EPNA Ed. 01 Smart MBS RRH-C2 Installation Manual
: 3 105 3 Document Center 442-600
:http://www.samsungdocs.co.kr Call Center .
:1588-4141 2011 SAMSUNG Electronics Co., Ltd. All rights reserved. Smart MBS RRH-P4 Revision History Edition 00 01 Date 2011. 05. 2011. 09. 04 Initial Draft Update Desciption Warning Changes or modifications not expressly approved by Samsung could void the user's authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. instruction manual, may cause harmful interference the to SAMSUNG Electronics Co., Ltd. I Smart MBS RRH-P4 Table of contents 2.2.1 Revision History ___________________________________________________________________ I 1. Before Installation________________________________________________1 1.1 System Outlook ________________________________________________________1 1.2 Cable Connection_______________________________________________________7 2. Installation_____________________________________________________A-1 2.1 System Installation Process ____________________________________________A-1 2.2 RRH Installation ______________________________________________________A-3 Installation Diagram ______________________________________________________A-3 2.4 Mounting ____________________________________________________________A-5 2.4.1 Wall Mount Type_________________________________________________________A-5 Pole Mount Type_________________________________________________________A-7 2.4.2 2.5 RRH ~ Antenna Cable Connection ______________________________________A-9 Feeder Line Connection __________________________________________________A-9 RET Cable Connection _________________________________________________ A-15 2.6 Frame Ground Cable Connection_______________________________________A-18 RRH-C2 Grounding ____________________________________________________ A-18 2.7 Connecting DC and CPRI Cable _________________________________________A-20 RRH-C2 Power Cable Connection________________________________________ A-20 RRH-C2 CPRI Cable Connection ________________________________________ A-27 F.1 Standard Torque for Bolt______________________________________________A-32 2.7.1 2.7.4 2.5.1 2.5.2 2.6.1 SAMSUNG Electronics Co., Ltd. II Smart MBS RRH-P4 1. Before Installation 1.1 System Outlook RRH-C2 Fig1.1RRH-C2 Outlook SAMSUNG Electronics Co., Ltd. 1 1 . Error! Style not defined. RRH-C2 External Interface Fig1.2RRH-C2 External Interface 2 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 Capacity This is the specification of RRH-C2. Items Air specification Operating Frequency Channel Bandwidth Capacity RF Power per Sector DU~RRH-C2 Interface Holdover Specification FDD CDMA DL: 862~ 869 MHz UL: 817 ~ 824 MHz 1.25MHz/5MHz 1.25 MHz CDMA 5Carriers 50 W 2 T CPRI 4.0(Optic) 24 hr Input Voltage This is the input voltage specification of RRH-C2. RRH-C2comply with UL60950 safety regulations. Items Input Power Power consumption(MAX) Specification
-48VDC 10.4A (at -48V with 47dBm output power on each ANT) 19.0 A (at -38V with 48.5dBm output power on each ANT) Size and Weight Size(mm) Weight(kg) RRH-C2 RRH-C2 471(W) 269(D) 457(H) Max 31 kg Specification SAMSUNG Electronics Co., Ltd. 3 1 . Error! Style not defined. Environment condition Items Temperature Humidity Criteria
-40~55C (without solar load) 10~95%
Altitude Earthquake
-60~1,800 m(-197~6,000 ft) Zone 4 Vibration Office Vibration Transportation Vibration
