FCC ID: SDBR100NA Base Station transceiver

by: Sensus Metering Systems Inc. latest update: 2021-04-02 model: R100NA

Two grants have been issued under this FCC ID from 01/26/2017 to 04/02/2021 (this is one of three releases in 2021 for this grantee). Public details available include frequency information, manuals, and internal & external photos. some products also feature user submitted or linked instructions, warrantee terms, troubleshooting guides, drivers, & password defaults.
permalink for this FCC identifier
search for: Repair details
from iFixIt
Replacement
on Amazon
Trade-in? Recycling locations
eg is reader-supported. when you buy through links on our site, we may earn an affiliate commission.
|
|
|   
eg for Slack usage
app s submitted / available
1 2 Agency Agreement Cover Letter(s) pdf 226.26 KiB April 02 2021
1 2 Confidentiality Request Cover Letter(s) pdf 260.47 KiB April 02 2021
1 2 FCC Cover Letter Cover Letter(s) pdf 206.85 KiB April 02 2021
1 2 Manual Users Manual pdf April 02 2021 confidential
1 2 NDA Agreement Cover Letter(s) pdf 42.38 KiB April 02 2021
1 2 RF Exposure RF Exposure Info pdf 138.91 KiB April 02 2021
1 2 External Photos External Photos pdf 17.26 KiB
1 2 ID Label/Location Info pdf
1 2 Cover Letter(s) pdf
1 2 Attestation Statements pdf
1 2 Test Report pdf
1 2 Test Setup Photos pdf
1 2 Agency Agreement Cover Letter(s) pdf 226.26 KiB April 02 2021
1 2 Confidentiality Request Cover Letter(s) pdf 260.47 KiB April 02 2021
1 2 FCC Cover Letter Cover Letter(s) pdf 206.85 KiB April 02 2021
1 2 NDA Agreement Cover Letter(s) pdf 42.38 KiB April 02 2021
1 2 RF Exposure RF Exposure Info pdf 138.91 KiB April 02 2021
1 2 External Photos External Photos pdf 17.26 KiB

frequency equipment class purpose
1 2021-04-02 959.85 ~ 960 PCB - PCS Licensed Transmitter Class II Permissive Change
2 2017-01-26 959.85 ~ 960 PCB - PCS Licensed Transmitter Original Equipment

Application Forms

app s Applicant Information
1 2 Effective 2021-04-02
1 2 2017-01-26
1 2 Applicant's complete, legal business name Sensus Metering Systems Inc.
1 2 FCC Registration Number (FRN) 0003180007
1 2 Physical Address 639 Davis Drive
1 2 Morrisville, NC
1 2 Morrisville, North Carolina 27560
1 2 United States
app s TCB Information
1 2 TCB Application Email Address j******@tuvsud.com
1 2 j******@acstestlab.com
1 2 TCB Scope B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
app s FCC ID
1 2 Grantee Code SDB
1 2 Equipment Product Code R100NA
app s Person at the applicant's address to receive grant or for contact
1 2 Name M******** R******** B****
1 2 R**** D********
1 2 Title Sr. Director, Global System Test
1 2 Director, Engineering NPI and Project Management
1 2 Telephone Number 919-3********
1 2 919-4********
1 2 Fax Number 919-3********
1 2 E-mail r******@xylem.com
1 2 R******@sensus.com
app s Technical Contact
n/a
app s Non Technical Contact
n/a
app s Confidentiality (long or short term)
1 2 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 2 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 2 Is this application for software defined/cognitive radio authorization?No
1 2 Equipment ClassPCB - PCS Licensed Transmitter
1 2 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)Base Station transceiver
1 2 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 2 Modular Equipment TypeSingle Modular Approval
1 2 Purpose / Application is forClass II Permissive Change
1 2 Original Equipment
1 2 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 2 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 2 Grant CommentsModular Approval. Power listed is conducted. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Class II Change to add higher gain antenna. The transmitter must be installed to provide a separation distance of at least 228 cm from all persons.
1 2 Modular Approval. Power listed is conducted. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 47 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.
1 2 Is there an equipment authorization waiver associated with this application?No
1 2 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 2 Firm Name TUV SUD America, Inc.
1 2 Name W**** E****
1 2 S******** W********
1 2 Telephone Number 813-2********
1 2 770-8********
1 2 Fax Number 770-8********
1 2 E-mail W******@tuvsud.com
1 2 s******@tuvam.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 24D 901 902 3.8 1 ppm 4K80F2D
1 2 24D 901 902 3.8 1 ppm 9K60F2D
1 3 24D 901 902 3.8 1 ppm 1K10F2D
1 4 24D 901 902 3.8 1 ppm 5K00F1D
1 5 24D 901 902 3.8 1 ppm 5K60F1D
1 6 24D 901 902 3.8 1 ppm 5K90F1D
1 7 24D 901 902 3.8 1 ppm 10K0F1D
1 8 24D 901 902 3.8 1 ppm 11K3F1D
1 9 24D 901 902 3.8 1 ppm 11K9F1D
1 1 24D 930 931 3.8 1 ppm 5K90F1D
1 11 24D 930 931 3.8 1 ppm 11K8F1D
1 12 24D 930 931 3.8 1 ppm 4K70F1D
1 13 24D 930 931 3.8 1 ppm 9K30F1D
1 14 24D 940 941 3.8 1 ppm 5K90F1D
1 15 24D 940 941 3.8 1 ppm 11K8F1D
1 16 24D 940 941 3.8 1 ppm 4K70F1D
1 17 24D 940 941 3.8 1 ppm 9K30F1D
1 18 101C 928.85 929 3.8 1 ppm 4K80F2D
1 19 101C 928.85 929 3.8 1 ppm 9K60F2D
1 2 101C 928.85 929 3.8 1 ppm 1K10F2D
1 21 101C 928.85 929 3.8 1 ppm 5K00F1D
1 22 101C 928.85 929 3.8 1 ppm 5K60F1D
1 23 101C 928.85 929 3.8 1 ppm 5K90F1D
1 24 101C 928.85 929 3.8 1 ppm 10K0F1D
1 25 101C 928.85 929 3.8 1 ppm 11K3F1D
1 26 101C 928.85 929 3.8 1 ppm 11K9F1D
1 27 101C 932 932.5 3.8 1 ppm 4K80F2D
1 28 101C 932 932.5 3.8 1 ppm 9K60F2D
1 29 101C 932 932.5 3.8 1 ppm 1K10F2D
1 3 101C 932 932.5 3.8 1 ppm 5K00F1D
1 31 101C 932 932.5 3.8 1 ppm 5K60F1D
1 32 101C 932 932.5 3.8 1 ppm 5K90F1D
1 33 101C 932 932.5 3.8 1.5 ppm 10K0F1D
1 34 101C 932 932.5 3.8 1 ppm 11K3F1D
1 35 101C 932 932.5 3.8 1 ppm 11K9F1D
1 36 101C 941 941.5 3.8 1 ppm 5K90F1D
1 37 101C 941 941.5 3.8 1 ppm 11K8F1D
1 38 101C 941 941.5 3.8 1 ppm 4K70F1D
1 39 101C 941 941.5 3.8 1 ppm 9K30F1D
1 4 101C 952 953 3.8 1 ppm 5K90F1D
1 41 101C 952 953 3.8 1 ppm 11K8F1D
1 42 101C 952 953 3.8 1 ppm 4K70F1D
1 43 101C 952 953 3.8 1.5 ppm 9K30F1D
1 44 101C 959.85 960 3.8 1.5 ppm 5K90F1D
1 45 101C 959.85 960 3.8 1.5 ppm 11K8F1D
1 46 101C 959.85 960 3.8 1 ppm 4K70F1D
1 47 101C 959.85 960 3.8 1 ppm 9K30F1D
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
2 1 24D 901 902 3.8 1 ppm 4K80F2D
2 2 24D 901 902 3.8 1 ppm 9K60F2D
2 3 24D 901 902 3.8 1 ppm 1K10F2D
2 4 24D 901 902 3.8 1 ppm 5K00F1D
2 5 24D 901 902 3.8 1 ppm 5K60F1D
2 6 24D 901 902 3.8 1 ppm 5K90F1D
2 7 24D 901 902 3.8 1 ppm 10K0F1D
2 8 24D 901 902 3.8 1 ppm 11K3F1D
2 9 24D 901 902 3.8 1 ppm 11K9F1D
2 1 24D 930 931 3.8 1 ppm 5K90F1D
2 11 24D 930 931 3.8 1 ppm 11K8F1D
2 12 24D 930 931 3.8 1 ppm 4K70F1D
2 13 24D 930 931 3.8 1 ppm 9K30F1D
2 14 24D 940 941 3.8 1 ppm 5K90F1D
2 15 24D 940 941 3.8 1 ppm 11K8F1D
2 16 24D 940 941 3.8 1 ppm 4K70F1D
2 17 24D 940 941 3.8 1 ppm 9K30F1D
2 18 101C 928.85 929 3.8 1 ppm 4K80F2D
2 19 101C 928.85 929 3.8 1 ppm 9K60F2D
2 2 101C 928.85 929 3.8 1 ppm 1K10F2D
2 21 101C 928.85 929 3.8 1 ppm 5K00F1D
2 22 101C 928.85 929 3.8 1 ppm 5K60F1D
2 23 101C 928.85 929 3.8 1 ppm 5K90F1D
2 24 101C 928.85 929 3.8 1 ppm 10K0F1D
2 25 101C 928.85 929 3.8 1 ppm 11K3F1D
2 26 101C 928.85 929 3.8 1 ppm 11K9F1D
2 27 101C 932 932.5 3.8 1 ppm 4K80F2D
2 28 101C 932 932.5 3.8 1 ppm 1K10F2D
2 29 101C 932 932.5 3.8 1 ppm 5K00F1D
2 3 101C 932 932.5 3.8 1 ppm 5K60F1D
2 31 101C 932 932.5 3.8 1 ppm 5K90F1D
2 32 101C 932 932.5 3.8 1 ppm 9K60F2D
2 33 101C 932 932.5 3.8 1 ppm 10K0F1D
2 34 101C 932 932.5 3.8 1 ppm 11K3F1D
2 35 101C 932 932.5 3.8 1 ppm 11K9F1D
2 36 101C 941 941.5 3.8 1 ppm 5K90F1D
2 37 101C 941 941.5 3.8 1 ppm 11K8F1D
2 38 101C 941 941.5 3.8 1 ppm 4K70F1D
2 39 101C 941 941.5 3.8 1 ppm 9K30F1D
2 4 101C 952 953 3.8 1 ppm 5K90F1D
2 41 101C 952 953 3.8 1 ppm 11K8F1D
2 42 101C 952 953 3.8 1 ppm 4K70F1D
2 43 101C 952 953 3.8 1 ppm 9K30F1D
2 44 101C 959.85 960 3.8 1 ppm 5K90F1D
2 45 101C 959.85 960 3.8 1 ppm 11K8F1D
2 46 101C 959.85 960 3.8 1 ppm 4K70F1D
2 47 101C 959.85 960 3.8 1 ppm 9K30F1D

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC