Doc. - Ref. 230-XT Last modification date : June 2019 Firmware version : XLP.04.04.05.XXX and later XT 210/640/730 GPRS Control PanelINSTALL MANUALwww.videofied.com Introduction Description The XT is a fully wireless alarm system. It can be powered by standalone batteries or connected to a power supply. This panel is intended mainly for residential and commercial markets. With the Motion Viewers and Videofied range of products, the XT panel provides video verification in case of intrusion. The XT panel has three wired programmable inputs and two wired programmable outputs. Thanks to the Mapping feature, the programmable inputs can be configured to trigger a video. For specific applications, the XT alarm system offers the possibility to increase its Radio and/or GPRS performances through the connection of externally wired antennas. Technology The XT alarm panel, like all Videofied devices, uses the S2View patented technology. Which is an interactive wireless and AES encrypted technology ensuring signal integrity and optimal security. The reliability of the signal is guaranteed thanks to the two-way radio frequency transmissions with all the peripherals of the Videofied product line. The integrated antennas allow the system to be totally wireless, thus preventing from the system beeing inelegant and cumbersome, and eliminating the installation problems. The jamming detection feature identifies any intentional jamming from a third party. On the other hand, the supervision feature consists of transmitting signals between every device of the system and the alarm panel XT. Through the supervision, the detectors transmit every 8 minutes a presence signal. The entire RSI VIDEO TECHNOLOGIES team wishes you a successful installation. 2 www.videofied.comINSTALL MANUAL Summary Introduction............................................................................................................2 Summary...................................................................................................3 1. XT Panel setup...................................................................................................4 installation...............................................................................................4 1.1 SIM card 1.2 Panel mounting.........................................................................................................4 1.4 Powering and initialization........................................................................................5 1.5 Pairing the keypad....................................................................................................6 2. XTENDER Mode.........................................................................................................7 3. XT Panel programming...............................................................................................8 XTENDER mode configuration.........................................................................................13 4. XT features guide.....................................................................................................15 4.1 Get to access level 4...............................................................................................................15 4.2 How to Arm/Disarm the system.................................................................................................15 4.3 Arming and Siren Mode Configuration...............................................................................16 4.4 Manage badges and access codes..........................................................................................17 4.5 Delete the keypad or any other device.....................................................................................19 4.6 Read the event log...................................................................................................................20 4.7 Programmable inputs and outputs...........................................................................................20 4.8 Golden rules...............................................................................................................................21 5. Transmitted events list.............................................................................................22 6. 2G3G error codes....................................................................................................23 7. Technical specification and security notes...........................................................24 3 www.videofied.comINSTALL MANUAL 1. XT Panel setup 1.1 SIM Card Installation Before removing the front cover from its box, Put the SIM card on the plastic base (Take care to respect the right direction). DO NOT insert or remove the SIM card while the panel is powered. 