Eng Esp Deu Fra WRMB004x Installation Guide Gua de instalacin WRMB004x Installationsanleitung WRMB004x Guide d'installation WRMB004x Ned Sve Installatiehandleiding WRMB004x Installationsguide WRMB004x 83
[3-1/4"]
13,5
[1/2"]
WRMB004x 3 8
]
"
4
/
1
-
3
[
Eng Esp Deu Flush mounting Installation with WRMBL1 base Montaje de empotrar con la base WRMBL1 Unterputz Montage mit WRMBL1 Fra Ned Sve Montage encastr avec la base WRMBL1 Inbouw installatie met WRMBL1 Ytmontering av WRMBL1 Eng Esp Deu Fra Ned Sve GANG ELECTRICAL STANDARD BOX MODULO CAJA ELECTRICA ESTANDARD STANDARD SCHALTERDOSE PLOTS D'ENCASTREMENT STANDARD STANDAARD ELEKTRISCHE INBOUWDOOS STANDARD APPARATLDA R 6[1/4"]
Eng Esp Deu Fra Ned Sve FIXING FIJACIONES BEFESTIGUNG FIXATION FIXEERGATEN MONTAGE 52 60
[2-1/16"]
[2-3/8"]
/
]
"
4 1
-
3
[
3 8
/
]
"
8 3
-
2
[
0 6 60
[2-3/8"]
2 5 0 6
]
"
6 1 1
-
2
/
[
/
]
"
8 3
-
2
[
TORX 10 Eng Esp Deu Fra Ned Sve METAL PLATE PANEL METLICO METALLPLATTE PLAQUE EN MTAL METALEN PLAAT METALLPLT 60
[2-3/8"]
83
[3-1/4"]
7
[1/4"]
METAL NO METAL METAL // NO METAL Eng Esp Deu Flush mounting Installation with WRMFWAV Montaje de empotrar con el WRMFWAV Unterputz Montage mit WRMFWAV Fra Ned Sve Montage encastr avec le WRMFWAV Inbouw installatie met WRMFWAV Ytmontage av WRMFWAV WRMBxxx Eng Esp Deu Fra Ned Sve GANG ELECTRICAL STANDARD BOX MODULO CAJA ELECTRICA ESTANDARD STANDARD SCHALTERDOSE PLOTS D'ENCASTREMENT STANDARD STANDAARD ELEKTRISCHE INBOUWDOOS STANDARD APPARATLDA R 6[1/4"]
Eng Esp Deu Fra Ned Sve FIXING FIJACIONES BEFESTIGUNG FIXATION FIXEERGATEN MONTAGE 60
[2-3/8"]
52 60
[2-1/16"]
[2-3/8"]
Eng Esp Deu Fra Ned Sve METAL PLATE PANEL METLICO METALLPLATTE PLAQUE EN MTAL METALEN PLAAT METALLPLT
/
]
"
8 3
-
2
[
0 6 2 5 0 6
]
"
6 1
/
1
-
2
[
]
"
8
/
3
-
2
[
METAL METAL // NO METAL 2016 SALTO Systems S.L. 1/6 225064 -ED0 -08/08/2016 Eng Esp Deu Fra Ned Sve Included Incluido Inbegriffen Inclus Meegeleverd Inkluderad European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. Eng Esp Deu Fra WRMB004x Installation Guide Gua de instalacin WRMB004x Installationsanleitung WRMB004x Guide d'installation WRMB004x Ned Sve Installatiehandleiding WRMB004x Installationsguide WRMB004x Eng Esp Deu Surface mounting Installation with WRMBH1 base Instalacin de sobreponer con la base WRMBH1 Aufputz Montage mit WRMBH1 Fra Ned Sve Installation en Surface avec la base WRMBH1 Opbouw installatie met WRMBH1 Ytmontage av WRMBH1 Eng Esp Deu Fra Ned Sve FIXING FIJACIONES BEFESTIGUNG FIXATION FIXEERGATEN MONTAGE 60
[2-3/8"]
/
]
"
8 3
-
2
[
0 6
/
]
"
4 1
-
3
[
3 8 Eng Esp Deu Fra Ned Sve METAL PLATE PANEL METLICO METALLPLATTE PLAQUE EN MTAL METALEN PLAAT METALLPLT 60
[2-3/8"]
83
[3-1/4"]
0 6
/
]
"
8 3
-
2
[
20
[13/16"]
METAL NO METAL METAL // NO METAL Eng Esp Deu Surface mounting Installation with WRMFHAV Instalacin de sobreponer con el WRMFHAV Aufputz Montage mit WRMFHAV Fra Ned Sve Installation en Surface avec le WRMFHAV Opbouw installatie met WRMFHAV Ytmontage av WRMFHAV Eng Esp Deu Fra Ned Sve FIXING FIJACIONES BEFESTIGUNG FIXATION FIXEERGATEN MONTAGE 60
[2-3/8"]
WRMBxxx
/
]
"
8 3
-
2
[
0 6
/
]
"
4 1
-
3
[
3 8 Eng Esp Deu Fra Ned Sve METAL PLATE PANEL METLICO METALLPLATTE PLAQUE EN MTAL METALEN PLAAT METALLPLT 60
