technical information technical information 2 Contents 1.0 Introduction............................................................................................................. 04-07 1.1 In the Box 1.2 Principal Dimensions 1.3 Specifications 2.0 bebionic Grips......................................................................................................... 09-19 2.1 Factory Settings 2.2 Programme Switch 2.3 Thumb Adjustment 2.4 Opposed Grips 2.5 Non-opposed Grips 2.6 Further Grips and Hand Positions 3.0 bebionic Glove.......................................................................................................... 21-25 3.1 How to fit a bebionic Glove 3.2 Removing a bebionic Glove 3.3 Care Instructions for bebionic Glove 4.0 Connections & Compatibility...................................................................................... 27-35 4.1 Wrist Options 4.2 Battery Options 4.3 Power Information 4.4 System Connections 4.5 System Compatibility 5.0 bebalance ...............................................................................................................37-49 5.1 Introduction 5.2 Installation 5.3 Start up 5.4 Language Selection 5.5 Radio Frequency Module Configuration 5.6 Operating Modes 5.7 Hand Configuration 5.8 Grip Selection 5.9 Advanced 6.0 Additional Information, Warranty, Repairs and Returns...................................................51-63 6.1 Gaiter Removal 6.2 Gaiter Refitting 6.3 Clevis Link Replacement 6.4 Quality Assurance 6.5 Warranty 6.6 Returns 3 1.0 Introduction This document contains important information for the correct use and set up of the bebionic3 hand. Please note some of the images may differ as this document applies to both the medium and large size of hands. Read this document throughly before fitting a bebionic3 hand. A bebionic system is completed by adding from a selection of compatible system components including myo electrodes (or other input devices), battery systems, wrists and cables. We recommend RSLSteeper components for all of these requirements. The bebionic3 hand is designed for mild to moderate activities. Its use in situations where heavy loads, vibrations or impacts may be encountered must be avoided. Key:
WARNING Texts with this symbol need special attention. They contain information to do with safety.
! Caution Texts with this symbol draw your attention to potential sources of damage to the hand. 04 1.1 Whats in the box 5. 6. 7. 1. 2. 3. 4. 1. bebionic radio frequency (RF) module 2. bebionic3 hand 3. bebionic tool kit 4. bebionic in car charger 5. bebalance3 programming software 6. bebionic3 user guide 7. bebionic3 technical information 05 1.2 Principal Dimensions C B X A X D Principal Dimensions A Middle Finger Tip to Hand Base B Thumb Tip to Hand Base C Max Chassis Width (no glove) D Diameter of Chassis at Wrist Palm Circumference (no glove) Large 200mm 125mm 92mm 50mm 220mm Medium 190mm 121mm 84mm 50mm 204mm Maximum Opening Width - Tripod Grip 105mm (with glove) 105mm (with glove) Thumb Swing Through Angle X EQD Only 06 68o 5mm 68o 5mm 1.3 Specifications Part Number Build Height Weight Description BBHLG*QD 125mm + 25mm 598g bebionic3 Large Hand with EQD Wrist BBHLG*FW 125mm + 37mm 557g bebionic3 Large Hand with RSLSteeper Friction Wrist BBHLG*SW 125mm + 12mm 577g bebionic3 Large Hand with Short Wrist BBHLG*EU 125mm + 16mm 574g bebionic3 Large Hand with M12 Thread Stud BBHLG*NA 125mm + 16mm 572g bebionic3 Large Hand with 1/2 x 20 UNF Stud BBHMD*QD 121mm + 25mm 591g bebionic3 Medium Hand with EQD Wrist BBHMD*FW 121mm + 37mm 550g bebionic3 Medium Hand with RSLSteeper Friction Wrist BBHMD*SW 121mm + 12mm 570g bebionic3 Medium Hand with Short Wrist BBHMD*EU 121mm + 16mm 567g bebionic3 Medium Hand with M12 Thread Stud BBHMD*NA 121mm + 16mm 565g bebionic3 Medium Hand with 1/2 x 20 UNF Stud Build height comprises of thumb tip to base of hand measure, followed by the build height for each wrist option. The second number refers to the minimum allowance for the mating wrist unit.
*Denotes side of hand, i.e. insert L for a left hand, or R for a right hand. Maximum Power Grip Force Maximum Tripod Grip Force Maximum Key Grip Force Maximum Time to Open or Close - Tripod Grip Maximum Time to Open or Close - Power Grip Maximum Time to Open or Close - Key Grip Maximum Static Load - Hook Grip Maximum Load Individual Finger - Hook Grip Maximum Finger Tip Extension Load Maximum Safe Vertical Load Taken Through Knuckles Large 140.1N 36.6N 26.5N 0.5 Seconds 1.0 Seconds 1.0 Seconds 45Kg 25Kg 6Kg 90kg Medium 140.1N 36.6N 26.5N 0.5 Seconds 1.0 Seconds 1.0 Seconds 45Kg 25Kg 6Kg 90kg 07 2.0 bebionic grips 08 The bebionic3 hand provides a number of grips, allowing the user to have a more complete device to assist them in their day to day life. The hand has two selectable thumb positions: opposed & non-opposed. Opposed is where the thumb is in opposition to the fingers on the hand, allowing grips like pinch and power. Non-Opposed is where the thumb is parallel with the fingers of the hand and allows grips like key and finger point. Opposed Non-opposed 09 Introduction 2.1 Factory Settings 2.2 Programme Switch The hand is supplied preset in Mode 4. This provides two input operation with proportional control of grip and speed. Speed & grip force are set to maximum. To alternate between default and alternative grip pattern, an OPEN OPEN signal must be applied (i.e. the hand must be fully opened, the signal relaxed and then a second open signal supplied). To alternate between the primary grip pattern table and secondary grip pattern table, press the Programme Switch for less than 2 seconds. The Auto Grip feature is turned off. Primary Opposed Default - Tripod Alternative - Power Primary Non-Opposed Default - Key Alternative - Finger Point Secondary Opposed Default - Active Index Alternative - Tripod Secondary Non-Opposed Default - Column Alternative - Mouse 10 A Programme Switch is provided on the back of the hand. This has four functions;
1. Switch the hand ON and OFF A single press for approximately three seconds will switch the hand OFF. A single press for more than two seconds will switch the hand ON. 2. Alternate between the primary and secondary grip patterns When the hand is switched ON, a single press of less than two seconds will alternate between the primary and secondary grip patterns. This will be accompanied by a short bleep and vibration (if activated on bebalance). 3. Enable / disable the in-hand RF module With the hand switched ON, a single press for more than four seconds will enable the RF module. Pressing the switch again for more than two seconds or disconnecting the power to the hand will disable the RF module. 4. Enter / exit glove mode as follows With the hand switched OFF, press the button until the thumb begins to drive in. Then release the button.
