Indoor Siren SE601 P R O D U C T I N S T A L L A T I O N S H E E T Made by RSI VIDEO TECHNOLOGIES 2205 - SEIS March 2012 Product Summary The Interior Siren SE601 is a wireless siren designed for use with Videofied security systems. The siren includes the following features:
> Totally wireless, battery operated.
> Dual tamper function provides detection for both wall and cover tamper.
> Transmits check-in/status signal every 8 minutes. Programming/RF Testing The following provides summarized steps for device programming and testing. For complete details, refer to the control panel installation manual. 1 Remove bottom screws, separate cover from siren and install batteries. 2 Put control panel into programming/
configuration mode. 3 Using a programmed alphanumeric keypad, proceed through menus until the display shows ADD A NEW DEVICE. 4 Press Yes. The display shows PRESS PROGRAM BUTTON OF DEVICE. 5 Press and release program button on siren using a paper clip end. The siren LED flashes. Wait for keypad display to show SIREN (1 - 25) RECORDED. Screws Program Button Installation Guidelines For easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting system devices. Install the siren and other system devices in the order of the following steps:
> Programming/RF Testing - program siren and all other devices into the control panel and test RF communication from each intended device location to the control panel.
> Mounting - mount siren at the tested location. 6 Press Yes. The display shows RADIO RANGE TEST?
Press Yes again. The siren LED starts flashing and keypad display shows TEST IN PROGRESS. 7 Take siren to its intended mounting location and make sure LED flashes continuously, indicating good communication with control panel. 8 Press Yes to end radio range test, then press Esc/No. 9 The display shows RECORDING A NEW DEVICE?
Repeat steps 4 - 8 for remaining sirens. 10 When finished, exit from configuration mode. www.videofied.com Indoor Siren SE601 I N S T A L L A T I O N D A T A S H E E T Mounting
> Use proper tools and hardware.
> Mount where siren can be heard by occupants.
> Mount out-of-reach of intruders to help prevent disabling of unit. 1 Remove batteries. 2 Hold unit up against mounting surface and mark the three mounting holes. 3 Drill pilot holes and install anchors where needed. Mounting Holes 4 Place unit on mounting surface so mounting holes line up with pilot holes/anchors and secure unit with appropriate screws. 5 Install batteries, observing correct polarity. 6 Attach front cover. Electrical Data Panel Compatibility Power requirements Nominal Voltage Low Battery Limit Physical Data XL, Visio, XT, XTIP Material ABSULV0 Four 1.5 V Alkaline Batteries 6V 4.2V Dimensions (LxWxD) 280 mm x 158 mm x 57 mm 11 in. x 6-1/4 in. x 2-1/4 in. Weight 740 g/26 oz.(without batteries) Battery type Energizer Alkaline LR20, D size Battery life RF technology Radio type Up to 4 years Installation/Mounting Spread Spectrum Bidirectional S2View Siren/Base Two screws secure siren to base; three screws secure siren base to mounting surface. Operating frequency 915 MHz Transmission security AES encryption algorithm Supervision Antenna Tamper detection Speaker impedance Output level Output duration Polled signal every 8 minutes Integrated Wall and cover tampered 4 ohms 110 dB @ 1 meter Configured in Control Panel Built-in sounder Emits entry/exit delay beeps, alarms Operating temperature
-10/+40C (14/104F) Maximum relative humidity 70%, non-condensing Approvals FCC Part 15C www.videofied.com Indoor Siren SE601 P R O D U C T I N S T A L L A T I O N S H E E T FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. EMEA SALES 23, avenue du Gnral Leclerc 92340 BOURG-LA-REINE FRANCE Hotline: +33 (0)820 846 620 Fax: +33 (0)1 82 69 80 10 USA SALES 4455 White Bear Parkway, Suite 700 White Bear Lake, MN 55110 USA Hotline: +1 877 206 5800 Fax: +1 651 762 4693 www.videofied.com 2011 RSI VIDEO TECHNOLOGIES. VIDEOFIED is a Registered Trademark of RSI VIDEO TECHNOLOGIES. S2View is a registered trademark of RSI VIDEO TECHNOLOGIES. Specifications subject to change without notice.