(sound Noise pressure level) EMI With 1.5 m(5 ft) distance, 1.0 m(3 ft) Height
<65 dBA Comply with specification Specification GR-487-CORE Sec. 3.26 GR-487-CORE Sec.3.34.2
(Issue 2, April, 2002) R3-204 GR-63-CORE Sec.4.1.3 GR-63-CORE Sec.4.4.1 GR-487-CORE Sec.3.35.6 GR-63-CORE Sec.4.4.4 GR-487-CORE Sec.3.35.5 GR-63-CORE Sec.4.4.5 GR-487-CORE Sec.3.35.3 GR-487-CORE Sec.3.29 FCC Title47 Part 15 Class B GR-1089-CORE EN 55022, EN 55024 EN 301 489 4 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 1.2 Cable Connection
[Rectifier]
[UADU]
[RF Antenna]
l e b a C l e b a C r e w o P
) 4 l e b a C d n u o r G 2 C H R R
) 3
[MGB]
I R P C
) 5 6) RET Cable 7) RF Cable l e b a C d n u o r G e n L i r e d e e F
) e n L i r e d e e F
. n i
8 7 r e v o h t i w
t i K d n u o r G
1) MGB Ground Cable
[TGB]
2) TGB Ground Cable TGB and Ground Kit is required when over 7/8 in. Feeder Line is used. Fig1.3Cabling Diagram SAMSUNG Electronics Co., Ltd. 5 1 . Error! Style not defined. 1.1RRH-C2Connecting Cable From Frame Grounding To MGB
(Main Ground Bar) Cable 2) MGB Ground Cable
: AWG4/0, GV 95 mm21C TGB 2) TGB Ground Cable
(Tower Ground Bar)
: AWG4/0, GV 95 mm21C MGB Rectifier UADU RET Antenna 3) RRH-C2 Ground Cable
: AWG8, GV 6 mm21C 4) Power Cable
: AWG10, 4 mm22C-1 5) CPRI Cable
: Optic Cable(Single Mode) 6) RET Cable Assy 7) RF Cable (1/2 in. or 7/8 in. Feeder Line)
,./RRH-C2 6 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 2. Installation 2.1 System Installation Process RRU Grounding Cabling the Hybrid Cable Cabling in the Cabinet Cabling in the RRU Check Fig2.1RRH and Cabling process
Note 1. Equipment intended for installation in Restricted Access Location 2. Installation shall be in accordance with the applicable parts of Chapter 8 of ANSI/NFPA 70 SAMSUNG Electronics Co., Ltd. A-1 F. Error! Style not defined. 2.2 RRH Installation 2.2.1 Installation Diagram Fig2.2RRH-C2Installed Diagram(Pole type) Fig2.2 RRH-C2Installed Diagram (Wall Mount type) A-2 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.4 Mounting 2.4.1 Wall Mount Type This explains how to install RRH-C2 to the wall. 1) Assemble bracket to RRH-C2(A) 2) Assemble the wall mount assy to the wall. (B) 3) Install RRH-C2 to Wall mount assy(C)
Fig2.3Wall Mounting (1) Fig2.4WallMounting (2)Wall mount Assy SAMSUNG Electronics Co., Ltd. A-3 F. Error! Style not defined. 2.4.2 PoleMount Type This explains how to install RRH-C2 to the pole 1) Assemble bracket to RRH-C2 (A) 2) Assemble the pole mount assy to the pole. (B) 3) Install RRH-C2 to the pole mount assy(C) Fig2.6Pole Mounting (1) Fig2.7PoleMounting (2) pole mount assy A-4 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.5 RRH ~ Antenna Cable Connection 2.5.1 Feeder Line Connection This explains how to connect cable between RRH-C2 and Antenna. RF Antenna B RRH-
A Fig2.9RRH-C2Feeder Line SAMSUNG Electronics Co., Ltd. A-5 F. Error! Style not defined. 1) RRH-C2 RF port RF antenna 1/2 in. feeder line . 2) 1/2 in. feeder line het shrink tube(jelly type) Din-male RRH-C2 RF port RF antenna port . 3) , heat shrink tube(jelly type) . Fig2.10RRH-C2Feeder Line Connection 1) A-6 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 RF Antenna Detail B Antenna Connector(Din-Female) Din-Type Male Connector for 1/2 In. Feeder Line Heat Shrink Tube(Jelly Type) 1/2in. Feeder Line Fig2.11RRH-C2Feeder Line Connection 2) SAMSUNG Electronics Co., Ltd. A-7 F. Error! Style not defined. RF
, pole down Fig .
- : / 45 45 45 RF Antenna A-8 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.5.2 RET Cable Connection tilting RET(Remote Electrical Tilting)
. RETConnector(SAMWOO, SU-20SP-8P) Heat Shrink Tube(Jelly Type, Black) RET Cable Fig2.12RETCable Connection SAMSUNG Electronics Co., Ltd. A-9 F. Error! Style not defined. RET Fig2.13RETCable Connector 2.3RETCable Connector Pin Map Pin Samwoo, SU-20SP-8P Function 1 3 5 6 7 1, 2, 8
+12V (max 10W power consumption) RS485B RS485A
+24 V (max 10W power consumption)
+24 V RTN NC 2.5.2 Optic Switch Connection This port will not be used for this project. A-10 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.6 Frame Ground Cable Connection 2.6.1 RRH-C2Grounding RRH-C2 . 1) (AWG8, GV 6 1 C) 1 MGB RRH-C2
. 2) 6 heat shrink tube . 3) RRH-C2 , M6 SEMS . 6 Pressure Terminal
(d2: 16 mm, 90, 2 Hole) Detail A Heat Shrink Tube(Green) M6 x 12L SEMS Ground Cable(AWG8, GV 6 mm21C) From MGB(Main Ground Bar) Fig2.14RRH-C2Frame Ground Cable Connection SAMSUNG Electronics Co., Ltd. A-11 F. Error! Style not defined. UL ,
. Ex) Manufacture-Panduit RRH-C2 : 6 mm2 Type Name(LCD8-14AF-L)
. Inspection Window
. A-12 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.7 Connecting DC and CPRI Cable 2.7.1 RRH-C2Power Cable Connection RRH-C2 . 1) RRH-C2 power window cover screw Torx(T15) open .
(Cover screw cover .) Optic0 Fig2.23RRH-C2Power Cable Connection (1) SAMSUNG Electronics Co., Ltd. A-13 F. Error! Style not defined. 3) BasebandRack DC SPD Terminal (Hybrid cable, AWG8 or AWG10,2C)1 RRH-C2 . 4) 70 mm 10mm . 5) . DC Power Cable
(AWG8 or AWG10, 11.5~15.5mm) 11.5 ~
15.5mm 70 mm 10 mm 60 mm 70 mm DC Power Cable
(AWG8 or AWG10, 11.5~15.5mm) DC Power Cable
(AWG8 or AWG10, 11.5~15.5mm) Fig2.25RRH-C2Power Cable Connection (2) A-14 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 6) cable gland nut . 7) (Hybrid cable, AWG8 or AWG10, 2C) 1 cable gland nut . 8) power window
. power cable
. 9) Power terminal block screw
, screw . 10) Cable gland nut . DC Power Cable
(AWG8 or AWG10, 11.5~15.5mm) Cable Gland Nut Fig2.27RRH-C2Power Cable Connection (3) 11) , power window cover open
. SAMSUNG Electronics Co., Ltd. A-15 F. Error! Style not defined. Circuit Breaker Installation Required to connect to the circuit breaker for DC cable between BTS and RRH to support stable DC supply to RRH. -48VDC circuit breaker capacity is 32A for each connection. A-16 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 2.7.4 RRH-C2 CPRI Cable Connection RRH-C2 UADU interface CPRI . 1) RRH-C2 optic window screw Torx(T15) open .
(Cover screw cover .) 2) optic cable gland nut . 3) Optic cable gland nut, . 4)Optic (5core, 1 ) optic optic window optic connector SFP module .
(optic bending radius R=20mm
, .) 5) Optic connector optic cable 10mm gland cablegland nut . 6) CPRI , window cover screw . Optic0 2.28RRH-C2CPRI Cable Connection (1) SAMSUNG Electronics Co., Ltd. A-17 F. Error! Style not defined. 2.5CPRI Cable Cable Color Port Blue Optic 0 Orange Optic 1
(CDMA 0) Green Spare Brown Spare Gray Spare A-18 SAMSUNG Electronics Co., Ltd. Smart MBS RRH-P4 /Ed.00 A. Standard Torque F.1 Standard Torque for Bolt
(, , .) F.1 Torque[kgf.cm]
M3 M4 M5 M6 M8 M10 M12 4.59~5.61 10.98~13.42 21.15~15.85 38.16~46.64 91.8~112.2 180~220 307.8~376.2 Torque[N.m]
0.45~0.55 1.08~1.32 2.07~2.54 3.74~4.58 9.01~11.01 17.66~21.58 30.20~36.91 SAMSUNG Electronics Co., Ltd. A-19 F. Error! Style not defined. B. Product Label
B-20 SAMSUNG Electronics Co., Ltd. RRH-C2 2011 Samsung Electronics Co., Ltd. All rights reserved.