Instruction Manual G5 CU R Document Revision 66063 A Language English Document type Instruction Manual 66063 Document number Rev A Page 2 of 8 Document information Information Instruction Manual SCANRECO G5 CU R 66063 English 2013-05-20 English 2013-05-20 SCANRECO SCANRECO AB, SWEDEN Attribute Document Type Title Document No. Language Release date Original Release date (original) Author Company All rights reserved Design, equipment, technical data and specifications are subject to change or improvement without prior notice. The text in this instruction manual, or any part of it may not be reproduced or transmitted in any form or by any means, including electronic, mechanical, photocopying, recording, storage in an information retrieval system, or otherwise, without prior written permis-
sion of SCANRECO AB, SWEDEN. Revision history Revision A Date 2013-05-20 Note First release Document type Instruction Manual 66063 Document number Rev A Page 3 of 8 G5 receiver Product description The Central Unit (CU) is manufactured in robust plastic housing and provides contacts for the connection of power supply and electro-hydraulic valves. Several of the outputs can also be used as digital inputs. Depending on the version of the G5 Central unit, it can either be equipped with MOSFET outputs and Deutsch connectors or can have relay outputs with terminal block. Since the central unit can be exposed to very tough environments, the box is encapsulated to give protection from damp, heat, cold, dust, vibration and corrosive environments. The Central unit has short circuit protected inputs and outputs and has protection against reverse polarity, over-voltage, large incoming voltage transients and EMC/RF. Label Relay output The Relay output connectors are separated from the rest of the electronics in the central unit to create an electrically isolated output. The maximum load for each output is 10A. Through the terminal block, both the normally open and the normally closed connection points are available. Document type Instruction Manual 66063 Document number Rev A Page 4 of 8 Functions Two cable glands. 5 Relay outputs. Two cable glands. 10 Relay outputs. Models Model G5CU R5 G5CU R10 Expansion boards The main board may be used stand alone or together with one expansion board. There are several different expansion boards. All expansions boards have the same mechanical outline. They may have different funcionalities depending on customers application. The differnt functions are exemplified in the table below:
Description of expansion functions Relays Analog inputs Analog outputs Digital I/O PWM Number of exspansion function 1-5 1-10 1-5 1-20 1-5 Terminal schematics G5 CU R5 and G5 CU R10 1 15 1 17 Expansion board (49839) 1 = REL6, common 2 = REL6, normally closed 3 = REL6, normally open 4 = REL7, common 5 = REL7, normally closed 6 = REL7, normally open 7 = REL8, common 8 = REL8, normally closed 9 = REL8, normally open 10 = REL9, common 11 = REL9, normally closed 12 = REL9, normally open 13 = REL10, common 14 = REL10, normally closed 15 = REL10, normally open Main board 1 = GND 2 = Power Supply +
3 = REL1, common 4 = REL1, normally closed 5 = REL1, normally open 6 = REL2, common 7 = REL2, normally closed 8 = REL2, normally open 9 = REL3, common 10 = REL3, normally closed 11 = REL3, normally open 12 = REL4, common 13 = REL4, normally closed 14 = REL4, normally open 15 = REL5, common 16 = REL5, normally closed 17 = REL5, normally open ATTENTION!
After assembly make sure you tighten the housing screws with 0,8 Nm to avoid any water ingress. Document type Instruction Manual 66063 Document number Rev A Page 5 of 8 Technical Data Central Unit Attribute Housing material IP-class Ambient temperature Supply voltage Fuse Current consumption at idle Relay Output load Housing screw torque Weight Information Plastic PC IP67 (for versions with cable glands IP65)
-25C to +70C 9-36VDC Not required.
<30mA Max 10 A 0,8 Nm Approx. 0,35Kg m m 7 1 1 m m 6 8 1 127mm 57mm Size: approx. ~
127 x 117 x 57 mm / ~ 5,0 x 4,6 x 2,2 in. Document type Instruction Manual 66063 Document number Rev A Page 6 of 8 Radio information The G5 system family incorporates an automated frequency jumping technology, a reliable radio transmission highly resistant to interference. The radio transmission takes place within the ISM-band used at pre-defined channels. The channel switching takes place multiple times per second following a pseudorandom se-
quence. This ensures that transmission takes place on an optimal frequency at all times!
No transmitter uses the same pseudorandom sequence order when switching channels; this minimizes the risk of two G5 systems interfering with each other. The G5 Pocket is approved to transmit on the ISM band. The radio is license free for the end user. Technical information Attribute Frequency Channels management Channel order Channel capacity System address/ID Redundancy Range Information 2,400 - 2,4835 GHz FHSS DSSS THSS Pseudorandom Duplex
<16777216 unique system addresses available CRC-16 100 meters Document type Instruction Manual 66063 Document number Rev A Page 7 of 8 FCC information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Warning Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Industry Canada Information This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. CAN ICES-3 (A)/NMB-3(A) The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Lantenne (s) utilise pour cet metteur doit tre install pour fournir une distance de sparation dau moins 20 cm de toute personne et ne doit pas tre co-localises ou oprant en conjonction avec une autre antenne ou metteur.