all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
USERS MANUAL | Users Manual | 240.94 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Setup Photos | |||||||
1 | Test Report |
1 | USERS MANUAL | Users Manual | 240.94 KiB |
THE IS-5000 USER MANUAL 2 TABLE OF CONTENTS 1. Getting Started ..................................................................................................................................... 3 2. Basic Functions .................................................................................................................................... 9 3. The Schedule Mode ............................................................................................................................. 13 4. Function Manual Basic User Management ...................................................................................... 18 6. Other Functions ................................................................................................................................. 24 7. Buzzer Sounds .................................................................................................................................... 25 8. The RFID Card (For Use With The Is-5000 RF Only) ...................................... Error! Bookmark not defined. 2 1. GETTING STARTED The IS-5000 standalone electronic door lock is an advanced-design electronic door lock that is ideal for high-security, medium-sized installations. It has been designed to ensure that the building or office is safe from unauthorized entry. This User guide is meant to help the user get the most from this amazing product. a.) Default Factory Settings & clock setting When the IS 5000 is new, it is set on default. The factory default mode is Normal Mode-No Schedule Is Programmed. To install and use one needs to check whether the IS-5000 is on factory default mode. To do this, power it on by inserting 5 AA batteries. If it is on factory default mode it shall:
Blink 5 times in alternating green and red lights If it is not on factory default mode, it will blink 5 times in red light. If this happens, the user will need to restore the factory mode by executing the function 358. Please make sure to set the clock ( RTC) while setting IS -
5000 for the first time.
- When the Clock ( RTC) is not set , melody ( No.8) will sound with Red light flashing. 3 b.) The Basics i.) User IDs and position numbers For anyone to work with the IS-5000, one must have an ID. The IS 5000 has 4 categories of IDs: the Master ID, the Manager ID, the Basic User ID, and the Service ID. Generally, each ID has a position number that ranges from 00 99. Position 1 is reserved for the Master ID, positions 00,10,20,30,40,50,60,70,80, and 90 are reserved for the Manager IDs, and the rest of the positions that fall within the range of 00 -99 are reserved for the basic Users. The position numbers for the Service/Visitor IDs are: 251, 252, and 253. The length of Master ID and the Manager ID is fixed at 7 digits and the default ID for the Master ID is 1234567; there is no default Manager ID. 3 ii.) User authority Each of the three main categories of Users has a specific authority. The basic user can only gain access but cannot conduct any programming functions. The Manager has access authority, and can also program with authority that is limited to some functions and to the corresponding group. For example, a Manager with a position number 00, can only program for basic Users with position numbers that fall within the 00-09 range. On the other hand, a Manager with a position number 50 can only program for basic Users with position numbers that fall within the 51-59 range. iii.) Access A.) By the use of an ID code: the person who wants to get access will enter the ID, and press
, to unlock. Remember that the Master and the Manager ID are made up of 7 digits whereas that of the basic User is made up of 4 to 7 digits. B.) By the use of proximity card (IS 5000 RF): the person who wants to gain access by use of a card will need to touch the antenna area of the IS-5000 with registered proximity card. 4 iv.) Programming A.) When a person is required to press the button during programming, the person must make sure that the time it takes to press it is not more than 1 second, unless the user guide expressly states that the button should be pressed for 4 seconds to enter the programming mode. B.) Programming can be also conducted through computer the software provided. Please refer to the IS 5000 PC manager program. v.) Record keeping Always keep user ID records for future reference. A separate page for this has been provided. C.) Startup Programming Functions The following programming functions need to be executed before proceeding with anything else. Note: Duplicated ID cannot be registered! ( error sounds when attempt) 4 Task Restore factory settings and clear all data (Skip this step if you checked and found that IS -5000 is on factory default mode ) Function Number Procedure Fn358 (Authorized To MASTER ID ONLY) for 4 seconds-> 358 ->
Enter 1234567->
(Note: 1234567 is the default master ID. Please use your ID in case you have already changed it.) To set the date (The date format is (MM/DD/YY) and the default date is 01/01/11.) Fn350 (Authorized To MASTER and MANAGER ID) Set the time (The time format is
(HHMM) and the default time is 12:00 (24hr clock.) Fn351 (Authorized To MASTER and MANAGER ID) To set the start of the daylight saving mode (The format is MMWD, where: MM = month, W= week (The weeks place in the month) D= day (1=MON 2=THU 3=WED 4=THU 5=FRI Fn337 (Authorized To MASTER and MANAGER ID) Enter the MASTER or MANAGER ID->
for 4 seconds-> 350-> MMDDYY ->
Example : Current date is 21st May, 2012 Enter 1234567 ->
for 4 seconds->350-> 052112 ->
Enter the MASTER or MANAGER ID->
for 4 seconds->351-> MMDDYY ->
Example: Current time is 13:00 Enter 1234567 ->
for 4 seconds -> 351-> 1300 ->
". Enter the MASTER or MANAGER ID->
for 4 seconds-> 337, Key in day to begin the daylight saving mode in the format MMWD->
For North America region:
Please note that daylights saving mode is set to default. No need to do a programming !
For the States daylight savings is not observed and want it to be disengaged, enter 0000 where MMWD (in example enter 0000 instead of 0327). Make sure to perform Fn 6 6=SAT 7=SUN)) 338 to complete. Example : Start the daylights saving time on the Sunday of the second week of March Enter 1234567->
Note: on the Sunday of the second week of March, the time will change from 2am to 3am. for 4 sec-> 337->
-> 0327 ->
. To set the end of the daylight saving mode.
(The format is MMWD, where:
MM = month, W= week (The weeks place in the month) D=
day (1=MON 2=THU 3=WED 4=THU 5=FRI 6=SAT 7=SUN)) Fn338 (Authorized To MASTER and MANAGER ID) Enter the MASTER or MANAGER ID->
for 4 seconds ->338-> Key in day to end the daylight saving time in the format MMWD ->
For North America region:
Please note that daylights saving mode is set to default. No need to do a programming !
For the States daylight savings is not observed and want it to be disengaged, enter 0000 where MMWD (in example enter 0000 instead of 1117). Example: to set the end of the daylights saving time on the Sunday of the 1st week of November for 4 sec -> 338->
Enter 1234567->
Note: The Sunday of the 1st week of November will end at 2am and the time will change to 1am.
->1117 ->
. Change master ID (Default is 1234567) (7 digits fixed) NONE (Authorized To MASTER ID) Enter the MASTER ID, Press for 4 seconds, Enter 1, press
, Enter the NEW MASTER ID, Press
, Re-Enter the NEW MASTER ID and Press 6 7 Create a new manager ID
(7 digits fixed) NONE (Authorized To MASTER ID) Example: Change Master ID to 7777777 Enter 1234567 ->
for 4 sec -> 1 ->
-> 7777777 ->
> 7777777->
. Enter the MASTER ID, Press
(00,10,20,30,40,50,60,70,80,90), for 4 seconds, Enter a manager position choose from Enter the NEW MANAGER ID, Press
, Re-Enter the NEW MANAGER ID, Press Example: creating a new manager with ID 4569870. position number00 Enter 1234567 ->
for 4sec -> 00->
-> 4569870 ->
4569870 ->
. Create a new Basic User ID
(4-7 digits) NONE (Authorized To MASTER ID and Corresponding Manager ID) Enter the MASTER ID or MANAGER ID, Press for 4 seconds, Enter position number from 00 to 99, but excluding 1, 00,10,20,30,40,50,60,70,80,90. Now enter the NEW USER ID, Press Example: create a new user with ID 1264 for position number 11.
, Re-Enter the NEW USER ID and then press Enter 1234567 ->
for 4sec -> 11 ->
-> 1264 ->
->1264 -
7 8 Enter Master ID, press for 4secs, Enter Group number./position number., Press touch the card to antenna area Please read note below before attempt to programming Example: Registering the Card ID for the user at position number 11. Register A New Proximity card
( IS 5000 RF only) NONE (Authorized To MASTER ID) for 4sec -> 111 ->
, touch the card to antenna Enter 1234567 ->
area Note: The Card ID shares the same group or position number with an ID code. To differentiate between the two, simply place 1 before position number or group number. For example, an ID code with position number 12 will have a Card ID position number of 112. There is an exception for position 1 (reserved for the master ID,) which uses an 2. for Card position number
** user ID at position number 12 for ID code and Position number 112 for card ID represent the same user. **
8 Task Function Number Procedure 9 2. BASIC FUNCTION a) Basic functions with no schedule 9 Enable all-time unlocked mode
(The lock stays unlocked at all times) Disable all-time unlocked mode
(The lock stays locked and no ID except the master ID will work ) 320 (Authorized To MASTER ID) 321 (Authorized To MASTER ID) 10 Enter MASTER ID, Press for 4 seconds, Enter 320 and press Enter 1234567->
for 4secs-> 320->
Enter MASTER ID, Press for 4 seconds, Enter 321 and press Enter 1234567->
for 4secs-> 321->
Enter 1234567->
for 4secs-> 322->
Enter MASTER ID, Press for 4 seconds, Enter 322 and press 322 (Authorized To MASTER ID) Disable functions 320 and 321 (If Fn 320/321 is active, this function will disable Fn 320 /321,and return IS 5000 to Normal) b.) Basic Functions with a Schedule To access specific times, either during the day or night, these functions will help make programming simple. However, before programming begins, one needs to take the following into consideration:
i.) More than one group can be allocated the different access time Blocks using the functions Fn330/Fn331 10 ii.) The functions 326,327,328,329 are preset fixed-time blocks 11 Task Set the earliest time to access. Function Number 330
(Authorized To MASTER ID and Corresponding Manager ID) This function must be paired with function 331 Procedure Enter the MASTER or MANAGER ID, Press for 4 seconds, Enter 330, press
, Enter the Group
, Enter day of the week, Press number, press Example: when setting access starting time of group number 10 to Mon Fri 8 am to 5 pm.
, Enter opening time in the format HHMM Enter 1234567->
for 4 sec -> 330 ->
-> 10 for group number->
-> 8 for Mon- Fri->
-> 0800 for 8 am ->
Note: if the access time is applicable to all groups, then one will need to enter i.e, 00, 10, 20, 30, 40, 50, 60,.90. If it is just for one group, then just enter the specific group number i.e, 00, 10, 20, 30, 40, 50, 60,.90. Each day of the week has been allocated to a specific code as follows: 0 = all days, 1=Mon, 2=Tue, 3=Wed, 4=Thu, 5=Fri, 6=Sat, 7=Sun, 8=Mon thru Fri, 9=sat and sun HHMM = opening time
(07:00 for 7 am, 13:00 for 1 pm) for all the group numbers 11 Set the latest time to access 331
(Authorized To MASTER ID and Corresponding Manager ID) This function must be paired with function 330 To set IS-5000 to stay unlocked for set time (from 7 am 5pm) To Undo function 323 and return to schedule mode 323
(Authorized To MASTER ID and Corresponding Manager ID ) 324(Authorized To MASTER ID and Corresponding Manager ID) Enter the MASTER or MANAGER ID, Press for 4 seconds, Enter 330, press
, enter the Group 12
, Enter day of the week, Press number, press Example: when setting access closing time of group number 10 to Mon Fri 8 am to 5 pm.
, Enter closing time in the format HHMM Enter 1234567->
for 4 sec -> 330 ->
-> 10 for group number->
-> 8 for Mon- Fri->
-> 1700 for 5pm ->
Note: if the access time is applicable to all groups, then one will just need to enter for all the group numbers i.e, 00, 10, 20, 30, 40, 50, 60,.90. If it is just for one group, then one will just need to enter the specific group numbers (i. e, 00, 10, 20, 30, 40, 50, 60,.90.). Each day of the week has been allocated to a specific code as follows: 0 = all days, 1=Mon, 2=Tue, 3=Wed, 4=Thu, 5=Fri, 6=Sat, 7=Sun, 8=Mon thru Fri, 9=sat and sun HHMM = Closing time (07:00 for 7 am, 13:00 for 1 pm) This function is activated after first responding ID is entered. Either Fn 326/327/328/329 or Fn 330/331 needs to be activated before use of this function. Once the first user ID is entered after 7:00 AM, the IS-5000 stays unlocked until 5:00 PM Enter 1234567 or Manager ID->
for 4 sec-> 323->
Either Fn 326/327/328/329 or Fn 330/331 needs to be activated before use of this function. This function ensures that the lock reverts to programmed schedule mode and schedule mode. Enter 1234567 or Manager ID->
for 4 sec-> 324->
12 13 To set the IS-5000 to stay unlocked for a specific period within the scheduled time 325
(Authorized To MASTER ID and Corresponding Manager ID ) This function is activated after the first responding ID is entered. The minimum set time is 1 hour while the maximum sets time is 12 hours. Enter 1234567 or Manager ID, press for 4 sec, Enter 325 , press Enter HH, press
, Example: if the set time is 2 hours, the IS 5000 will stay unlocked for two hours from the time the first ID is entered. Enter 1234567 or Manager ID->
for 4 sec-> 325->
-> 02 for 2 hours->
3. THE SCHEDULE MODE a.) Quick schedule The quick schedule contains a number of preset time-blocks designed to make it easier to set up a schedule. Task Function Number To activate the Business Hour Quick Schedule which allows for access during preset business hours from Monday to 326 (Authorized To MASTER ID and Corresponding Manager ID) This function can be set for all users or for specific groups. Procedure Example: To apply quick business hour schedule mode to all group ( to select all group press
) Enter 1234567 or Manager ID->
for 4 sec, enter 326->
13 Friday (7:00 AM to 6:00 PM) To activate the Daytime Quick Schedule which allows for access during preset daytime hours everyday (7:00 AM to 6:00 PM) 327 (Authorized To MASTER ID and Corresponding Manager ID) This function can be set for all users or for specific groups. To activate the Evening Time Quick Schedule which allows for access during preset evening hours everyday (3:00 PM to 1:00 AM) 328 (Authorized To MASTER ID and Corresponding Manager ID) This function can be set for all users or for specific groups. 14 Example: To apply quick business hour schedule mode to group number 10 Enter 1234567 or Manager ID->
for 4 sec-> 326->
> 10->
Example: To apply quick daytime hour schedule mode to all groups ( to select all group press
) Enter 1234567 or Manager ID->
for 4 sec-> 327->
for all groups->
Example: To apply quick daytime hour schedule mode to group number 10 Enter 1234567 or Manager ID->
for 4 sec-> 327->
> 10 ->
Example: To apply quick evening time schedule mode to all groups
( to select all group press
) Enter 1234567 or Manager ID->
for 4 sec-> 328->
Example: To apply quick evening time schedule mode to group number 10 Enter 1234567 or Manager ID->
for 4 sec-> 328->
-> 10->
14 To activate the Night time Quick Schedule which allows for access during preset night hours everyday (11:00 PM to 9:00 AM) 329 (Authorized To MASTER ID and Corresponding Manager ID) This function can be set for all users or for specific groups. Example: To apply quick Night time schedule mode to all groups
( to select all group press
) 15 Enter 1234567 or Manager ID->
Example: To apply quick Night time schedule mode to group number 10 for 4 sec-> 329->
Enter 1234567 or Manager ID->
for 4 sec-> 329->
10->
b.) Extended/Reduced Times There are some unique users or circumstances that may require the User to set special access times or schedules that are different from the other users. These functions in this section will be useful when coming up with such a schedule. Task To enable a group to access the premise for up to 9 hours beyond scheduled time. Basic schedule time and date is decided by group setting with Fn330/331 or quick schedule function applied enter ALL or group number, press Example: To set 2 hours of overtime hour to all groups ( to select all group press Function Number 333 (Authorized To MASTER ID and Any Manager ID) Example: To set 2 hours of overtime hour to group number 10 Enter 1234567 or Manager ID->
Enter 1234567 or Manager ID, press for 4 sec, Enter 333 , press Procedure for 4 sec-> 333->
, enter H, press
-> 2 ->
, enter
) 15 Enter 1234567 or Manager ID->
for 4 sec-> 333->
-> 10
-> 2 ->
16 334 (Authorized To MASTER ID and Any Manager ID) To enable a group to access the premise for up to 9 hours less than the scheduled time. Basic schedule time and date is decided by group setting with Fn330/331 or quick schedule function applied Enter 1234567 or Manager ID, press for 4 sec, Enter 334 , press
, enter ALL or group number, press Example: To set 2 hours of overtime hours to all groups ( to select all group press
, enter H, press
) Enter 1234567 or Manager ID->
for 4 sec-> 334->
-> 2 ->
Example: To set 2 hours of overtime hours to group number 10 Enter 1234567 or Manager ID->
for 4 sec-> 334->
-> 10
-> 2 ->
16 To enable a specific user to access the premise for up to 9 hours beyond scheduled time. Basic schedule time and date is decided by group setting with Fn330/331 or quick schedule function applied To clear extended or reduced time slots by undoing functions 333,334, and 335 To disable a schedule mode setting and return to normal mode ( no time restriction) This function can be set to disable All or each group. 17 335 (Authorized To MASTER ID and Any Manager ID) This function can be set for up to 4 user IDs The user must enter during scheduled hour. If the User belongs to a group that has schedule time of 7am-5pm from Mon Fri, the first access needs to be made at or after 7am and before 5pm. Extended time can be end after 5 pm Position number = 01,02,.97,98,99. Example: To set 9 hours of extended time to user ID position number 11 Enter 1234567 or Manager ID->
for 4 sec-> 335->
-> 11 336 (Authorized To MASTER ID and Any Manager ID) 310 (Authorized To MASTER ID ) for position number 11->
-> 9 for 9hours ->
Example: Enter 1234567 or Manager ID->
for 4 sec-> 336->
Enter 1234567, press for 4sec, Enter 310, press
,Enter All or each Group number. press Example: To disable all groups or group number 10
, Enter 1234567->
for 4sec-> 310->
for all or 10 for group number 10 ->
. 17 18 4. FUNCTION MANUAL BASIC USER MANAGEMENT 18 19 Task To delete all user IDs except Master ID Function Fn301(authorized to Master ID ONLY Delete a specific group Fn302(authorized to Master ID ONLY) Delete a specific user Fn303 (authorized to Master ID and Corresponding Group Manager ID) Procedure Enter 1234567, press for 4 sec, enter 301 , press Example: Enter 1234567->
for 4 sec-> 301->
Enter 1234567, press for 4 sec, Enter 302, press
, enter Group number, press Group number =00,10,20,30,.80,90 Example: to delete group number 10 Enter 1234567->
for 4sec-> 302->
-> 10 for group number 10 ->
, enter Position number, press Enter 303, Press Position number =01,02,03.98,99 Example: To delete the user ID at position number 11 Enter 1234567 or manager ID of responding group->
To disable (lock out) All IDs except master ID Fn307 (authorized to Master ID ONLY) 11->
19 Enter 1234567->
for 4sec-> 307->
for 4 sec-> 303->
-> 11 for position number To disable (lock out) a specific group Fn308 (authorized to Master ID ONLY) To disable (lock out) an individual user Fn309 (authorized to Master ID and Corresponding Group Manager ID) and 20 Enter 1234567, press for 4sec, Enter 308 , press
, Enter GROUP number, press Group number = 00,10,20,30,40,50,60,70,80,90 Example: To disable group number 10 Enter 1234567->
for 4 sec -> 308->
-> 10 for group number 10 ->
Enter 1234567, press for 4sec, Enter 309 ,press
, Enter Position number press Position number =01,02,03.98,99 Example: To disable user at position number 11 Enter 1234567 or Manager ID of responding group->
for 4sec-> 309->
-> 11 for position number 11
20 Enable all users (undo Fn307) Fn304 (authorized to Master ID ONLY) Enter 1234567->
for 4sec-> 304->
21 Enable a specific group (undo Fn308) Fn305 (authorized to Master ID ONLY) Enable a specific user (undo Fn309) Fn306 (authorized to Master ID and Corresponding Group Manager ID) Enter 1234567, press for 4sec, Enter 305 , press
, Enter Group number, press Group number = 00,10,20,30,40,50,60,70,80,90 Example: To enable group number 10 Enter 1234567->
for 4 sec -> 308->
-> 10 for group number 10 ->
Enter 1234567, press for 4sec, Enter 306 ,press
, Enter Position number, press Position number =01,02,03.98,99 Example: To enable user at position number 11 Enter 1234567 or Manager ID of responding group->
for 4sec-> 309->
-> 11 for position number 11
21 22 5. THE SPECIAL FEATURES This section deals with specific functions that make the operation of the IS -5000 user friendly. By using them the User can: a.) limit the number of attempts of ID input to guard against trial and error input. b.) set the delay time between each key input to fit individual user speed and c.) set the stay-open time after IS 5000 unlocked by ID input. Task To set the number of allowed incorrect ID inputs (ranging from 3-9 times.) The default setting is 4 times. 9) , press Example: To change number of attempt to 5 times Procedure for 4 sec, Enter 341, press for 4 sec -> 341->
Enter 1234567, press Enter 1234567->
-> 5 for 5
, enter (3-
Function Fn341 (authorized to Master ID and Corresponding Group Manager ID) After the set number of times of incorrect trials, the IS 5000 is locked out for a pre-set amount of time ( set the time with Fn 342) times->
22 To set the length of lockout time after number of incorrect ID input trials. Default setting is 30 sec
(and the User can set this to be 9~
60 sec) Disable or Enable functions 341 and 342. Default setting is 1 ( 0 disabled, 1 = enabled) To set the interval time from opening by ID entered to re-locked. Default setting is 3 sec (able to set 2~ 60 sec) To set the delay time each key input
( if setting 5 sec, after first key entered, next key must entered within 5sec for the IS 5000 to stay active ) Default setting is 5 (able to set 2~ 9 Fn342 (authorized to Master ID and Corresponding Group Manager ID) After the set number of times of incorrect trials, the IS 5000 is locked out for a pre-set amount of time. Fn343 (authorized to Master ID and Corresponding Group Manager ID) Fn340 (authorized to Master ID and Corresponding Group Manager ID) Fn344 (authorized to Master ID and Corresponding Group Manager ID) 23 Enter 1234567, press for 4 sec, Enter 342 press
,enter Seconds (9-60),press Example: To change time to 50 sec. Enter 1234567->
for 4sec-> 342->
-> 50 for 50 sec.->
Example: To disable function 341,342 Enter 1234567 ->
for 4 sec -> 343 ->
-> 0 for disable ->
Enter 1234567, press for 4sec-Enter 340 ,press
,Enter time sec ,press Example: To change the time to 15 sec Enter 1234567->
for 4 sec-> 340->
-> 15 for 15 sec->
Enter 1234567, press for 4sec, enter 344 ,press
,Enter seconds (2-
9), press Example: To change the time to 7 sec Enter 1234567->
for 4 sec-> 344->
-> 7 for 7 sec->
23 sec) To set the sounds on/ off Default setting is 1 (Normal sounds)
( 0= mute, 1= weak sounds,2 = normal sounds) Fn345 (authorized to Master ID and Corresponding Group Manager ID) 24 Enter 1234567, press for 4sec- Enter 345 press enter 0 0r 1 or 2 press Example: To change to Mute(0) Enter 1234567->
for 4 sec-> 345->
-> 0 for mute->
6. OTHER FUNCTIONS Exit-Input (for relay ) F346 (Authorized to Master/Manager IDs) Exit Output (for relay) F347 (Authorized to Master/Manager IDs) 24 Enter 1234567, Press for 4 Sec, ->
,Enter (0-3) ->
346->
Default setting is 0 = Disable ( 0=Disable, 1=
Rise, 2= Fail , 3 = Rise/Fail ) When input outside signal Enter 1234567->
for 4 sec->
347 ->
, enter (0-3) ->
To warn low battery F348 (Authorized to Master/Manager IDs) To delete all logs Fn 360 (Authorized to Master) this function is designed to delete logs from IS-5000 not using the PC manager software 25 Default 0 = Disable ( 0=Disable, 1= 1 sec On, 2= 2 sec On , 3 = 3 sec On ) When output the signal ( able to set 1- 3 sec) Enter 1234567->
for 4 sec ->348
, enter (0-1) ->
press Default setting is 1 = 200 times ( 0=Disable, 1=
200 times) When battery reaches low limit, a warning beep for battery replacement will sound with every access up to 200 times. Enter 1234567->
for 4 sec->
360->
, enter 1 ->
7. BUZZER SOUNDS The IS-5000 produces different sounds that are meant to ensure that users find it easy to recognize the status of the IS 5000 when operating it. Here are lists of buzzer sounds and what they are about
(please download from our website). a.) Initial Power On 007 Sounds when the real time clock (RTC) is registered normally with power on 008 Sounds when the real time clock is unregistered with power on b.) Error Sounds 001 - Sounds after allowing the maximum number of incorrect ID trials as specified in Function 341, Also sounds when a wrong time or digit number is entered during programming 003 When duplicated user ID is attempted to register 25 009 Sounds when a user enters the wrong ID, spends more than the required time to key in while programming, when out of range digits user ID is attempted to register. c.) General Sounds 002 Normal button sounds 004 When the door unlocks 005 When the door locks 006 When the battery power is low; please change batteries immediately 010 When Program starts 011 - When Program ends 26 26 8. THE PROXIMITY CARD (FOR USE WITH THE IS-
5000 RF ONLY) The Card ID shares the same group number or position number with an ID code. To differentiate between the two, simply place 1 before the ID code to get the Card ID. For example, an ID code with position number 12 will have an ID of 112. There is an exception for position 1 (reserved for the master ID,) uses a Card ID of 2. a.) Registering a card ID To register a new card: Enter Master ID or corresponding group Manager ID , press for 4secs, Enter position number., Press touch the card to antenna area, press Example 1: Registering the Card for user ID Code at position 11. Enter 1234567 , press for 4sec , enter 111 , press
, touch the card to antenna area, press This card is registered at position number. 11 (remember to add 1 before the position number) 27 Example 2: Registering the Card for user ID Code at position 10. for 4sec , enter 110 , press Enter 1234567 , press
, touch the card to antenna area IS 5000. This card is registered at position number. 10 and is recognized as manager ID for position number 10 Task Function Procedure Remember:
If the IS 5000 is set on schedule mode, card access will also work under schedule mode rules 27 To delete all Card IDs except Master Card ID ( ID code and card ID will be deleted at the same time with this function) Delete a specific groups Card IDs (if original group number is used , both ID code and Card ID will be deleted for the specific group. If a card group number ( add 1 before group number)is used, only the card ID will be deleted but the specific group ID code will remain) Delete a specific Card ID 28 Fn301(authorized to Master ID ONLY) Fn302(authorized to Master ID ONLY) Fn303 (authorized to Master ID and Corresponding Group Manager ID) Enter 1234567, press for 4 sec, enter 301 , press Example: Enter 1234567->
for 4 sec-> 301->
Enter 1234567, press for 4 sec, Enter 302, press
, enter Group number, press Example: to delete cards for group number 10 Enter 1234567->
for 4sec-> 302->
-> 110 for group number 10 ->
Enter 303, Press Example: To delete the user ID at position number 11
, enter Position number, press Enter 1234567 or manager ID of responding group->
for 4 sec-> 303->
-> 111 for position number 11->
If IS 5000 is set to always unlock with fn321, the card will not work An unregistered card will make error sounds If IS 5000 is set to fn307~309, corresponding card on the position will also work under the function mode. Deleting an ID code will cause a card ID to be deleted, but deleting a card ID will not cause and ID code to be deleted. c.) Deleting a Card ID 28 Appendix 1: ID code Log sheet ID Register ID Register access with ID access with ID GROUP USER SERVICE 2012-08-22 MASTER ID MUST have 7Digits, and the factory default Master ID is= 1234567 MASTER ID MUST have 7Digits, and the factory default Master ID is= 1234567 Enter Master ID ( factory default) , Press # for 4 Sec , Enter 1 , Press # , Enter New Master ID Press #, Re-
Enter Master ID ( factory default) , Press # for 4 Sec , Enter 1 , Press # , Enter New Master ID Press #, Re-
Enter New ID, Press # , Enter New ID, Press # , MASTER / MANAGER/ USER ID MASTER / MANAGER/ USER ID Enter Registered ID (4-7 Digit) , press # Unlock Enter Registered ID (4-7 Digit) , press # Unlock 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 251 252 253 Visitor ID can be between 4-7Digits , access time can be set between 1H ~ 24H. Authorized to MASTER,MANAGER ID Enter master or manager ID, Enter Service no. push # for 4 Sec, Enter Temp ID push #,Enter time HH, push #, ID will be cleared after access time passed IS-5000 29 29 1 30 Appendix 2. RFCARD ID Log sheet CARD register Enter master IDpush # for 4 sec enter position no. push # touch the card push #
OPEN with card approach the card to antenna area to access. GROUP 100 110 120 130 140 150 160 170 180 190 XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXXX XXXXXXXX 101 111 121 131 141 151 161 171 181 191 102 112 122 132 142 152 103 113 123 133 143 53 104 114 124 134 144 154 USER 105 115 125 135 145 155 106 116 126 136 146 156 107 117 127 137 147 157 108 118 128 138 148 158 109 119 129 139 149 159 62 63 64 65 66 67 68 69 172 182 192 173 183 193 174 184 194 175 185 195 176 186 196 177 187 197 178 188 198 179 189 199 2012-10-05 IS-5000 30 5 31 31 32 FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 32 33 IC Warning
"This device complies with Industry Canada licence-exempt RSS standard(s)."
Operation is subject to the following conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas provoquer de brouillage, et (2) l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 33
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2013-08-23 | 0.125 ~ 0.125 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2013-08-23
|
||||
1 | Applicant's complete, legal business name |
Secuway Inc.
|
||||
1 | FCC Registration Number (FRN) |
0022890701
|
||||
1 | Physical Address |
4860 Irvine Blvd, Suite 207
|
||||
1 |
Irvine, California 92620
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AARW
|
||||
1 | Equipment Product Code |
IS5000
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
N****** L********
|
||||
1 | Telephone Number |
650-9********
|
||||
1 | Fax Number |
650-9********
|
||||
1 |
n******@secuwayinc.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 02/19/2014 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | DIGITAL DOOR LOCK | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SGS Korea Co., Ltd.
|
||||
1 | Name |
F**** L********
|
||||
1 | Telephone Number |
82(0)********
|
||||
1 | Fax Number |
82(0)********
|
||||
1 |
f******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC