Product Information and Regulatory Statement Important Safety Information - Read First!
Before installing, configuring, or operating any equipment, all relevant technical documentation must be read, understood, and followed. Savant technical documentation may contain important product-specific installation, mounting, and safety instructions, and can be accessed through the Savant Store. Scan the QR code or visit the URL below, enter the relevant product name or SKU in the Search Savant prompt, and select the product purchased to find documents, specifications and more. https://store.savant.com/DefaultStore/ccrz__HomePage Safety Statements Dclarations de Scurit All safety instructions below must be read, understood, and carefully followed under all applicable circumstances when working with any Savant equipment. Toutes les instructions de scurit ci-dessous doivent tre lues, comprises et soigneusement suivies dans toutes les circonstances applicables lorsque vous travaillez avec un quipement Savant. 1. Follow all input power ratings marked on product near power 1. Suivez toutes les puissances nominales indiques sur le input!
2. If fuse replacement is required, replacement fuse should match fuse rating marked on the product. 3. Do not use equipment near water. 4. Clean only with dry cloth. 5. Do not block any ventilation openings or install near any heat sources such as heat registers, stoves, radiators, amplifiers, etc. 6. Refer all servicing to qualified service personnel. Servicing is required when any part of the apparatus has been damaged in any way, or fails to operate normally for any reason. 7. Use only attachments/accessories specified by the manufacturer, following all relevant safety precautions for any such attachments/accessories. 8. For applicable equipment, use the included power cord with the grounding prong intact to insure proper grounding of the device. 9. If the provided plug does not fit the desired outlet, contact a licensed electrician to replace the obsolete outlet. 10. Protect any power cord from being walked on, pinched, strained, or otherwise potentially damaged, especially at the outlet or device connections. 11. Disconnect any outlet powered apparatus from its power source during lightning storms or when unused for long periods of time. 12. To completely disconnect equipment from AC mains power, disconnect the power supply cord plug from the AC receptacle on the device. 13. For any hardwired or fixed in-wall apparatus, carefully follow all wiring diagrams and instructions. All electrical wiring and servicing should be performed by a properly licensed electrician. produit prs de la puissance absorbe!
2. Si le remplacement du fusible est ncessaire, le fusible de remplacement doit correspondre la valeur nominale du fusible indique sur le produit. 3. Nutilisez pas dquipement prs de leau. 4. Nettoyer uniquement avec un chiffon sec. 5. Ne bloquez pas les ouvertures de ventilation et ninstallez pas proximit de sources de chaleur telles que les registres de chaleur, les cuisinires, les radiateurs, les amplificateurs, etc. 6. Confiez toutes les rparations un technicien qualifi. Un entretien est requis lorsquune partie de lappareil a t endommage de quelque manire que ce soit ou ne fonctionne pas normalement pour une raison quelconque. 7. Utilisez uniquement les attachements / accessoires spcifis par le fabricant, en suivant toutes les prcautions de scurit applicables ces attachements / accessoires. 8. Pour lquipement applicable, utilisez le cordon dalimentation inclus avec la broche de mise la terre intacte pour assurer une mise la terre correcte de lappareil. 9. Si la fiche fournie ne correspond pas la prise souhaite, contactez un lectricien agr pour remplacer la prise obsolte. 10. Protgez tout cordon dalimentation contre les pitinements, les pincements, les tensions ou autres dommages potentiels, en particulier au niveau de la prise ou des connexions de lappareil. 11. Dbranchez tout appareil aliment par une prise de courant de sa source dalimentation pendant les orages ou lorsquil nest pas utilis pendant de longues priodes. 12. Pour dconnecter compltement lquipement du secteur, dbranchez la fiche du cordon dalimentation de la prise secteur de lappareil. 13. Pour tout appareil encastr ou cbl, suivez attentivement tous les schmas de cblage et les instructions. Tout le cblage lectrique et lentretien doivent tre effectus par un lectricien dment agr. IMPORTANT NOTES:
For product mounting, installation, safety instructions, technical specifications, and more, refer to the product Quick Reference Guide, available via the link or QR code noted above. For regulatory and compliance information, see reverse of this sheet and/or product packaging. 1 of 2 45 Perseverance Way, Hyannis, MA 02601 Savant.com | 508.683.2500 Savant Product Regulatory Statement | 009-1950-01 200707 | 2020 Savant Systems, Inc. FCC Regulations This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for CLASS B digital devices, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correcting the interference with one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect this equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement - Wireless and Handheld Devices Only This device meets the governments requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are conducted using standard operating procedure accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. FCC and IC Identifier - Devices with Integrated Screen or User Interface Only This device electronically displays the FCC declaration of conformity logo as well as the FCC and IC identifier. This information can be found on the device by accessing:
(Service menu) > About (A propos de) IC Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios. The Country Code Selection feature is disabled for products marketed in the US/Canada. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
2. Cet appareil accepter toute interfrence, y compris les interfrences pouvant provoquer fonctionnement indsirable dappareil. Dclaration IC 1. Lappareil ne doit pas produire de brouillage, et Dclaration dexposition aux radiations Cet quipement est conforme aux limites dexposition aux radiations de la FCC dfinies pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20 cm entre le radiateur et votre corps. Identificateur de la FCC et dLc
(Menu de service) > About (A propos de) Ce priphrique par voie lectronique affiche le logo de dclaration de conformit FCC ainsi que lidentificateur de la FCC et dIC. Cette information peut tre trouve sur le terminal en accdant :
2 of 2 45 Perseverance Way, Hyannis, MA 02601 Savant.com | 508.683.2500 Savant Product Regulatory Statement | 009-1950-01 200707 | 2020 Savant Systems, Inc. A B F A B D E F G Dual 20 Amp Relay Companion Module (120V AC) Quick Reference and Installation Guide Box Contents
(1) Dual 20 Amp Relay Companion Module GPM-QP2R20120-21 QO w/Plug-on Neutral -or-
GPM-Q2R20120-21 QO w/Pigtail
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document) Descriptions D O N OT PRESS O N SCREEN REM OVE AFTER INSTALLATIO N CIRCUIT PO W ER B A PAIR C 12 0 V 2 0 A D U A L R E L A Y IN D O O R U S E O N LY 12 0 V A C 2 0 A /1H P M A X\C H A N 12 0 V A C 6 0 H z 12 0 V A C 6 0 H z G P M -Q P 2 R 2 012 0-21 M O D U L E IN P U T:
H O M E A U T O M A TIO N E Q UIP L O A D IN P U T:
#12-8 A W G C u O N LY L O A D O U T P U T:
IC ID: 10 79 8 A-Q P 2 R 2 012 0 F C C ID: P U U-Q P 2 R 2 012 0 E 523 6 0 9 IN P U T B IN P U T A W Y Y W O U T P U T B O U T P U T A E Specifications Environmental Humidity Location Module
(QO) Shipping Power Temperature 32 to 104 F (0 to 40 C) 5% to 85% Relative Humidity (non-condensing) Indoor Use Only Dimensions and Weights D G Height Width Depth 1.45 in.
(3.68 cm) 1.71 in.
(4.34 cm) 4.97 in.
(12.63 cm) 7.50 in.
(19.05 cm) 2.60 in.
(6.61 cm) 4.30 in.
(10.92 cm) Weight
.5 lbs
(.23 kg) 1.0 lbs.
(.45 kg) Input Power
(powers the module) Input Power
(from feeder breaker) Load Power 120V AC (+/- 10%) @ 60 Hz, 0.1A (max) 120V AC per input - 20A (max) 2400VA each
(20A resistive load / 1 HP max per channel) Features of Automatic Action Type 1.B action Standards Wireless Regulatory Bluetooth 5 Low Energy (BLE) 2.4 GHz radio frequency IEEE 802.15.4 Safety and Emissions FCC Part 15 UL ICES 003 Contains FCC ID:
PUU-QP2R20120 Contains IC:
10798A-QP2R20120 RoHS Compliant Recommended Load Center Types All QO compatible modules fit into inch load centers. Supported Load Types Standard Configuration Relay On/Off type loads (home automation) Electrical and Safety Characteristics Screw Tighten Torque 3.0 Nm Wire Type Copper (Cu) only Pollution Degree 2 Multi-Page LCD screen that can display the following:
Power draw and energy usage at each output. Firmware, Mac Address, and Regulatory Info. UID of the Host that the module is communicating with. Real-time Bluetooth status connectivity icon. Manual Load Switches - Toggle to the ON position to switch the load on. Toggle to AUTO for normal operation. Switch A controls output A, Switch B controls output B. PAIR Button - The PAIR button is a multi-use button. The duration that the button is pressed and held determines the function that gets initiated:
C Press and Release - Cycles through the screens available on the LCD (POWER > ENERGY > INFO 1 > INFO 2). Press and hold - Press and hold for 2 second to put the module into pairing mode. Press and hold for 5 seconds to reset. Input Power Connections - Connect the outputs from two breakers to inputs A and B on the companion module. Each input on the companion module should be connected to a single breaker. See the Wiring section below. Output Power Connections - Connect output A and output B to separate loads. See the Wiring section below. 120V AC Connection - Plugs into the 120V AC bus bar in the breaker panel. The voltage on this connection powers the companion module. Neutral - The model number of the module determines the type of neutral connection on the module:
Plug-On Neutral - Positioned on the bottom of the module is a neutral clip that plugs directly onto the neutral bar. Pigtail Neutral - A neutral wire protrudes from the modules rear and gets wired to the neutral bar in the breaker panel. Features Control capability for loads up to 2400VA per channel. All QO style relay modules are compatible with Schneider/Electric Purpose of Control Operating Control, Smart Relay Control Module or equivalent Square D QO load centers. Dynamic management of loads. Software Impulse Voltage Class A 2500V Construction of Control Open Type Supported Software Independently mounted for flush mounting Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec sample time. Communicates with the Panel Bridge Controller device using Bluetooth Low Energy (BLE) technology. Manual load switches, available on the front panel, can toggle power to the outputs On and Off. Savant OS da Vinci 10.x Color LCD display for easy identification and load status. Dual 20 Amp Relay Companion Module - QRG | 009-2113-00 Copyright 2021 Savant Systems, Inc | 211230 1 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Preliminary Important Information The breaker(s) feeding the companion module should not be larger than 20 amps. Each relay output can switch up to 20 amps. needed for the companion module. Each circuit breaker requires one space. Each companion module requires two spaces. To determine the number breaker panel spaces needed, add the number of spaces required for the circuit breaker(s) to the number of spaces A Panel Bridge Controller can communicate with up to 40 companion modules. Savant recommends not connecting any mission-critical loads such as medical devices to this relay companion module. ELECTRIC SHOCK! The 120V AC, 60 Hz source poses an electrical shock hazard that has the potential to cause serious injury to installers and end users. Branch Circuit Minimum Size of Conductors
(General circuit wiring, Copper Conductors) CAUTION! Risk of Electric Shock - More than one disconnect switch may be required to de-energize the device before servicing IMPORTANT! A licensed electrician is required to install any of Savants Relay Companion Modules. 15A 20A 30A 40A 50A 60A
#14 AWG #12 AWG #10 AWG #8 AWG
#6 AWG
#4 AWG NOTE: This wiring requirement was based on the National Electric Code
(NEC) (ANSI/NFPA70), Canadian Electric Code, Part 1 (CEC), and local codes Minimum Size of Conductors. Installation into Breaker Panel 1. Remove power from the breaker panel by switching off the panels main breaker. bars. 3. Install a second breaker alongside the first. 2. Position and install a circuit breaker into one of the slots in the panel. Press firmly until the breaker is fully seated onto the appropriate bus 4. Position and install the Companion Relay Module into the slot where it will be installed. Press firmly until the module is fully seated onto the appropriate bus bars. This companion module is typically installed alongside the breakers installed in steps 2 and 3. HELPFUL! A companion relay module fills two slots in the breaker panel but connects to only one phase (120V AC). See the diagram below. 5. Refer to the Wiring section below and make the appropriate connections. Wiring Use the diagram below when making connections between the companion module, associated breakers, and load(s). Additional wiring diagrams are available in the Savant Panelized Lighting Deployment Guide available on the Savant Community. When connecting an ARC fault type breaker, connect the neutral wire from the load to the neutral screw. Connect the neutral wire to the neutral bar when breaker is not a plug-on type neutral. Use AFCI / GFCI protection where required by local regulations Load 1 Load 2 Neutral Bar Neutral Bar Load 1 Load 2 BREAKER BREAKER A B A B I N P U T O U T P U T I N P U T O U T P U T 2 0 A D U A L R E L A Y A B A U T O O N I I C R C U T P O W E R P A R I BREAKER BREAKER I R A P R E W O P T U C R C I I N O O T U A B A Y A L E R L A U D A 0 2 T U P T U O T U P N I T U P T U O T U P N I B A B A ARC FAULT CIRCUIT STANDARD CIRCUIT Gnd Bar Gnd Bar plug-on neutral bars
(only when equipped) Breaker Panel Connect the neutral wire from the companion module to the neutral bar when not a plug-on neutral. Connect the neutral wire from the companion module to the neutral bar when not a plug-on neutral. Dual 20 Amp Relay Companion Module - QRG | 009-2113-00 Copyright 2021 Savant Systems, Inc | 211230 2 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Preliminary Use the instructions below to test the relay companion modules. The setup requires:
Circuit Test Instructions 20 Amp Dual Relay Companion Module.
(2) loads (20 amps max for each).
(2) 20 amp circuit breakers. 120V AC source IMPORTANT!
Breaker test panel. The type of companion module determines the type of breaker panel (plug-on neutral or not). When making connections, observe all general electrical best practices including local wire sizing guidelines. The GPM-QP2R20120-21 and GPM-Q2R20120-21 Companion Modules can accept up to a #12 AWG wire. See the Branch Circuit Minimum Size of Conductors table on the previous page for wire sizing information. 1. Plug the two 20 amp feeder circuit breakers and one 20 amp Dual Relay Companion Module into the circuit breaker test panel. 2. Connect the output from one of the circuit breakers to Input A on the companion module. 3. Connect the output from the remaining circuit breaker to Input B on the companion module. 4. Connect a load to Output A. 5. Connect a second load to Output B. 6. Connect the unused side of each load to the neutral bus bar in the breaker panel. 7. On companion modules that contain a neutral wire, connect the neutral wire to the neutral bar. 8. Apply power to the breaker panel (not shown in diagram). 1 9. Toggle the 20 amp feeder breakers to On. 10. To test, toggle the CIRCUIT POWER switches A and B to ON and verify both loads switch On. 11. Toggle the CIRCUIT POWER switches to AUTO and verify the loads switch Off 6 7 5 4 2 3 Load Load 10 11 120VAC I R A P R E W O P T U C R C I I N O O T U A B A Y A L E R L A U D A 0 2 T U P T U O T U P N I B A B A T U P T U O T U P N I PANEL CIRCUIT BREAKER PANEL CIRCUIT BREAKER 9 Plug-on neutral bus bar for modules with a Plug-On neutral clip Additional Documentation Further information is available in the documents listed below and can be accessed via the Savant Customer Community. Panel Bridge Controller with PoE (PBC-P1000) QRG Savant Panelized Lighting Deployment Guide Dual 20 Amp Relay Companion Module - QRG | 009-2113-00 Copyright 2021 Savant Systems, Inc | 211230 3 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Preliminary NOTES Dual 20 Amp Relay Companion Module - QRG | 009-2113-00 Copyright 2021 Savant Systems, Inc | 211230 4 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Preliminary