number .................................................... 17 Selecting Proximity Card Transmission Format .................................................. 22 Changing the Programming Code ........................................................................ 25 Changing the Facility Code.................................................................................. 25 Setting the Backlight and Format the Reader....................................................... 26 Return to Factory Default Settings....................................................................... 26 Replacing a Lost Programming Code .................................................................. 27 6. Controller Functionality....................................................28 6.1 Normal, Secure, and Master Users .................................................... 28 Normal User ......................................................................................................... 28 Secure User........................................................................................................... 29 Master User .......................................................................................................... 29 6.2 Modes of Operation ........................................................................... 29 Normal Mode ....................................................................................................... 29 Bypass Mode ........................................................................................................ 29 Secure Mode......................................................................................................... 30 Page ii AYC-Qx4 family manual Changing the Modes of Operation ....................................................................... 30 6.3 Auxiliary Input & Output .................................................................. 31 6.4 Door Alarms....................................................................................... 31 6.5 Internal Case and Back Tamper......................................................... 32 6.6 Lockout Feature (Keypad / Card Tamper)......................................... 32 6.7 Request to Exit (REX) Function........................................................ 32 6.8 Secure Application Appurtenances.................................................... 33 6.9 Programming the AYC- F/G/M60..................................................... 33 Programming Menu.............................................................................................. 34 Entering Programming Mode............................................................................... 34 Exiting Programming Mode................................................................................. 35 Changing Lock Strike Code ................................................................................. 35 Changing Auxiliary Code..................................................................................... 36 Changing the Programming Code ........................................................................ 37 Changing the Normal / Secure Code.................................................................... 37 Changing the Normal / Bypass Code and Door Chime Settings.......................... 38 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time39 Second Digit ................................................................................................. 39 Third and Fourth Digits ................................................................................ 39 Defining the Auxiliary Input and Output ............................................................. 40 Auxiliary Mode............................................................................................. 40 Auxiliary Settings ......................................................................................... 40 Quick Reference Guide for Auxiliary Mode Setting............................................ 41 Detailed Reference Guide .................................................................................... 42 Setting the Lockout Feature ................................................................................. 46 Setting the backlight behavior and format the reader........................................... 47 Enrolling Primary and Secondary Codes ............................................................. 47 Deleting Primary and Secondary Codes............................................................... 51 Relay Codes Assignment...................................................................................... 53 Relay Code Assignment using Search Method .................................................... 54 Pin Code Length / Factory Default Settings......................................................... 55 Replacing a Lost Programming Code .................................................................. 56 Replacing a Lost Normal / Secure Code .............................................................. 56 Limited Warranty............................................57 Technical Support .........................................60 Appendix A. Appendix B. Page iii AYC-Qx4 family manual Introduction 1. General Information 1.1 The AYC-F/G/M60 series is a vandal-resistant, waterproof, standalone, convertible integrated reader and controller. The AYC-F/G/M60 series automatically determines whether to function as a reader or as a controller. If the unit is connected to a standard access control unit, then it functions as a reader. If the unit is connected to Rosslare's secure application appurtenances such as the PS-A25T, PS-C25T or PS-C25TU, it functions as a secured controller. For information on how the unit functions as a reader, see Reader Functionality on page 14. For information on how the unit functions as a controller, see Controller Functionality on page 28. All of the units are water resistant and suitable for indoor or outdoor mounting. As a controller, the units accept up to 500 users, and allow entry via a personal identification number (PIN) and/or by presenting a proximity card. The pin code length for the controller has several options. The pin code length can be a set number of 4, 5 or 6 digits or it can be a 4-8 digits option. This manual contains the following information: Installation, Wiring instructions, and Operation Instructions. 1.2 Reader/Controller Types The different types of units of this series are:
Type 54 has PIN only Type 60 has PIN and Proximity card AYC-F/G/M54 AYC-F/G/M60
Standard
Standard Keypad Type Proximity
Backlight AYC-Qx4 family manual Page 4 Upon power-on reset, the AYC-F/G/M60 searches for the presence of Rosslare's secure application appurtenances. If a secure application appurtenance is detected, then the AYC-
F/G/M60 is automatically configured as a secure access control unit. This is indicated by two short beeps. If the secured controller is not detected, it is automatically configured as a reader, indicated by one short beep. 1.3 Box Content Before beginning verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest Rosslare office. One AYC- F/G/M60 unit Installation kit Installation and operating instructions secure application appurtenance (optional for controller) 1.4 Ancillary Equipment The following equipment is required to complete your installation:
Reader Compatible host controller (not supplied) - UL listed access control unit, i.e., model AC-215U Controller Secure Application Appurtenances such as the PS-A25T, PS-C25T or PS-C25TU secure controllers This unit connects to the following:
o Electric lock strike mechanism or a magnetic lock device, which implements fail safe (power to lock) or fail secure (power to open) functions. o Request to Exit (REX) buttonnormally open type. o Door monitor switch. Switch is closed when pressed. Page 5 AYC-Qx4 family manual Rosslare accessories can be found on www.rosslaresecurity.com. AYC-Qx4 family manual Page 6 2. Technical Specifications Specifications Electrical Characteristics Power supply type Operating voltage range AYC- F/G/M60 Linear type recommended 5 - 16VDC (when used as a controller, provided by the secure application appurtenance) Input current standby (12VDC) 105mA Input current max (16VDC) 140mA LED control input Dry contact N.O. Tamper output Open collector, active low, 32mA max sink current Up to 500ft (150 meters) using an 18AWG cable 1.77 inches (45mm) Cable distance to host controller Max proximity card read range*
Proximity card modulation Proximity card compatibility Card Transmit format (Reader) Keypad Transmit Format
(Reader) LED indicators Communication ASK/FSK at 125 KHz EM/HID cards 26-bit Wiegand, or Clock & Data Programmable PIN code formats Two tri-colored LEDs Data1/C1, Data0/C2open collector, 5V termination Page 7 AYC-Qx4 family manual Specifications Environmental Characteristics Operating temp. range Operating humidity Outdoor usage AYC- F/G/M60
-22 to 150 F (-30 to 65 C) 0 95% (non-condensing) Weather-resistant, meets IP-65, epoxy potted, suitable for outdoor use Mechanical Size
(Height x Width x Depth) Weight F: 4.72 x 3 x 0.827 inches (120 x 76 x 21 mm) G: 5.39 x 1.73 x 0.83 inches (137 x 44 x21 mm) M: XXXXXXXXX (XXXXXX) F: 1.05 lb (480g) G: 0.35 lb (160g) M: XXXXXX
*Measured using Rosslare proximity card (AT-14) or equivalent. Range also depends on electrical environment and proximity to metal. 2.1 Key Features The key features for the AYC- F/G/M60 series are:
Built-In Proximity Card Reader (125 KHz ASK/FSK Modulation) (for 60 series only) Patented, programmable Blue backlit keypad Optical back tamper sensor and open controller tamper output. Internal buzzer provides audible interface feedback Two status / programming Interface LEDs (tri-colored) Lockout feature on wrong entry (Keypad / Card Tamper) Fully potted construction for outdoor use Comes with mounting template for easier installation Comes with an installation kit that includes a security screw and a security screw tool AYC-Qx4 family manual Page 8 Reader Programmable keypad transmission format LED control input Programmable facility code Programmable Proximity Card Transmission Format o Clock & Data o 26-Bit Wiegand o Card + PIN Controller Bi-directional secure communication with Rosslares secure application appurtenance Three User Levels o Normal User o Secure User o Master User
"Code Search" feature that helps make maintaining user codes easier Three Modes of Operation o Normal Mode o Bypass Mode o Secure Mode Request-to-Exit (REX) signal from Rosslares secure application appurtenance Chime Bell and Siren features are available with secure application appurtenance Programmable Lock Strike Release, Siren, and Alarm Delay timers Programmable Auxiliary input with versatile functions. Programmable Auxiliary output functions Programmable PIN code length. Page 9 AYC-Qx4 family manual 3. Installation 3.1 Mounting the AYC- F/G/M60 Before starting, select the location to mount the AYC- F/G/M60. This location should be at shoulder height. Drill holes into the back of the unit according to how you want to mount the AYC-
F/G/M60. For US Gang Box installation, there are two-hole indicators on the back of the metal cover specifically aligned for the US Gang Box (A, in diagram below). For a four screw custom installation, there are four indicators on the back (B in diagram below). [This is Q-box need F/G/M boxes drawings]
Figure 1 Drilling mounting holes When the unit is used a reader, route the interface cable from the AYC- F/G/M60 to the Controller. When the unit is used as a secured controller, route the interface cable from the AYC-
F/G/M60 to Rosslares secure application appurtenance. A linear type power supply is recommended, when using the unit as a controller. Screw the AYC- F/G/M60 back cover to its mounting location. Return the AYC- F/G/M60 front cover to the mounted back plate. Secure the front cover by using the supplied security screw in the controllers Installation Kit. An L-Shaped tool is provided for use when tightening the security screw. AYC-Qx4 family manual Page 10 4. Wiring Instructions The unit is supplied with a 22-inch pigtail, having a 6-conductor cable. To connect the unit to the controller, perform the following:
Prepare the unit's cable by cutting the cable jacket back 1 inches and strip the wire inch. Prepare the controller cable by cutting the cable jacket back 1 inches and strip the wire inch. Splice the units pigtail wires to the corresponding controller wires and cover each connection. Refer to the wire color table below, and to the wiring diagrams provided on the following pages. Reader 5~16 VDC Shield / Ground Shield / Ground Black Ground Data 1 / Clock C 1 Data 0 / Data C 2 LEDCTL Tamper If the tamper output is used, connect the purple wire to the correct input on the controller when used as a reader, or to a zone input of an intruder alarm system when used as a controller. Trim and cover all unused conductors. White Communication Green Communication Brown LED Control / Auxiliary Input Purple Tamper Color Functionality Red Controller 5~16 VDC AUX. IN Tamper
+DC Input Note:
The individual wires from the unit are color-coded according the Wiegand standard. When using a separate Power Supply for the Reader, this Power Supply and that of the Controller must have a common ground. The Readers cable shield wire should preferably be attached to an earth ground, or a signal ground connection at the panel, or power supply end of the cable. This configuration is best for shielding the Reader cable from external interference Page 11 AYC-Qx4 family manual Wiring diagram #1 (below) shows the wiring for the Controller Application using a Dual Relay Secure Application Appurtenance. Rosslare PS-X25 AYC- F/G/M60 Figure 2 Controller Application Wiring Diagram #1 Wiring diagram #2 (below) shows the auxiliary output connection using internal power. Rosslare PS-X25 Figure 3 Controller Application Wiring Diagram #2 AYC-Qx4 family manual Page 12 Wiring diagram #3 (below) shows the auxiliary output connection using the external power. Rosslare PS-X25 Figure 4 Controller Application Wiring Diagram #3 AYC-
F/G/M60 Figure 5: Reader Application Wiring Diagram #4 Page 13 AYC-Qx4 family manual Red Mode/Transmit 5. Reader Functionality The AYC- F/G/M60 series can function both as a reader and as a controller. If the unit is connected to standard access controller, it functions as a reader, indicated by one beep immediately after power-on reset. The following explains how the AYC- F/G/M60 series functions as a reader. 5.1 Transmit Mode When the AYC- F/G/M60 is in Transmit Mode, it is ready to receive data from a presented Proximity Card or an entered PIN code. When the reader is in Transmit Door/Program Mode, the Transmit LED is red and the Program LED is off. When a Proximity Card or Keyboard entry is being transmitted, the Transmit LED will flash green. Keyboard data can be sent via one of eight different Keypad Transmission Formats. For more information, see Selecting Keypad Transmission Format on page 16. Proximity Cards presented to the reader are always sent in either 26-Bit Wiegand, Clock & Data or, Wiegand Card + PIN format. See Selecting Proximity Card Transmission Format on page 22 for more information. 5.2 Programming the AYC- F/G/M60 series is done solely via the unit's keypad driven Programming Menu System. To reach the Programming Menu System the AYC- F/G/M60 must first be placed into Programming Mode. During the F/G/M60 's manufacturing process certain codes and settings are pre-
programmed. These settings are the called the "Default Factory Settings". The table below shows the names of all the AYC- F/G/M60 Menus. Page 14 Programming the AYC- F/G/M60 Series AYC-Qx4 family manual Programming Menu Default Factory Settings are marked by a "*" sign. Menu Description 1 Selecting Keypad Transmission Format Single Key, 6-Bit Wiegand (Rosslare Format) Single Key, 6-Bit Wiegand with Nibble + Parity Bits Single Key, 8-Bit Wiegand, Nibbles Complemented 4 Keys Binary + Facility Code, 26-Bit Wiegand 1 to 5 Keys + Facility Code, 26-Bit Wiegand 6 Keys BCD and Parity Bits, 26-Bit Wiegand Single Key, 3x4 Matrix Keypad 1 to 8 Keys BCD, Clock & Data Single key, 4-bit Wiegand Selecting Card Transmission Format 26-Bit Wiegand Clock & Data Wiegand Card + PIN 2 3 Changing the Programming Code 4 Changing the Facility Code 6 Setting the Backlight always off always on 10 sec. backlight after key press otherwise off 10 sec. backlight after key press otherwise dimmed Setting Reader Format ASK FSK ASK + FSK Return to Factory Default Settings 0 Default
1234 0
Page 15 AYC-Qx4 family manual 2) Entering Programming Mode 1) Transmit LED will turn off. Mode/Transmit Press the # key 4 times. Program LED will turn red. Enter your 4 digit Programming Code. If the Programming Code is valid, the door LED will turn Mode/Transmit green and the AYC-
F/G/M60 will be in Programming Mode. Door/Program Red
Door/Program Green Note:
The factory 4-digit Programming Code is 1234. If a Programming Code is not entered within 30 seconds, the AYC- F/G/M60 will return to Transmit Mode. Exiting Programming Mode 1) Door/Program To exit the Programming Mode at any time press #:
You will hear a beep Mode/Transmit Red The Program LED will be off The Transmit LED will turn red 2) This indicates that the AYC- F/G/M60 has returned to Transmit Mode. 3) Wrong entries may reset the reader back to Transmit Mode. While in Programming Mode if no key is pressed for 30 seconds the AYC- F/G/M60 will exit Programming Mode and return to Transmit Mode. Selecting Keypad Transmission Format The AYC- F/G/M60 has eight different keypad transmission formats to select from. Follow the steps below to select the appropriate keypad transmission format that you wish to use. 1) Door/Program Enter Programming Mode. Mode/Transmit Green Page 16 AYC-Qx4 family manual 1 Mode/Transmit Door/Program Press 1 to enter. The Transmit LED will turn Red. Red Green
Enter the appropriate option no. for the keypad transmission format that you wish to select (see table below). If an incorrect option no. is entered the reader will return to Transmit Mode and the keypad transmission format will remain unchanged Look on the next page for more information on keypad transmission formats. System returns to Transmit Mode. You will hear three beeps. The Program LED will turn off The Transmit LED will turn red Mode/Transmit Door/Program Red Note:
Only one keypad transmission format can be active at any one time. When using the keypad transmission format "1 to 8 keys BCD, Clock & Data" (Option 8) an additional input is required to specify the number of keys in the PIN code. 2) 3) 4) 5) mber for the Ke ypad Transmission Format Option Number See the table below to determine the Option Nu Keypad Transmission Format you wish to select Option Number Keypad Transmission Format 1*
Single Key, 6-Bit Wiegand (Rosslare Format) Single Key, 6-Bit Wiegand with Nibble + Parity Bits 2 Single Key, 8-Bit Wiegand, Nibbles Complemented 3 4 4 Keys Binary + Facility Code, 26-Bit Wiegand 1 to 5 Keys + Facility Code, 26-Bit Wiegand 5 6 6 Keys BCD and Parity Bits, 26-Bit Wiegand Page 17 AYC-Qx4 family manual 7 8 9 Single Key, 3x4 Matrix Keypad 1 to 8 Keys BCD, Clock & Data Single Key Single key, 4-bit Weigand
* Option 1 is the default factory setting. More information on each of the different keypad transmission formats is available below and on the following pages. Option 1: Single Key, 6-Bit Wiegand (Rosslare Format) Each key press immediately sends 4 bits with 2 parity bits added. Even parity for the first 3 bits and odd parity for the last 3 bits. 0= 1 1010 0 ="A" in Hexadecimal 1= 0 0001 0 2= 0 0010 0 3= 0 0011 1 4= 1 0100 1 5= 1 0101 0 Option 2: Single Key, 6-Bit Wiegand Nibble and Parities Each key press immediately sends 4 bits with 2 parity bits added. Even parity for the first 3 bits and odd parity for the last 3 bits. 0 = 0 0000 1 1 = 0 0001 0 2 = 0 0010 0 3 = 0 0011 1 4 = 1 0100 1 5 = 1 0101 0 6 = 1 0110 0 7 = 1 0111 1 8 = 1 1000 1 9 = 1 1001 0
* = 1 1010 0 = "A" in Hexadecimal
# = 1 1011 1 = "B" in Hexadecimal 6= 1 0110 0 7= 1 0111 1 8= 1 1000 1 9= 1 1001 0
*= 1 1011 1 ="B" in Hexadecimal
#= 0 1100 1 ="C" in Hexadecimal AYC-Qx4 family manual Page 18 6 = 10010110 7 = 10000111 8 = 01111000 9 = 01101001
* = 01011010 = "A" in Hexadecimal
# = 01001011 = "B" in Hexadecimal Option 3: Single Key, 8-Bit Wiegand Nibbles Complemented Inverts the most significant bits in the message leaving the least 4 significant bits as Binary-Coded Decimal (BCD) representation of the key. The host system receives an 8-bit message. 0 = 11110000 1 = 11100001 2 = 11010010 3 = 11000011 4 = 10110100 5 = 10100101 Option 4: 4 Keys Binary + Facility Code, 26-Bit Wiegand Buffers 4 keys and outputs keypad data with a three digit facility code like a standard 26-Bit card output. The facility code is set in Programming Menu number four and can be in the range 000 to 255. The factory default setting for the facility code is 000. (See Changing the Facility Code on page 25 for more information). The keypad PIN code is 4-digit long and can range between 0000 and 9999. On the fourth key press of the 4 digit PIN code, the data is sent across the Wiegand Data lines as binary data in the same format as a 26-Bit Card. If the "*" key or the "#" key are pressed during PIN code entry, the keypad will clear the PIN code entry buffer, generate a beep and is ready to receive a new 4 digit keypad PIN code. If the entry of the 4 digits keypad PIN code is disrupted and no number key is pressed within 5 seconds, the keypad will clear the PIN code entry buffer, generate a beep and is ready to receive a new 4 digits keypad PIN code.
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP) Where:
EP = Even parity for first 12 bits. OP = Odd parity for last 12 bits. F = 8-Bit Facility Code. A = 16-Bit code generated from keyboard. Page 19 AYC-Qx4 family manual Option 5: 1 to 5 Keys + Facility Code, 26-Bit Wiegand Buffers up to 5 keys and outputs keypad data with a facility code like a 26-Bit card output. The facility code is set in Programming Menu number four and can be in the range 000 to 255. The factory default setting for the facility code is 000. (See Changing the Facility Code on page 25 for more information.) The keypad PIN code can be one to five digits long and can range between 1 and 65,535. When entering a keypad PIN code that is less than 5 digits long, the "#" key must be pressed to signify the end of PIN code entry. For keypad PIN codes that are 5 digits long, on the fifth key press of the 5 digit PIN code, the data is sent across the Wiegand Data lines as binary data in the same format as a 26-Bit Card. If the "*" key is pressed during PIN code entry or a PIN code greater than 65,535 is entered, the keypad will clear the PIN code entry buffer, generate a beep and is ready to receive a new 5 digit keypad PIN code. If the entry of the 1 to 5 digit keypad PIN code is disrupted and no number key or "#" key is pressed within 5 seconds, the keypad will clear the PIN code entry buffer, generate a medium length beep and is ready to receive a new 1 to 5 digit keypad PIN code.
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP) Where:
EP = Even parity for first 12 bits. OP = Odd parity for last 12 bits. F = 8-Bit Facility Code. A = 16-Bit code generated from keyboard. Option 6: 6 Keys BCD and parity bits, 26-Bit Wiegand Sends buffer of 6 keys, adds parity and sends a 26-Bit Binary-
Coded Decimal (BCD) message. Each key is a four bit equivalent of the decimal number. The keypad PIN code must be 6 key presses long. On the sixth key press of the 6 digit PIN code, the data is sent across the Wiegand Data lines as a BCD message. AYC-Qx4 family manual Page 20 D = Fourth key entered E = Fifth key entered. F = Sixth key entered If the entry of the 6 digit keypad PIN code is disrupted and no number key is pressed within 5 seconds, the keypad will clear the PIN code entry buffer, generate a medium length beep and is ready to receive a new 6 digit keypad PIN code.
(EP) AAAA BBBB CCCC DDDD EEEE FFFF (OP) Where:
EP = Even parity for first 12 bits. OP = Odd parity for last 12 bits. A = The first key entered. B = Second key entered C = Third key entered Option 7: Single Key, 3x4 Matrix Keypad (MD-P64) This unique mode is intended to let the host controller scan the AYC- F/G/M60 keypad while still keeping the proximity card readers 26-Bit Wiegand or Clock & Data formats active. An optional interface board must be used between the AYC-
F/G/M60 and the host system. Each key press is immediately sent on DATA0 as an ASCII character at a baud rate of 9600 bits per second. When a key is pressed DATA1 is pulled "low" until the key is released at which point DATA1 will be set to "high". This allows the controller to detect the duration of the key press. The MD-P64 interface unit outputs the data received to 7 outputs emulating a keyboard. The interface unit will not affect any data that it receives from the proximity reader whether it is 26-Bit Wiegand or Clock & Data. Key pressed = ASCII Value 0 = '0' ( 0x30 hex ) 1 = '1' ( 0x31 hex ) 2 = '2' ( 0x32 hex ) 3 = '3' ( 0x33 hex ) 4 = '4' ( 0x34 hex ) 5 = '5' ( 0x35 hex ) 6 = '6' ( 0x36 hex ) 7 = '7' ( 0x37 hex ) 8 = '8' ( 0x38 hex ) 9 = '9' ( 0x39 hex )
*= '* ' ( 0x2A hex )
# = '#' ( 0x23 hex ) Page 21 AYC-Qx4 family manual Option 8: 1 to 8 Keys BCD, Clock & Data Buffers up to 8 keys and outputs keypad data without a facility code like standard Clock and Data card output. The keypad PIN code can be one to eight digits long. The PIN code length is selected while programming the reader for Option 8. The reader will transmit the data when it receives the last key press of the PIN code. The data is sent across the two data output lines as binary data in Clock & Data format. If the "*" key or the "#" key are pressed during PIN code entry, the keypad will clear the PIN code entry buffer, generate a beep and is ready to receive a new keypad PIN code. If the entry of the digit keypad PIN code is disrupted and no number key or "#" key is pressed within 5 seconds, the keypad will clear the PIN code entry buffer, generate a medium length beep and is ready to receive a new keypad PIN code. Note:
When using the keypad transmission format "1 to 8 keys BCD, Clock & Data" (Option 8) an additional input is required to specify the number of keys in the PIN code. Option 9: Single Key, 4-bit Wiegand Each key press immediately sends 4 bits of data, with no parity bits added. 0= 0000 1= 0001 2= 0010 3= 0011 4= 0100 5= 0101 6= 0110 7= 0111 8= 1000 9= 1001
*= 1010 ="A" in Hexadecimal
#=1011 ="B" in Hexadecimal Selecting Proximity Card Transmission Format The AYC- F/G/M60 has three different proximity card formats to select from. Follow the steps below to select the appropriate Proximity Card reader transmission format that you wish to use. AYC-Qx4 family manual Page 22 1) 2) 3) 4) Enter Programming Mode. Press 2 to enter Menu 2. The Transmit LED will turn red. Mode/Transmit Door/Program Green 2 Mode/Transmit Door/Program Red Green Enter the appropriate option number for the proxy card transmission format that you wish to select (options below). If an incorrect option is entered the reader will return to Transmit Mode and the keypad transmission format will remain unchanged. System returns to Transmit Mode You will hear three beeps. The Program LED will turn off The Transmit LED will turn red Mode/Transmit Door/Program Red Proximity Card Transmission Format Option Number:
Option 1: 26-Bit Wiegand Option 2: Clock & Data Option 3: Wiegand Card + PIN
"Wiegand Card + PIN" Transmission Format This unique mode is intended to let host controllers get card and keypad data simultaneously. This option overrules the selected Keypad Transmission Format and sends the keypad data as described below. After a card is presented to AYC- F/G/M60, the program LED starts to flash in Green and indicates that AYC- F/G/M60 is waiting for the PIN code. If the entry of one to five digit keypad PIN code is disturbed and no digit key or # key is pressed within 5 seconds, the keypad will clear the card buffer and the PIN code entry buffer, generate a medium length beep and be ready to receive a new card. Page 23 AYC-Qx4 family manual EP =Even parity for first 12 A bits. The keypad PIN code can be one to five digits long in the range of 0 to 99,999. When entering a keypad PIN code, the # key must be pressed to signify the end of the PIN entry. When pressing the #
key press, the data is sent by the Wiegand data lines. If the * key is pressed, the keypad will clear the card buffer and the PIN code entry buffer, generate a medium length beep and is ready to receive a new card. AYC- F/G/M60 output card data in 26-Bit Wiegand with the following keypad data in 26-Bit Wiegand format. Card Data: (EP) AAAA AAAA AAAA BBBB BBBB BBBB (OP) Where:
OP =Odd parity for last B 12 bits. PIN Data: (EP) 0000 AAAA BBBB CCCC DDDD EEEE (OP) Where:
A = The first key entered. B = Second key entered C = Third key entered EP =Even parity for first 12 bits. If the PIN code is less than 5 digits, all the most significant nibbles are filled with 0. Example: (EP) 0000 0000 0000 0000 AAAA BBBB (OP) Where:
A = The first key entered. EP =Even parity for first 12 bits. D = Fourth key entered E = Fifth key entered. OP =Odd parity for last 12 bits. B =Second key entered OP =Odd parity for last 12 bits. AYC-Qx4 family manual Page 24 Changing the Programming Code 1) Enter Programming Mode. Press 3 to enter Menu 3. The Transmit LED will turn red. Enter the new 4 digit code you wish to set as the Programming Code System returns to Transmit Mode You will hear three beeps The Program LED will turn off The Transmit LED will turn red Mode/Transmit Door/Program Green 3 Mode/Transmit Door/Program Red Green
Mode/Transmit Door/Program Red Note:
Programming Code can not be erased, i.e. the code 0000 is invalid and will not erase the Programming Code. The factory default 4-digit Programming Code is 1234. Changing the Facility Code 1) Enter Programming Mode. Press 4 to enter Menu 4. The Transmit LED will turn red. Enter the new 3-digit code yo Code System returns to Transmit Mode You will hear three beeps The Program LED will turn off The Transmit LED will turn red Mode/Transmit Door/Program Green 4 Mode/Transmit Door/Program u wish to s Green Red et a he Fa s t cility Mode/Transmit Door/Program Red 2) 3) 4) 2) 3) 4) Page 25 AYC-Qx4 family manual Note:
Facility Code can be in the range of 000 to 255. The default Facility Code is 0. Setting the Backlight and Reader Format 1) 2) Red Green Green Program Program Program Transmit Transmit Transmit Enter Programming Mode Press "6" to enter menu 6 The Transmit LED will turn red Enter the appropriate option number for the backlight option that you wish to select 10 for always off 11 for always on 12 for 10 sec. backlight after a key is pressed otherwise off 13 for 10 sec. backlight after a key is pressed otherwise dimmed Enter the appropriate option number for the Reader Format 61 for ASK 62 for FSK 63 for ASK + FSK (Default) System returns to Transmit Mode You will hear three beeps The Transmit LED will turn red. Program Transmit Red 3) 4)
Return to Factory Default Settings 1) 2) Warning:
You must be very careful before using this command! This will erase the entire memory and return all codes to their factory default setting. Enter Programming Mode. Press 0 to enter Menu 0. Mode/Transmit Door/Program Green 0 AYC-Qx4 family manual Page 26 Mode/Transmit Door/Program Red Red The Transmit LED will Flash red. The Program LED will flash red. 3) Enter your 4 digit programming code If the Programming Code is valid, all memory will be erased, you will hear three beeps and the controller will return to Normal Mode If the Programming Code is invalid you will hear a long beep and the controller will return to Normal Mode without erasing the memory of the controller
Replacing a Lost Programming Code In the event that the Programming Code is forgotten, the AYC-
Qx4 may be reprogrammed in the field using the following instructions:
1) 2) Activate tamper by removing the reader from the wall or Remove power from the reader. removing the reader's case. 3) Apply power to the reader. 4) You now have 10 seconds to enter Programming Mode using the factory default Programming Code 1234. Page 27 AYC-Qx4 family manual 6. Controller Functionality The AYC- F/G/M60 series can function both as a reader and as a controller. If the unit is connected to Rosslares secure application appurtenance, it functions as a controller indicated by two beeps immediately after power-on reset. The lock strike output and Request to Exit input are not located on the AYC- F/G/M60 unit, eliminating the possibility of unauthorized entry to the restricted area. The following explains how the AYC- F/G/M60 series functions as a controller. 6.1 Normal, Secure, and Master Users The AYC- F/G/M60 accepts up to 500 users and provides entry via the use of PIN codes and/or Proximity cards. Each user is provided with two code memory slots, Memory Slot 1 (Primary Code) and Memory Slot 2 (Secondary Code). The pin code length has several options. The pin code length can be a set number of 4, 5 or 6 digits or it can be a 4-8 digits option. When choosing the 4-8 digit option, please note that you should either enter zeros before the code, or press pound at the end (for example if your code is 12345, enter either 00012345 or 12345#). Note:
Entering a code refers to either PIN or CARD depending on the model you have. The way in which the two memory slots are programmed determines a users access level and also determines the way in which the AYC- F/G/M60 grants access in its three modes of operation. There are three user levels:
Normal User A Normal User only has a Primary Code and is only granted access when the AYC- F/G/M60 is in Normal or Bypass Mode. AYC-Qx4 family manual Page 28 Secure User A Secure User must have a Primary and Secondary Code programmed; the two codes must not be the same. The Secure User can gain access when the AYC- F/G/M60 is in any of its three modes of operation. In Normal Mode the Secure User must use their Primary Code to gain entry. In Secure Mode the Secure User must present both their Primary and Secondary Codes in order to gain entry. Master User A Master User must have both Primary and Secondary Codes programmed with the same code. The Master User can gain access during any mode of operation by presenting their PIN code and/or Proximity card once to the controller. (The Master User is convenient but is less secure than a Secure User.) 6.2 Modes of Operation The AYC- F/G/M60 has three modes of operation:
Normal Mode MODE LED is green Normal Mode is the default mode. In Normal mode the door is locked until a Primary Code is presented to the controller. Special codes such as Lock Strike Code and Auxiliary Code are active in Normal mode. (See pages 35-36 for more information) Bypass Mode MODE LED is orange In Bypass Mode, access to the premises is dependent on whether the controller's Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation. When the Lock Strike is programmed for Fail Secure Operation, the door is locked until the "*" button is pressed. When the Lock Strike is programmed for Fail Safe Operation, the door is constantly unlocked. Mode/Transmit Mode/Transmit Door/Program Door/Program Orange Green Page 29 AYC-Qx4 family manual Red Door/Program Mode/Transmit Secure Mode MODE LED is red Only Secure and Master Users can access the premises during the Secured Mode. A Secure User must enter their Primary and Secondary Codes to gain entry. After entering their Primary Code the Door LED will flash green for 10 seconds, during which the Secondary Code must be entered. A Master User only needs to present their code once to gain entry. Changing the Modes of Operation Changing from Normal Mode to Secure Mode The default factory setting for the Normal / Secure code is 3838. 1) Door/Program Mode/Transmit Enter the Normal / Secure code Mod e LED will flash red s 2) Pre s the # key to confirm the mode change. Mode LED will turn red Green Mode/Transmit Red Mode/Transmit Red Door/Program Door/Program Changing from Secure Mode to Normal Mode The default factory setting for the Normal / Secure 1) Mode/Transmit code is 3838. Door/Program Enter the Normal / Secure code Mod e LED will flash green Press the confirm the mode change. Mode LED will turn green
# key to 2) Mode/Transmi Door/Program Red t G reen Mode/Transmit Door/Program eenGr AYC-Qx4 family manual Page 30 Changing from Normal Mode to Bypass Mode See Changing the Normal / Bypass Code and Door Chime Settings on page 38 to create/modify the Normal / Bypass code. 1) Door/Program Mode/Transmit Enter the 4 digit Normal /
Bypass code Mode LED will flash Orange Press the # key to confirm the mode change. Mode LED will turn orange Green Mode/Transmit Door/Program Orange Mode/Transmit Door/Program Orange Changing from Bypass Mode to Normal Mode See Changing the Normal / Bypass Code and Door Chime Settings on page 38 to c 1) reate/modify the Normal / Bypass code. Door/Program Mode/Transmit Enter the 4 digit Normal /
Bypass co Mode LED will flash de green Press the # key to e mode change. confirm th Mode LED will turn green Orange Mode/Transmit Door/Program Green Mode/Transmit Door/Program Green 2) 2) 6.3 Auxiliary Input & Out For optimum usability in different applications auxiliary input and output can be confi modes of operation. put
, the controllers gured in ten different 6.4 Door Alarm s Door alarms can be gen to a Door Position Switch. conditions are supported, as well as, a configurable delay timer y one for each alarm type. Only one Door-alarm is enabled at an erated by connecting the Auxiliary Input Either Door-Forced or Door-Ajar Page 31 AYC-Qx4 family manual time. Door alarms may activate auxiliary output and siren depending on the auxiliary settings. 6.5 Internal Case and Back Tamper In case the unit is forcibly opened or it is remove sending a tamper event is triggered. A tamper output opens signal to the connected Alarm system (purple wire) the event closes when the tamper is closed (case is re-closed or re-attached to the wall). The tamper event can also activate the auxiliary output if the controller is in Auxiliary Mode 3. Refer to the Quick Reference Guide for Auxiliary Mode Setting table, on page 41 below. d from the wall, a 6.6 Lockout Feature (Keypad / Card Tamper) In case the controller is presented with wrong codes (PIN or consecutively several times the unit goes into lockout mode When a lockout occurs, the controllers reader and keypad are t de-activated so no codes can be entered until the set lockou period expires. During Lockout, Mode LED is Off, Door LED flashes Red, and the controller beeps every two seconds. Card),
. 6.7 Request to Exit (REX) Func tion The REX Button is connected to Rosslares secur appurtenance. The REX Button must be locate premises to be secured and is used to open the door without t use of a PIN code. It is usually located in a convenient loca e.g. inside the door or at a receptionist's desk. The function of the REX Button depends on whether the Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation. Fail Secure Operation: From the moment the REX Button the door will be unlocked until the Lock Strike Release Time has e application d inside the tion, he is pressed, AYC-Qx4 family manual Page 32 passed. After this time, the door will be locked even if the REX Button has not been released. Fail Safe Operation: From the moment the REX Button is pressed, the door will be unlocked until t he REX Button is released, plus the Lock Strike Release Time. In this case the Lock Strike Relay only begins its count down once the REX Button has been released. Secure Application Appurtenances 6.8 Rosslares secure application appurtenances are desi gned for use with Rosslare's secured series stand alone access con trol units, including AYC- F/G/M60. It is designed to operate indoors and installed within the secured premises. The AYC- F/G/M60 must be used with one of Rosslares secure application appurtenances, which prov Request to Exit (REX) Input. Both units communicate through a proprietary Rosslare protocol, between the AYC- F/G/M60 and the which provides a secure link appurtenances unit. This in turn activates the door lock. The units also function as the power supply for the AYC- F/G/M60;
ties. it also contains a speaker connection for all sounder abili For more information see the specific Appurtenances Manual. ide Lock Strike output and he unit's Programming the AYC- F/G/M60 6.9 Programming the AYC- F/G/M60 is done solely via t keypad driven Programming Menu System. To re Programming Menu System the AYC- F/G/M60 must first be placed into Programming mode. See Entering Programmi ng Mode on page 34 for more information. During the AYC- F/G
's manufacturing process certain codes and settings are pre-
programmed. These settings are the called the Default Factory Settings. The table below shows the names of all the AYC-
F/G/M60 Menus. It also shows of all the AYC- F/G/M60s default factory codes and settings. ach the
/M60 Page 33 AYC-Qx4 family manual Programming Menu Menu Menu Description No. Default 6 4-8 digit digit s 5 digit 1 2 3 4 5 6 7 8 9 4 digit Changing Lock Strike Code 2580 25802 258025 25802580 Changing Auxiliary Code 0852 08520 085208 0852085 2 Changing Program Code 1234 12341 123412 12341234 Changing Normal/Secure Code 3838 38383 383838 38383838 Changing Normal/Bypass Code Changing Door Release Time Defining auxiliary inputs/outputs Set Lockout Backlight Behavior Enrolling PIN Code Deleting PIN Code Code assignment w strike/auxiliary Return to factory defau Change PIN code Leng u w ill find a complete descrip o ab ve menu items on the fo tion and instructions or each of llowing pages. N/A 0004 2004 4000 5100 lts /
th ith 0 f Yo the Entering Programming Mode 1) Press the # key twice within 2 seconds. Mode LED will turn off. Door LED will turn red. E er your Programming C nt ode n Door LED will turn gree and the AYC- F/G/M60 will be in Programming M 2) Mode/Transmit Door/Program Red
Mode/Transm it ode
. Doo r/Program Green AYC-Qx4 family manual Page 34 Note:
The AYC- F/G/M60 must be in Normal Mode to enter the Programming mode. The factory four-digit Programming Code is 1234. If a Programming Code is not entered within five seconds, the AYC- F/G/M60 will return to Normal mode. Exiting Programming Mode 1) Press the # key two times within 2 seconds You will hear 3 beeps. Mode/Transmit The Door LED will turn off and the Mode LED will r eturn to Normal. Door/Program Green 2) Wrong entries may re 3) While in Programming mode, if no key is pressed for one minute the AYC-
F/G/M60 will exit Program mode. set the controller back to Normal mode. Mode/Transmit Door/Program Green ming mode and return to Normal used as a method to quickly test ller, the default Lock hanging Lock Strike Code C The Lock Strike Code is mainly the Lock Strike Relay during installation. When the first user is added to the contro Strike Code will automatically be deleted. Once the code is programmed again, it will not be deleted with the entry of additional User Codes. Enter Programming 1) ress 1 to enter Menu 1. P The Mode LED will turn red. Ente as the Lock Strike Code. r the new code you wish to set Mode/Transmit
Mode/Transmit mode. Green Green Red
) 3 2) 1 Door/Program Door/Program Page 35 AYC-Qx4 family manual 4) 3) 4) S ystem returns to Normal mode. You w Mode/Transmit Door/Program Green ill hear three beeps. Note:
Lock Strike Code does not work in the Secure Mode. Wrong entries will return the controller to Normal Mode. Code 0000 will erase the Lock Strike Code. The factory Default 4-digit Lock Strike code is 2580. used as a method to quickly test the controller, the default Auxiliary Changing Auxiliary Code The Auxiliary Code is mainly Auxiliary Relay during installation. When the first user is added to the Code will automatically be deleted. Once the code is programmed again, it will not be deleted with the entry additional User Codes. mode. 1) Enter Programming Press 2 to enter Menu 2. 2) Mode/Transmit Mode/Transmit 2 Green The Mode LED will turn orange. w code you Enter the ne Code. wish to set as the auxiliary System returns to Normal mode. You will hear three Mod beeps. Door/Program Orange Green
e/Transmit Door/Program Green of Door/Program Note:
Auxiliary code does not work in the Secure Mode. Wrong entries will return the controller to Normal Mode. Code 0000 will erase the Auxiliary Code. The factory Default 4-digit Auxiliary Code is 0852. AYC-Qx4 family manual Page 36 Changing the Programming Code 1) Enter Programming mode. Press 3 to enter Menu 3. The Mode LED will turn green. Enter the new code you wish to set as Programming Code System returns to Normal om de. You will hear three beeps. Mode/Transmit Door/Program Green 3 Mode/Transmit Door/Program Green Green
Mode/Transmit Door/Program Green Note:
Programming Code cannot be erased, i.e. the code 0000 is not valid and will not erase the Programming Code. The factory four digit programming code is 1234. Changing the Normal / Secure Code 1) Enter Programming mode. resP s 4 to enter Menu 4 The Mode LED will flash red. Enter the new code you wish to set as Normal / Secure Code System returns to Normal om de You will hear three beeps Mode/Transmit 4 Door/Program Green Mode/Transmit Door/Program Red Green
Mode/Transmit Door/Program Green Note:
Code 0000 will erase the Normal / Secure Code. This code is disabled in case the Auxiliary Input is set to toggle between Normal and Secure access modes. Default Normal/Secure code is 3838 Page 37 AYC-Qx4 family manual 2) 3) 4) 2) 3) 4) Changing the Normal / Bypass Code and Door Chime Settings 1) Door/Program Enter Programming mode. Press 5 to enter Menu 5 The Mode LED will flash orange. 3) Hereafter, are four different Mode/Transmit Green 5 Mode/Transmit Door/Program Orange Green ways to program the normal / bypass code and door chime. a. Disable both Bypass Code and the door chime. Enter the code 0000. 0 0 0 0 b. Disable Bypass Code and enable the c. door chime. Enter the code 0001. Enable Bypass Code and disable the door chime. Enter any code ending with 0. d. Enable Bypass Code and enable the door chime. Enter a code not ending with 0. System returns to its normal mode. You will hear three Mode/Transmit beeps. The Door LED will turn off. The Mode LED will turn green. Green 0 0 0 1
? ? ? 0
? ? ? 0 Door/Program 2) 4) AYC-Qx4 family manual Page 38 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time 1) Door/Program 2) Enter Programming mode. Press 6 to enter Menu 6 The Mode LED will flash green. Mode/Transmit Green 6 Mode/Transmit Door/Program Green Green 3) Construct a code using instructions hereafter. First Digit For fail secure operation, the first digit is set to 0. For failsafe operation, the first digit is set to 1. Second Digit Siren Time in minutes (1-9, 0-disabled) Third and Fourth Digits Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released. For example, 0312 means Fail Secure Operation, a 3-minute Siren, and a 12-second Lock Strike release time. 4) System returns to its normal mode. You will hear three Mode/Transmit beeps. The Door LED will turn off. The Mode LED will turn green. Green
Door/Program Note:
Default value is 0004 which corresponds to Fail Secure operation, no siren, and 4-seconds Lock Strike release time. Page 39 AYC-Qx4 family manual 2) Defining the Auxiliary Input and Output The default auxiliary setting is 2004. 1) Enter the Programming Mode. Press 6 to enter Menu 6. The Mode LED will flash green Mode/Transmit Door/Program Green 6 Mode/Transmit Door/Program Green Green 2 ? ? ?
Auxiliary Mode Auxiliary Setting 3) Construct a code using the instructions below. Auxiliary Mode In addition to the Lock Strike Relay and Lock Strike REX, the AYC- F/G/M60 features an Auxiliary Input. The Auxiliary Mode defines the function of the Auxiliary Input. Auxiliary Settings Each of the Auxiliary Modes has a two digit setting that affects how the Auxiliary Mode functions. 4) System returns to its normal mode. You will hear three beeps. The Door LED will turn off. Mode/Transmit The Mode LED will turn green. Green Door/Program The Second digit defines Auxiliary Input function while the Third and Fourth digits may have no meaning or otherwise they define delay times for door monitor functions. AYC-Qx4 family manual Page 40 Quick Reference Guide for Auxiliary Mode Setting Auxiliary Mode 0 Activated by Valid code or AUX REX Auxiliary Input Function Auxiliary Output AUX REX Auxiliary Relay N.O. 1 2 3 4 5 6 7 8 9 Normal/Secure switch Valid code Normal/Secure switch Star button () Normal/Secure switch Tamper event Normal/Secure switch Door Monitor Door Monitor Door Monitor LED control Green Direct shunt Shunt Forced door Door ajar Valid code LED control - Red Valid code N.O. N.O. N.C. N.O. N.C. N.C. N.C. N.O. N.O. Page 41 Auxiliary Settings
(in seconds) 01 to 99 Aux. relay release time 00 Aux. relay toggle 01 to 99 Aux. relay release time 00 Aux. relay toggle 01 to 99 Aux. relay release time 00 Aux. relay toggle 01 to 99 Aux. relay release time 00 Aux. relay tamper activated 01 to 99 Shunt time 01 to 99 Maximum shunt time 01 to 99 Forced delay 01 to 99 Ajar delay 01 to 99 Aux. relay release time 00 Aux. relay toggle 01 to 99 Aux. relay release time 00 Aux. relay toggle AYC-Qx4 family manual Detailed Reference Guide The following are brief descriptions of each auxiliary mode. To implement the features of each mode, refer to Defining the Auxiliary Input and Output, page 40. Auxiliary Mode 0 Auxiliary input function:
Auxiliary output activated by: Valid user code, Auxiliary code, Auxiliary input E.g. In auxiliary mode 0, the controller can function as a two-door controller. The auxiliary relay is to be attached to the lock on the second door. The auxiliary setting defines the door open time for the second door. The auxiliary input is to be attached to the REX pushbutton for the second door. Door Monitor input feature for the second door is not enabled when using this mode. Activates the auxiliary output Auxiliary Mode 1 Auxiliary input function:
Toggles normal/secure modes Auxiliary output activated by: Valid user code, Auxiliary code E.g. In auxiliary mode 1, the controller can function as a two-door controller. The auxiliary relay is to be attached to the lock on the second door. REX feature for the second door is not enabled when using this mode. The auxiliary setting defines the door open time for the second door. The auxiliary input can switch the mode of operation of the controller between normal and secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from normal mode
(during office hours) to secure mode (after office hours). AYC-Qx4 family manual Page 42 Toggles normal/secure modes Toggles normal/secure modes Auxiliary Mode 2 Auxiliary input function:
Auxiliary output activated by: Asterisk Button (*) E.g. In auxiliary mode 2, the auxiliary relay can function as a general purpose time switch that can be activated when the Asterisk button (*) is depressed. The auxiliary setting establishes for how long the auxiliary relay is to be activated. The auxiliary input can switch the mode of operation of the controller between normal and secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from normal mode (during office hours) to secure mode (after office hours). Auxiliary Mode 3 Auxiliary input function:
Auxiliary output activated by: Alarms E.g. In auxiliary mode 3, the auxiliary output is activated if the controller is tampered; that is, if the case is forcibly opened or removed from the wall. The auxiliary input can switch the mode of operation of the controller between normal and secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from normal mode (during office hours) to secure mode (after office hours). Auxiliary Mode 4 Auxiliary input function:
Auxiliary output activated by: direct shunt (explanation below) E.g. In auxiliary mode 4, the controller is capable of bypassing an alarm zone by shunting an alarm systems door sensor. The auxiliary output is to be wired in parallel to the door sensor output. When in use, the auxiliary output is normally open and the door sensor functions normally. When a valid code is entered, the auxiliary relay shunts the door sensor for the duration of the shunt time, as defined by the auxiliary setting. If the door is left open longer than the shunt time, an alarm will be triggered. Toggles normal/secure modes Page 43 AYC-Qx4 family manual Door Monitor Auxiliary Mode 5 Auxiliary input function:
Auxiliary output activated by: Shunt (explanation below) E.g. In auxiliary mode 5, the controller is capable of shunting an alarm system. In this mode, the auxiliary input is to be wired to the magnetic contact switch on the door. The auxiliary relay is wired to the alarm system. Without a valid code entered, the auxiliary relay will match the condition of the magnetic contact switch; if the door opens, the auxiliary relay will open; if the door closes, the auxiliary relay will close. When a valid code is entered, a count down for maximum shunt time, as defined by the auxiliary setting, begins; if the door is not closed before the maximum shunt time, the alarm will be triggered. Auxiliary Mode 6 Auxiliary input function:
Door Monitor Auxiliary output activated by: Forced entry E.g. In auxiliary mode 6, the controller can trigger the auxiliary relay if the door has been forced. If the Siren Settings is enabled the siren will be activated. In this mode, the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the door. The auxiliary relay is to be wired to the alarm system. If the door is forced open, the controller will wait for the period of the forced door delay time to elapse and then, it will activate the auxiliary relay. The auxiliary setting sets the forced door delay period. Auxiliary Mode 7 Auxiliary input function:
Auxiliary output activated by: Door Ajar (door held open) E.g. In auxiliary mode 7, the controller can trigger the auxiliary relay, if it detects that the door has been held open (ajar) too long. In this mode the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the door. The auxiliary relay is to be wired to the alarm system. If the door is Page 44 AYC-Qx4 family manual Door Monitor opened, the controller will wait for the door ajar delay time to elapse and if the door does not close prior to the end of this period, the controller will activate the auxiliary relay. The auxiliary setting defines the door-ajar time. Auxiliary Mode 8 Auxiliary input function:
Auxiliary output activated by: Valid user code, Auxiliary code E.g. In auxiliary mode 8, the controller can function as a two-door controller and also provide indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the door open time for the second door. The auxiliary input is used to control the Door indicator. If the auxiliary input is open, the indicator will flash green; if the auxiliary input is closed, the Door indicator will flash red. Green LED control Note:
1. This mode takes control of the Door indicator LED. 2. The indicator LED will not be lit when:
3. A valid code is entered 4. While in secure mode, when waiting for secondary code. Red LED control Auxiliary Mode 9 Auxiliary input function:
Auxiliary output activated by: Valid user code, Auxiliary code E.g. In auxiliary mode 9, the controller can function as a two-door controller and also provide indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the door open time for the second door. The auxiliary input is used to control the indicator. If the auxiliary input is open the Door indicator will flash red; if the auxiliary input is closed the Door indicator will flash green. Note:
1. This mode takes control of the Door indicator LED. 2. The indicator LED will not be lit when:
3. A valid code is entered 4. While in secure mode, when waiting for secondary code. AYC-Qx4 family manual Page 45 Setting the Lockout Feature In case the controller is presented with wrong codes, consecutively several times the unit goes into lockout mode. When a lockout occurs, the controller keypad and reader are locked so no codes can be entered until the set lockout period expires. During Lockout, Mode LED is Off, Door LED flashes Red, and the controller beeps every two seconds. The default setting for the Lockout Feature is 4000 (Lockout Disabled) Note:
1. Using the lockout feature is highly recommended, especially when selecting to use short PIN code length (4 or 5 digits). Mode/Transmit Door/Program Green 6 Mode/Transmit Door/Program Green Green 4 ? ? ?
1) 2) Enter the Programming Mode. Press 6 to enter Menu 6. The Mode LED will flash green 3) Construct a code using the following instructions:
Set the number of wrong code attempts, which will cause Lockout between 0 and 9 attempts. Sets the Duration of the lockout, between 00 and 99, the value is multiplied by ten, resulting in 0-990 seconds. AYC-Qx4 family manual Page 46 Setting the backlight behavior The controller allows you to define the way the units' Backlight will work. To define the Backlight operation:
1) 2) Depress 6 to enter Menu 6. Enter the programming mode. Mode Door Green Green The Mode indicator will flash green. 3) Construct a code using the following instructions:
the backlight and Led option and the type of activity are 50 - Backlight Off 51 - Backlight On (default) 52 - Backlight Off, activated on any key press for ten seconds. 53 - Backlight Dimmed, backlight activated on any key press for ten seconds. 4) Under Menu 6, format the controller using the following instructions:
61 ASK 62 FSK 63 ASK + FSK (Default) Enrolling Primary and Secondary Codes Primary Codes Primary Codes can only be enrolled to an empty User Slot, i.e. a slot where there is no existing Primary Code. Primary Codes must be unique, i.e. one users Primary Code may not be the same as other users Primary Code. Primary Codes cannot be the same as any system codes, such as the Normal / Secure Code or Lock Strike Code. Users who hold a Primary Code can gain entry only during Normal mode. Page 47 AYC-Qx4 family manual Secondary Codes Secondary Codes can only be enrolled to User Slot that already has a Primary Code enrolled but no Secondary Code. Secondary Codes do not have to be unique, i.e. multiple users can all hold the same Secondary Code. Secondary Codes cannot be the same as any system codes, such as the Normal / Secure Code or Lock Strike Codes. Users who hold Secondary Codes can gain entry in any Mode of Operation. Enrolling Primary and Secondary Codes There are two methods to enroll Primary and Secondary codes, the Standard Method and the Code Search Method. The Standard Method is mainly used when the User Slot number for the user you wish to program is known. You can program both Primary and Secondary Codes using the Standard method. (See Enrolling Primary and Secondary Codes using the Standard Method on page 48.) The Code Search Method is mainly used when enrolling a users Secondary Code and the User Slot Code is unknown. The Code Search method only works if a users Primary Code is already enrolled but the Secondary Code is not. (See Enrolling Secondary Codes using the Code Search Method on page 50.) Enrolling Primary and Secondary Codes using the Standard Method AYC-Qx4 family manual Page 48 1) 2) 3) 4) Enter the Programming Mode. Press 7 to enter Menu 7. The Door LED will turn orange er the 3-di Mode/Transmit Door/Program Green 7 Mode/Transmit Door/Program Orange
Door/Program Mode/Transmit Green Orange git User Slot number Ent between 001 and 500 that you wish to enroll a Primary or Secondary code to. For example, User Slot 003 represents User #3. If the selected slot has no Primary Code, the Mode LED will flash green, indicating that the controller is ready to accept a Primary Code. If the selected slot already has a Primary Code but no Secondary Code, the Mode LED will flash red, indicating that the controller is ready to accept a Secondary Code. If the selected slot already has a Primary and Secondary Code, you will hear a long beep and the controller will return to Normal Mode. er the PIN Code you wish Red Orange Mode/Transmit Door/Program Door/Program Mode/Transmit Ent to assign as the Primary or Secondary Code for this slot number. Green If the code entered is valid the Mode LED will stop flashing and then the controller is ready for you to enter the next 3-digit slot number (refer to step 2) that you want to assign a code to, or press the # key to move to the next slot number. If you do not wish to continue enrolling codes, press the # key twice and the controller will return to Normal mode. Page 49 AYC-Qx4 family manual Enrolling Secondary Codes using the Code Search Method The Code Search feature enables you to quickly enroll a Secondary Code to a user who already has a Primary Code. 1) Door/Program Enter the Programming Mode. 2) Press 7 to enter Menu 7. Mode/Transmit Green 7 3) The Door LED will turn orange Enter 000 as the 3-digit User Slot number. The Door LED will flash orange. Mode/Transmit Door/Program Orange 00 0 Mode/Transmit Door/Program Orange ode. Mode/Transmit The controller is now waiting for the Primary Code of the User to whom you want to add a Secondary Code. 4) Enter the Primary Code belonging to the user for whom you wish to add a Secondary C ode LED will flash ary Code entered is not valid, you will hear a long beep The M red. If the Prim and the AYC- F/G/M60 will continue to wait for a valid Primary Code. En 5) ter the Code to be used as the Secondary Code. If the Secondary Code is valid, the controller will b three times and return to Normal Mode. If the Secondary Code is invalid the cont roller will sound a long beep, and the AYC- F/G/M60 will continue to wait for a valid Secondary Code to be entered. Red Orange Door/Program eep AYC-Qx4 family manual Page 50 Deleting Primary and Secondary Codes There are two methods to delete Primary and Secondary codes:
the Standard Method and the Code Search Method. When deleting a User Slot, both the Primary Code and the Secondary code are erased. Deleting Primary and Secondary Codes using the Standard Method 1) Door/Program Enter the Programming Mode. Press 8 to enter Menu 8. The Door LED will turn orange The Mode LED will turn red Mode/Transmit Green 8 Mode/Transmit Door/Program Red Orange
Enter the 3-digit User Slot code you wish to delete. The Mode LED will flash red Indicating the controller is waiting for Red Orange the Programming Code to confirm the deletion. If the User Slot is empty, you will hear a long beep and the AYC- F/G/M60 will return to Normal Mode. Mode/Transmit Door/Program Enter your programming code to confirm the deletion. If the programming code is valid, three beeps will be heard and the controller will return to its normal mode. If the programming code is invalid, a long beep will be heard and the controller will return to its normal mode.