! Caution Thumb adjustment MUST be done by a qualified technician or practitioner. 2.3 Thumb Adjustment. To achieve certain grips it is necessary to adjust the thumb position. There are two different planes to move the thumb in and they are detailed below. Underside of Thumb Bracket 1. Thumb ML Adjuster 2. Thumb Contact Point Adjuster An adjuster is provided to allow repositioning of the thumb for contact with either the index and middle fingers, as in Tripod Grip, or with index finger only, as in Pinch and Precision Grips. The thumb pivot assembly is fitted with a slotted screw as shown in diagram 1. This acts to adjust the friction on an internal clamp and is loosened by turning two complete turns and pushing the screw inward. With the clamp slackened the thumb position can be manually re-positioned. The assembly must be retightened before electrically driving the thumb. WARNING Please ensure screw is securely tightened before resuming use. An adjuster has also been provided to alter the baseline position of the thumb in order to optimise the contact point of the thumb tip against the opposing finger(s) for Tripod, Pinch and Precision Grips. This is done by moving the thumb either towards the palm or away from the palm. This adjuster is located under the thumb bracket as shown above. Using a hex drive the adjuster should be turned clockwise to move the thumb towards the palm and anticlockwise to move the thumb away from the palm. The effect will not be observed whilst making the adjustment and can only be observed by resetting the hand i.e. switching the hand OFF and ON again. 11 Grips 2.4 Opposed - Thumb is opposite to the fingers Tripod Pinch the To achieve this grip it is necessary to be manually for thumb repositioned by the practitioner/
technician so that the thumb only contacts
(See section 2.3). The thumb only contacts index finger and is used for the fine manipulation of objects. index finger the When the thumb is opposed, the hand closes into Tripod Grip with index and middle fingers meeting the thumb. Ring and little fingers continue to close until they meet resistance or the close signal stops. This type of grip allows users to pick up, hold and manipulate a variety of everyday objects such as car keys, coins, jar lids and pens. 12 SERIOUS WARNING NEVER use a bebionic hand with firearms. Power Active Index (Formerly Trigger) With the thumb opposed, all four fingers close into the palm until they meet resistance or the close signal stops. When fingers are approaching a fully closed position, the thumb drives in to cover the fingers for additional grip security. This pattern allows round objects such as a ball or a piece of fruit to be held securely. This grip can also provide a handshake. Cylindrical shaped objects such as bottles, home & garden utensil handles are also held easily and securely. With the thumb opposed Active Index Grip will grasp the handle of an object with the middle, ring and little fingers and secure the grip with the thumb. The index finger will then close this may be positioned over the lever of the device held such as a spray bottle. The index finger is under independent user control and may be positioned accordingly. To exit Active Index, an open signal will fully open the index finger before the other fingers and thumb release their grip. 13 Grips 2.5 Non-Opposed - Thumb is inline with the palm. Key Finger Point In the non-opposed thumb position, the four fingers partially close. The thumb then closes onto the side of the index finger. The thumb position may be raised and lowered without moving the other four fingers allowing for release, capture or reposition of the object being gripped. This pattern is ideal for carrying paper or letters, using a spoon and for holding a thin flat object such as a plate, a credit card or a key. With the thumb in the non-opposed setting, the user can move to a Finger Point position. The middle, ring, and little fingers close against the palm and the thumb moves against the middle finger. With this grip, typing on a keyboard or input pad, pressing a bell or a button can be achieved. 14 Column Mouse This grip moves the thumb into the palm from a non-opposed position. The fingers then close over the thumb to provide a fixed column that can be used as a way to push heavier objects or larger buttons and switches. Column is also the recommended grip for dressing, as the thumb is kept out of the way. With the thumb non-opposed, the thumb and little finger close to hold the side of the mouse, with the middle and ring fingers providing stability. The index finger closes on to the mouse button and then backs off to provide the button press. Each close signal will give a mouse click whilst an open signal will release the mouse. 15 Grips 2.6 Further functions of the bebionic3 hand. Precision Open Precision Closed To achieve this grip it is necessary for the thumb to be manually repositioned by the practitioner/
technician so that the thumb only contacts the index finger. With the thumb opposed, the index finger meets the static thumb allowing the user to pick up and manipulate small objects. When this grip is selected and a close signal is applied, the thumb closes to the midpoint of its range and pauses. The index is then active and under user control. The middle, ring and little fingers remain extended. 16 the To achieve this grip it is necessary to be manually for thumb repositioned by the practitioner/
technician so that the thumb only contacts the index finger. This grip can be used in situations similar to the Precision Open Grip but where extended fingers would be obstructive, when working at a desk for instance. Initially the middle, ring and little fingers close into the palm. The thumb moves to the midpoint of its range and pauses. The Index is then active and under user control. Hook Finger Adduction With the thumb in opposed, a partially closed Power Grip gives the Hook Grip.This is ideal for carrying a shopping bag or briefcase. together naturally as The fingers of the bebionic hand move the fingers close. This allows the user to securely grip thin objects, such as cutlery or a toothbrush, between the fingers to achieve function in a different plane. Finger Adduction is most functional with the hand in Power Grip but can also be achieved with the hand in Key and Pinch. 17 Grips 2.6 Further functions of the bebionic3 hand. Open Palm Relaxed Hand With the thumb in the non-opposed position the hand may be fully opened to provide a flat palm suitable for carrying a tray or a plate. The thumb is set to the non-opposed position and partially driven in toward the palm. All the fingers are driven to a slightly flexed position. Applying a further signal will drive the fingers into a carrying position. 18 be yourself 19 3.0 bebionic glove 20
! Caution There is no alternative manufacturer of cosmetic gloves for the bebionic hand and wrist. The use of other gloves may damage the hand and will void the warranty. The bebionic glove is made from a multi-layered, variable hardness, silicone based material, lined with fabric mesh. This construction resists soiling, wear and puncture damage. bebionic gloves provide high compliance with gripped objects. The fabric liner also allows the glove to slide over the joints during motion, this reduces the amount of power need to drive the hand and increases battery life. The standard glove is supplied in 19 skin tones and also in a solid black colour. bebionic gloves provide an additional barrier to dirt, dust and moisture ingress to the hand. Direct exposure to water, or situations where dirt and dust are prevalent should be avoided as these have the potential to interfere or damage the hands performance. 21 bebionic glove 3.1 fitting the bebionic glove Move the thumb into the opposed position. 1. 2. Switch the hand OFF by pressing down the programme switch on the back of the hand for approximately three seconds.
! Caution Do not use talcum powder or lubricant when fitting the glove. 5. Fold up the base of the glove. 6. Pull the glove over the hand 22
! Caution Do not attempt to fit the glove unless the hand is in glove donning mode. 3. Press and hold the programme switch for four seconds. The hand will automatically drive into glove mode 4. The thumb will be in the position shown above when the hand is in glove mode. 7. Ensure the fingers and thumb of of the hand align correctly with the fingers and thumb of the glove. 8. Hold down the programme switch for four seconds to exit glove donning mode and begin using the hand. 23 bebionic glove 3.2 Removing the bebionic glove 1. Firstly oppose the thumb. Then turn the hand OFF by holding down the programme switch for approximately three seconds. Next put the hand into glove donning mode by holding down the programme switch for 4 seconds. 2. Roll up the base of the glove and pull the whole glove off from the back of the hand. 3. Do not pull the fingers individually as this can damage the glove and hand. 4. Exit glove donning mode by pressing and holding the programme switch for 4 seconds; the hand will automatically drive out of glove donning mode and will be active in the default grip. 24 bebionic glove 3.3 Care instructions and information Care Take care when fitting and using silicone cosmetic gloves. Try to avoid contact with sharp or pointed objects. The material used will resist most staining media. High Definition Nails Silicone gloves have nails painted by hand following the manufacturing process. Bonding to the base material is good. We do not recommend the use of polystyrene nails attached with Cyano-acrylic glue as attempts to remove the nails bonded with this adhesive will permanently damage the glove. Cleaning General soiling can be removed with soap and water. After cleaning remove all traces of the cleaner and wipe the surface dry. Most dyes will be fully removed by this process. A liquid domestic fabric softener can be used in solution to reduce the tackiness of the surface. For any other enquiries please use the contact details supplied on the inside cover of this document. 25 4.0 connections & compatibility 26 A bebionic system is very versatile and allows a number of different wrist, power and connectivity options. Most options are detailed in the following section of this document. However if you have a question regarding a specific build not outlined in this document please contact RSLSteeper. The bebionic hand may also be used with other manufacturers electrodes and wrists. This means the bebionic3 hand can be fitted into an existing system without having to change every single component of the system. 27 4.1 Wrist Options There are currently 4 wrist options for the bebionic hand. Electric Quick Disconnect
(EQD) -
Short Wrist -
Allows the hand to be removed with a rotating action. The EQD wrist allows the patient to quickly rotate and remove/
attach terminal devices as required. Low profile connector for applications where there is a long residual limb. A short wrist lamination assembly is supplied attached to these hands. The hand can be rotated against a constant friction, which can be adjusted by the patient. 28 Threaded Stem -
A hand plate with a threaded stud is pre-
fitted. Two thread options can be supplied USA or European standards are available. Friction Wrist -
Interfaces with a RSLSteeper 50mm, friction wrist (part C12810). These hands are supplied pre-fitted with a Friction Wrist hand plate. The wrist has user adjustable friction that can be adjusted at any time through a simple twist action. This option produces rotations through a range of 320 degrees. 29 4.2 Battery Options WARNING Only the following battery options should be used with the bebionic3. Use of other battery systems is not recommended. BBI=2200 Typical Capacity:
2200mAh BBI=1300S Typical Capacity:
1300mAh BBI=2200S Typical Capacity:
2200mAh Voltage (Nominal): 7.4V Voltage (Nominal): 7.4V Voltage (Nominal): 7.4V Size: 18.5mm x 36.5mm x 70mm Size: 8.6mm x 3mm x 66.5mm (x2) Size: 18.5mm x 18.5mm x 70mm (x2) 30 4.3 Power Information WARNING System cables MUST NOT be cut while power is ON. This will short the battery and will damage the system. Any damage caused is considered to be outside of the bebionic warranty. Power Cables A bebionic hand uses five actuators and therefore requires a higher current supply than single motor devices. This can be accommodated safely using bebionic power cables. Other power cable types may not be efficient or safe. However, cables from other manufacturers may be adequate for signaling application. Low Power Condition When the battery capacity approaches its lower limit, the hand will begin to slow. With continuous use it will eventually stop. If the hand stops in a closed position the user can apply a series of open signals to fully open the hand. The hand will remain in an open position until the battery is recharged. Battery Switch / Charging Module A ON/OFF switch is integrated into the charge module. The switch disconnects power completely, and has 2 positions. When the switch is positioned closest to the charge point, power is OFF and the battery can be charged by connecting the lead from the bebionic charger. When the switch is furthest away from the charge point, power is switched ON. Connecting the charger to the charge plug will have no effect on the battery. The ON/OFF switch / charge module is fitted to the battery and requires an additional connector cable to link to the hand. The connector cable for EQD hands, as shown on page 32, is supplied with each battery. For short wrist, friction wrist, or threaded stud wrist options a different connector cable (CBBHA72), as shown on page 20, will need to be ordered separately and connected to the battery pack after removing B27804. A small laminating dummy is included in the kit. Prior to lamination this is placed in a suitable location and orientation on the forearm model. The position is chosen to allow sufficient space between the inner and outer sockets and to allow easy access to the switch and plug point by the user. WARNING The prosthesis MUST NOT be worn whilst the batteries are charging. WARNING It is NOT recommended to route the power supply to the hand without passing through the switch. 31 4.4 System Connections The system detailed below is suitable for a bebionic hand with an Electronic Quick Disconnect Wrist BBI=2200 bebionic 7.4v 2200mAH battery BBI=2200S bebionic 7.4v 2200mAH split cell battery B27804 Battery Switch
& Charge Point with Cable. E.50/E.60 2 X Electrode 50Hz or 60Hz BBI=1300S bebionic 7.4v 1300mAH split cell battery QDACO Co-axial plug Please note: Part B27804 is supplied with each battery pack and do not need to be ordered separately. Components not to scale. 32 The system detailed below is suitable for a bebionic hand with either a Short Wrist, a Friction Wrist or a Threaded Stem BBI=1300S bebionic 7.4v 1300mAH split cell battery CBBHA72 Connector Cable BBI=2200 bebionic 7.4v 2200mAH battery BBI=2200S bebionic 7.4v 2200mAH split cell battery B27804 Battery Switch
& Charge Point with Cable. E.50/E.60 2 X Electrode 50Hz or 60Hz Please note: Part B27804 is supplied with each battery pack and do not need to be ordered separately, however part CBBHA72 will need to be ordered separately for hands with short wrist, friction wrist, or threaded stem wrist options. Components not to scale. 33 4.5 System Compatibility The bebionic hand is potentially compatible with a number of different parts from other suppliers. A common list is shown on the page opposite. Please adhere to the advice given below.
! Caution The bebionic system has not been exhaustively tested with all alternative electrodes, wrists and control systems. Any damage caused will be held to be outside of the design parameters of our system. The statements above do not imply that RSLSteeper recommend or warrant these combinations. We believe that, on the basis of statements in the literature from these manufacturers that these combinations will work effectively but it is for the bebionic practitioner to test and warrant the combination. These combinations may invalidate warranties given by other manufacturers. The practitioner should confirm the warranty position with these manufacturers. Electrodes We recommend RSLSteeper E.50 or E.60. Both are available to purchase and are optimised for use with bebionic3 34 Inputs RSLSteeper Otto Bock Otto Bock Otto Bock LTI LTI Elbows Supplier Part Number Type of Input E.50 & E.60 9X18, 9X37 MyoElectrode Switch 13E125, 13E200, 13E202 MYOBOCK electrode 9X50, 9X52 DC200B=
TP01, TP02 Linear Transducer MyoElectrode Force Sensitive Resistor Supplier Part Number Name Otto Bock Otto Bock LTI Motion Control Wrist 12K44=
12K50=
BE330 ErgoArm Hybrid plus ErgoArm Electronic plus Boston Elbow Digital Utah Arm 3 & 3+
Supplier Part Number Name Otto Bock Motion Conrol 10S17 + 13E205 Wrist Rotator and MyoRotronic MC Wrist Rotator Wrist Mode Type Compatibility Program 1 Program 2 Program 3 Program 4 Program 5 2 Electrodes - Fast Rise bebionic Mode 4 2 Electrodes - Co-Contraction bebionic Mode 4 2 Electrodes - Safety Co-
Contraction 2 Electrodes + 1 Switch - Actuate
& Hold 1 Electrode - or 1 Linear Transducer - Quick Pull bebionic Mode 4 bebionic Mode 4 & Mode 5 bebionic Mode 0 & Mode 3 Please note: Devices or components not listed above are not recommended. 35 5.0 operating instructions 36 bebalance3 has been designed to give you optimum control over the new bebionic3 hand. It features many new tools which will help you and your patients optimise and customise the function of the hand. Language selection, electrode configuration with a simulation preview and simplified menu systems are all included in bebalance3. Note: Installation disc is affixed to the inside back cover.
! Caution Please DO NOT programme or control a bebionic system with unapproved, alternative software or hardware systems. Doing so will void the warranty. 37 5.1 Introduction Out of the box, the bebionic hand is pre-configured with two site proportional myoelectric control (Mode 4) where an OPEN OPEN signal is used to change grip patterns. This mode has been chosen to provide a standard solution that works well for the majority of users who demonstrate two, well controlled muscle signals. However, bebalance3 is particularly useful if muscles produce limited or difficult to control signals, as is often the case with the higher-level amputation. With bebalance3 the practitioner may adjust the operation of the electrode, reset co-contraction signals, change signal timing features, choose between one or two electrode or transducer control and enable the Auto Grip feature. All are able to enhance the users natural control capability. bebalance3 software also provides the ability to record patient information and to record a history of configuration settings for each hand. The programming of the hand requires a USB radio dongle (supplied) to be plugged into the hosting computer, which when activated, links to the radio module in the bebionic3 hand. There is also the capability to read the current configuration back from the hand and store it against the user record.
! Caution This software is not intended for patient use. Alterations should be made by the practitioner ONLY. Caution
Only bebionic v2 and bebionic3 hands can be programmed using bebalance3 38 5.2 Installation 1. 2. 3. 4. Close all open applications Insert CD into your CD-ROM Wait for Autorun Follow instructions on screen 1. The default target directory is C:\users\
USERNAME\bebalance3 You can choose an alternative should you wish; however it should be noted that it is essential that the bebalance application directory and sub-directories have read & write permission. CP210_Win2K_XP_Vista or CP210_Win7 folder. If using a retro operating system it may be necessary to use software specific to the computer build. The latest version of the software can be found at www.rslsteeper.com/downloads If setup fails to automatically open, run it manually from the BBsetup.exe bebalance V2 can co-reside with bebalance3. If you are re-installing bebalance3, the existing version MUST be uninstalled. Although the existing database will be retained, it is advised that the previous version is backed up before proceeding with this installation. requires The bebalance3 application
.Net Framework 4.0 to operate. If not installed it can be installed from the CD by opening dotNet folder and double clicking on Framework dotNetFx40_Full_x86_x64.exe Similarly the radio dongle requires software to be installed to operate. Specific versions can be found in 39 5.3 Start up 5.5 Radio Frequency (RF) Module Configuration On opening the application the main screen shown above will appear. Any greyed out options are currently not operational. The area highlighted in red identifes the bebalance version number. bebalance now has an auto-detect feature for the radio. You are advised to insert the RF dongle into a USB port of the computer before starting the application as it will be detected on start-up. 5.4 Language Selection At the bottom of the entry screen there are hyperlinks available to select the appropriate language. Those available are: English, French, German, Spanish and Portuguese. However, if you forget, just insert the dongle and either return to the entry screen menu as highlighted above. Or, on the configuration screen, click on the button marked Radio. When the radio dongle has been found the message box will show RF Dongle Found highlighted in green. If not found the message box will show No RF Dongle Enabling RF Module on the bebionic Hand With the hand switched ON, press and hold the programme switch on the back of the hand for approximately three seconds until the RF dongle begins to flash continually. Note: This function differs from the glove donning mode as to enable the RF Module the hand must be switched ON, whereas in glove donning mode the hand is first switched OFF. The RF Module can be disabled by pressing for more than 2 seconds. Alternatively you can disconnect the power to the hand by using the battery switch. 40 5.6 Operating Modes There are six modes. These are selected from the highlighted box, along with the appropriate control strategy. Note: Grip change will generate a bleep and / or vibration if this feature is enabled. Mode 0 Control Strategy Single Site Threshold
-To OPEN hand apply signal
-To CLOSE hand remove signal Grip Patterns Thumb Opposed up to 4 grip patterns Thumb Non-opposed - up to 2 grip patterns Mode 1 Control Strategy Single Site Proportional / Threshold
-To OPEN hand apply a short burst signal
-To CLOSE hand apply a sustained signal
-To switch between default grip and alternative grip apply a further OPEN signal within variable time (up to 2 seconds) of the hand fully opening. Grip Patterns Thumb Opposed up to 4 grip patterns Thumb Non-opposed - up to 4 grip patterns Mode 2 Control Strategy Single Site Proportional / Threshold
-To OPEN hand apply a quick rising stimulus
-To CLOSE hand apply a slow rising stimulus
-To switch between default grip and alternative grip apply a further OPEN signal within variable time (up to 2 seconds) of the hand fully opening. Grip Patterns Thumb Opposed - up to 4 grip patterns Thumb Non-opposed - up to 4 grip patterns Mode 3 Control Strategy Single Site Proportional / Threshold Alternating
-To OPEN hand the first signal will OPEN the hand; a configurable delay of 50ms to 2.0s will allow repeat OPENS if required.
-To CLOSE hand a signal applied outside of the delay will CLOSE the hand; a configurable delay of 50ms to 2.0s will allow repeat CLOSES if required
-To switch between default grip and alternative grip apply a further OPEN signal within variable time (up to 2 seconds) of the hand fully opening Grip Patterns Thumb Opposed - up to 4 grip patterns Thumb Non-opposed - up to 4 grip patterns Mode 4 Control Strategy Dual Site Proportional / Threshold OPEN OPEN
-To OPEN hand apply signal from OPEN electrode
-To CLOSE hand apply signal from CLOSE electrode
-To switch between default grip and alternative grip apply a further OPEN signal within variable time (up to 2 seconds) of the hand fully opening Grip Patterns Thumb Opposed up to 4 grip patterns Thumb Non-opposed up to 4 grip patterns Mode 5 Control Strategy Dual Site Proportional / Threshold Co-
contract
-To OPEN hand apply signal from OPEN electrode
-To CLOSE hand apply signal from CLOSE electrode
-To switch between default grip and alternative grip apply a co-contraction signal Grip Patterns Thumb Opposed up to 4 grip patterns Thumb Non-opposed up to 4 grip patterns Please note: Where more than one grip pattern is available, the practitioner can select the default and alternative grips for both the primary and secondary grip patterns using bebalance programming software. Pressing the programme switch on the back of the hand allows the user to alternate between the primary and secondary set of grip patterns. to Mode 4 with The hand will be delivered pre-set to provide an operational hand default values set straight out of the box. Configuration via bebalance may therefore not be essential pre-fitting. 41 5.7 Hand Configuration Introduction Hand Configuration Select bebionic on the main menu to open the configuration screen as shown below. The No RF Found message may be replaced with RF Dongle Found. By default the configuration screen opens with dual
-site control strategy. You can change to single-site by point & click on the single-site radio button under Control Strategy. For most patients, the factory settings on the bebonic hand will be adequate. However, for experienced practitioners bebalance software can be used to customise each hand to each individual through the bebionic menu option. Configuration essentially changes the way the bebionic hand operates. These changes are downloaded from the computer to the hand to allow the user to try them. Successful alterations can be loaded and saved in the hands memory. Details of individual iteration, once saved, are with the patients ID in the History file.
! Caution Only bebionic v2 and bebionic3 hands can be programmed using bebalance3 42 5.8 Grip Selection Grips can be selected and ordered as desired by the user by a simple point and click in the relevant tables. Control Option The hand can be controlled by proportional or threshold electrodes or alternatively by linear transducers or force sensitive resistors. It is possible to reverse the electrode/
transducer operation without the need to physically swap cables. By simply clicking on the electrode radio buttons highlighted below. Change Indication Function change indication is available by ticking either beep or vibrate, both or none as highlighted below. Opposed Primary This enables selection of the initial two grip patterns available with the thumb in the opposed position. The default grip is available immediately, the user can switch to the alternate grip by applying the appropriate change signal e.g. in mode 4, an OPEN OPEN signal will switch between the default and alternate grip patterns. Non-opposed Primary Allows selection of the grip patterns as described above, but with the thumb in the non-opposed position. Opposed Secondary This enables selection of a further two grip patterns with the thumb in the opposed position. These grips are activated by pressing the programme switch on the back of the hand. As with the primary grip patterns, the user can switch between the default and the alternate grip by applying the appropriate change signal. The user can return to the primary grip patterns by pressing the programme switch. Non-opposed Secondary Allows selection of the grip patterns as described for Opposed Secondary but with the thumb in the non-
opposed position. 43 Auto Grip This feature can be set to enabled or disabled. Note that Auto Grip functions in Tripod Grip only. Auto Grip is activated by providing three consecutive close signals. De-activation occurs when the hand is opened. Re-
activation is made again by three consecutive close signals. Save The hand can be configured and the settings sent to the hand without saving if you want to give them a try. If you wan to retain these settings for further amendment or back-up you need to click Save. Before the data is saved a patient identifier must be entered. There is a description field for recording specific information as necessary. When Auto Grip is active, the electronics monitors motor position for movement. If movement /slippage of an object is detected, the finger position/grip force is automatically altered to provide a more secure grip. Electronic monitoring of this process occurs every 50ms. Horizontal Buttons Reset If at any time you want to start again with your configuration, clicking Reset, resets all the controls to the default settings for the current mode. History Clicking History opens a list of saved configurations. By entering a patient identifier and clicking on the Find button you can filter the records to only show the relevent records. This feature enables the recovery of previous settings for re-sending to the hand or providing a base to work from. 44 Send to Hand With the radio dongle inserted and configured and the radio activated on the hand. It starts transmitting a stream of signals, which can be identified by the rapid flashing of the LED on the dongle. Clicking Send to Hand starts the transmission of the current configuration to the hand. On completion the message panel on the right will show success or in failure of the process. Radio This enables connection of the radio module should you forget to install the dongle before running the application. When the dongle is found the message box will RF Dongle Found highlighted in green. If not found the message box will show No RF Dongle highlighted in red. See section 8.1 for more information. Read from Hand This feature enables the current hand configuration to be read from the hand and stored in the history file. Following a read you are required to enter a patient identifier. This enables retrieval of the specific patient configuration, if desired. Quit This will close the configuration form and return to the main entry screen. 45 Vertical Buttons Electrodes Selecting Electrodes from the vertical button menu opens a form, shown second below. This allows electrode signals to be monitored, reviewed and adjusted. The sliders identified are for independently adjusting on-
threshold and maximum levels of the individual channels on the hand. With the signals displayed the electrode threshold and maximum levels can be adjusted with the relevant sliders, which reposition the blue and red horizontal lines in the associated display panels. The strength of the signal is displayed as a green vertical bar with the peak signal indicated as single green line. On closing the form the settings are retained for configuring the hand using the Send to Hand option. The embedded animation system enables modification of the threshold settings to be sampled without the need to keep sending data to the hand. These can then be sent to the hand once the user is comfortable with the settings. The animation system can also be used as a pure training aid without the need for a bebionic hand. However a training tower (XXXXXXX) and radio module
(XXXXXXX) will be required. To turn on, point & click on Proportional Animation or Threshold Animation as highlighted below. The off threshold is a predetermined offset from the on level. The on level (blue line) determines the level the electrode signal must reach before it is active. Once the signal reaches this level the hand operates until the signal drops below the predetermined off level. The maximum level (red line) sets the proportional range of the signal input. The animation shows Tripod Grip as the default which, will open and close in response to the electrode signals. By applying an OPEN OPEN signal within a definable period (default 1sec) the hand will change to / from a Power Grip. This system provides a useful myo assessment tool for the upper extremity amputee and also provides an entertaining aid for use, both pre and post prescription. 46 Co-Contraction Selecting Co-Contraction opens a form, shown below, to monitor and set the co-contraction signals. The black horizontal lines identify the co-contraction level and can be adjusted as necessary. The horizontal lines on the display area move simultaneously with the vertical slider. In Mode 5, co-contraction is used to move between default and alternate grip patterns. The blue horizontal lines show the on threshold level set during the myo configuration process and can be adjusted from this option if necessary. The horizontal slider highlighted above (centre left) can be used to set the co-contraction time window. A co-contraction signal is considered to exist when signals from both channel 1 and 2 pass through both the on threshold and co-contraction within a desig-
nated timeframe (co-contraction window). With the bebionic hand there is a 'soft' co-contraction option where the co-contraction threshold can be set lower than the on threshold level. Providing that the peak signal does not exceed the on-threshold, a co-contraction signal will be considered to exist. The slider items highlighted on the image above are used to set the required characteristics of co-contract signals. Clicking Start will initiate tracing of the electrode signal. One channel will be displayed with raising signals moving upward and the second channel raising signals moving downward. When the trace reaches the right hand side of the display it will stop. To continue click Clear, this will remove the previous trace and automatically start a new one. If you wish to stop the trace at any point, click Stop. The display period can be changed by selecting the appropriate time period (10, 20 or 30 seconds) from the display period drop down (top left). 47 5.9 Advanced Features In bebalance3 the basic features can be selected by simply clicking on the appropriate radio button or check box control. Adjustment of more specific features can be done by clicking Advanced. This opens an overlay form similar to the screen highlighted below. The features displayed will be appropriate to the mode selected. Grip Current It is possible to selet High, Medium or Low Grip Current. This setting provides adjustment of grip strength and battery consumption; the lower the setting the lower the grip and current draw. Note: This has minimal effect on operation speed. Speed Control Should you want to open or close the hand at less than maximum speed, the numeric up/down controls provide independent hand opening and closing speeds; 40
(default) being maximum. 48 Timer Control For modes 1, 2, 3 & 4 there are two numeric up/
down controls to change mode timings. The upper control Mode Change Period sets the window of time to search for a mode change signal. In these modes additional signals received will have have no effect and will be considered to be the same signal. The lower control Mode Return Period sets the period after which the mode reverts to default where there has been no activity. Setting the slider to zero deactivates the revert feature. For Mode 5 there is no upper control as mode change is activated by a co-contraction signal. Dwell Threshold (Upper & Lower) This feature is only used on Mode 1. The Upper control sets the time that the signal has to exist to be identified as a CLOSE signal. The Lower control sets the value for the period a signal has to be held once considered an OPEN signal. Signal Select & Increase on Threshold This feature offers Open & First protocols. The default is Open which means that the hand will move in response to receipt of the larger signal if both exceed the electrode on threshold. When the First option is selected, the hand will open on receipt of the first signal to exceed the threshold and remains with this signal even if a larger opposing signal is received. The exception to the First signal protocol is when an opposite signal exceeds the value of the controlling signal by the amount set on the Minimum Dwell Threshold control. If this happens the larger signal becomes the dominant signal. If multiple signals are received to open and close, the hand will continue to open unless the close signal exceeds the amount set on the Minimum Dwell Threshold control, which is a value above the standard electrode level. Dwell Threshold (Min & Max) This feature is only used on Mode 2. The minimum control sets the level that the signal has to exceed within a time set by the maximum control. Direction Change Timer This control is used in Mode 3 only. It is used to set the additional time window when a second signal will be accepted as an additional same direction movement. If set to zero, hand movement will alternate with the next detected signal. be confident 49 6.0 additional information, warranty, returns and repairs 50 There are a number of field repairs and replacement parts that are available for the bebionic3. The instructions for how to do this are described in this section. For further advice on any repairs please contact your bebionic distributor or email: enquiries@rslsteeper.com. For both parts and service, please mention that the hand is a bebionic3 hand; including details as the whether it is Large or Medium, Left or Right and the date of purchase. 51 Repairs 6.1 Gaiter Removal 1. Pull the rear strap down and over the EQD to reveal the serial number on the back of the hand. 2. Tilt the hand backward and stretch the strap over the bottom of the EQD. 5. Pull the gaiter away from the palm of the hand, making sure that the thumb cable stays in position. 6. Taking care to avoid the thumb cable, pull the gaiter over the thumb and off the bebionic3 hand. 52 3. Using the screwdriver with the 1.50mm hex bit contained within the toolkit, loosen the screws in the rear cover. Note: Do not completely remove. 4. Slide gaiter flaps out from under the rear cover. Completely remove the gaiter from the hand. 7. 8. Note the thumb cable position, as this is key when refitting a new gaiter. 53 Repairs 6.2 Gaiter Refitting 1. Slide the thumb section of the gaiter over the thumb. Ensure the gaiter strap is under the thumb. Pay special attention to the thumb cable position. 2. Ensure the thumb section of the gaiter is pushed all the way to the gap shown in the image above. 5. Carefully push the flap all the way home under the rear cover. 6. Ensure there is as small a gap as possible between the gaiter and the rear cover. 54 3. Pull the gaiter strap around to the rear of the hand and up over the EQD. 4. Line up the sections of the hand highlighted with the sections of the gaiter highlighted when pushing the gaiter flaps under the rear cover. Pay special attention to the thumb cable position. 7. Retighten both of the screws in the rear cover. Note: Do NOT overtighten. Finished!
8. 55 Repairs 6.3 Clevis Link Replacement 1. 5.1 The clevis link has been designed to bend, should the hand be excessively loaded during use. If this should occur the part will need to be replace so that the finger can be driven again. 2. Circle indicates correct side for inserting pivot pin. Firstly ensure the thumb is in the non-opposed position and that all of the fingers are fully driven open. Then remove the pivot pin with the bebionic pivot removal pliers (Part:508-27430*). Alternatively the pivot can be removed with the pin punch provided in the tool kit.
*available for purchase seperately. 5. Keeping the finger flexed, use needle point pliers to insert the pivot pin through both parts of the link. Note: The pin is tapered and can only be inserted from the side with the circle detailed in image 5.1. 56 6. Using a pair of standard pliers ensure that the pivot pin sits flush with the surface on both sides of the link. 3. Using a spare clevice link from the tool kit. Place it into the slot in the proximal. Ensure that the curve of the clevice link curves away from the finger towards the palm. 4. Bend finger forward to align the holes for the pivot pin. Note: Clevis curving towards the palm. 7. Ensure that the finger flexes fully forward and springs back to the upright position as shown in the two images above. Finished!
8. 57 6.4 Quality Assurance RSLSteeper operate a UKAS approved quality management system and fully complies with the requirements of BS EN ISO 9001:2008, ISO27001:2005 & TickIT Issue 5. This certifies that RSLSteeper meet the appropriate international quality standards for design, manufacture and supply of prosthetic products and user software. RSLSteeper is registered with both the Medicines and Healthcare Regulatory Authority in the UK and the Food and Drugs Administration of the United States Government for the manufacture and supply of prosthetics and orthotics products. MHRA Registration N: CA001031 FDA Registration N : 9612243 FCC Registration N : PBBGC350616 IC:ID : 10634A-RSLRFBB Model N: RSL-RP609 Continued compliance with the standard is monitored by a programme of internal and external based audits. All individual products are marked indicating that they comply with the requirements of the Medical Devices Directive 93/42/EEC (MDD). The mark may be applied on packaging, accompanying literature or an enclosure, rather than the product itself. The bebionic hand and its associated components listed in this document are covered by test certificates for:-
BS EN 60601-1-2-2007 BS EN 60601-1-2006 BS EN 60950-1-2006 ETSI 300 440-2 V1.3.1 (2009-03) Electromagnetic Compatibility for RF Module ETSI 301 489-3 V1.4.1 (2002-08) Electromagnetic Compatibility for RF Module Electromagnetic Compatibility for Electronic Hand (EMC) Medical Electrical Essential requirements for Safety Information Technology Equipment for Safety Additional internal and external test results and associated project documentation can be found in the Technical File RP609. 58 8747 FCC Warning Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. The RSLSteeper bebionic Medium Hand, Model:
RSL-RP609, complies with Part 18 of the FCC Rules
(Section 18.212). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. The End product must have a label stating Contains FCC ID:PBBGC350616 place on it inline with FCC labelling regulations. The FCC and IC information is located on the outside of the palm of each hand (left and right) underneath the gaitor. 59 INDUSTRY CANADA STATEMENTS This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (IC:ID : 10634A-RSLRFBB) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Name / Model 7488910245/Wurth Gain 1,0 Impedance 50 Ohm OEM Responsibilities The RSL-RP609 Module has been certified for integration into products only by OEM integrators under the following conditions:
The antenna(s) must be installed such that a minimum separation distance of 20cm 1. is maintained between the radiator (antenna) and all persons at all times. 2. other antenna or transmitter. The transmitter module must not be co-located or operating in conjunction with any As long as the two conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). 60 IMPORTANT NOTE:
In the event that these conditions can not be met (for certain configurations or co-location with another transmitter), then Industry Canada certification is no longer considered valid and the IC Certification Number can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product
(including the transmitter) and obtaining a separate Industry Canada authorization. End Product Labeling The RSL-RP609 Module is labeled with its own IC Certification Number. If the IC Certification Number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. In that case, the final end product must be labeled in a visible area with the following:
Contains Transmitter Module IC RSL-RP609 or Contains IC: RSL-RP609 The OEM of the RSL-RP609 Module must only use the approved antenna(s) listed above, which have been certified with this module. The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module or change RF related parameters in the users manual of the end product. The users manual for the end product must include the following information in a prominent location:
To comply with Industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times and must not be co-located or operating in conjunction with any other antenna or transmitter. 61 Radio Equipment - Canadian Warning Statements Radio Equipment - Canadian Warning Statements English
"Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication."
"This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device."
French
"Conformment la rglementation d'Industrie Canada, le prsent metteur radio peutfonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante."
"Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement."
To comply with industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20cm is maintained between the radiator
(antenna) and all persons at all times and must not be co-located or operating in conjunction with any other antenna or transmitter. 62 6.5 Warranty Warranty Terms Item Warranty Period Warranty Terms bebionic Hand Cables Wrist Batteries / Chargers Gloves 12 months 12 months 12 months 12 months 3 months Design and Manufacture Design and Manufacture Design and Manufacture Design and Manufacture, correct charging Design and Manufacture, not wear and tear An extended warranty is available for the bebionic hand, providing additional cover for year 2 or years 2+3. Hand Policy Hands returned to the RSLSteeper bebionic service centres will be assessed and where deemed beyond repair will be replaced where a claim is made under warranty, this claim must be supported by appropriate documentation. The warranty will be void on all system components if any components have been subject to abuse, repair or maintenance by an uncertified person, deliberate damage, loads beyond those for which the product was designed or by modification or neglect. You must state that you wish us to supply a replacement. Glove Policy Cosmetic gloves are only replaceable under warranty where the failure is due to a manufacturing fault as we have no control over the environment in which they are used. Please inspect the glove at first fitting to identify any faults so that we can provide a replacement where this is necessary. To identify the hand serial number, lift the gaiter on the back of the hand. The serial number can be found underneath. Please note: Each bebionic hand is fitted with a passive Radio Frequency Identity Device to allow identification and trace during manufacture and in case of return to our bebionic service centres. 6.6 Returns If bebionic components are to be returned for servicing please contact us at: bebionic@rslsteeper.com stating the hand serial number. We will issue a returns number and returns form that will need completeing in full so that your request can be dealt with promptly. Spare Parts Policy Some components of a bebionic system are replaceable by bebionic accredited practitioners. For further advice on any repairs please contact your bebionic distributor or email: enquiries@steeperusa.com. For both parts and service, please mention that the hand is a bebionic3 hand; including details as the whether it is Large or Medium, Left or Right and the date of purchase. 63 Notes 64 Notes 65 Notes 66 Installation Disc Please refer to page 36 for installtion instructions 67 www.bebionic.com be confident Technical Support Manufacturing Centre, Unit 7, Hunslet Trading Estate, Severn Road, Leeds, LS10 1BL, UK Tel: +44 (0) 113 270 4841 e: enquiries@rslsteeper.com Technical Support 3619 Paesanos Parkway, Shavano Center III, Suite 200, San Antonio, 78231 Texas. USA Tel: 210 481 4126 e: enquiries@steeperusa.com RSLLIT317 Issue 1 2012
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-11-20 | 2401 ~ 2482.5 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-11-20
|
||||
1 | Applicant's complete, legal business name |
RSLSteeper
|
||||
1 | FCC Registration Number (FRN) |
0021963095
|
||||
1 | Physical Address |
Unit 7 Products Division
|
||||
1 |
Leeds, LS10 1BL
|
|||||
1 |
United Kingdom
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
P******@tracglobal.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
PBB
|
||||
1 | Equipment Product Code |
GC350616
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T**** C********
|
||||
1 | Title |
Mr
|
||||
1 | Telephone Number |
00441********
|
||||
1 | Fax Number |
00448********
|
||||
1 |
t******@rslsteeper.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RF Module GC350616 | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Modular Approval | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Element Materials Technology Warwick Ltd
|
||||
1 | Name |
S****** B******
|
||||
1 | Telephone Number |
01695********
|
||||
1 | Fax Number |
01695********
|
||||
1 |
s******@element.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2401.00000000 | 2482.50000000 |