[2-3/8"]
83
[3-1/4"]
0 6
/
]
"
8 3
-
2
[
20
[13/16"]
METAL METAL // NO METAL 2016 SALTO Systems S.L. 2/6 225064 -ED0 -08/08/2016 Eng Esp Deu Fra Ned Sve Included Incluido Inbegriffen Inclus Meegeleverd Inkluderad European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. Eng Esp Deu Fra WRMB004x Installation Guide Gua de instalacin WRMB004x Installationsanleitung WRMB004x Guide d'installation WRMB004x Ned Sve Installatiehandleiding WRMB004x Installationsguide WRMB004x Eng Esp Deu Fra Ned Sve Installation example:
Ejemplo de instalacin:
Installationsbeispiel:
Exemple dinstallation:
Installatievoorbeeld:
Installationsexempel:
Model: CU42E0 Eng Fra Esp Deu Ned Sve Same pair Mme paire Mismo par Gleiches Paar Hetzelfde paar Samma par Eng Esp Deu Fra Ned Sve Only conect to CU42xx Solo conectar a CU42xx Nur fr Steuereinheit CU42xx Connecter uniquement CU42xx Alleen aansluiten op CU42xx Ansluts endast till CU42xx Eng Esp Fra B A
+V Cable connection Cableado Cblage Eng Green Yellow Black Red Esp Verde Amarillo Negro Rojo Deu Ned Sve Fra Vert Jaune Noir Rouge Verdrahtung Draadwerk Ledningar Deu Grn Gelb Schwarz Rot Ned Groen Geel Zwart Rood Sve Grn Gul Svart Rd ON Power Input: 12VDC-1A 12VDC Input GND 12VDC Output (1A) GND A B
+
-
TAMPER BUS485
+
-
+
-
+
-
+
-
+
-
+
-
IN1 IN2 IN3 IN4 IN5 IN6 Ethernet 10Base-T 100Base-TX READER 1 READER 2 RL1 RL2 RL3 RL4 B A
-
+
B A
-
+
NC C NO NC C NO NC C NO NC C NO Eng Esp Fra Deu Ned Sve 3MTM ScotchlokTM butt connector UY2 Crimp with cap side down Conector 3MTM ScotchlokTM butt UY2 Crimpar con la tapa hacia abajo Connecteur 3MTM ScotchlokTM butt UY2 Crper avec le capuchon vers le bas 3MTM ScotchlokTM butt Einzeladerverbinder UY2 Mit der Kappe nach unten zusammendrcken 3MTM ScotchlokTM draad connectors - UY2 Krimp/aanknijpen met het gekleurde deksel naar beneden 3MTM kontakt ScotchlokTM butt UY2 Monteras med platta sidan nert Installation example with RJ45:
Ejemplo de instalacin RJ45:
Innstallationsbeispiel fr RJ45:
Model: CU4200 Eng Esp Deu Fra Ned Sve Optional Opcional Optional Optionel Optioneel Valfritt Exemple dinstallation avec connecteur RJ45 :
Installatie voorbeeld RJ45:
Installationsexempel RJ45:
SP224861 SP224895 Eng Esp Deu Fra Ned Sve Optional Opcional Optional Optionel Optioneel Valfritt Power Input: 12VDC-1A 12VDC Input GND 12VDC Output (1A) GND A B
+
-
TAMPER BUS485
+
-
+
-
+
-
+
-
+
-
+
-
IN1 IN2 IN3 IN4 IN5 IN6 ON READER 1 READER 2 RL1 RL2 RL3 RL4 B A
-
+
B A
-
+
NC C NO NC C NO NC C NO NC C NO Eng Esp Deu Fra Red Rojo Rot Rouge Rood Rd Eng Esp Deu Fra Ned Ned Minimum distance between readers 50 cm Distancia mnima entre los lectores 50 cm Mindestabstand zwischen Lesern 50 cm La distance minimale entre les lecteurs doit tre de 50 cm De minimale afstand tussen de lezers moet 50 cm zijn Minsta avstnd mellan lsare 50 cm Sve Sve European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. Eng Esp Deu Fra Ned Sve Red Rojo Rot Rouge Rood Rd B A
-
+
2016 SALTO Systems S.L. 3/6 225064 -ED0 -08/08/2016 Installatiehandleiding WRMB004x Installationsguide WRMB004x Power Consumption Note 1 Max 66 85 Unit C
%
Reader Min Max 160 Unit mA Eng Esp Deu Fra WRMB004x Installation Guide Gua de instalacin WRMB004x Installationsanleitung WRMB004x Guide d'installation WRMB004x Ned Sve Eng Electrical characteristics:
Operation conditions Min
-35 35 Temperature Humidity RF characteristics RFID frequency Bluetooth Smart frequency Cen. 13.56 2.445 Min 2.4 Max 2.483 Unit Mhz Ghz Esp Caractersticas elctricas Condiciones ambientales Min
-35 35 Min
-35 35 Temperatura Humedad Caractersticas RF Frecuencia RFID Frecuencia Bluetooth Smart Max 66 85 Unit C
%
Cen. 13.56 2.445 Min 2.4 Max 2.483 Unit Mhz Ghz Deu Elektronische Eigenschaften:
Umgebungsbedingungen Temperatur Feuchtigkeit RF Frequenzen RFID Frequenz Bluetooth Smart Frequenz Max 66 85 Einheit C
%
Min 2.4 Mitte 13.56 2.445 Max 2.483 Einheit Mhz Ghz Fra Caractristique lectronique Condition de fonctionnement Min
-35 35 Temprature Humidit Caractristiques RF Frquence RFID Frquence Bluetooth Smart Cen. 13.56 2.445 Min 2.4 Max 66 85 Unit C
%
Max 2.483 Unit Mhz Ghz Ned Technische gegevens:
Note 1: Installer must take this data into account to dimension the CU42xx power supply Note 2: Not use with Scotchlok butt connector UY2 Consumo Nota 1 Lector Min Max 160 Unit mA Nota 1: El instalador ha de tener en cuenta la dimensin del alimentador de la CU42xx Nota 2: No usar el conector Scotchlok butt UY2 con este tipo de cable Stromaufnahme Note 1 Leser Min Max 160 Einheit mA Note 1: Bitte beachten Sie die Stromaufnahme bei der Planung des Netzteils fr die CU42XX Note 2: Nicht verwenden mit den Scotchlok Einzeladerverbinder UY2 Consommation Note 1 Lecteur Min Max 160 Unit mA Note 1: l'installateur doit calculer l'alimentation ncessaire pour alimenter la CU42xx . Note 2: Ne pas utiliser le connecteur Scotchlok UY2 avec ce type de cble Omgeving Temperatuur Vochtigheid RF karakteristieken RFID frequency Bluetooth Smart frequency Sve Teknisk data:
Arbetsomrde Temperatur Fukt RF data RFID Frekvents Bluetooth Smart Frekvents Min
-35 35 Min 2.4 Min
-35 35 Min 2.4 European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. Max 66 85 Unit C
%
Max 2.483 Unit Mhz Ghz Cen. 13.56 2.445 Voeding in opm 1 Wandlezer Min Max 160 Unit mA Opm 1: Installateur moet deze info meenemen voor de berekening van de voeding voor de CU42xx Opm. 2: 3M Scotchlok 2-voudig draad connectors NIET GEBRUIKEN !!!
Strmkonsumtion Not 1 Lsare Min Max 160 Enhet mA Not 1: Installatr mste ta med denna information fr att berkna strmtgng Not. 2: Ej med Scotchlock butt UY2 kontakt Max 66 85 Enhet C
%
Max 2.483 Enhet Mhz Ghz Cen. 13.56 2.445 2016 SALTO Systems S.L. 4/6 225064 -ED0 -08/08/2016 Cable type and max. distances Cable type Reader UTP Cat5e 2 pairs AWG24 UTP Cat5e 4 pairs
+ SP224861/SP224895 Twisted pairs AWG18 Note2 250m 400m 100m Tipo de cable y distancias max. Tipo de cable Lector UTP Cat5e 2 pares AWG24 UTP Cat5e 4 pares
+ SP224861/SP224895 Pares trenzados AWG18 Nota 2 100m 250m 400m Verkabelung und max. Entfernungen Kabeltyp Leser UTP Cat5e 2 Paar AWG24 UTP Cat5e 4 Paar
+ SP224861/SP224895 Twisted-pairs AWG18 Note 2 100m 250m 400m Type de cble Type de cble Lecteur UTP Cat5e 2 paires AWG24 UTP Cat5e 4 paires
+ SP224861/SP224895 Paire torsades AWG18 Note2 100m 250m 400m Kabeltype en max. afstand Kabeltype Wandlezer UTP Cat5e 2 paar AWG24 UTP Cat5e 4 paar
+ SP224861/SP224895 Twisted pair AWG18 opm 2 100m 250m 400m Kabeltyper och max avstnd Kabel Lsare UTP Cat5e 2 par AWG24 UTP Cat5e 4 par
+ SP224861/SP224895 Partvinnad AWG18 Not 2 100m 250m 400m Eng Esp Deu Fra WRMB004x Installation Guide Gua de instalacin WRMB004x Installationsanleitung WRMB004x Guide d'installation WRMB004x Ned Sve Installatiehandleiding WRMB004x Installationsguide WRMB004x Eng Esp SIGNALLING Signal Card Rejection Privacy or emergency status Standard opening Standard locking Open plus oce CLR Button Reset Light Red Red 5x(50/50x3+o300) Green Red Green 400/200 Orange Orange 50/100 Time
(sec) 1 3 1 0,5 2,4 Cont. 450 msg SEALECTICA Seal Rechazo de Tarjeta Rechazo por Privacidad o Emergencia Apertura Normal Cierre Normal Abrir y Paso Botn CLR (3) Reset Tiempo Luz Rojo Rojo 5x(50/50x3+ apagado 300) Verde Rojo Verde 400/200 Rojo + Verde Rojo + Verde 50/100
(seg) 1 3 1 0,5 2,4 Cont. 450 msg Buzzer High pitched 50/50 High pitched 5x(50/50x3 + o 300) Low pitched Low pitched High pitched/Low pitched 400/200 High pitched Low pitched 50/100 Time
(sec) 1 3 0,3 0,2 2,4 Cont. 450 msg Buzzer Agudo 50/50 Agudo 5x(50/50x3 + apagado 300) Medio Grave Agudo/Grave 400/200 Agudo Medio 50/100 Tiempo
(seg) 1 3 0,3 0,2 2,4 Cont. 450 msg Deu SIGNALE Signal Karte abgelehnt Bitte-nicht-stren oder Notschlieung Normale Trnung Verschluss der Tr Oce-Mode aktiviert CLR Taste gedrckt Reset Fra SIGNALISATION Signal Carte rejete Privacit ou tat durgence Ouverture Standard Verrouillage Standard Ouverture passage libre Bouton CLR Reset Ned SIGNALERING Signaal Geen rechten Privacy- of noodsluiting Standaard opening Standaard sluiting Open plus loopstand CLR knop Reset Sve SIGNALERING Hndelse Nekat tilltrde Str ej eller Ndlge Standard ppning Standard stngning ppning med kontorsfunktion CLR Knapp Nollstllning European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. LED Rot Rot 5x(50/50x3+ aus300) Grn Rot Grn 400/200 Rot + Grn Rot + Grn 50/100 Zeit
(Sek) 1 3 1 0,5 2,4 Kont. 450 Buzzer Hoher Ton 50/50 Hoher Ton 5x(50/50x3 + aus 300) Tiefer Ton Tiefer Ton Hoher Ton /Grave 400/200 Hoher Ton Tiefer Ton 50/100 Temps Voyant Rouge Rouge 5x(50/50x3+ o300) Vert Rouge Vert 400/200 Rouge + Vert Rouge + Vert 50/100
(sec) 1 3 1 0,5 2,4 Cont. 450 msg Buzzer Aigu 50/50 Aigu 5x(50/50x3 + o 300) Grave Grave Aigu/Grave 400/200 Aigu Grave 50/100 Zeit
(Sek) 1 3 0,3 0,2 2,4 Kont. 450 Temps
(sec) 1 3 0,3 0,2 2,4 Cont. 450 msg LED indicatie Rood Rood 5x(50/50x3+ o 300) Groen Rood Groen 400/200 Rood + Groen Rood + Groen 50/100 Ljussignal Rd Rd 5x(50/50x3+ av 300) Grn Rd Grn 400/200 Rd + Grn Rd + Grn 50/100 Time
(sec) 1 3 1 0,5 2,4 Cont. 450 msg Tid
(sek) 1 3 1 0,5 2,4 Konst. 450 ms Geluid Hoge tonen 50/50 Hoge tonen 5x(50/50x3 + o 300) Lage tonen Lage tonen Hoge tonen /Grave 400/200 Hoge tonen Lage tonen 50/100 Summer Hg ton 50/50 Hg ton 5x(50/50x3 + av 300) Lg ton Lg ton Hg ton 400/200 Hg ton Lg ton 50/100 Time
(sec) 1 3 0,3 0,2 2,4 Cont. 450 ms Tid
(sek) 1 3 0,3 0,2 2,4 Konst. 450 ms 2016 SALTO Systems S.L. 5/6 225064 -ED0 -08/08/2016 European view All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. 2016 SALTO Systems S.L. 6/6 225064 -ED0 -08/08/2016