Note:
It is recommended that a record be kept of added and deleted users so that it will be easier to keep track of which user slots are empty and which user slots are not. AYC-Qx4 family manual Page 51 2) 3) 4) 2) 3) Deleting Primary and Secondary Codes using the Code Search Method 1) Door/Program Enter the Programming Mode. Press 8 to enter Menu 8. The Door LED will turn orange The Mode LED will turn red Enter 000 as the 3-digit User Slot number. The Mode LED will turn red. The Door LED will flash orange. Mode/Transmit Green 8 Mode/Transmit Door/Program Red Orange 00 0 Mode/Transmit Door/Program Red Orange The controller is now waiting for the Primary Code of the User you want to delete. 4) Enter the 4-8 digit PIN Code of the Primary Code belonging to the user you want to delete.
The Mode LED will flash red The Door LED will flash orange Mode/Transmit Door/Program Red Orange Enter your Programming Code to confirm the deletion. 5) If the Programming Code is valid, you will hear three beeps and the unit will return to Normal Mode. If the Programming Code is invalid, you will hear a long beep and the unit will return to Normal Mode. Note:
It is recommended that a record be kept of added and deleted users so that it will be easier to keep track of which user slots are empty and which user slots are not. AYC-Qx4 family manual Page 52 Relay Codes Assignment When a primary code is enrolled for any user, the user is authorized to activate the Lock Strike relay. However, different user codes may be set to operate the auxiliary relay instead or operate both the Lock strike and auxiliary relay. Assignment of such codes is achievable for any valid user code entered in the controller. There are two methods to assign relay codes to users: a standard method and a search method. Relay Code Assignment using Standard Method 1) Enter the programming mode. 2) Depress 9 to enter Menu 9. Mode/Transmit Green Orange Mode/Transmit The Mode LED will turn green. The Door LED will turn orange. Enter the 3-digit user slot for code assignment. Enter the assignment digit for the current user slot:
1 will activate the Lock Strike relay only deafult The Mode LED will flash green.
Green Orange 3) 4) Mode/Transmit Mode/Transmit Door/Program Door/Program 2 will activate the Auxiliary relay only 3 will activate the Lock Strike and Auxiliary relays. If the assignment code is valid, the Mode indicator will stop flashing. The controller is now waiting for another slot number. Depress the
# key to move to the next slot or enter a new slot number. If you do not wish to continue, depress the # key twice and the controller will return to its normal mode. Door/Program Green 9 Door/Program Page 53 AYC-Qx4 family manual Relay Code Assignment using Search Method 1) Mode/Transmit Mode/Transmit Enter the programming mode. 2) Depress 9 to enter Menu 9. Mode/Transmit The Mode LED will turn green. The Door LED will turn orange. Enter 000 for user slot access. The Door LED will flash orange. Door/Program Green 9 Door/Program Green Orange 0 0 0 Mode/Transmit Door/Program Green Orange The controller is now waiting for the primary code of the user. Enter the primary code belonging to the user. Green Orange Mode/Transmit Door/Program The Mode LED will flash green. Enter the assignment digit for the current user slot:
1 will activate the Lock Strike relay only deafult 2 will activate the Auxiliary relay only 3 will activate the Lock Strike and Auxiliary relays. If the assignment digit is valid, three beeps will be heard and the controller will return to its normal mode. If the assignment digit is invalid, a long beep will sound and the controller will wait for another assignment digit to be entered. 3) 4) 5) AYC-Qx4 family manual Page 54 Pin Code Length / Factory Default Settings Warning:
You must be very careful before using this command!
Changing the pin code length will also erase the entire memory contents, including all user and special codes, and return all codes to their factory-default settings Mode/Transmit Enter the Programming Mode. Select the desired pin code length as follows:
00 Returns to factory defaults and sets a 4 digit code. 05 - Returns to factory defaults and sets a 5 digit code. 06 - Returns to factory defaults and sets a 6 digit code. 08 - Returns to factory defaults and sets a 4-8 digit code. Green Door/Program Note:
2. When choosing the 4-8 option, please note that you should either enter zeros before the code, or press pound at the end (for example if your code is 12345, enter either 00012345 or 12345#). Both the Mode and Door LEDs will flash red. Enter your 4-8 digits Programming Code. Mode/Transmit Mode/Transmit Red Red Door/Program Door/Program
If the Programming Code is valid, all memory will be erased. You will hear three beeps and the controller will return to Normal Mode. If the Programming Code is invalid you will hear a long beep and the controller will return to Normal Mode without erasing the memory contents. 1) 2) 3) Page 55 AYC-Qx4 family manual Replacing a Lost Programming Code Note:
The AYC- F/G/M60 must be in Normal mode, otherwise this will not work. Make sure that the Mode LED is green before proceeding. Remove power from the Power Supply Unit. Press the REX Button on the Power Supply Unit. 1) 2) 3) Apply power to the unit with REX button pressed. 4) 5) Release the REX Button. You now have 15 seconds to program a new Programming code into the Access Control unit using the default code based on the PIN code length you chose (see Programming Menu on page 34), before the controller reverts to the existing code. Replacing a Lost Normal / Secure Code Note:
The AYC- F/G/M60 must be in Secure Mode, otherwise this will not work. Make sure that the Mode LED is red before proceeding. Remove power from the Power Supply Unit. Press the REX Button on the Power Supply Unit. 1) 2) 3) Apply power to the unit with the REX button pressed. 4) 5) Release the REX Button. You now have 15 seconds to program a new Normal /
Secure code into the Access Control unit using the default code based on the PIN code length you chose (see Programming Menu on page 34), before the controller reverts to the existing code. AYC-Qx4 family manual Page 56 Appendix A. Limited Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) FIVE YEARS LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's FIVE YEARS LIMITED WARRANTY is subject to the following conditions:
Warranty Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable. Products Covered By This Warranty and Duration ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the AYC-Qx4, metal convertible reader / secured controller family as listed above, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 5 years (60 Months). Warranty Remedy Coverage In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARYS sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center. Page 57 AYC-Qx4 family manual Exclusions and Limitations ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE. This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages. Limited Warranty Terms THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND ITS SUBSIDIARY'S WARRANTY THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE. THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE SPECIFICALLY EXCLUDED. IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF USE, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS, ARISING OUT OF THE INSTALLATION, USE, OR INABILITY TO USE SUCH PRODUCT, TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW. THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY. AYC-Qx4 family manual Page 58 FCC NOTE This device complied with Part15of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. Page 59 AYC-Qx4 family manual Appendix B. Technical Support Asia Pacific, Middle East, Africa Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com United States and Canada 1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com Europe Global Technical Support & Training Center HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com South America Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228 E-mail: support.la@rosslaresecurity.com Web Site: www.rosslaresecurity.com AYC-Qx4 family manual Page 60
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-03-15 | 0.125 ~ 0.125 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-03-15
|
||||
1 | Applicant's complete, legal business name |
Rosslare Enterprises Ltd
|
||||
1 | FCC Registration Number (FRN) |
0008472821
|
||||
1 | Physical Address |
Room 905
|
||||
1 |
Kowloon Bay, Kowloon, N/A
|
|||||
1 |
Hong Kong
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
GCD
|
||||
1 | Equipment Product Code |
AYC-G60
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J****** L********
|
||||
1 | Title |
Engineering Manager
|
||||
1 | Telephone Number |
847-8********
|
||||
1 | Fax Number |
847-8********
|
||||
1 |
j******@rel-napdc.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | CONVERTIBLE READER AND CONTROLLER | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Waltek Services(Shenzhen) Co., Ltd.
|
||||
1 | Name |
P****** z******
|
||||
1 | Telephone Number |
0086-********
|
||||
1 | Fax Number |
0086-********
|
||||
1 |
p******@waltek.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC