FEATURES
250CFH or 400 CFH meter class options
Live temperature compensation
Fixed factor pressure compensation
Alarm notifications
Configurable volume pulse output
Configurable scrolling LCD display
20-year battery life
FlexNet SmartPoint inside (available with or without) IDENTIFICATION The SonixIQ meter with the FlexNet module will have a visible label containing the following information:
Model: SONIXIQ
FCC ID: SDBSONIXIQ
IC: 2220A-SONIXIQ SonixIQ Quick Guide The SonixIQ is a solid state residential gas meter, providing pinpoint accuracy of ultrasonic measurement and no moving parts to replace or wear out over time. Available with or without an integrated FlexNet radio, the SonixIQ covers both 250 or 400 CFH needs. The SonixIQ has an LCD display that supports walk up readings and status, an optical port that can be used with the SonixCom tool for configuration, a pulse output, and an optional integrated radio for communication across the Sensus FlexNet system. Application and Safety The SonixIQ should be used with clean, dry natural gas or air only. The meter electronics are enclosed in a vented case that provides both weather and EMC protection. Only suitable non incendive circuits and non incendive field wiring should be connected to the field wiring terminals via the pulse cable. Meter Specifications SonixIQ 250 series Capacity 250 to 299 cfh at 1/2 differential 400 series 400 to 450 cfh at 1/2 differential Connections 20LT connections on 6 center to center 30LT connections on 6 center to center MAOP 10 psig Dimensions 9.94 L x 4.38 W x 7.89 H (25.25cm L x 11.13cm W x 20.04cm H) Weight 6.3 lb (2.86 kg) Operating Temperature Humidity
-40 to +150F (-40 to +66C) 0 to 95% relative humidity operating and storage (non-condensing and condensing) QUICK GUIDEGQG-10004-01 SonixIQ Quick Guide Basic Installation Meter options are set at the factory and are determined according to the order specifications. 1. Shut the gas off at the inlet and outlet valves and remove the existing meter if present. 2. Connect the new SonixIQ to the pipe connections using an appropriate wrench. 3. Open the inlet and outlet valves to allow gas to flow through the meter. 4. Read the meter alarm status via the LCD display to confirm there are no active alarms. 5. If an initial reading is required at time of installation, the volume totalizer should be set to initial reading. Connect a handheld tool (HHD) running FieldLogic to the optical port to initiate the meter with a known reading. Configure the FlexNet SmartPoint Module with FieldLogic The FlexNet SmartPoint module is embedded in the SonixIQ as an option. If ordered, the SmartPoint module is already configured to the appropriate frequency. Once the SmartPoint module is activated, the SonixIQ can send messages through the FlexNet AMI system. 1. Connect a handheld tool (HHD) running FieldLogic to the optical port of the SonixIQ. 2. Launch FieldLogic Tools. 3. Enter the FlexNet ID of the SmartPoint Module, tap Start Connection, and then Activate and Configure as desired. Note: The FlexNet ID is on the front cover of the SonixIQ. GQG-10004-01 SonixIQ Warnings & Hazards ATTENTION RADIATION HAZARD Any modifications made to this device that are not approved by Sensus may void the authority granted to the user by the FCC to operate equipment. ATTENTION For Class B - Unintentional Radiators:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. ATTENTION ICES-003 Class B NoticeAvis NMB-003, Class B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme la norme NMB-003 du Canada. ATTENTION Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different form that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help In order to satisfy the FCC RF exposure limit for transmitting devices, a separation distance of 20cm (7.8 inches) or more should be maintained while operating the Sensus SONIXIQ. To ensure compliance, operations at closer than this distance are not recommended. This minimum safe distance is required between personnel and this antenna of this device. RADIATION HAZARD In order to satisfy the ISED RF exposure limit for transmitting devices, a separation distance of 26cm (10.2 inches) or more should be maintained while operating the Sensus SONIXIQ. To ensure compliance, operation at closer than this distance is not recommended. This minimum safe distance is required between personnel and the antenna of this device. Afin de satisfaire la limite dexposition RF pour les appareils de transmission, une distance de sparation de 26cm (10.2 pouces) ou plus doit tre maintenu pendant le fonctionnement du Sensus SONIXIQ. Pour assurer la conformit, un fonctionnement distance infrieure celle est pas recommande. Cette distance minimale de scurit est ncessaire entre le personnel et lantenne de cet appareil. ATTENTION This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. WARNING If you are not sure of the rated power of your radio, contact your Sensus representative or dealer and supply the product model number found on the product label. If you cannot determine the rated power out, then assure 20cm separation from the body to the device. GQG-10004-01 SonixIQ Warnings & Hazards WARNING ATTENTION The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. Class 1, Division 2, Group D T4 Intrinsically Safe/Scurit Intrinsque Type D lithium battery, 3.6 VDC Max. ATTENTION This radio transmitter the Sensus SONIXIQ has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le prsent metteur radio (Sensus SONIXIQ) a t approuv par Industrie Canada pour fonctionner avec les types dantenne numrs ci-dessous et ayant un gain admissible maximal et limpdance requise pour chaque type dantenne. Les types dantenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour lexploitation de lmetteur. Dipole ~3dBi ATTENTION Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation dIndustrie Canada, le prsent metteur radio peut fonctionner avec une antenne dun type et dun gain maximal (ou infrieur) approuv pour lmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention des autres utilisateurs, il faut choisir le type dantenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas lintensit ncessaire ltablissement dune communication satisfaisante. WARNING Substitution of components may impair intrinsic safety. Avertissement: la substitution de composants peut compromettre la Scurit Intrinsque. WARNING There is danger of explosion if batteries are mishandled or incorrectly replaced. On systems with replaceable batteries, replace only with the same manufacturer and type or equivalent type recommended per the instructions provided in the product service manual. Do not disassemble batteries or attempt to recharge them outside the system. Do not dispose of batteries in fire. Dispose of batteries properly in accordance with the manufacturers instructions and local regulations. WARNING DO NOT INCINERATE or subject battery cells to temperatures in excess of 212F. Such treatment can cause cell rupture. WARNING EXPLOSION HAZARD - BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOW TO BE NON-HAZARDOUS. AVERTISSEMENT-RISQUE DEXPLOSION - AFIN DVITER TOUT RISQUE DEXPLOSION, SASSURER QUE LEMPLACEMENT EST DSIGN NON DANGEREUX AVANT DE CHANGER LA BATTERIE. 8601 Six Forks Rd, Ste 700 Raleigh, NC 27615 1-800-638-3748 sensus.com 2018 Sensus. All products purchased and services performed are subject to Sensus terms of sale, available at either sensus.com/TC or 1-800-
638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.