PIR ITR601 P R O D U C T I N S T A L L A T I O N S H E E T Made by RSI VIDEO TECHNOLOGIES 2223-ITRIS March 2012 Product Summary Installation Guidelines The PIR Model ITR601 is a wireless, indoor motion detector designed for use with Videofied security systems. The detector includes the following features:
> Lithium battery for long life.
> Standard coverage lens (26ft./8 m distance).
> Dual tamper function provides detection for both wall and cover tamper.
> Transmits check-in/status signal every 8 minutes. For easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting. Install the detector and other system devices in the order of the following steps:
> Programming/RF Testing - program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel.
> Mounting - mount detector at the tested location. Programming/RF Testing The following provides summarized steps for device programming and testing. For complete details, refer to the control panel installation manual. 1 Loosen bottom screw, separate base from detector and install battery. 2 Re-attach base to secure tamper switch. 3 Put control panel into programming
/configuration mode. 4 Using a programmed alphanumeric keypad, proceed through menus until the display shows RECORDING DEVICES. 5 Press Yes. The display shows PRESS PROGRAM BUTTON OF DEVICE. 6 Press and release program button on detector using a paper clip end. The detector LED flashes. Wait for keypad display to show DETECTOR
(1 - 24) RECORDED. 7 Press Yes. The display shows RADIO RANGE TEST? Press Yes again. The detector LED starts flashing and keypad display shows TEST IN PROGRESS. Screw 8 Take detector to its intended mounting location and make sure LED flashes continuously, indicating good communication with control panel. 9 Press Yes to end radio range test, then press Esc/No. 10 The display shows AREA ASSIGNMENT AREA:
1. Press either arrow button repeatedly until desired AREA number appears, then press Yes. 11 The display shows NAME + LOCATION. Enter appropriate device name/location (up to 16 characters), then press Yes. The display shows the device number and name for your verification. 12 Press Yes. The display shows VERIFY DETECTION?
Press Yes again and verify detector operation. For example, wave your hand in front of detector to activate its LED indicating detection. 13 Press Yes to end detection verification. 14 The display shows ADD A NEW DEVICE?
Repeat steps 1 - 13 for remaining detectors. Program Button 15 When finished programming, put the control panel in operating mode. www.videofied.com PIR ITR601 I N S T A L L A T I O N D A T A S H E E T WARNING : Do not cover the Fresnel lens !
Mounting
> Use proper tools and hardware.
> Mount indoors in a temperature-controlled environment.
> Mount camera 2.1 to 2.3 (6.9 to 7.5 ft.) from the floor.
> Mount the detector on an outside wall, aimed at the area to be protected.
> Do not aim detector at windows, especially those that let in direct sunlight, or at heat sources such as lamps, fireplaces, radiators, and heating vents.
> Do not aim detector at moving objects such as curtains, fans, or animals in cages. 1 Separate base from detector. Flat Wall Mounting 2 Hold detector base against mounting surface and mark the two appropriate mounting holes. 3 Drill pilot holes and install anchors where needed. 4 Mount detector base to surface using appropriate screws 5 Install battery into detector, observing correct polarity. Corner Mounting Holes 6 Place unit on the mounting surface so mounting holes line up with pilot holes/anchors and secure the device with the appropriate screws. 7 Attach detector to base and secure with screw. www.videofied.com PIR ITR601 I N S T A L L A T I O N D A T A S H E E T Electrical Data Panel Compatibility Power requirements Nominal Voltage Low battery limit Physical Data XL, Visio, XT, XTIP Material One 3.6 V Lithium battery 3.6v 2.7v Dimensions Weight Battery type SAFT AA Lithium, LS14500 ABSULV0
(LxWxD): 2.95in x 2.16in x 2.16in
(75 mm x 55 mm x 55 mm) 3 oz./82 g (without battery) Battery life (estimated) Current Consumption Standby (1h average) Max RF technology Radio type Up to 4 years Installation/Mounting 35 uA 70mA Camera/Base One screw secures camera to base;
two screws secure camera base to mounting surface, flat or corner mount. S2View Mounting Height 6.9-7.5 Feet (2.1-2.3 meters) Spread Spectrum Bidirectional RF Operating frequency 915 MHz (US) Transmission security AES algorithm encryption Supervision Antenna Panel polls devices every 8 minutes Integrated Tamper detection Wall and cover tampered Video sequence in intrusion 5 frames/s for 10 seconds Motion detector technology Passive infrared DSP Motion detector type Motion Lens Motion Detection angle Motion Detection distance Motion Detection pattern Dual element Fresnel 90 Up to 26 ft / 8m 24 facets Operating temperature 14 - 104 F (-10 - 40 C) Maximum relative humidity 75%, non-condensing Certifications FCC Part 15C www.videofied.com PIR ITR601 P R O D U C T I N S T A L L A T I O N S H E E T FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. EMEA SALES 23, avenue du Gnral Leclerc 92340 BOURG-LA-REINE FRANCE Hotline: +33 (0)820 846 620 Fax: +33 (0)1 82 69 80 10 USA SALES 4455 White Bear Parkway, Suite 700 White Bear Lake, MN 55110 USA Hotline: +1 877 206 5800 Fax: +1 651 762 4693 www.videofied.com 2011 RSI VIDEO TECHNOLOGIES. VIDEOFIED is a Registered Trademark of RSI VIDEO TECHNOLOGIES. S2View is a registered trademark of RSI VIDEO TECHNOLOGIES. Specifications subject to change without notice.