1.2 Panel mounting Fix the back casing on the wall using the three mounting holes as shown. Mounting the panel is not required for programming. Bracket holes 4 www.videofied.comINSTALL MANUAL 1. XT Panel setup 1.3 Powering and initialization The panel is powered either with a mains power supply with 4 backup LR20 Alkaline batteries (Option 1 recommended) or with 4 LSH20 Lithium batteries (Option 2). Press and hold the PROGRAMMING BUTTON for 10 seconds, until the indicator LED blinks twice. The panel is now reset, a CMA, XMA or XMB has to be enrolled to configure the panel. THE CONTROL PANEL MUST BE CONNECTED TO AN EXTERNAL POWER SUPPLY (OPTION 1) WHEN USING THE RINGTONE FEATURE OR SMARTPHONE APP. Option 1 Option 2 Programming button Mains power supply 5 www.videofied.comINSTALL MANUAL 1. XT Panel setup 1.4 Pairing the remote keypad Press the XT programming button and release for the enrollment of a programming keypad. Insert all LS14500 Lithium batteries into the keypad. Do not mount the keypad. It will display one of the following screens:
RSI (c) 2013 videofied.com or
<=========XX=========>
Press on both CLR and ESC NO keys at the same time and release. The indicator LED on the keypad will blink rapidly. Wait for the keypad to pair. If the keypad doesnt pair up with the panel and shows XX, it certainly means that it is still paired to another system and needs to be reset. Take the batteries out, and press repeatedly on the keypad tamper switch. Then proceed to the above steps. 6 www.videofied.comINSTALL MANUAL 2. XTENDER Mode The XT panel can be used as standard standalone alarm system but it can also be connected to an existing alarm system capable of latching a 9-12Vcc* voltage used for its arming/disarming. 2.1 Standalone Mode In this functioning mode, the XT panel works as a standard hybrid alarm system with 25 wireless peripherals and 3 programmable inputs. It is a totally standalone alarm system. 2.2 XTENDER Mode (From the host) Existing Host Panel Arming O/P 2 Arming O/P 1 When the XT panel is used in XTENDER mode, the system will only be able to arm and disarm by latching 9-12Vcc to its arming inputs Arming Input 1 and/or Arming Input 2. When the voltage switches to 0V, the panel will disarm automatically. On a programed panel, you can choose between standalone and XTENDER modes from the menu :
CONFIGURATION (LVL 4) > GENERAL PARAMETERS > XTENDER
*When using an XT in XTENDER mode, the panel has to be powered by the mains power supply. 7 www.videofied.comINSTALL MANUAL 3. XT Panel Programming Keypad Display KEYPAD 1 RECORDED OK or YES
< - LANGUAGE : - >
ENGLISH (UK) for language selection OK or YES RADIO RANGE TEST?
OK or YES RF TEST x/9 Please wait RF TEST 9/9 OK or YES RADIO RANGE TEST?
ESC NO INSTALLER CODE 4 TO 6 DIGITS THEN OK/YES INSTALLER CODE :
OK or YES CONFIRM CODE OK or YES Actions and comments The system can also be programmed in: french, italian, german, dutch, spanish, swedish, portuguese, danish, czech and polish. The language can be changed at any time once the panel is programmed in the MAINTENANCE menu. The Radio Range test must be run during the device learning process in order to ensure proper pairing with the control panel. This test measures the strength of communication between the device and the control panel. The keypad will display a real time radio range value on a scale of 9. To receive the most accurate results you must run the radio range test for at least 30 seconds. Result must be 8 out of 9 or better for reliable transmission. Using the Alphanumeric Keypad, enter the Installer Code of your choice. The Installer Code will be used for all future maintenance and configuration. This code is important to keep track of. There is no back door or Default codes to the system. Please refer to the restriction rule for codes (Chapter 4.4). Some codes are already used by default and therefore cannot be used. 8 www.videofied.comINSTALL MANUAL 3. XT Panel Programming Keypad display Actions and comments You may name the installer code using the Alphanumeric Keypad. If using automatic setting (called installer default list), enter the name of the list. Warning : If the wrong installers list name is used it cannot be set later, the system must be defaulted. Leaving the name blank by pressing ESC NO, it will be named ACCESS 1 by default. CODE NAME :
OK or YES ACCESS 1 REGISTERED Please wait ADJUSTING DATE AND TIME DATE (YEAR):
12/ /
To set the year OK or YES DATE (MONTH):
13/01/
To set the month OK or YES You may proceed in the same way for:
Day, Hour and Minutes. 13/10/14 10:47 ENTRY COMPLETE !
CONNECTED TO MONITOR. STATION?
OK or YES ESC NO ACCOUNT NUMBER :
ACCOUNT NUMBER :
567001 OK or YES Use the Alphanumeric Keypad to enter in a 4-8 digit account number provided by the Central Station. 9 www.videofied.comINSTALL MANUAL 3. XT Panel Programming Keypad display PERIODIC TEST PERIODIC TEST :
24 HOURS To select periodicity OK or YES TEST (hour) :
04:
OK or YES TEST (minutes) :
04:15 OK or YES CODE/STATE MODIFICATION?
OK or YES CODE/STATE CODE/STATE MODIFICATION MODIFICATION Wait ESC NO Events list ESC NO SERVER ADDRESSES ?
OK or YES Actions and comments Test Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days or no tests. We suggest a 24 hours periodic test call. The CODE/STATE MODIF. menu is to configure the transmitted events to the monitoring station, use the arrow keys to toggle between events and OK or YES to modify. ALARM: event transmitted upon occurrence. ALARM/END: event is transmitted on occurrence and on event restoral. NOT TRANSMITTED: event is not transmitted, however it will appear on the keypad. Please liaise with your Monitoring Station to ensure that the requested events to transmit are correctly set. 10 www.videofied.comINSTALL MANUAL 3. XT Panel Programming SERVER ADDRESSES ?
OK or YES IP1 ADDRESS 0.0.0.0 ESC NO SERVER ADDRESSES ?
ESC NO 2G3G PARAMETERS ?
OK or YES APN CODE internet-entrepr 2G3G PARAMETERS ?
ESC NO 2G3G LEVEL ?
DOMAIN NAME 1 PORT 1 888 The IP1 address, Domain name 1 and/or Port 1 are provided by the monitoring station. Leave Port details at 888 unless otherwise instructed. Press OK or YES to enter/modify the parameter then OK or YES for validation. WARNING : You will use either an IP address or a Domain name but not both, leave the Domain name blank if an IP address has already been entered. Press on the right arrow to configure IP/Domain name 2 and PORT2 (for the back-up server), and IP/Domain name TMT and PORT TMT (to configure remote maintenance server). USER NAME orange PASSWORD orange The APN Code (Access Point Name), User Name and Password are supplied by the mobile operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator. Press OK or YES to enter/modify the parameter then OK or YES for validation. Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! It makes a difference between UPPER and lower case letters. To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key (0-9) for XMA/XMB. 11 www.videofied.comINSTALL MANUALESCNO 3. XT Panel Programming 2G3G LEVEL ?
OK or YES TEST IN PROGRESS END = OK/YES 2G3G LEVEL 5/5 OK or YES 2G3G LEVEL ?
ESC NO COMPATIBILITY EN 50131 NORMS ?
OK or YES ESC NO AREAS CONFIGURATION OK or YES AREA 1 NAME :
OK or YES ARMING PROFILE :
STANDALONE OK or YES EXIT DELAY :
45 sec For the selection OK or YES ENTRY DELAY :
15 sec For the selection Please go to page 14 if you chose STANDALONE ARMING PROFILE :
FROM THE HOST Please go to page 13 if you chose FROM THE HOST Once the 2G3G test completed, the keypad will display one of the following results :
- A level between 0/5 and 5/5.
- A GPRS Error code (please see Chapter 6 : 2G3G errors codes and contact your technical support). If the screens shuts down, press any key to light it up except OK or YES, ESC NO or CLR. The 2G3G level test can last several minutes. Do not interrupt the test or remove the SIM card during the test. IMPORTANT : Videofied will require a 3/5 grade or better for reliable transmission of Video alarms. For full compatibility with EN50131, press OK or YES. Otherwise, press ESC NO. Press ESC NO to default the area names. Enter the name of the area 1 and OK or YES. Repeat the procedure for areas 2,3 and 4. For further details, please refer to chapter 4.3. Your choice will depend on how you are arming the system :
Standalone : Will make the XT a completely independent system controlled by arming and disarming using Videofied peripheral devices(keyfobs, keypads, badge,readers). From the host : Will make the XT panel a piggyback/xtender system that will only arm and disarm off the latching of 9-12V on the arming inputs 1 & 2. Other values are available: 2 min, 1 min, 45 sec. Other values are available: 2 minutes, 1 minutes, 45 seconds,30 seconds or 15 seconds. 12 www.videofied.comINSTALL MANUAL 3. XT Panel Programming XTENDER mode configuration ARMING PROFILE :
FROM THE HOST OK or YES ARMING MODE MODE :
SLOW OK or YES ENTRY DELAY VALUE (0-255) :
(000) : _ OK or YES TRANSMISSION DELAY VALUE (0-600) :
(000) : _ OK or YES ARMING CONFIRMATION VALUE (0-240) :
(0) : _ MODE SLOW : The panel will arm each device one at a time saving battery life. This mode is recommended. MODE FAST : The panel will arm all devices at the same time. This mode increases significantly the battery consumption. OK or YES to choose the parameter. MODE :
FAST Enter the value for your Entry Delay up to 255 seconds and press OK or YES. Note : In From the Host mode, the entry/exit delay are dealt by the master system. The transmission delay value set the delay between the detection of an event and its transmission to the monitoring center. Except when specifically required, please enter 0. Enter the value you would like for the Transmission Delay and press OK or YES. Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input. This feature can be used as an exit delay, we suggest you to enter the same value as your master system exit delay. Enter the value you would like for the Arming Confirmation and press OK or YES. For further information about the programmable inputs and outputs, please consult the following application notes available on our support website:
240-XT - APP NOTE - XTENDER CONFIGURATION MODE 13 www.videofied.comINSTALL MANUAL 3. XT Panel Programming RECORDING DEVICES PRESS PROGRAM BUTTON OF DEVICE ENTERING A NEW DEVICE ?
ESC NO BADGE ENTERED ?
ESC NO OK or YES RECORDING A NEW BADGE ?
ESC NO END OF CONFIGURATION Each device has a unique programming button or a specific manipulation. Please refer to the Installation Sheet for the device you would like to program. Please check the radio level of each device on its final location. The result must be 8 out of 9 as a minimum (please refer to the Radio Range section, page 8 for further details). Each system can embrace a maximum of 25 devices, programming keypad included. Press OK or YES to enter a new device or ESC NO to move to the next step. After initial programming has been completed, the system cannot be armed or disarmed until a user code or badge is entered (the installer code cannot arm or disarm the system). Press OK or YES to register one or more badges. ESC NO if youre not using any badges. If you wish to use an user code, please skip this step and once the system configuration done go to the BADGES/ACCESS CODES menu (please refer to chapter 4.4 for further details). Badges and codes are limited to 19 for user (level 2 or 3) + 1 installer code. OPERATION COMPLETED ?
OK or YES SYSTEM CHECK IN PROGRESS INSTALLATION SUCCESSFUL !
Before completing programming make sure that no device is tampered. Each device must be closed and its LED indicator shall be turned off. After initial programming has been completed, make use of the menu overview document (available on our technical support website), to see full programming options. 14 www.videofied.comINSTALL MANUAL 4. XT features guide 4.1 Get to Access level 4 Tue 29/10 DISARMED 11:23 LVL:1 ACCESS LEVEL 1 OK or YES ACCESS LEVEL LEVEL : 1 To unlock and get access to the installer level 4, you need to successively enter TWO codes
(in any order) :
INSTALLER CODE (entered during intial programming) USER CODE (Level3): the user must authorize the installer to get access to the configuration of his panel. ACCESS LEVEL LEVEL : 4 OK or YES BADGE OR CODE OK or YES 4.2 How to Arm/Disarm the System When in standby mode, the system can be armed with the remote keypad, the remote keyfob and/or the remote badge reader. Full arming with personal code Full arming with badge Special Arming 1 Special Arming 2 With remote keypad Enter your user code and press OK or YES Present your badge on Press
/
Press
/
the keypad
( XMB model only) enter your user code and press OK or YES press OK or YES and enter your user code With remote badge reader BR250 With remote keyfob N/A N/A Present your badge on the badge reader N/A N/A N/A Press Press 15 www.videofied.comINSTALL MANUAL 4. XT features guide 4.3 Arming and Siren Mode Configuration Use the to go to menu :
CONFIGURATION (LEVEL 4) > SPECIAL ARMING MODES > FULL ARM, SP1 or SP2 use direction arrows to select the arming mode you want to modify and OK / YES. There are 3 different arming modes :
FULL ARM : Arming of all areas and all devices. Use a badge or a user code and press OK / on the XMA/XMB keypad or the YES key on the CMA keypad. SP1 : Partial Arming (1) is enabled by entering the user code and pressing on the XMA/XMB keypad, the key on the CMA keypad or on the remote keyfob RC. SP2 : Partial Arming (2) is enabled by pressing the key on a XMA/XMB keypad, on a CMA keypad, or on the remote keyfob RC. For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm. Areas :
1 2 3 4 State :
A A A A Each time you press the corresponding number, the system will toggle the arming state for the respective area. Press OK / YES after this configuration step. The system will then display what siren mode will be in effect for this special profile. Select the siren mode using the direction arrows then press OK / YES. A D P E Armed Disarmed Perimeter
(by default : all opening contacts*) External
(by default : all opening contacts with external access*) Siren Immediate triggering of all sirens Delay Beeps Entry/Exit delay beeps, then triggering of all sirens Silent No Sirens, No Beeps Without Siren Beeps on the keypad only
* You can set your devices as : External, Perimeter, ou External +Perimeter. Please go to the menu:
CONFIGURATION (LVL 4) > AREAS AND DEVICES > DEVICES > DEVICES CONFIGURATION > DEVICE TYPE When in the Arm From Host mode, the Videofied system will only arm and disarm when 9-12v is supplied and sustained. When both arming inputs are supplied voltage at the same time the Videofied Keypad display will show SYSTEM ARMED. When only one arming input is supplied voltage the Videofied Keypad display will show PART LVL #
Arming Input 1 will arm/disarm Areas 1 & 2 Area 1 is delayed by default Arming Input 2 will arm/disarm Areas 3 & 4 Area 3 is delayed by default 16 www.videofied.comINSTALL MANUAL 4. XT features guide 4.4 Manage badges and access codes Access Level Access Level Definition & Rights LVL 1 LVL 2 LVL 3 LVL 4 Standby Level Restricted USER level, where it is only possible to arm/disarm the system. USER level, where it is possible to arm/disarm the system, check the event log, test the devices. Modifications of the settings are not possible at this level. User Level 3 can create Level 2 or Level 3 access codes or badges. INSTALLER level, where it is possible to modify the setup of the panel. To access Level 4, the approval of a Level 3 oe Level 2 user is required. Installer Level 4 can create the first Level 3 access code only. Codes and badges get rights access to one of the 4 available levels of access. How to return to the LVL1?
After 1 min of no use of the keypad and no tests running, the display returns to the standby display and LVL1. When standby display, if the ESC NO key is held during 5s, the level is changed to LVL1. 17 www.videofied.comINSTALL MANUAL 4. XT features guide Enter a new end user Badge/Code Delete an end user Badge/Code BADGES ACCESS CODES OK or YES ENTER A BADGE/CODE OK or YES BADGE OR CODE Enter a 4-6 digit user code and OK or YES or present a badge in front of the reader until you hear the registration beep. CONFIRM THE CODE OK or YES CODE NAME :
OK or YES ACCESS 2 ENTRY COMPLETE ENTER A BADGE/CODE Press twice on the right arrow DELETING BADGES/CODES OK or YES Badges/codes list Select badge/code then OK or YES DELETING CODE ACCESS 5 OK or YES CODE DELETED Reserved Codes Up to 19 codes (or badges) can be registered into the panel with the engineer code. A code has 4 to 6 digits (0 to 9). The table presents the reserved code possibilities that cannot be used. Those codes are used for maintenance or as panic/duress codes. A total of 186 codes are forbidden. Reserved Codes 000000 From 9998 to 9999 From 99998 to 99999 From 999898 to 999999 From 314157 to 314159 All user codes +1 All user codes +2 All user codes -1 All user codes -2 When a code is created (1000 for example), the 2 next codes and previous codes (0998, 0999, 1001 and 1002) will be automatically reserved. The +1 code (1001) is used for disarming under duress. The +2 code (1002) is used for panic. The -1 and -2 codes (0998 et 0999) are reserved to prevent conflicts when creating a new user code. 18 www.videofied.comINSTALL MANUAL 4. XT features guide 4.5 Delete the keypad or any other device ACCESS LEVEL 4 CONFIGURATION OK or YES GENERAL PARAMETERS AREAS AND DEVICES OK or YES DEVICES OK or YES ADD A NEW DEVICE DEVICE CONFIGURATION OK or YES Devices list to select the device and press OK or YES A1 : KEYPAD KEYPAD 1 OK or YES DELETE OK or YES
< = = = = XX = = = = >
You can now remove the batteries from the device 19 www.videofied.comINSTALL MANUAL 4. XT features guide 4.6 Read the event log When user disarms keypad indicates the last event. the system, the In case of the user needs to read the full log file, use the keypad to go in EVENT LOG, press OK or YES on SELECT LAST EVENTS and use arrow to list the events. EVENT LOG OK or YES SELECT LAST EVENTS OK or YES 15/10/13 11:29 MODIFIED PARAMET 15/10/13 11:10 SYSTEM DISARMED Press OK or YES for more information about an event 4.7 Programmable inputs and outputs The XT control panel has 3 programmable inputs and 2 programmable outputs. Please note that we advise to connect the panels to a power supply when using programmable inputs. These functions allow the linking of Videofied security systems to auxiliary equipment such as panic buttons, pepper spray, smoke generator, hard-wired door contact, light curtain, etc. PROGRAMMABLE INPUT 1, PROGRAMMABLE INPUT 2 and PROGRAMMABLE INPUT 3 are triggered by voltage between 9V and 15V and an intensity between 1,5mA (@9V) and 3mA (@15V). If a dry contact is used to trigger the programmable inputs, the REF+output can be used to supply this dry contact. PROGRAMMABLE OUTPUT 1 and PROGRAMMABLE OUTPUT 2 can be triggered either by a panel event, by a peripheral device or by an external event such as a programmable input or a arming input. The XT control panel also offer a mapping feature. Mapping option allows the input to generate a video-clip via a MotionViewer when a programmable input is triggered and/or when an event occurs. Prog. Out. COM Prog. Output2 Prog. Output1 Ref GND Prog. Input3 Prog. Input2 Prog. Input1 Ref+
Ref GND Arming Input2 Arming Input1 Ref+
PWR AC2/DC-
PWR AC1/DC+
Prog. Out. COM Prog. Output2 Prog. Output1 Ref GND Prog. Input3 Prog. Input2 Prog. Input1 Ref+
Ref GND Arming Input2 Arming Input1 Ref+
PWR AC2/DC-
PWR AC1/DC+
For further information about the programmable inputs and outputs, please consult the following application notes available on our support website:
240-XV-XT - PROG INPUTS - APP NOTE 240-XV-XT - PROG OUTPUTS - APP NOTE 20 www.videofied.comINSTALL MANUAL 4. XT features guide 4.8 Golden rules 1 Area 1 is always delayed.When you register a keypad or a badge reader into an area, that area will automatically be delayed. 2 Never position a panel next to a high voltage electrical cabinet . 3 Press CLR to erase a typing mistake. 10 To switch between UPPER and lower case, use the M/m key from the CMA keypad or hold a digit key (0 to 9) for XMA/XMB. 11 Internal components are fragile, be careful opening or closing the panel. 4 Never register the same device twice (delete from the system first). 5 Registration of up to 25 devices (including the keypad). 12 LCD screen goes dark after 30 seconds of inactivity, press an arrow or numeric key to light it up. 6 Respect indoor infrared devices installation height (2m10 to 2m30). 13 Use only batteries provided by Videofied (siren : Alkaline 7 Outdoor cameras have to be installed at 2m60 to 3 meters height. Those devices needs to to protect an access and not a zone. 8 Do not fix the keypad at the beginning of the installation as it will need to be portable during programming. 9 Always clean the lens of the cameras after the installation
(Use a clean, dry cloth, taking care not to exert pressure on the lens). batteries). 14 Infrared detectors should never be installed in stairs or close to stairs (false alarm risks). 15 A colon display [:] means that the parameter can be changed. 21 www.videofied.comINSTALL MANUAL 5. Transmitted Events List The XT panel can be configured to enable or disable the transmission of events like alarms or defaults. The installer can modify the default sending settings for those events, although it will end the EN50131 standard compliance. These are the default transmitted events :
The following events are not sent by default :
DEVICE (intrusions) ALERT (Panic Buttons) PANEL LOW BATT. TAMPER DEVICE LOW BATT. PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST. ETHERNET CABLE AC POWER LOSS (AC Power supply) PANEL RESET PHONELINE FAULT RADIO JAMMING SUPERVISION 5 WRONG CODES ALARM CANCEL ARM/DISARM (On/Off) ZONE BYPASS (bypass function enabling/dsiabling) SWINGER SHUTDOWN There is 3 different transmission states :
ALARM : event transmitted upon occurrence ALARM/END : event is transmitted on occurrence and on event restoral NOT TRANSMITTED : event is not transmitted, however it will appear on the keypad. Example :
If the monitoring station system is set to receive arms and disarms, the ARM / DISARM parameter must be changed from NOT TRANSMITTED to ALARM / END. How to modify the transmission state At initial programming, right after the PERIODIC TEST CALL step:
CODE/STATE MODIFICATION Press OK or YES to access EVENT TRANS. MODIFICATION menu. After initial programming, using a remote keypad :
Use the arrows to access :
CONFIGURATION (level 4) > CONFIGURATION MONITOR. STATION > MONITORING PARAMETERS > EVENT TRANS. MODIFICATION Then use the arrows to determine the event to modify. Press OK or YES to edit. 22 www.videofied.comINSTALL MANUAL 6. 2G3G Error Codes IMPORTANT: The PIN of the SIM card has to be deactivated or 00000. The following is a list of error codes that can appear after the 2G3G test. 2G3G LEVEL :
ERROR XXX In case of 2G3G (GPRS or LTE) errors during initial programming, we strongly suggest to continue with the installation and perform the 2G3G
(GPRS or ) level test again once achieved. Codes 03 ou 04LP 003 010 011 012 013 014 015 Errors No network coverage or no SIM card inserted SIM card not detected/not inserted SIM not inserted PIN code necessary
-> PIN code must be deactivated PUK code necessary, SIM card blocked Default SIM card SIM card busy Error on SIM 030, 043, 057, 102, 132, ... No network coverage Typographical error in the APN Code, username, password SIM card not activated This error checklist is provided for information purposes only. This is not a comprehensive list, but it is representative of most cases. Some events or codes are subject to change by SIM card operators. However, the GPRS level test errors results in the majority of cases have the following causes :
SIM Card activation Delay:
Some operators require an additional delay up to 48 hours to activate automatic data transmission. Please check with your operator prior to installation. APN CODE, USERNAME and PASSWORD :
The GPRS or LTE (2G3G) settings are supplied by the operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator. Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! (It makes a difference between UPPER and lower case letters) . To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key (0-9) for XMA/XMB. Insufficient GPRS Network:
When the panel is unable to find any signal, proceed to GPRS/LTE level test in another location on site. You can also find the network state or condition of use by directly contacting your local operator. 23 www.videofied.comINSTALL MANUAL 7. Technical Specifications and Security Notes I N S T A L L M A N U A L FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
>
>
> Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
> Consult the dealer or an experienced radio/TV technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Cet quipement est conforme aux limites dexposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utislis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
1 2 This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
1 2 Lappareil ne doit pas produire de brouillage, et Lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This symbol on the product or on its packaging indicates that this product should not be treated as household waste. It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health. The recycling of materials will help to conserve natural resources. For more information about recycling of this product, please contact your local municipality, your waste disposal service or the company that installed the product. The declaration of conformity is available by flashing this QR code www.videofied.com 24 7. Technical Specifications and Security Notes Security notes / (FR) Notes de scurit / (DE) Hinweise zur Sicherheit English Remove battery before any maintenance !
WARNING, there is a risk of explosion if a battery is replaced by an incorrect type!
Observe polarity when setting up the batteries!
Do not throw used batteries! Bring them to your installer or a collection point. Franais Retirez les piles avant toute opration de maintenance !
Attention ! Il y a un risque d'explosion si l'une des piles utilises est remplace par une pile de type incorrect !
Respectez la polarit lors de la mise en place des piles !
Ne jetez pas les piles usages ! Ramenez-les votre installateur ou un point de collecte spcialis. Deutsch Batterien vor jeglichen Wartungsarbeiten entfernen!
Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Typs ersetzt wird!
Achten Sie beim Einsetzen der Batterien auf die Polung!
Entsorgen Sie Batterien nicht im normalen Haushaltsmll! Bringen Sie Ihre verbrauchten Batterien zu den ffentlichen Sammelstellen. Electrical data Power requirements (option 1) Power supply type B Backup Low voltage limit 9-12VDC / 1,2A 5,15V 6V with 4 x 1,5 V D Alkaline batteries /LR20 4,2V 1 year 450A 1,2A Low battery limit Battery life (average) Average current consumption (over 1h) Max current GPRS Transmission Communicator Communicator type Security Protocol IP Stack Video transmission GPRS antenna External GPRS antenna By Frontel protocol to central monitoring station Integrated Yes via MMCX connector GPRS Frontel TCP/IP Power requirements (option 2) Power supply type C 14,4V with 4x 3,6V LSH20 lithium batteries 12V 4 years Low battery limit Battery life (average) Video Video format Video size Video length MPEG Depending on camera type 10 seconds RF S2View Technology Radio type Operating frequency Transmission security Radio jam detection Supervision Antenna External radio antenna Tamper detection Tamper Programmable wired inputs Number Dry contact Input voltage Programmable wired outputs Number Max switching voltage Max switching current Max switching power Bidirectional RF 868/915/920 MHz AES algorithm encryption Yes Yes Integrated Yes via MMCX connector Miscellaneous Programming Remote Devices per system Access Badges/codes Special arming mode Number of Areas History / Event log With remote Keypad 25 maximum 20 maximum 4 4 4,000 events stored on flash memory Wall and cover tamper detection 3 Yes 12 VDC (15VDC max) 2 24VDC /30VAC 1A 30 W Box Physical and Environmental Data Operating temperature Maximum relative humidity Material Dimensions Weight
-10/+40C 75%, non-condensing ABSULV0 225 mm x 180 mm x 55mm (LxWxD) 520gr (without batteries) / 1600gr (with batteries) Installation/Mounting Control Panel/Base Two screws secures control panel cover to base; Three screws secure control panel base to the wall Approvals EN50131-1: 2007 - Grade 2 Class II
&
EN50131-3:2009 - Grade 2 EN50131-4:2009 Grade 2
&
EN50131-5-3:2005 - Grade 2 EN50131-6:2008 Grade 2 Type B &
NF C 48-212:2004 NF EN50130-4:1995; A1:1998; A2:2003 NF EN50130-5: 1998 Class II RTC 50131-3:2009 RTC 50131-4:2009 RTC 50131-6:2008 25 North American Headquarters1375 Willow Lake Blvd, Suite 103Vadnais Heights, MN 55110USAE-Mail : usasales@rsivideotech.comEMEA SALES23, avenue du Gnral Leclerc92340 BOURG-LA-REINEFRANCEE-Mail : emeasales@rsivideotech.comwww.videofied.comINSTALL MANUAL