OWLET IV NEMA NAM Luminaire Controllers Installation Instructions QR code to access the online installation instruction. DATALIFT N MESHNODE N IP 66 IK 08 PRODUCT DATALIFT N 90.7mm 3.57in Ta: -40C to +65C
-40F to +149F Mains voltage: 110-277V Frequency: 50/60Hz Max load current: 7.5A MESHNODE N 72.9mm 2.87in Ta: -40C to +65C
-40F to +149F Mains voltage: 110-277V Frequency: 50/60Hz Max load current: 7.5A 92.2mm 3.63in XX/XX FW: X.X.X.X SN: XXXXXXXXXXXXXXXX XX/XX FW: X.X.X.X SN: XXXXXXXXXXXXXXXX Red bottom kg lb 0.18kg 0.40lb Grey bottom BEST LOCATION, RATIO & DISTANCE 92.2mm 3.63in kg lb 0.23kg 0.51lb MAX. 500M DATALIFT 1 DATALIFT : 10 MESH MAX. 100M MESHNODES 1/5 www.schreder.comDOC-0023004 OWLET IV NEMA NAM-INS-B | 09-2023Copyright Schrder S.A. 2023 - Executive Publisher: Stphane Halleux - Schrder International Services sa - B-4000 Lige, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice. 1 Before installation contact Schrder FAE
(Field Application Engineer) for support. INSTALLATION 2 During installation, ensure correct body position over the luminaire. Q A FAE 3 Turning indications on top of controller. Hold controller. Controller 4 Align the longer pin (Neutral) first. NEMA Socket Align the controller power pins with slots in the socket. 5 1 Check if the surfaces between the controller and NEMA socket are parallel and plug in. 6 2 Push the controller firmly down. Make sure it is vertically aligned. 55 N
(12.5 lbf)
Correct position:
vertical Incorrect position:
twisted 2/5 www.schreder.comDOC-0023004 OWLET IV NEMA NAM-INS-B | 09-2023Copyright Schrder S.A. 2023 - Executive Publisher: Stphane Halleux - Schrder International Services sa - B-4000 Lige, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice. INSTALLATION 7 8 Turn controller 45 clockwise until it locks. VERIFICATION The installer is responsible for verifying the installation. Visual Verification 4.5 N.m
(3.3 lbf.ft) Correct installation:
Surfaces of controller and NEMA socket are parallel. Incorrect installation:
Surfaces of controller and NEMA socket are twisted. NEMA socket with internal RFID Symbol on controller and gasket are aligned. 9 Mechanical Verification NEMA socket with external RFID Symbol on controller and socket label are aligned. Pull the controller up to check if it is locked 10 Extra barcode labels are supplied with the controller Example list and map. Inside pole door 3/5 www.schreder.comDOC-0023004 OWLET IV NEMA NAM-INS-B | 09-2023Copyright Schrder S.A. 2023 - Executive Publisher: Stphane Halleux - Schrder International Services sa - B-4000 Lige, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice. 11 Note: the self-test occurs only in the first 5 power cycles after installing the controller. SELF-TEST 1 When powering on luminaire, the light switches ON to maximum level. 1 2 1 2 The controller reduces light to minimum level. 2 3 The controller switches OFF the light completely. 3 3 1 2 3 100%
10%
100%
100%
10%
100%
30 seconds 10%
10%
30 seconds 30 seconds 30 seconds Correct Luminaire is ON Incorrect Luminaire is OFF Built-in LED controller is ON 4 OPTIONAL SENSOR TEST trigger a sensor dectection in the luminaire Correct:
Light level changes from max to min 5 Incorrect:
Light level does not change 4 4 5 4 5 5 100% 10%
120 minutes 100% 10%
100% 10%
120 minutes 120 minutes 120 minutes 100% 10%
120 minutes After the self-test, the luminaire operates as configured on the CMS platform. 6 6 6 6 4/5 www.schreder.comDOC-0023004 OWLET IV NEMA NAM-INS-B | 09-2023Copyright Schrder S.A. 2023 - Executive Publisher: Stphane Halleux - Schrder International Services sa - B-4000 Lige, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice. Certification 12 FCC Regulatory Notices:
DATALIFT N NAM FCC ID: 2AW4F-OW4NDNAM Contains FCC ID: QOQMGM13P Contains FCC ID: XMR201909EG91NAX No changes shall be made to the device without the manufacturers permission as this may void the users authority to operate the device. The DATALIFT N NAM complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The DATALIFT N NAM complies with the safety requirements for RF exposure for mobile (>20 cm) use conditions in accordance with FCC rule part 2.1091. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. MESHNODE N NAM FCC ID: 2AW4F-OW4NMNAM Contains FCC ID: QOQMGM13P No changes shall be made to the device without the manufacturers permission as this may void the users authority to operate the device. The MESHNODE N NAM complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The MESHNODE N NAM complies with the safety requirements for RF exposure for mobile (>20 cm) use conditions in accordance with FCC rule part 2.1091. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ISED Canada Regulatory Notices:
DATALIFT N NAM IC:26343-OW4NDNAM Contains IC: 5123A-MGM13P Contains IC: 10224A-2019EG91NAX (for the DataLift) MESHNODE N NAM IC:26343-OW4NMNAM Contains IC: 5123A-MGM13P (for the MeshNode) This device is compliant with ISED Canada license-exempt RSS standards. Operation is authorised under the following two conditions:
1 - the device may not cause harmful interference;
2 - the device must accept any interference received, even if it compromises operation. Cet appareil est conforme aux normes CNR exemptes de licence dISDE Canada. Le fonctionnement est autoris sous les deux conditions suivantes :
1 - lappareil ne doit pas causer dinterfrences nuisibles ;
2 - lappareil doit accepter toute interfrence reue, mme si elle compromet son fonctionnement. This equipment complies with ISED Canada RSS-102 radiation exposure limits set forth for the general population. This equipment complies with the safety requirements for RF exposure in accordance with RSS-102 Issue 5 section 2.5.2 for mobile
(>20 cm) use conditions. The minimum compliance distance is 20 cm. Cet quipement est conforme aux limites dexposition aux radiations CNR-102 de lISDE Canada tablies pour la population gnrale. Cet quipement est conforme aux exigences de scurit pour lexposition aux radiofrquences conformment la section 2.5.2 de la norme CNR-102 Issue 5 pour les conditions dutilisation mobile (>20 cm). La distance minimale de conformit es de 20 cm. 5/5 www.schreder.comDOC-0023004 OWLET IV NEMA NAM-INS-B | 09-2023Copyright Schrder S.A. 2023 - Executive Publisher: Stphane Halleux - Schrder International Services sa - B-4000 Lige, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.