all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 2.28 MiB | May 05 2014 | |||
1 | Cover Letter(s) | May 05 2014 | ||||||
1 | Cover Letter(s) | May 05 2014 | ||||||
1 | ID Label/Location Info | May 05 2014 | ||||||
1 | Test Report | May 05 2014 | ||||||
1 | External Photos | May 05 2014 | ||||||
1 | Internal Photos | May 05 2014 | ||||||
1 | Test Report | May 05 2014 | ||||||
1 | Test Setup Photos | May 05 2014 |
1 | Users Manual | Users Manual | 2.28 MiB | May 05 2014 |
Document #2029-XTIPIN COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT-IP620
*A Videofied CMA/XMA/WMB Alphanumeric Keypad or Frontel TMT2 is required for programming and maintenance*
CMA XMA WMB Setup and Programming manual for XT-IP620 series Page 3 4 5 6-15 16 17-18 18 19 20 21 22 23 24 25 26-28 29-30 31-33 31 32 32 32 33 33 Table of Contents FCC Installation Guidelines Introduction Initial Programming Device Installation Entering Badges and Access Codes Choosing Siren Options Disabling Monitoring Ethernet Parameters and Testing Testing Device RF Level XTIP Power Chart Arming Input Wiring Diagram Testing to Central Station Mounting Control Panel Troubleshooting After Initial Programming Flow Chart Addendum Battery Specifications Finding Manufacture Week/Year Event Log Ethernet Codes Additional System Quick Codes Replacing Device and Control Panel batteries Checking Control Panel Firmware 2012/1/9 Ed 1.1 2 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series Regulatory Information for USA and Canada FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected. Consult the dealer or an experienced radio/TV technician for help. Radiofrequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la Partie 15 des rglementations de la FCC et avec la norme RSS-210 de lIndustrie Canadienne. Son fonctionnement est soumis aux deux conditions suivantes :
1 Cet appareil ne doit pas causer dinterfrences nuisibles et 2 Cet appareil doit accepter toute interfrence reue, y compris les interfrences pouvant entraner un fonctionnement indsirable. 3 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series Basic Setup Guidelines for Installation and Programming a. Pre-Setup
(Pages 6-15) Deploying the System on Site System Programming and Setup STATUS test to make sure you are receiving an IP. (Page 20) test on the first device, then mount it. If not, you will need to move the device to get optimal signal.*
(Page 21) 1) Obtain the account number and IP/Domain information from the Central Station. 1) Setup and program the system in the office or in your vehicle. DO NOT MOUNT THE DEVICES. 2) Add user codes and or badges after initial programming. (Pages 17-18) 3) Disable monitoring so that signals are not sent until you are ready to send them. (Page 19) 1) Place the panel where you want to mount it and run the Ethernet cable. In Maintenance run the ETH. 2) Deploying Devices: Use your keypad to run the RF test for each device. If you get a 9/9 for your RF 3) Re-enable monitoring before you send signals (Page 19) 4) Once you have everything mounted, arm the system and trip one MotionViewer at a time. Make sure you stand in front of each MotionViewer for 10 seconds so the central station has some video to look at. (Page 24) 5) After you have sent signals to central station, call to verify. The following pages will go through each one of these steps and, if you have any issues please consult the troubleshooting section Pages 26-28. If you still cannot resolve the issue, please feel free to call technical support through live support chat and ticket submission at support.videofied.com. Sleeping mode and Wake-up on the CMA:
They keypad backlight will go out after 30 seconds of inactivity. When you press a button the keypad wakes up. The first touch on the pad that wakes it up will not be a registered command and will only wake up the keypad. Sleeping mode and wake-up on the XMA/WMB:
The keypad backlight will go out after 30 seconds of inactivity. The first touch on the keypad will wake up the keypad and will register as a command to the control panel. If you are currently using TMT Installer to program the system you can now take still pictures from each MotionViewer using the software. See TMT Installer Users Manual available on http://support.videofied.com 4 | P a g e Setup and Programming manual for XT-IP620 series 2012/1/9 Ed 1.1 Introduction:
Description:
The XT-IP620 control panel is a Videofied wireless, battery operated hybrid alarm system. It is designed for residential, small business and commercial security applications. The XT-
IP620 provides integrated Video Verification and features an Ethernet communication path. The XT-IP620 has programmable inputs and outputs. XT-IP620 also features mapping where an external input can be used to generate a video clip from a MotionViewer. Supervised Wireless Technology:
The XT-IP620, along with all Videofied devices, uses the patented S2View - Spread Spectrum, Videofied, Interactive, AES Encrypted Wireless technology, providing optimum signal integrity and security. The bi-directional RF communication path between all devices and the system control panel guarantees high signal reliability. Integrated antennas eliminate protruding wires or rods, which are difficult to install, unsightly to consumers and potentially troublesome if damaged. The panel supervises every device (excluding the remote key fob) to validate current open/close state, tamper condition, serial number, date of manufacture, firmware revision, and battery status. In order for an installation to be UL compliant you must follow the specifications in the table below:
Location In Manual Type Audio Audio Delays Specifications When a MotionViewer is installed on the system you may not have the siren sound for less than 60 seconds If no MotionViewer is installed on the system you may not have the siren sound for less than 240 seconds When a MotionViewer is installed on the system the Entry delay must be 45 seconds Page 30 Page 30 Page 9 5 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series SETUP MANUAL FOR XT-IP620 SERIES PANEL
*THIS SYSTEM REQUIRES A CMA/WMB/XMA or TMT2 INSTALLER SOFTWARE FOR
**TO TRANSMIT ALARMS AND VIDEO VIA ETHERNET, THE SYSTEM REQUIRES AN EXTERNAL POWER SUPPLY WITH 4 ALKALINE BATTERIES FOR BACK-UP (PP4)**
PROGRAMMING*
XT Initial Programming Open the Control Panel Using a #1 Phillips screwdriver, remove the 2 screws holding the cover on. The cover will fold off the panel like a book with the curved side acting like the binding. The same technique is used when placing the cover back onto the unit. 6 | P a g e Setup and Programming manual for XT-IP620 series 2012/1/9 Ed 1.1 Connect the RJ45 (Ethernet cable) to the panel Plug the RJ45 cable into the Ethernet jack on the control panel. The cable can be routed back through the wire channel to make sure it does not get pinched. Important:
When the panel attempts a transmission via Ethernet a red LED will flash. Obtaining WMB/XMA Keypad Special Characters Obtaining CMA Keypad Special Characters 7 | P a g e Setup and Programming manual for XT-IP620 series 2012/1/9 Ed 1.1 Power Option (PP4) 4 x E95VP Alkaline D-Cell + 12v 2amp DC Class 2 power supply (not supplied) Used for Standalone or Xtender mode where Programmable Inputs/Mapping, Programmable Outputs, Ethernet connection, or SMS will be used E95VP Specifications:
Operating Temp: 0F to 130F Output Voltage (volts) Output Current (mA) Power Supply Requirements 12 2000 Certifications Class 2 (For UL Compliance) E95VP Technical Specifications Nominal Capacity 8900 mA hours Nominal Voltage 1.5 V WARNING:
1. DO NOT USE ALKALINE BATTERIES IF INSTALLING BELOW 30 F 8 | P a g e 2012/1/9 Ed 1.1 XT-IP620 Programming Setup and Programming manual for XT-IP620 series Press and hold programming button () for 10sec until the Reset the XTIP Panel:
Indicator LED blinks twice Press and instantly release the programming button (). The indicator LED will blink once. The panel is now in Learn Mode for the CMA/XMA/WMB keypad. Insert all three batteries into the CMA/XMA/WMB and press both the ESC/NO and CLR keys at the same time and release. The indicator LED on the keypad will blink rapidly. Other languages are available by scrolling with arrows. ITALIANO, NEDERLANDS, DEUTSCH, CASTELLANO, SVENSKA, PORTUGUES, FRANCAIS Press YES/OK for the selected one.
*NOTE: If you are having issues pairing the keypad to the panel, please refer to the troubleshooting section. Programming Device/Keypad or
<======XX======>
RSI (c)20##
www.RsiAlarm.com CLR & ESC/NO KEYPAD 1 RECORDED YES/OK
<- LANGUAGE : ->
ENGLISH (US/AUS) or for language selection YES/OK to apply
*NOTE: Once a language is chosen it cannot be changed in programming. 9 | P a g e The Radio Range test must be run during device recording to ensure proper pairing with the control panel. This test the number of successful pings between the device and the control panel. The keypad will display a real time RF level for the device that is being tested. This test will run until stopped and should be run for at least 30 seconds to receive accurate results. The RF level must be 9/9 for reliable transmission. 2012/1/9 Ed 1.1 Wait while the screen changes From here until the end of initial programming you will not be able to step back to a previous parameter. All parameters can be changed after initial programming has been completed. Use the Alphanumeric Keypad to enter the Installer Code
*This code is important to keep track of. There is no back door to the system You may name the installer code using the Alphanumeric Keypad. If you leave the name blank it will default to ACCESS 1 Wait while the screen changes Use the or to choose between Auto and manually configuring the Date and Time Auto: You will use the arrow keys to choose the UTC time zone that the panel will be installed at followed by the exact location within the time zone. Manual: Use the arrow keys to define the year/ Month/ Day/
Hour/ Minute. Setup and Programming manual for XT-IP620 series YES/OK RF TEST x/9 YES/OK RADIO RANGE TEST ?
RADIO RANGE TEST ?
ESC/NO ENTER THE INSTALLER CODE 4 TO 6 DIGITS THEN YES/OK INSTALLER CODE:
CONFIRM CODE RE-ENTER CODE CODE NAME:
ACCESS 1 ENTRY COMPLETE SETTING DATE AND TIME SETTING:
AUTO TIMEZONE:
UTC-05 INSTALLER CODE:
xxxx YES/OK CONFIRM CODE xxxx YES/OK SETTING:
MANUAL YES/OK DATE (Year) :
13/
YES/OK UTC-06:
CENTRAL (US/CAN) DATE (Month) :
13/11/
10 | P a g e 2012/1/9 Ed 1.1 YOU MUST ALWAYS CHOOSE YES/OK Use the Alphanumeric Keypad to enter in a 4-8 digit account number provided by the Central Station Other periods are available:
24 hours, 12 hours,1 hour, 7 days No Test Use arrows for the selection and press YES/OK to confirm. Use the arrow keys + YES/OK to choose the Hour and Minute the periodic test will happen. Setup and Programming manual for XT-IP620 series DATE (Day) :
13/11/05 YES/OK TIME (HOUR) :
10:00 YES/OK DATE (Minutes) :
10:53 YES/OK CONNECTED TO MONITOR.STATION?
YES/OK ACCOUNT NUMBER?
ACCOUNT NUMBER:
99865123 YES/OK PERIODIC TEST:
24 HOURS or for period selection and YES/OK to apply TEST HOUR:
00:00 YES/OK TEST MINUTE:
00:00 YES/OK 11 | P a g e CODE/STATE modification These are the default transmitted events:
Device Alert Panel Reset Panel Batteries AC Power Phoneline Fault Tamper Device Batt. Radio Jamming Supervision Periodic Test Wrong Codes Duress Code Alarm Memory Arm/Disarm Fire Medical Assist Ethernet If you would like to change the state Event Event Not Transmitted Event/Restore Event/Restore Not Transmitted Event/Restore Event/Restore Not Transmitted Event/Restore Event Not Transmitted Event Not Transmitted Not Transmitted Event/Restore Event Event/Restore press YES/OK and use the or to toggle between:
Alarm Appearance Alarm/End Appearance and Restoral Not Transmitted Not Transmitted Your IP1 address is given to you by your Central Station. Your IP1 address is given to you by your Central Station. Press YES/OK to enter into the parameter and use the Press YES/OK to enter into the parameter and use the Keypad to complete the address. Press YES/OK to Keypad to complete the address. Press YES/OK to confirm your entry and the arrow to move to the next confirm your entry and the arrow to move to the next parameter. *You will use either an IP address or a Domain parameter. *You will use either an IP address or a Domain Name but not both Name but not both
*When entering an IP address you must enter all 12 digits
*When entering an IP address you must enter all 12 digits including preceding zeros. including preceding zeros. Your Domain Name is given to you by your Central Station. Press YES/OK to enter into the parameter and use the Keypad to complete the name. Press YES/OK to confirm your entry and the arrow to move to the next parameter. *You will use either an IP address or a Domain Name but not both leave it blank if an IP has already been The Port is given to you by your Central Station. By default the panel will use 888. If you need to modify the port press the YES/OK key to enter into the parameter and the keypad to complete the port. Press YES/OK to confirm and the arrow to move to the next parameter. Continue through IP2 and TMT IP. Once you have entered all valid parameters press ESC/NO to return to the main menu then ESC/NO again to move to the next parameter. 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series CODE/STATE MODIFICATION?
YES/OK TRANS. STATE MODIFICATION YES/OK List of all events ESC/NO ESC/NO TRANS. STATE MODIFICATION SERVER ADDRESSES?
IP 1 ADDRESS ESC/NO YES/OK YES/OK IP1 ADDRESS:
xxx.xxx.xxx.xxx YES/OK DOMAIN NAME 1 YES/O PORT 1 SERVER ADDRESSES?
ESC/NO DOMAIN NAME 1:
xxxxx.xxx.xxx YES/OK YES/OK PORT 1:
xxx ESC/NO 12 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series ETHERNET PARAMETERS DHCP:
ENABLE OR DISABLE These parameters are not necessary if you choose DHCP ENABLE These parameters are the local network parameters. Its necessary to configure all these parameters if DHCP is disabled. IMPORTANT: Verify that the IP address selected is available on the Network. ENABLE ETHERNET PARAMETERS?
ESC/NO ETH. STATUS?
ETH. STATUS?
ESC/NO During this test, the panel tries to connect to the local Ethernet Network. The result of this test can be:
If the connection is successful: the local IP of the panel will be displayed (with right arrow you can display other Ethernet parameters IP Mask, primary & secondary, Gateway). ETHERNET OFF NO STATUS: the Ethernet module is switched off. Please verify that the Ethernet cable is connected and try again. CABLE OR NETWORK ABSENT: the panel doesnt detect Ethernet Cable or Network. DHCP ERROR: the panel is not able to get an IP from the DHCP. DHCP may be enabled but the network may not have a DHCP lease available. DISABLE PANEL IP IP MASK GATEWAY PRIMARY DNS SECONDARY DNS YES/OK TEST IN PROGRESS OK/YES/OK = END PANEL IP xxx.xxx.xxx.xxx 13 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series Enter the name of the logical area 1 + YES/OK. Repeat this step for areas 2, 3, 4. Refer to page 4 for more information. Press ESC/NO if you want to let default value. Note: Areas are designed to define logical separation ARMING OPTION: Your choice will depend on how you are arming the system. From the host: Will make the XT a piggyback/xtender system that arms and disarms off the latching of 9-12v on the arming inputs. Standalone: Will make the XT a solo system controlled by arming and disarming using Videofied peripheral devices. Other values are available:
2 min, 1 min, 45 sec Use the arrows for the selection and YES/OK to confirm. Other values are available:
2 min, 1 min, 45 sec, 30 sec, 15 sec Use the arrows for the selection and YES/OK to confirm. AREAS CONFIGURATION AREA NAME 1:
ARMING OPTION:
Standalone ARMING OPTION:
From the host EXIT DELAY:
45 Sec ENTRY DELAY:
15 Sec Go to Page 15 to continue with standalone programming Using the control panel in the FROM THE HOST mode will only be able to arm and disarm by latching 9-12v to one of the two inputs. Wiring diagrams available on page 26. Arming input 1 will control the arming and disarming of devices in areas 1 and 2. Where devices in area 1 are subject to the Entry Delay. Arming input 2 will control the arming and disarming of devices in areas 3 and 4. Where devices in area 3 are subject to the Entry Delay. ARMING OPTION :
From The Host YES/OK Mode Slow : Used for following the arming and disarming of the host system. This will arm each device one at a time conserving battery life. Mode Fast : Used to instant arm all devices while sacrificing battery life. Enter the value for your Entry Delay up to 255 seconds and press YES/OK. MODE:
Slow YES/OK MODE:
Fast YES
/OK YES/OK ENTRY DELAY VALUE:(0-255)
(000):
14 | P a g e 2012/1/9 Ed 1.1 By entering a value using the keypad, up to 600 seconds, the transmission of any event will be delayed that many seconds. Enter the value you would like for the Transmission Delay and press YES/OK Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input. This feature can be used as an exit delay. Enter the value you would like for the Arming Confirmation and press YES/OK Each device has a unique programming button. Please reference the Installation Sheet for the device you would like to program.
*Note: If you are having issues pairing a device to the panel, please refer to the troubleshooting section. Press YES/OK on Radio Range Test? You must allow the Radio Range test to run for at least 30 seconds (9/9) before stopping the test by pressing YES/OK. Press ESC/NO if first Radio Range Test was successful. Use the arrow keys to select the proper area. Devices that need an entry/exit delay should be set to AREA 1. Devices that must be instant trigger should be AREA 2, 3, or 4. Press YES/OK. Setup and Programming manual for XT-IP620 series TRANSMISSION DELAY Value: (0-600)
(000):
YES/OK ARMING CONFIRMATION Value: (0-240)
(0):
YES/OK RECORDING DEVICES PRESS PROGRAM BUTTON OF DEVICE YES/OK RADIO RANGE TEST?
RADIO RANGE TEST?
NAME LOCATION:
(Device Type) #
Recorded RF TEST x/9 AREA ALLOCATION:
FUNCTIONAL DEVICE TEST?
ENTERING A NEW DEVICE?
YES/OK or ESC/NO Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is off. CLOSE THE PANEL OPERATION COMPLETED?
YES/OK 15 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series Device Installation DCV651 Outdoor MotionViewer / BR651 Outdoor Badge Reader Place batteries in Device. Wait for LED to turn on. Press and release the programming button. DCV601 Indoor MotionViewer / ITR601 Indoor Blind PIR Place batteries in device. Wait for LED to turn on behind PIR lens. Press and release the programming button. CT601 Door/Window Contact DCV601 ITR601 Place battery into the door/window contact. Wait for LED to turn on. Press and release the programming button. RC601 Remote Control Fob Press and hold the ON and OFF keys at the same time for 5 counts of Mississippi and release. SE651/601 Indoor and Outdoor Sirens Place all batteries into the siren. Wait for the LED to turn on right above the programming button. Press and release the programming button. 16 | P a g e 2012/1/9 Ed 1.1 Entering a Badge or Access Code for Arming/Disarming Setup and Programming manual for XT-IP620 series After Initial programming has been completed, you are not able to arm and disarm the system until you enter a user code or badge (the installer code cannot arm and disarm the system). Codes can be 4-6 digits and the 4th digit must be 2 values higher or lower than any other code on the system:
Example: User code 1234, next code cannot be 1235, 1236, 1233, or 1232 These are reserved for Silent Duress and Audible Duress. The XT system can accept up to 19 Badges or Access codes in any combination. You must first change the access level to 4. Right Arrow to Access Level and press YES/OK. Use the arrow keys to move to Level 4 and press YES/OK. When prompted with Badge Or Code enter the installer code followed by YES/OK. 10/12/27 10:53 DISARMED LVL:1 ACCESS LEVEL:
4 YES/OK BADGE OR CODE
Press the arrow to move to BADGES ACCESS CODES. Enter a 4-6 digit user code or present a badge to the reader for 2 seconds. Confirm the code by re-entering. BADGES ACCESS CODES ENTER A BADGE/CODE YES/OK YES/OK BADGE OR CODE:
YES/OK CONFIRM THE CODE:
YES/OK Badge Presented NAME OF BADGE:
YES/OK Use the keypad to name the badge or code or leave it blank for the default name: ACCESS #. CODE NAME:
YES/OK ENTRY COMPLETE If you are entering any additional codes press YES/OK. If you have completed entering Badges and Codes press and hold ESC/NO for 5 seconds to return to the main manu. ENTER A BADGE/CODE 000000 Reserved codes Reserved codes From 9998 to 9999 From 99998 to 99999 From 999898 to 999999 From 314157 to 314159 Reserved codes All codes +1 All codes +2 All codes -1 All codes 2 A total of 186 codes are forbidden 17 | P a g e 2012/1/9 Ed 1.1 Access level LVL1 LVL2 LVL3 Setup and Programming manual for XT-IP620 series Definition & rights Stand by level Restricted USER level where it is only possible to arm/disarm the system. USER level where it is possible to arm/disarm the system, check the event log, test the devices. Modifications of the setting are not possible at this level. User LVL3 can create LVL3 or LVL2 access codes. LVL4 INSTALLER level where it is possible to modify the setup of the panel. The approval of a LVL3 or LVL2 is required to modify the level for LVL4. Installer LVL4 can create the first LVL3 access code only. Configuration of Special Arming Modes:
To configure or modify a special arming mode, with the direction arrow go to the menu:
CONFIGURATION (LEVEL 4) + [YES/OK] ALARM MODES PROGRAMMABLE + [YES/OK]
FULLY ARMED, SP1 and SP2 (use direction arrows to select the arming mode you want to modify + [YES/OK]). For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm. Areas: 1 2 3 4 press the corresponding number to change that areas arming option States: A A A A state for the respective area. Press the [YES/OK] key after this configuration step. The system will then display what siren mode will be in effect for this special profile. Select the siren mode using the direction arrows then press [YES/OK]. A D P E Perimeter Devices Only
(devices must be programmed) External Devices Only
(devices must be programmed) Armed Disarmed Siren Delay beeps Silent Without Siren Beeps on the keypad only Immediate triggering of all sirens Entry/Exit delay beeps, then triggering of the sirens No Sirens, No Beeps 18 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series How to Disable/Enable Monitoring Disabling monitoring can be a useful tool in many situations. Before mounting devices and moving the panel to find a good communication with devices, disabling monitoring will ensure that you will have access to programming and that unnecessary signals are not sent to the monitoring station. When performing maintenance on the system disabling monitoring until the issue has been resolved will ensure that you will have access to programming throughout your troubleshooting. Press the arrow to move to ACCESS LVL. 10/12/27 10:53 DISARMED LVL:1 Use your arrow keys to change the level to 4 ACCESS LVL: 4 Enter the installer code for the system. If a level 3 code is entered in the system you will be required to authenticate with that code as well. BADGE OR CODE
ACCESS LEVEL 1 YES/OK YES/OK Press the to move to CONFIGURATION Use the to move to CONFIGURATION MONITOR. STATION Press YES/OK on MONITORING PARAMETERS Press YES/OK on MONITORING ENABLED and use the to change the value to DISABLED and press YES/OK to lock it in. Press and hold ESC/NO for 5 seconds to return to the main menu. CONFIGURATION YES/OK GENERAL PARAMETERS CONFIGURATION MONITOR. STATION YES/OK MONITORING PARAMETERS MONITORING ENABLED YES/OK MONITORING:
DISABLED YES/OK 19 | P a g e Setup and Programming manual for XT-IP620 series 2012/1/9 Ed 1.1 ETHERNET Parameters:
nging Siren Options To configure or modify Ethernet Parameters, go to:
CONFIGURATION (level 4) + [YES/OK] >> GENERAL PARAMETERS + [YES/OK] >> ETHERNET +
After initial programming has been completed any sounder on the system will be enabled by default,
[YES/OK]
this includes the sounder on the Keypad and Badge Reader. While there is no way to disable the sounding of the exit delay you are able to disable the intrusion sound. IP Parameters:
1. DHCP Enable IP address is assigned by the DHCP service on the network. 2. DHCP Disable IP address must be defined in Ethernet parameters. IP address will NOT be automatically obtained from DHCP service on the network. Constant Ethernet:
1. Auto Mode - We recommend this mode. If main powered, the panel will be connected constantly to the local Network. In case of an alarm, the alarm will be sent in few seconds to the monitoring station. When the main power is cut, the Ethernet module will switch off after a delay (DELAY BEFORE OFF 30 by default) in order to save battery life. In case of an alarm, the panel will at first connect to the local Network. It adds few seconds to the total process of sending an alarm. 2. ON Mode - The panel will be connected constantly to the local Network. This option will impact back-up battery life. 3. OFF Mode - For each transmission of alarm and video, the panel will connect to the local PING REPLY: Enables ping response Time Out Server: In case of disconnection to the local Network, the panel will try after that time to re-connect. Max Seg. Size: Size of packet sent Maintenance request - Ethernet transmission Action Displays local IP address assigned to the control panel:
If the DHCP mode is deactivated : the static local IP of the panel will be displayed
(defined in the ETHERNET menu 7) If the DHCP is activated:
If the panel is not in transmission then 0.0.0.0 will be displayed If the panel is in transmission (the RJ45 led will be flashing) then the dynamic IP of the panel will be displayed. How to test to the dispatch center 999991 Testing to the dispatch is done twice during installation. Once while you are programming the system and then again once the installation has been completely finished. Although both will use the same steps the initial test will be just confirmation using one device to verify the programming. Sends a test alarm to IP1 Address (Primary alarm receiver) This is a quick way to check for connectivity to the monitoring center. If there is a transmission problem the panel will terminate communication faster than in an actual alarm. The system will automatically attempt connection to IP2 Address (Backup alarm receiver) in the event that IP1 is unavailable. Displays external power supply status 999997 How to Disable Monitoring Disabling monitoring can be a useful tool in many situations. Before mounting devices and moving the panel to find a good 2G3G level, disabling monitoring will ensure that you will have access to programming and that unnecessary signals are not sent to the monitoring station. When performing maintenance on the system disabling monitoring until the issue has been resolved will ensure that you will have access to programming throughout your troubleshooting. 20 | P a g e Network. Codes 999996 999995 Setup and Programming manual for XT-IP620 series 2012/1/9 Ed 1.1 How to test RF for deployment of devices Running the RF test during the mounting of devices is key to a successful Videofied installation. This test will ensure that all devices have adequate communication with the control panel. All Videofied devices are bi-directional which allows the system to ping the device and expect a response. The number of successful responses out of 9 will be displayed on the keypad for the device you are running the test for. This is also a relative range that will change in real time as you walk further away from the control panel and back closer. When in Access Level 3 or higher press the arrow to move to MAINTENANCE Press the arrow to move to DEVICE LOCATING Press YES/OK on DEVICE LOCATING to get to the list of devices. Use the arrow keys to find the device you would like to run the test for. This test will run as long as you need it to. Pressing the YES/OK, ESC/NO, or CLR buttons will end the test. This test will show the results on the display of the keypad relative to the number of successful pings to the panel. It is required to run the test for at least 30 seconds at the mounting location for accurate results and to have a 9/9 for reliable transmission of alarms and video. Press YES/OK when you are finished with the test. 10/12/27 10:53 DISARMED LVL:3 MAINTENANCE DEVICE LOCATING YES/OK YES/OK
(DEVICE NAME) RF TEST 0/9 YES/OK YES/OK Press and hold ESC/NO for 5 seconds to return to the main menu.
(DEVICE NAME) Once all devices are checking in at 9/9, you are ready to test the full system to your central station. After arming and tripping each device call the central station and verify alarm and video of each device with dispatch. Now you are ready to show the customer how to use the system. NOTE: To insure proper operation of the system you must get 9/9 with each device before mounting. 21 | P a g e 2012/1/9 Ed 1.1 XT-IP620 Power Chart Setup and Programming manual for XT-IP620 series 22 | P a g e 2012/1/9 Ed 1.1 Arming Input Wiring Diagram Setup and Programming manual for XT-IP620 series When in the Arm From Host mode the Videofied system will only arm and disarm when 9-12v is supplied and sustained. When both arming inputs are supplied voltage at the same time the Videofied Keypad display will show SYSTEM ARMED. When only one arming input is supplied voltage the Videofied Keypad display will show PART LVL #
Arming Input 1 will arm/disarm Areas 1 & 2 Arming Input 2 will arm/disarm Areas 3 & 4 23 | P a g e 2012/1/9 Ed 1.1 How to test to the dispatch center Setup and Programming manual for XT-IP620 series Testing to the dispatch is done twice during installation. Once while you are programming the system and then again once the installation has been completely finished. Although both will use the same steps the initial test will be just confirmation using one device to verify the programming. 10/12/27 10:53 DISARMED LVL:1 10/12/27 10:53
ARMING THE SYSTEM YES/OK SYSTEM ARMED INTRUSION DETECTED
(DEVICE NAME)
(AREA) SYSTEM ARMED
YES/OK YES/OK YES/OK 10/12/27 10:53 DISARMED LVL:1 Enter a User code and press YES/OK or present a badge to the reader. The system will sound the exit delay through the keypad and badge reader. Once the delay has expired and the keypad says SYSTEM ARMED, put motion in front of a MotionViewer. If the MotionViewer is in area 1 you will need to wait for the entry delay to expire before disarming the system. Once the system has gone into alarm enter a User Code followed by YES/OK or present a badge to the reader to disarm. The display will tell you that there has been an intrusion since the last time the system was armed. Press YES/OK to continue After pressing YES/OK the keypad will tell you which device has been triggered. Press YES/OK to continue. The system will go back to the main menu automatically but will not allow you to move around in programming until the system has disconnected from the central station. To verify that the system has transmitted you must contact the Dispatch Center and have the account information ready Note: Send 1 MotionViewer in at a time and verify with Central Station that they are getting Alarm and Video before tripping another MotionViewer. This will save time with the Central Station. 24 | P a g e
. How to Mount the Control Panel?
Fix the back casing on the wall with 3 screws () 2012/1/9 Ed 1.1 How to mount the XT-IP620 Setup and Programming manual for XT-IP620 series 25 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series Troubleshooting Monitoring Station is not getting ANY video but is getting signals:
Good communication between the MotionViewers and the Control Panel is key to getting successful video to the monitoring station. During mounting of any device on your Videofied system you must run the Radio Range/Device Locating test to ensure that the mounting location is with-in range of the Control Panel. Concrete, Metal and earth are some of the largest RF inhibitors and should be taken into account when choosing mounting locations. When running the Radio Range/Device Locating test you should have the site as close to the same as it would be when the site is closed/no one is there, i.e. close garage doors/service doors, etc. Device locating steps can be found on Page 17. Devices are not sending Video clips Check Maintenance/
Display Faulty Devices NO There are no faulty devices Run Maintenance/
Device Locating Device Locating will test the RF signal strength between the device and the Control Panel. For reliable transmission this result must be a 9/
9. This is the number of successful pings between the device and the Control Panel so a loss of just 1 packet could cause failure to transmit video. YES/OK There are faulty devices MotionViewers come up with Radio Problem. This means that the MotionViewers are currently not talking with the Control Panel. Bring the devices back to the Control Panel and hit the programming button to force them to sync back with the panel. Important Note: Videofied will only automatically download the first MotionViewer video that is taken and only if this is the primary event or reason for the panel connecting with the monitoring station. If the account is on test you will only ever get the first video downloaded. If you are only getting the events at the station and all tests above pass more than likely you are sending a preceding event (like an arming signal or door contact) which will cause the video to not auto download because the video is not the primary event. 26 | P a g e 2012/1/9 Ed 1.1 Monitoring Station is not getting any signals:
Setup and Programming manual for XT-IP620 series Communication between the Control Panel and the Monitoring Station is over an Ethernet Connection. Go into Maintenance and run the ETH STATUS to see if you receive back an IP Address or error. If you receive an IP Address back you will want to contact and consult the network admin to make sure the outbound port is not being blocked (Port 1 programmed in the panel). Panel is staying CONNECTED WITH MONITOR STATION While the Control Panel is attempting or is connected with the Monitoring Station you will see this message when you attempt to move around on the keypad. If the system is not successful in connecting with the station it will retry the connection multiple times, locking you out of programming until it is done trying. This normally can take anywhere between 15-20 minutes. If you want to force the panel to disconnect you must o 1. Remove the batteries from the control panel o 2. Secure the cover tamper of the panel o 3. Re-insert the batteries into the control panel and sync the keypad back by pressing o 4. Access the Configuration menu by changing you access level to 4 and go to o 5. In Monitoring Parameters Disable monitoring until the connection issue is resolved. the CLR and ESC/NO buttons at the same time. Configuration Monitor Station. 27 | P a g e 2012/1/9 Ed 1.1 Unable to record device or getting Pairing Failure error Setup and Programming manual for XT-IP620 series This usually occurs when the device still has a pairing key from a previous system or setup. To perform a pairing key override:
o 1. Remove all batteries from the device. o 2. Make sure your system is ready to record devices:
o A. If learning in the keypad, press the panels programming button. DO NOT o B. If learning in additional devices, make sure the keypad reads Press HOLD THE PANELS PROGRAMMING BUTTON Programming Button Of Device o 3. Insert a single battery into the device. o 4. Wait 1 second for device to power up. o 5. Press programming button of device (for keypads press CLR & ESC/NO keys at the same time) For the 4-button remote keyfobs the process is slightly different:
o 1. Press and hold the ON and OFF keys at the same time for 12 seconds o 2. Wait 1 second o 3. Press and hold the ON and OFF keys at the same time for 5 seconds, you should hear 4 beeps from the keyfob. Outdoor MotionViewer Trips All the Time:
It is important to follow these basic installation tips when mounting and aiming an outdoor MotionViewer o 1. Protect your assets, not the whole area. Secure specific assets or clusters of assets rather than cover a large area where the range of the MotionViewer might extend beyond the assets and detect irrelevant objects. o 2. Terminate the view of the MotionViewer. Make sure to tilt the MotionViewer down 5-7 so that its top line of sight terminates into the ground. Taking into account all three elements; PIR, digital video camera, and infrared illuminators you will want to terminate the view of the MotionViewer at 40 ft. from the device. 28 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series XT-IP620 -SERIES AFTER INITIAL PROGRAMMING FLOW CHART Parameters are only available in Access Level 4 29 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series 30 | P a g e 2012/1/9 Ed 1.1 1. LSH20 Control Panel Batteries:
Setup and Programming manual for XT-IP620 series Addendum 2. LS14500 Peripheral Batteries:
Excludes SE601 and SE651 3. Lithium Battery Storage:
31 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series 4. Finding Manufacture Week and Year:
The Manufacture week and year can be found in the serial number of the device/control panel. The second sets of 4 numbers in the serial number are WWYY.
####0411######## = Which shows that this device was manufactured in the 4th week of 2011. 5. Event Log Ethernet Codes Log Code Ethernet Off Ethernet On Ethernet (0) Ethernet (1) Ethernet (2) Ethernet (255) Ethernet Lost Ethernet Returned Meaning Ethernet interface is OFF Ethernet interface is ON Ethernet Error No DCHP reply (after MAX DHCP RETRY) No Frontel reply (after TIMEOUT SERVER) Ethernet communication success No Ethernet cable detected Ethernet cable restored 6. Additional System Codes Codes 999996 999995 999991 999997 Maintenance request - Ethernet transmission Action Displays local IP address assigned to the control panel:
If the DHCP mode is deactivated : the static local IP of the panel will be displayed
(defined in the ETHERNET menu 7) If the DHCP is activated:
If the panel is not in transmission then 0.0.0.0 will be displayed If the panel is in transmission (the RJ45 led will be flashing) then the dynamic IP of the panel will be displayed. Sends a test alarm to IP1 Address (Primary alarm receiver) This is a quick way to check for connectivity to the monitoring center. If there is a transmission problem the panel will terminate communication faster than in an actual alarm. The system will automatically attempt connection to IP2 Address (Backup alarm receiver) in the event that IP1 is unavailable. Displays external power supply status 32 | P a g e 2012/1/9 Ed 1.1 Setup and Programming manual for XT-IP620 series 7. Replacing Device and Control Panel batteries When replacing batteries in the Videofied control panel or devices the battery replacement mode must be used. This will ensure that the low battery algorithm on the panel/device is properly reset and also helps keep the devices synced with the control panel. Devices:
Access Level 4 -> Maintenance -> Replace Batteries -> Devices The system will give you 1 minute to open any device on the system to replace the batteries. When a device is opened you will have 5 minutes to replace the batteries before the system will time out and all tampers will be active again on the system. We suggest that you start the device battery replacement for each individual device to ensure the 5 minutes does not expire and tamper signals are not sent to the monitoring station. Control Panel:
Access Level 4 -> Maintenance -> Replace Batteries -> Panel The system will give you 1 minute to open the panel. When the panel is opened it will give you 5 minutes to replace the batteries before the control panel tampers will be active again. 8. Checking control panel firmware version 1. All control panel labels on the box and inside of the cover will have the firmware version listed. 2. After completing initial programming hit the 0 key 6 times followed by YES/OK
(000000 + YES) and the firmware version will be listed. 3. Connect the panel to TMT2 using the USB or Cellular connection. The firmware version of the control panel is listed on the main screen. 33 | P a g e
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-05-05 | 904.5 ~ 926.1 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-05-05
|
||||
1 | Applicant's complete, legal business name |
RSI VIDEOTECHNOLOGIES
|
||||
1 | FCC Registration Number (FRN) |
0014919625
|
||||
1 | Physical Address |
25, rue Jacobi Netter
|
||||
1 |
STRASBOURG, N/A 67200
|
|||||
1 |
France
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
w******@cetecom.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
X46
|
||||
1 | Equipment Product Code |
XT05
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T******** P******
|
||||
1 | Title |
Product Quality Manager
|
||||
1 | Telephone Number |
+3339********
|
||||
1 | Fax Number |
+3339********
|
||||
1 |
t******@rsivideotech.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LAN Alarm panel | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CTC advanced GmbH (former CETECOM ICT Services )
|
||||
1 | Name |
G****** S****
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 904.50000000 | 926.10000000 | 0.0210000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC