all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.19 MiB | September 22 2015 | |||
1 |
|
Internal Photos | Internal Photos | 1.58 MiB | September 22 2015 | |||
1 |
|
External Photos | External Photos | 715.24 KiB | September 22 2015 | |||
1 |
|
Label | ID Label/Location Info | 359.45 KiB | September 22 2015 | |||
1 |
|
Agents Letter | Cover Letter(s) | 50.30 KiB | September 22 2015 | |||
1 | Antenna Details | Operational Description | September 22 2015 | confidential | ||||
1 | Block Diagram | Block Diagram | September 22 2015 | confidential | ||||
1 |
|
Confidentiality Letter | Cover Letter(s) | 50.87 KiB | September 22 2015 | |||
1 |
|
DoC Attestation Letter | Cover Letter(s) | 51.09 KiB | September 22 2015 | |||
1 | Operating Description | Operational Description | September 22 2015 | confidential | ||||
1 |
|
RF Exposure Report | RF Exposure Info | 82.18 KiB | September 22 2015 | |||
1 | Schematics | Schematics | September 22 2015 | confidential | ||||
1 |
|
Test Report | Test Report | 3.29 MiB | September 22 2015 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 453.27 KiB | September 22 2015 | |||
1 |
|
Tune Up | Parts List/Tune Up Info | 81.52 KiB | September 22 2015 |
1 | User Manual | Users Manual | 1.19 MiB | September 22 2015 |
ADT Pulse Interactive Solutions OC835-ADT
:DWHUSURRI+',3&DPHUD Quick Installation Guide Table of Contents CHAPTER 1 INTRODUCTION ............................................................................ 3 Overview ............................................................................................................... 3 Physical Details ................................................................................................... 4 Package Contents ............................................................................................... 6 CHAPTER 2 BASIC SETUP ................................................................................. 7 Installation ............................................................................................................ 7 CHAPTER 3 ADT PULSE ENROLLMENT ......................................................... 9 Wired Connection to the Gateway Using the Pulse Portal......................... 9 Wireless Connection to the Gateway Using the Pulse Portal .................. 13 Wireless Connection to the TS Base Using the Installer App .................. 17 If the Camera Continually Goes Offline ........................................................ 20 CHAPTER 4 WALL MOUNTING ...................................................................... 21 APPENDIX A SPECIFICATIONS ...................................................................... 23 OC835-ADT Outdoor Day/Night HD Camera ............................................ 23 Regulatory Approvals ...................................................................................... 24 Property of ADT LLC. Information accurate as of published date and is provided as is without warranty of any kind. 2015 ADT LLC dba ADT Security Services. All rights reserved. ADT, the ADT logo, 800 ADT.ASAP and the product/service names listed are marks and/or registered marks of ADT. Unauthorized use is strictly prohibited. Third party marks are property of their respective owners. OC835-ADT-QIG-00 (08/15) 2 OC835-ADT Outdoor HD Camera Installation Guide Chapter 1 Introduction 1 This section provides information about the OC835-ADT Outdoor Day/Night HD Camera's features, components and capabilities. Overview The OC835-ADT is a true outdoor day/night wireless camera with HD resolution, 802.11n Wi-Fi connectivity and Wi-Fi Protected Setup (WPS) support. This camera is intended for use with ADT Pulse. Features x Standalone Design. The camera is a standalone system with built-in CPU and video encoder. It requires only a power source and a connection to the ADT Pulse Gateway or ADT Total Security (TS) Base panel. x Dual Video Support. The OC835-ADT supports H.264 and MJEPG video compression. x Day/Night Switch: With the day/night switching feature, you can view and record images even at night. IR LED Support. The infrared LED can provide illumination for up to 6 meters, providing superior video quality under low-light conditions such as on cloudy days, or in the early morning or evening. x x PIR (Passive Infrared Sensor) Support. The embedded PIR Sensor senses infrared light radiating from human bodies in its field of view. x Built-in Heater. The built-in heater ensures that the camera will continue to operate even in extremely cold outdoor climates. The heater turns on when the temperature falls below 42qF (6qC). Wireless Features x Supports 802.11n Wireless Standard. The 802.11n standard provides backward compatibility with the 802.11b and g standards. x Supports WPS. Wi-Fi Protected Setup (WPS) can simplify the process of connecting the Wireless HD Camera to the wireless network by using the push button configuration. x Wired and Wireless Network. The OC835-ADT can be connected to the Pulse network wirelessly. It can also be hardwired to the network. OC835-ADT Outdoor HD Camera Installation Guide 3 Chapter 1 Introduction Physical Details Front Light Sensor Lens PIR Sensor Figure 1: Front Panel Light Sensor Lens PIR Sensor This is a hardware sensor to detect lux. The lens cannot be adjusted. Please ensure that the lens cover remains clean. This is a Passive Infrared sensor to detect motion. Rear Power LED Network/Wireless LED Network Port DC Power Input WPS/Reset Button Figure 2: Rear Panel 4 OC835-ADT Outdoor HD Camera Installation Guide DC Power Input Power LED
(Green, Amber) Network/Wireless LED
(Green, Amber) Chapter 1 Introduction Connect the supplied 12V power adapter here. Do not use other power adapters; doing so may damage the camera. On (Green). Power on. Off. No power. Blinking (Green). The Power LED blinks during start up for approximately 1 minute. Blinking (Amber). The firmware is being upgraded. On (Amber). The firmware upgrade has failed. On (Green). Network connection is available (wired or wireless). Off. Wired/wireless network is not connected or camera is not sending/receiving data. Blinking (Green). Data is being transmitted or received via the wired/wireless connection. On (Amber). If the LED is on for 5 seconds and then turns off, the WPS function has failed. Blinking (Amber). The WPS connection is active. WPS/Reset Button This button serves two functions on the camera. Network Port x WPS Pin Code Mode. When pressed and held for 5 seconds during the Pulse enrollment process, the camera creates an encryption-secured wireless connection. x Reset. When pressed and held over 15 seconds, the camera reboots and the settings are restored to default values. Use a Micro USB to RJ-45 Adapter Cable (not included) and a standard Ethernet cable (not included) to connect the camera to the Pulse Gateway or TS Base panel. Note:
x Plugging in the Micro USB to RJ-45 Adapter Cable will disable the wireless interface. Only one interface can be active at any time. x The Micro USB to RJ-45 Adapter Cable should only be connected or disconnected when the camera is powered OFF. Attaching or detaching the Micro USB to RJ-45 Adapter Cable while the camera is powered on does NOT switch the interface between wired and wireless. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 5 Chapter 1 Introduction Package Contents The following items are included in the package. Figure 3: Whats in the Box 6 OC835-ADT Outdoor HD Camera Installation Guide 2 Chapter 2 Basic Setup This section provides information on how to assemble and configure the OC835-ADT Outdoor HD Camera. Installation 1. Assemble the Camera Attach the Camera Stand to the camera. 2. Make the Connection Using a Wired Connection If you are using a wired connection to the OC835-ADT, connect a Micro USB to RJ-45 Adapter Cable (not included) to the USB port of the camera. Then use a standard Ethernet cable (not included) to connect to the Pulse Gateway or Total Security (TS) Base panel. Figure 4: Wired Network Connection Using a Wireless Connection The wireless (WPS) connection between the camera and the Pulse Gateway or Total Security (TS) Base panel is performed during the Pulse enrollment. This process is detailed starting on page 13. The Wireless and LAN interfaces cannot be used simultaneously. Making a wired LAN connection disables the wireless interface. NOTE:
3. Power Up Connect the supplied 12V power adapter to the camera and power up. Use only the power adapter provided. Using a different one may cause hardware damage. OC835-ADT Outdoor HD Camera Installation Guide 7 Chapter 2 Basic Setup Use only the power adapter provided. Using a different one can result in hardware damage. Figure 5: Routing the Power Cable The Power LED turns on briefly, and then starts blinking. (The Power LED will continue to blink during startup, which takes about one minute. After startup is completed, the Power LED should remain ON.) 4. Check the LEDs x Power LED. At power up, the Power LED turns on briefly, and then starts blinking, which takes about one minute. After startup has completed, the Power LED remains on. x Network/WPS LED. At power up, the Network/WPS LED is off.
(The Network/WPS LED will flash amber when the camera attempts to connect wirelessly to the Pulse Gateway / TS Base. The Network/WPS LED will turn solid green when the wireless connection is successful.) 5. Enroll the Camera in ADT Pulse This process is described in the next chapter, ADT Pulse Enrollment. 6. Mount the Camera Place the camera in a location near a power source. For mounting on a wall using the mounting plate, see Chapter 4 Wall Mounting on page 21. Mounting Suggestion To get the best video quality for targets at night, make sure that the cameras field of view does not include a large foreground object, such as tabletop or side wall. If installing on a tabletop, place the camera as close to the edge as possible. If installing on a wall, angle the camera so that a minimal portion of the wall is visible. 8 OC835-ADT Outdoor HD Camera Installation Guide Chapter 3 ADT Pulse Enrollment 3 This section provides examples of three different methods for enrolling the OC835-ADT Outdoor HD Camera into the ADT Pulse network. (1) The first method uses a wired connection to enroll the HD Camera to a Gateway via the Pulse Portal. (2) The second method, which uses WPS to wirelessly enroll the HD Camera to a Gateway via the Pulse Portal, is described on page 13. (3) The third method, which uses WPS to wirelessly enroll the HD Camera to an ADT Total Security (TS) Base panel via the TS Installer App, is described on page 17. Wired Connection to the Gateway Using the Pulse Portal 1. Set up the camera, as described in the previous chapter. 2. Open a web browser and in the address bar, enter:
https://Portal.ADTPulse.com. 3. Type your Username and Password, and then click the Sign In button. 4. Click the System tab, and then click the Manage Devices button. OC835-ADT Outdoor HD Camera Installation Guide 9 Chapter 3 ADT Pulse Enrollment 5. In the Manage Devices screen, click Cameras. 6. Click the Add button at the bottom of the screen. 7. On the rear of the camera locate the cameras MAC ID. 10 OC835-ADT Outdoor HD Camera Installation Guide 8. On the Add Camera screen, enter the cameras MAC ID. Do not click CContinue at this time. Chapter 3 ADT Pulse Enrollment 9. Ensure that the camera is connected to the device port of the Gateway using the Micro USB to RJ-45 Adapter Cable / Ethernet cable and connected to the supplied 12VDC power adapter. 10. After the Power and Network LEDs turn on solid green, click Continue. 11. Wait for the camera to add. It could take a few minutes, especially if an upgrade is required. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 11 Chapter 3 ADT Pulse Enrollment 12. Assign the camera a unique name (usually based on the location of the camera) in the Name field, and then click the Save button at the upper right of the screen. 13. The Cameras screen appears, now displaying the added camera. 14. At the top left of the screen, click Go Back. 15. You are returned to the Manage Devices screen. The total number of installed cameras has increased by one. Click Close. 16. Click Close again to confirm. 17. Disconnect the camera from the Gateway and remove from power. 18. Install the camera in its final location. For Wall Mounting, refer to Chapter 4. 12 OC835-ADT Outdoor HD Camera Installation Guide Chapter 3 ADT Pulse Enrollment Wireless Connection to the Gateway Using the Pulse Portal 1. Set up the camera, as described in Chapter 2. 2. Open a web browser and in the address bar, enter:
https://Portal.ADTPulse.com. 3. Type your Username and Password, and then click the Sign In button. 4. Click the System tab, and then click the Manage Devices button. 5. In the Manage Devices screen, click Cameras. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 13 Chapter 3 ADT Pulse Enrollment 6. In the Cameras screen, click the Add Using WPS button at the bottom of the screen. 7. Locate the PIN number located on the label on the rear of the camera and enter that number in the WPS PIN field. 8. Ensure that the camera is powered on, and then click the Continue button to initiate the WPS process. 14 OC835-ADT Outdoor HD Camera Installation Guide The following screen appears. Chapter 3 ADT Pulse Enrollment 9. Press and hold the WPS/RESET button on the camera for 5 seconds to establish a wireless connection. Note: You must complete the WPS connection within 2 minutes or else the process will time out. The time remaining is displayed in the upper left portion of the screen. The Network/WPS LED flashes amber as the Gateway attempts to connect to the camera. The wireless connection is successful when the Network/WPS LED turns solid green. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 15 Chapter 3 ADT Pulse Enrollment 10. When the Camera Details screen appears, showing that the camera has been enrolled, assign the OC835-ADT a unique name (usually based on the location of the camera) in the Name field, and then click Save. The new camera appears in the Cameras list. 11. At the top left of the screen, click Go Back. 12. You are returned to the Manage Devices screen. The total number of installed cameras has increased by one. Click Close. 13. Click Close again to confirm. 14. Disconnect the camera from power. 15. Install the camera in its final location. For Wall Mounting, refer to Chapter 4. 16 OC835-ADT Outdoor HD Camera Installation Guide Chapter 3 ADT Pulse Enrollment Wireless Connection to the TS Base Using the Installer App Note: In ADT Total Security (TS) Systems, the gateway is integrated with the TS Base panel and is not a separate device. 1. Install and configure the camera, as described in the previous chapter. 2. Launch an Internet browser from a computer and log in to the Installer App. 3. Select Pulse Devices. 4. Click Cameras. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 17 Chapter 3 ADT Pulse Enrollment 5. Click the Add Using WPS button, located at the bottom of the screen. 6. Locate the PIN number located on the label on the rear of the camera and enter that number in the WPS PIN field. 7. Ensure that the camera is powered on, and then click the Continue button to initiate the WPS process. 18 OC835-ADT Outdoor HD Camera Installation Guide The following screen appears. Chapter 3 ADT Pulse Enrollment 8. Press and hold the WPS/RESET button on the camera for 5 seconds to establish a wireless connection. The Network/WPS LED flashes amber as the TS Base attempts to connect to the camera. The wireless connection is successful when the Network/WPS LED turns solid green. Note: You must complete the WPS connection within 2 minutes or else the process will time out. The time remaining is displayed in the upper left portion of the screen. 9. When the Camera Details screen appears, showing that the camera has been enrolled, assign the OC835-ADT a unique name (usually based on the location of the camera) in the Name field, and then click Save. OC835-ADT Outdoor Day/Night HD Camera Installation Guide 19 Chapter 3 ADT Pulse Enrollment The Pulse enrollment is complete. The newly-added device appears in the Cameras list. 10. At the top left of the screen, click Go Back. 11. Disconnect the camera from power. 12. Install the camera in its final location. For Wall Mounting, refer to Chapter 4. If the Camera Continually Goes Offline If after enrolling it the camera, it continually goes offline (Power LED blinks continually), the camera will automatically attempt to recover the wireless connection. If the camera cannot recover on its own, take the following measures to re-establish the Wi-Fi connection. 1. Power cycle the camera. 2. If the previous measure fails, move the Pulse Gateway closer to the camera. 3. If the previous measure fails, press the cameras reset button for 15 seconds, and then re-enroll the camera into Pulse. 4. If the previous measure fails, install a Wi-Fi Range Extender model WN3000RPH-2ADPAS. 20 OC835-ADT Outdoor HD Camera Installation Guide Chapter 4 Wall Mounting 4 This section provides details for final mounting of the OC835-ADT Outdoor Day/Night HD Camera. You should ensure that the camera is configured and enrolled in ADT Pulse before permanently mounting it. Mounting Suggestion. To get the best video quality for targets at night, make sure that the cameras field of view does not include a large foreground object, such as tabletop or side wall. If installing on a tabletop, place the camera as close to the edge as possible. If installing on a wall, angle the camera so that a minimal portion of the wall is visible. 11. Unscrew the camera stand and remove it from the camera. 2. Hold the stand at the location where you would like to mount the camera and mark the location of the two mounting holes. 3. Drill two pilot holes on the mounting surface at the marked locations. 4. Align the two mounting holes on the camera stand with the two pilot holes, and mount the stand to the surface using the two screws supplied. Figure 6: Installing the Camera Stand 5. Screw/attach the camera onto the camera stand. Figure 7: Attaching the Camera OC835-ADT Outdoor HD Camera Installation Guide 21 Chapter 4 Wall Mounting 6. Connect the power cable into the back of the camera, and then insert the grommet as shown in the figures below. Figure 8: Attaching the Power Cable Ensure that the grommet is positioned properly to prevent water from entering the camera. 7. Rotate the power input cover to tighten it, providing a watertight seal for the power cable. Figure 9: Securing the Power Cable 8. Plug the adapter end into a power outlet. 9. Adjust the camera to a desired position and secure it firmly. 10. Verify that the camera is active on the wireless network and is recognized by ADT Pulse. Note: If the camera does not re-connect, use of the ADT Wi-Fi extender, part #
WN3000RPH-2ADPAS may be recommended to improve wireless connectivity. 22 OC835-ADT Outdoor HD Camera Installation Guide Appendix A Specifications A OC835-ADT Outdoor Day/Night HD Camera Dimensions W x H x D 2.99 x 2.99 x 1.91 (76mm x 76mm x 48.6mm) Video Compression H.264 and MJPEG Image Resolution Operating Temperature Storage Temperature 16:9 720p (1280x720), 640x360 4:3 XGA (1024x720), VGA (640x480), QVGA (320x240) Mixed Mode (720p, VGA, QVGA) 40qF to 122qF (40qC to 50 C) Heater operation: 42qF to 32qF (6qC to 0 C) 40qF to 158qF (-40qC to 70qC) Network Protocols TCP/IP, HTTP, HTTPS, DHCP, UPnP, NTP, RTCP, DNS Network Interface Wireless Interface 1 RJ-45 LAN connection for Ethernet through Micro USB to RJ-45 Adapter Cable IEEE 802.11n/802.11b/802.11g compatible, WEP 64/128 bit, WPA/WPA2 personal security support Button LEDs IR LEDs 1, WPS/Network 2, Power and Network/WPS 2 Power Adapter 12VDC/1.5A, 100 to 240VAC OC835-ADT Outdoor HD Camera Installation Guide 23
s,usesandc accordance
munication rinapartic adioortelev offandon, efollowingm hereceiving betweenth intoanout canradiate
withthein s.However, cularinstalla visionrecep
,theuseris measures:
gantenna. heequipme tletonacirc sequipmen installedan erferenceto erferencew mfulinterfe turningthe
erferenceby Reorientor creasethe
onnectthe
eiverisconn onsultthed tgenerates ndusedina oradiocomm illnotoccur erencetora equipment yoneofthe rrelocateth separation
equipment
nected.
dealeroran radiofrequ structions,
r,thereisno ation.Ifthis ption,which sencourage uencyenerg maycause
oguarantee sequipment hcanbedet edtotrytoc gyand,if
harmful
ethat
tdoescaus termined
correctthe
se
entandrece cuitdifferen eiver.
ntfromthat ttowhicht the
nexperience edradio/TV Vtechnician
forhelp.
assureconti provedbyth operatethis nectingtoc inuedcomp hepartyres
equipment computero pliance,any
ponsiblefo t.(Example orperiphera
changesor orcomplianc
:useonlys aldevices). rmodificatio cecouldvo hieldedinte onsnotexpr idtheuser'
erfacecable ressly
sauthority
eswhen
sdevicecom owingtwoc mplieswith
conditions:
Part15oft theFCCRul es.Operatio onissubjec cttothe
Thisdevice Thisdevice
seundesire auseharmfu
maynotca ptanyinterf mustaccep edoperation n.
ulinterferen ferencerece nce,and
eived,inclu dinginterfe erencethat
may
This not
inte inte harm byt inte
(cid:576)
In
Co rece
Co
Toa app too con
This follo
(cid:576)
(cid:576) T caus
FCCRadiationExposureStatement
ThisequipmentcomplieswithFCCRFradiationexposurelimitssetforthforan
uncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwitha
minimumdistanceof20centimetersbetweentheradiatorandyourbody.
Thistransmittermustnotbecolocatedoroperatinginconjunctionwithanyother
antennaortransmitter.
CANICES3(B)/NMB3(B)
ThisdevicecomplieswithRSSGENoftheIndustryCanadaRules.Operation
issubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful
interference,and(2)thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
CedispositifestconformelanormeCNRGENd'IndustrieCanadaapplicable
auxappareilsradioexemptsdelicence.Sonfonctionnementestsujetauxdeux
conditionssuivantes:(1)ledispositifnedoitpasproduiredebrouillageprjudiciable,
et(2)cedispositifdoitacceptertoutbrouillagereu,ycomprisunbrouillage
susceptibledeprovoquerunfonctionnementindsirable.
ThisradiotransmitterhasbeenapprovedbyIndustryCanadatooperatewiththe
antennatypeslistedbelowwiththemaximumpermissiblegainandrequired
antennaimpedancearestrictlyprohibitedforusewiththisdevice.
LeprsentmetteurradioatapprouvparIndustrieCanadapourfonctionner
aveclestypesd'antennenumrscidessousetayantungainadmissiblemaximal
et l'impdancerequisepourchaquetyped'antenne.Lestypesd'antennenon
inclusdanscetteliste,oudontlegainestsuprieuraugainmaximalindiqu,sont
strictementinterditspourl'exploitationdel'metteur.
ICRadiationExposureStatement
ThisequipmentcomplieswithICradiationexposurelimitssetforthforan
uncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwith
minimumdistance20cmbetweentheradiatorandyourbody.
Dclarationd'expositionauxradiations:Cetquipementestconformeauxlimites
d'expositionauxrayonnementsICtabliespourunenvironnementnoncontrl.
Cetquipementdoittreinstalletutilisavecunminimumde20cmdedistance
entrelasourcederayonnementetvotrecorps.
1 | Internal Photos | Internal Photos | 1.58 MiB | September 22 2015 |
Compliance Certification Services Inc. Report No.: T150508D07 INTERNAL PHOTOGRAPHS OF EUT A1 - 6 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 7 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 8 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 9 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 10 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 RF IC A1 - 11 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 12 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 Antenna A1 - 13 / 13 Rev. 00
1 | External Photos | External Photos | 715.24 KiB | September 22 2015 |
Compliance Certification Services Inc. Report No.: T150508D07 APPENDIX 1 - PHOTOGRAPHS OF EUT EXTERNAL PHOTOGRAPHS OF EUT A1 - 1 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 2 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 3 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 4 / 13 Rev. 00 Compliance Certification Services Inc. Report No.: T150508D07 A1 - 5 / 13 Rev. 00
1 | Label | ID Label/Location Info | 359.45 KiB | September 22 2015 |
5 3 8 C O A 7 2 5
:
C I
5 3 8 C O 7 2 P
:
D I
C C F
) B
(
3 B M N
/
) B
(
3 S E C I
N A C
5 3 8 C O A 7 2 5
:
C I
5 3 8 C O 7 2 P
:
D I
C C F
) B
(
3 B M N
/
) B
(
3 S E C I
N A C
5 3 8 C O A 7 2 5
:
C I
5 3 8 C O 7 2 P
:
D I
C C F
) B
(
3 B M N
/
) B
(
3 S E C I
N A C
1 | Agents Letter | Cover Letter(s) | 50.30 KiB | September 22 2015 |
BABT TCB DateAugust 24, 2015 FCC ID: P27OC835 Dear Sir or Madam, We, Sercomm Corporation hereby authorize Compliance Certification Services Inc / Sam.Chuang . to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 2016/2/14 Yours Sincerely, Kevin Kuo Sr. Manager / R&D Division Sercomm Corporation TEL: 886-2-2655-3988#2631 FAX: 886-2-2655-7379 E-Mail: kevin_kuo@sercomm.com
1 | Confidentiality Letter | Cover Letter(s) | 50.87 KiB | September 22 2015 |
BABT TCB DateAugust 24, 2015 Confidentiality Request FCC ID: P27OC835 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commissions Rules, Sercomm Corporation hereby requests permanent confidential treatment of information accompanying this application as outlined below:
Common exhibits for which confidentiality is requested are:
Schematics Block Diagrams Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours Sincerely, Kevin Kuo Sr. Manager / R&D Division Sercomm Corporation TEL: 886-2-2655-3988#2631 FAX: 886-2-2655-7379 E-Mail: kevin_kuo@sercomm.com
1 | DoC Attestation Letter | Cover Letter(s) | 51.09 KiB | September 22 2015 |
DateSeptember 9, 2015 Subject: DoC declaration To Whom it may concern, We, as the grantee of this project FCC ID: P27OC835, would like to declare that the composite Portion categorized as computer peripheral has been authorized under the Declaration of Conformity procedures. Brand Name & Model Name of the specified radio equipment:
Sercomm / OC835-ADT FCC ID: P27OC835 Product Name: Waterproof HD IP Camera Regards, Yours Sincerely, Kevin Kuo Sr. Manager / R&D Division Sercomm Corporation TEL: 886-2-2655-3988#2631 FAX: 886-2-2655-7379 E-Mail: kevin_kuo@sercomm.com
1 | RF Exposure Report | RF Exposure Info | 82.18 KiB | September 22 2015 |
Compliance Certification Services Inc. Report No.: T150508D07-MF KDB 447498 D03 IEEE C95.1 47 C.F.R. Part 1, Subpart I, Section 1.1310 47 C.F.R. Part 2, Subpart J, Section 2.1091 RF EXPOSURE REPORT For Waterproof HD IP Camera Model: OC835-ADT Trade Name: Sercomm Issued to 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Sercomm Corporation Issued by Compliance Certification Services Inc. No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.) http://www.ccsrf.com service@ccsrf.com Issued Date: June 2, 2015 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 1 Rev.00 Compliance Certification Services Inc. Report No.: T150508D07-MF Revision History Rev. Issue Date Revisions Effect Page Revised By 00 2015/06/02 Initial Issue ALL Becca Chen This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 2 Rev.00 Compliance Certification Services Inc. Report No.: T150508D07-MF TABLE OF CONTENTS 1. LIMIT .................................................................................................................... 4 2. EUT SPECIFICATION .......................................................................................... 4 3. TEST RESULTS ................................................................................................... 5 4. MAXIMUM PERMISSIBLE EXPOSURE .............................................................. 6 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 3 Rev.00 Compliance Certification Services Inc. Report No.: T150508D07-MF 1. LIMIT According to 15.247(i), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See 1.1307(b)(1) of this chapter. 2. EUT SPECIFICATION EUT Model Waterproof HD IP Camera OC835-ADT RF Module REALTEK Model:
RTL8192EU Model Discrepancy N/A 802.11b/g/n HT20: 2.412GHz ~ 2.462GHz 802.11 n HT40: 2.422GHz ~ 2.452GHz Others Portable (<20cm separation) Mobile (>20cm separation) Others Occupational/Controlled exposure (S = 5mW/cm2) General Population/Uncontrolled exposure
(S=1mW/cm2) 1. PIFA Antenna / P/N: 617210HS 2. PIFA Antenna / P/N: 617210HR 3. PIFA Antenna / P/N: 617210K8 Frequency band
(Operating) Device category Exposure classification Antenna Specification Maximum Average output power Maximum Tune up Power Evaluation applied MPE Evaluation*
SAR Evaluation N/A This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 4 Rev.00 2.4GHz: Antenna Gain :2.14 dBi(Numeric gain:1.64)2.4GHz: Antenna Gain :2.69 dBi(Numeric gain:1.86)2.4GHz: Antenna Gain :2.18 dBi(Numeric gain:1.65)IEEE 802.11b Mode:18.31 dBm(67.764 mW)IEEE 802.11g Mode:16.34 dBm(43.053 mW)IEEE 802.11n HT 20 Mode: 18.24 dBm(66.681 mW)IEEE 802.11n HT 40 Mode: 18.26 dBm(66.988 mW)IEEE 802.11b Mode:18.50 dBm(70.795 mW)IEEE 802.11g Mode:18.00 dBm(63.096 mW)IEEE 802.11n HT 20 Mode: 18.50 dBm(70.795 mW)IEEE 802.11n HT 40 Mode: 18.50 dBm(70.795 mW) Compliance Certification Services Inc. Report No.: T150508D07-MF 3. TEST RESULTS No non-compliance noted. Calculation Given
&
Where E = Field strength in Volts / meter P = Power in Watts G = Numeric antenna gain d = Distance in meters S = Power density in milliwatts / square centimeter Combining equations and re-arranging the terms to express the distance as a function of the remaining variables yields:
Changing to units of mW and cm, using:
Yields P (mW) = P (W) / 1000 and d (cm) = d(m) / 100 Equation 1 Where d = Distance in cm P = Power in mW G = Numeric antenna gain S = Power density in mW / cm2 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 5 Rev.00 dGPE303772ES237730dGPS220796.0100/3771000/30dGPdGPS Compliance Certification Services Inc. Report No.: T150508D07-MF 4. MAXIMUM PERMISSIBLE EXPOSURE Substituting the MPE safe distance using d = 20 cm into Equation 1:
Where P = Power in mW G = Numeric antenna gain S = Power density in mW / cm2 IEEE 802.11b mode:
IEEE 802.11g mode:
IEEE 802.11n HT20 mode:
IEEE 802.11n HT40 mode:
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 6 Rev.00 GPS000199.0Ch.Frq.(MHz)P (mW)Gain (num.)D (cm)Power density in mW / cm2Limit (mW/cm2)6243770.7951.86200.02621Ch.Frq.(MHz)P (mW)Gain (num.)D (cm)Power density in mW / cm2Limit (mW/cm2)11246263.0961.86200.02341Ch.Frq.(MHz)P (mW)Gain (num.)D (cm)Power density in mW / cm2Limit (mW/cm2)6243770.7951.86200.02621Ch.Frq.(MHz)P (mW)Gain (num.)D (cm)Power density in mW / cm2Limit (mW/cm2)9245270.7951.86200.02621
1 | Test Report | Test Report | 3.29 MiB | September 22 2015 |
Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP FCC 47 CFR PART 15 SUBPART C TEST REPORT For Waterproof HD IP Camera Model: OC835-ADT Trade Name: Sercomm Issued to Sercomm Corporation 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Issued by Compliance Certification Services Inc. No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.) http://www.ccsrf.com service@ccsrf.com Issued Date: August 7, 2015 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 / 129 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Revision History Rev. 00 Issue Date August 7, 2015 Revisions Effect Page Revised By Initial Issue ALL Becca Chen Page 2 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ......................................................................................... 4 2. EUT DESCRIPTION ............................................................................................................. 5 3. TEST METHODOLOGY ....................................................................................................... 6 3.1 EUT CONFIGURATION .................................................................................................. 6 3.2 EUT EXERCISE .............................................................................................................. 6 3.3 GENERAL TEST PROCEDURES ................................................................................... 6 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ........................................ 7 3.5 DESCRIPTION OF TEST MODES .................................................................................. 8 4. INSTRUMENT CALIBRATION ............................................................................................. 9 4.1 MEASURING INSTRUMENT CALIBRATION .................................................................. 9 4.2 MEASUREMENT EQUIPMENT USED ............................................................................ 9 4.3 MEASUREMENT UNCERTAINTY ................................................................................ 10 5. FACILITIES AND ACCREDITATIONS ............................................................................... 11 5.1 FACILITIES ................................................................................................................... 11 5.2 EQUIPMENT ................................................................................................................. 11 5.3 TABLE OF ACCREDITATIONS AND LISTINGS ........................................................... 12 6. SETUP OF EQUIPMENT UNDER TEST ............................................................................ 13 6.1 SETUP CONFIGURATION OF EUT .............................................................................. 13 6.2 SUPPORT EQUIPMENT ............................................................................................... 13 7. FCC PART 15.247 REQUIREMENTS ................................................................................ 14 7.1 6DB BANDWIDTH ......................................................................................................... 14 7.2 PEAK POWER .............................................................................................................. 34 7.3 AVERAGE POWER ...................................................................................................... 36 7.4 BAND EDGES MEASUREMENT .................................................................................. 38 7.5 PEAK POWER SPECTRAL DENSITY .......................................................................... 68 7.6 SPURIOUS EMISSIONS ............................................................................................... 88 7.7 RADIATED EMISSIONS ............................................................................................. 107 7.8 POWERLINE CONDUCTED EMISSIONS ................................................................... 124 APPENDIX I PHOTOGRAPHS OF TEST SETUP .................................................................. 127 APPENDIX 1 - PHOTOGRAPHS OF EUT Page 3 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 1. TEST RESULT CERTIFICATION Applicant:
Sercomm Corporation 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Equipment Under Test: Waterproof HD IP Camera Trade Name:
Sercomm Model Number:
OC835-ADT Date of Test:
May 26 ~ August 5, 2015 APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15 Subpart C No non-compliance noted We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10: 2009 and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 15.207, 15.209, 15.247. The test results of this report relate only to the tested sample EUT identified in this report. Approved by:
Reviewed by:
Miller Lee Manager Compliance Certification Services Inc. Angel Cheng Section Manager Compliance Certification Services Inc. Page 4 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 2. EUT DESCRIPTION Product Waterproof HD IP Camera Trade Name Sercomm Model Number OC835-ADT Received Date May 8, 2015 Power Adapter Asian Power Devices Inc. Model: WA-18D12FU I/P: 100-240V, 50-60Hz, 0.5A MAX O/P: 12V, 1.5A Frequency Range 2412 ~ 2462 MHz Transmit Power Modulation Technique Mode 802.11b 802.11g 802.11n Standard-20 MHz 802.11n Standard-40 MHz Frequency Output Power Output Power Range 2412 - 2462 2412 - 2462
(dBm) 20.64 25.62 2412 - 2462 27.67
(W) 0.1159 0.3648 0.5845 2422 - 2452 27.32 0.5389 IEEE 802.11b mode: DSSS (1, 2, 5.5 and 11 Mpbs) IEEE 802.11g mode: OFDM (6, 9, 12, 18, 24, 36, 48 and 54 Mpbs) IEEE 802.11n HT 20 MHz mode Channel mode: OFDM (6.5, 7.2, 13, 14.4, 14.44, 19.5, 21.7, 26, 28.89, 28.9, 39, 43.3, 43.33 52, 57.78, 57.8, 58.5, 65.0, 72.2, 78, 86.67, 104, 115.56, 117, 130, 144.44 Mbps) IEEE 802.11n HT 40 MHz mode: OFDM (13.5, 15, 27, 30, 40.5, 45, 54, 60, 81, 90, 108, 120, 121.5, 135, 150, 162, 180, 216, 240, 243, 270, 300 Mbps) Number of Channels Antenna Specification Remark:
IEEE 802.11b/g mode: 11 Channels IEEE 802.11n HT 20 MHz mode: 11 Channels IEEE 802.11n HT 40 MHz mode: 7 Channels PIFA Antenna 1. P/N: 617210HS, Gain: 2.14dBi 2. P/N: 617210HR, Gain: 2.69dBi 3. P/N: 617210K8, Gain: 2.18dBi 1. The sample selected for test was engineering sample that approximated to production product and was provided by manufacturer. 2. This submittal(s) (test report) is intended for FCC ID: P27OC835 filing to comply with Section 15.207, 15.209 and 15.247 of the FCC Part 15, Subpart C Rules. Page 5 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 3. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.10:
2009 and FCC CFR 47 Part 15.207, 15.209, 15.247 and KDB558074. 3.1 EUT CONFIGURATION The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 3.2 EUT EXERCISE The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C. 3.3 GENERAL TEST PROCEDURES Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 13.1.4.1 of ANSI C63.10 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 13.1.4.1 of ANSI C63.10. Page 6 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency bands listed below:
MHz MHz MHz GHz 0.090 - 0.110 10.495 - 0.505 2.1735 - 2.1905 4.125 - 4.128 4.17725 - 4.17775 4.20725 - 4.20775 6.215 - 6.218 6.26775 - 6.26825 6.31175 - 6.31225 8.291 - 8.294 8.362 - 8.366 8.37625 - 8.38675 8.41425 - 8.41475 16.42 - 16.423 16.69475 - 16.69525 16.80425 - 16.80475 25.5 - 25.67 37.5 - 38.25 73 - 74.6 74.8 - 75.2 108 - 121.94 123 - 138 149.9 - 150.05 156.52475 -
156.52525 156.7 - 156.9 12.29 - 12.293 162.0125 - 167.17 12.51975 - 12.52025 12.57675 - 12.57725 13.36 - 13.41 167.72 - 173.2 240 - 285 322 - 335.4 399.9 - 410 608 - 614 960 - 1240 1300 - 1427 1435 - 1626.5 1645.5 - 1646.5 1660 - 1710 1718.8 - 1722.2 2200 - 2300 2310 - 2390 2483.5 - 2500 2655 - 2900 3260 - 3267 3332 - 3339 3345.8 - 3358 3600 - 4400 4.5 - 5.15 5.35 - 5.46 7.25 - 7.75 8.025 - 8.5 9.0 - 9.2 9.3 - 9.5 10.6 - 12.7 13.25 - 13.4 14.47 - 14.5 15.35 - 16.2 17.7 - 21.4 22.01 - 23.12 23.6 - 24.0 31.2 - 31.8 36.43 - 36.5
(2) 1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. 2 Above 38.6
(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within these frequency bands shall not exceed the limits shown in Section 15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall be demonstrated using measurement instrumentation employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be demonstrated based on the average value of the measured emissions. The provisions in Section 15.35 apply to these measurements. Page 7 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 3.5 DESCRIPTION OF TEST MODES The EUT (model: OC835-ADT) had been tested under operating condition. Software used to control the EUT for staying in continuous transmitting mode was programmed. After verification, all tests were carried out with the worst case test modes as shown below except radiated spurious emission below 1GHz and power line conducted emissions below 30MHz, which worst case was in normal link mode only. The EUT is a 2x2 configuration spatial MIMO (2Tx & 2Rx) without beam forming function that operate in double TX chains and double RX chains. The 2x2 configuration is implemented with two outside TX & RX chains (Chain 0 and 1). IEEE 802.11b mode:
Channel Low (2412MHz), Channel Mid (2437MHz) and Channel High (2462MHz) with 1Mbps data rate were chosen for full testing. IEEE 802.11g mode:
Channel Low (2412MHz), Channel Mid (2437MHz) and Channel High (2462MHz) with 6Mbps data rate were chosen for full testing. IEEE 802.11n HT 20 MHz mode:
Channel Low (2412MHz), Channel Mid (2437MHz) and Channel High (2462MHz) with 6.5Mbps data rate were chosen for full testing. IEEE 802.11n HT 40 MHz mode:
Channel Low (2422MHz), Channel Mid (2437MHz) and Channel High (2452MHz) with 13.5Mbps data rate were chosen for full testing. The field strength of spurious emission was measured in the following position: EUT stand-up position (Z axis), lie-down position (X, Y axis) and laptop mode. The worst emission was found in stand-up position (Z axis) and the worst case was recorded. Page 8 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 4. INSTRUMENT CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is traceable to recognized national standards. 4.2 MEASUREMENT EQUIPMENT USED Equipment Used for Emissions Measurement Remark: Each piece of equipment is scheduled for calibration once a year and Loop Antenna is scheduled for calibration once three years. Conducted Emissions Test Site Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilent E4446A US42510252 11/23/2015 Thermostatic/Hrgrosatic Chamber TAICHY MHG-150LF 930619 10/07/2015 AC Power Source EXTECH 6205 DC Power Supply Power Meter Power Sensor ABM Anritsu Anritsu 8301HD ML2495A MA2411A Spectrum Analyzer ROHDE&SCHWARZ FSV40 1140845 D011531 1012009 0917072 101073 N.C.R N.C.R 06/03/2015 06/03/2015 07/09/2015 Wugu 966 Chamber A Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer EMI Test Receiver Agilent R&S Bilog Antenna Sunol Sciences Horn Antenna EMCO Turn Table Antenna Tower Controller Test S/W CCS CCS CCS E4446A US42510268 ESCI JB3 3117 CC-T-1F CC-A-1F CC-C-1F 100064 A030105 00055165 N/A N/A N/A EZ-EMC (CCS-3A1RE) 01/25/2016 06/04/2016 08/19/2015 01/26/2016 N.C.R N.C.R N.C.R Conducted Emission room # B Name of Equipment Manufacturer EMI Test Receiver LISN LISN R&S R&S Model ESCI ENV216 Serial Number Calibration Due 101073 101054 09/18/2015 06/06/2016 SCHWARZBECK NSLK 8127 8127-541 11/25/2015 Capacitive Voltage Probe FCC F-CVP-1 100185 03/12/2016 Test S/W CCS-3A1-CE Page 9 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 4.3 MEASUREMENT UNCERTAINTY PARAMETER UNCERTAINTY Powerline Conducted Emission 3M Semi Anechoic Chamber / 30M~200M 3M Semi Anechoic Chamber / 200M~1000M 3M Semi Anechoic Chamber / 1G~8G 3M Semi Anechoic Chamber / 8G~18G 3M Semi Anechoic Chamber / 18G~26G 3M Semi Anechoic Chamber / 26G~40G
+/- 1.2575
+/- 4.0138
+/- 3.9483
+/- 2.5975
+/- 2.6112
+/- 2.7389
+/- 2.9683 Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2. Page 10 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 5. FACILITIES AND ACCREDITATIONS 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at No.139, Wugong Rd., Wugu Dist., New Taipei City 24891, Taiwan (R.O.C.) Tel: 886-2-2298-4086 / Fax: 886-2-2298-1470 No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.) Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045 No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841, TAIWAN, R.O.C. Tel: 886-3-324-0332 / Fax: 886-3-324-5235 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. 5.2 EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, bucolical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test Receivers. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, Radio Interference Measuring Apparatus and Measurement Methods. Page 11 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 5.3 TABLE OF ACCREDITATIONS AND LISTINGS Country Agency Scope of Accreditation Logo USA FCC 3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform FCC Part 15 measurements Taiwan TAF FCC MRA: TW1039 LP0002, RTTE01, FCC Method-47 CFR Part 15 Subpart C, D, E, RSS-210, RSS-310 IDA TS SRD, AS/NZS 4268, AS/NZS 4771, TS 12.1 & 12,2, ETSI EN 300 440-1, ETSI EN 300 440-2, ETSI EN 300 328, ETSI EN 300 220-1, ETSI EN 300 220-2, ETSI EN 301 893, ETSI EN 301 489-1/3/7/17 FCC OET Bulletin 65 + Supplement C, EN 50360, EN 50361, EN 50371, RSS 102, EN 50383, EN 50385, EN 50392, IEC 62209, CNS 14958-1, CNS 14959 FCC Method 47 CFR Part 15 Subpart B IEC / EN 61000-3-2, IEC / EN 61000-3-3, IEC / EN 61000-4-2/3/4/5/6/8/11 Canada Industry Canada 3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to perform IC 2324G-1 IC 2324G-2
* No part of this report may be used to claim or imply product endorsement by A2LA or any agency of the US Government. Page 12 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix II for the actual connections between EUT and support equipment. 6.2 SUPPORT EQUIPMENT No Equipment Brand Model Series No. FCC ID Data Cable Power Cord 1 Notebook PC IBM 7663 (T61) L3E9812 N/A N/A AC I/P:
Unshielded, 1.8m DC O/P:
Unshielded, 1.8m with a core Remark:
1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturers requirements and conditions for the intended use. Page 13 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7. FCC PART 15.247 REQUIREMENTS 7.1 6DB BANDWIDTH LIMIT According to 15.247(a)(2), systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6dB bandwidth shall be at least 500 kHz. Test Configuration EUT Spectrum Analyzer TEST PROCEDURE 1. Place the EUT on the table and set it in the transmitting mode. 2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 3. Set the spectrum analyzer as RBW = 300 kHz, VBW = 1000 kHz, Sweep = auto. 4. Mark the peak frequency and 6dB (upper and lower) frequency. 5. Repeat until all the rest channels are investigated. TEST RESULTS No non-compliance noted. Page 14 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Data Test mode: IEEE 802.11b mode Channel Low Mid High Frequency
(MHz) 2412 2437 2462 Test mode: IEEE 802.11g mode Channel Low Mid High Frequency
(MHz) 2412 2437 2462 Bandwidth
(MHz) 10.3334 10.3334 10.3334 Bandwidth
(MHz) 16.8333 16.8333 16.8333 Test mode: IEEE 802.11n HT 20 MHz mode / Chain 0 Channel Low Mid High Frequency
(MHz) 2412 2437 2462 Bandwidth
(MHz) 17.9167 17.8334 17.9167 Test mode: IEEE 802.11n HT 20 MHz mode / Chain 1 Channel Low Mid High Frequency
(MHz) 2412 2437 2462 Bandwidth
(MHz) 17.8334 17.8334 17.8334 Test mode: IEEE 802.11n HT 40 MHz mode / Chain 0 Channel Low Mid High Frequency
(MHz) 2422 2437 2452 Bandwidth
(MHz) 36.4167 36.4167 36.4167 Test mode: IEEE 802.11n HT 40 MHz mode / Chain 1 Channel Low Mid High Frequency
(MHz) 2422 2437 2452 Bandwidth
(MHz) 36.4167 36.5 36.5 Limit
(kHz)
>500 Limit
(kHz)
>500 Limit
(kHz)
>500 Limit
(kHz)
>500 Limit
(kHz)
>500 Limit
(kHz)
>500 Result PASS PASS PASS Result PASS PASS PASS Result PASS PASS PASS Result PASS PASS PASS Result PASS PASS PASS Result PASS PASS PASS Page 15 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Plot IEEE 802.11b mode 6dB Bandwidth (CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2406.8333 2412.5000 2417.1667 2.70 9.73 1.91 3.73 3.73 3.73
-1.03 6.00
-1.82 No. 1 mk3-mk1 Frequency(MHz) Level(dB) 10.3334
-0.79 Page 16 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2431.8333 2437.5000 2442.1667 3.27 10.24 2.43 4.24 4.24 4.24
-0.97 6.00
-1.81 mk3-mk1 10.3334
-0.84 Frequency(MHz) Level(dB) No. 1 Page 17 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2456.8333 2461.5000 2467.1667 2.98 9.81 1.84 3.81 3.81 3.81
-0.83 6.00
-1.97 mk3-mk1 10.3334
-1.14 Frequency(MHz) Level(dB) No. 1 Page 18 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11g mode 6dB Bandwidth (CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2403.5000 2416.1667 2420.3333
-0.18 6.58
-0.80 0.58 0.58 0.58
-0.76 6.00
-1.38 mk3-mk1 16.8333
-0.62 Frequency(MHz) Level(dB) No. 1 Page 19 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2428.5000 2429.2500 2445.3333 0.87 7.33
-0.03 1.33 1.33 1.33
-0.46 6.00
-1.36 No. 1 mk3-mk1 16.8333
-0.9 Frequency(MHz) Level(dB) Page 20 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2453.5000 2454.2500 2470.3333 1.01 7.50
-0.10 1.50 1.50 1.50
-0.49 6.00
-1.60 No. 1 mk3-mk1 16.8333
-1.11 Frequency(MHz) Level(dB) Page 21 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 0 6dB Bandwidth (CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2403.0000 2407.0833 2420.9167
-2.28 4.73
-2.43
-1.27
-1.27
-1.27
-1.01 6.00
-1.16 mk3-mk1 17.9167
-0.15 Frequency(MHz) Level(dB) No. 1 Page 22 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2428.0833 2432.1667 2445.9167
-1.98 4.25
-3.06
-1.75
-1.75
-1.75
-0.23 6.00
-1.31 No. 1 mk3-mk1 17.8334
-1.08 Frequency(MHz) Level(dB) Page 23 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2453.0000 2457.0833 2470.9167
-2.77 4.21
-3.40
-1.79
-1.79
-1.79
-0.98 6.00
-1.61 mk3-mk1 Frequency(MHz) Level(dB) 17.9167
-0.63 No. 1 Page 24 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 1 6dB Bandwidth (CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2403.0833 2407.0833 2420.9167
-2.21 4.21
-2.95
-1.79
-1.79
-1.79
-0.42 6.00
-1.16 mk3-mk1 Frequency(MHz) Level(dB) 17.8334
-0.74 No. 1 Page 25 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2428.0833 2432.1667 2445.9167
-1.02 5.22
-2.05
-0.78
-0.78
-0.78
-0.24 6.00
-1.27 mk3-mk1 Frequency(MHz) Level(dB) 17.8334
-1.03 No. 1 Page 26 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2453.0833 2457.0833 2470.9167
-1.34 5.10
-2.21
-0.90
-0.90
-0.90
-0.44 6.00
-1.31 mk3-mk1 Frequency(MHz) Level(dB) 17.8334
-0.87 No. 1 Page 27 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 0 6dB Bandwidth (CH Low) No. 1 No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2403.8333 2428.6667 2440.2500
-2.53 3.95
-2.28
-2.05
-2.05
-2.05
-0.48 6.00
-0.23 mk3-mk1 Frequency(MHz) Level(dB) 36.4167 0.25 Page 28 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2418.8333 2434.8333 2455.2500
-1.94 4.47
-1.95
-1.53
-1.53
-1.53
-0.41 6.00
-0.42 No. 1 mk3-mk1 Frequency(MHz) Level(dB) 36.4167
-0.01 Page 29 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. 1 No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2433.8333 2449.9167 2470.2500
-2.37 3.73
-2.75
-2.27
-2.27
-2.27
-0.10 6.00
-0.48 mk3-mk1 Frequency(MHz) Level(dB) 36.4167
-0.38 Page 30 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 1 6dB Bandwidth (CH Low) No. 1 No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2433.8333 2449.8333 2470.2500
-1.59 4.67
-1.46
-1.33
-1.33
-1.33
-0.26 6.00
-0.13 mk3-mk1 Frequency(MHz) Level(dB) 36.4167 0.13 Page 31 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH Mid) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2418.8333 2434.9167 2455.3333
-2.74 3.76
-2.91
-2.24
-2.24
-2.24
-0.50 6.00
-0.67 mk3-mk1 Frequency(MHz) Level(dB) 36.5
-0.17 No. 1 Page 32 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 6dB Bandwidth (CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 3 2403.8333 2428.6667 2440.3333
-2.06 4.74
-1.97
-1.26
-1.26
-1.26
-0.80 6.00
-0.71 No. 1 mk3-mk1 Frequency(MHz) Level(dB) 36.5 0.09 Page 33 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.2 PEAK POWER LIMIT The maximum peak output power of the intentional radiator shall not exceed the following:
1. According to 15.247(b)(3), for systems using digital modulation in the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz: 1 Watt. 2. According to 15.247(b)(4), the conducted output power limit specified in paragraph (b) of this section is based on the use of antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values in paragraphs
(b)(1), (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi. Test Configuration EUT Power Meter Power Sensor TEST PROCEDURE The transmitter output is connected to the Power Meter. The Power Meter is set to the peak power detection. Page 34 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Data Test mode: IEEE 802.11b mode Frequency Output Power Output Power
(MHz) 2412 2437 2462
(dBm) 20.64 20.43 20.20
(W) 0.1159 Limit
(W) Result PASS 0.1104 1.00 PASS 0.1047 PASS Test mode: IEEE 802.11g mode Frequency Output Power Output Power
(MHz) 2412 2437 2462
(dBm) 25.62 25.51 25.60
(W) 0.3648 Limit
(W) Result PASS 0.3556 1.00 PASS 0.3631 PASS Channel Low Mid High Channel Low Mid High Test mode: IEEE 802.11n HT 20 MHz mode Channel Frequency
(MHz) Low Mid High 2412 2437 2462 Chain 0 Chain 1 Total Output Output Power Output Power
(dBm) 24.92 25.12 24.68
(dBm) 24.07 24.14 24.08 Power
(dBm) 27.53 27.67 27.40 Output Power
(W) Limit
(W) 0.5657 Result PASS 0.5845 1.00 PASS 0.5496 PASS Test mode: IEEE 802.11n HT 40 MHz mode Channel Frequency
(MHz) Low Mid High 2422 2437 2452 Remark:
Chain 0 Chain 1 Total Output Output Power Output Power
(dBm) 24.31 24.51 24.35
(dBm) 24.11 24.09 24.22 Power
(dBm) 27.22 27.32 27.30 Output Power
(W) Limit
(W) 0.5274 Result PASS 0.5389 1.00 PASS 0.5365 PASS 1. Total Output Power (w) = Chain 0 (10^(Output Power /10)/1000)+ Chain 1 (10^(Output Power /10)/1000) Page 35 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.3 AVERAGE POWER LIMIT None; for reporting purposes only. Test Configuration EUT Power Meter Power Sensor TEST PROCEDURE The transmitter output is connected to the Power Meter. The Power Meter is set to the avg power detection. TEST RESULTS No non-compliance noted. Page 36 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Data Test mode: IEEE 802.11b mode Channel Low Mid High Frequency Output Power Output Power
(MHz) 2412 2437 2462
(dBm) 18.23 18.31 18.01
(W) 0.0665 0.0678 0.0632 Test mode: IEEE 802.11g mode Channel Low Mid High Frequency Output Power Output Power
(MHz) 2412 2437 2462
(dBm) 16.24 16.11 16.34
(W) 0.0421 0.0408 0.0431 Test mode: IEEE 802.11n HT 20 MHz mode Channel Frequency
(MHz) Low Mid High 2412 2437 2462 Chain 0 Chain 1 Total Output Output Power Output Power
(dBm) 15.02 15.25 15.13
(dBm) 15.03 15.21 15.28 Power
(dBm) 18.04 18.24 18.22 Output Power
(W) 0.0636 0.0667 0.0663 Test mode: IEEE 802.11n HT 40 MHz mode Channel Frequency
(MHz) Low Mid High 2422 2437 2452 Chain 0 Chain 1 Total Output Output Power Output Power
(dBm) 15.12 15.38 15.28
(dBm) 15.01 15.1 15.21 Power
(dBm) 18.08 18.25 18.26 Output Power
(W) 0.0642 0.0669 0.0669 Remark: Total Output Power (w) = Chain 0 (10^(Output Power /10)/1000)+ Chain 1 (10^(Output Power /10)/1000) Page 37 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.4 BAND EDGES MEASUREMENT LIMIT According to 15.247(d), in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see Section 15.205(c)). Test Configuration For Radiated Spectrum Analyzer For Conducted EUT Page 38 Rev. 00 Spectrum analyzer Horn antenna 3m 4m 1m Turntable EUT 0.8m Antenna tower Pre-amp Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP TEST PROCEDURE For Radiated 1. The EUT is placed on a turntable, which is 0.8m above the ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest emission. 4. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the emission:
(a) PEAK: RBW=VBW=3MHz / Sweep=AUTO
(b) AVERAGE: RBW=1MHz, if duty cycle98%, VBW=10Hz. if duty cycle<98% VBW=1/T. IEEE 802.11b mode: 98%, VBW=10Hz IEEE 802.11g mode: 98%, VBW=10Hz IEEE 802.11n HT 20 MHz mode: 98%, VBW=10Hz IEEE 802.11n HT 40 MHz mode: 98%, VBW=10Hz 5. Repeat the procedures until all the PEAK and AVERAGE versus POLARIZATION are measured. For Conducted Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna port conducted emissions meet the specified limit and to identify any spurious signals that require further investigation or measurements on the radiated emissions site. The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100 kHz. The video bandwidth is set to 100 kHz. TEST RESULTS Refer to attach spectrum analyzer data chart. Page 39 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11b mode / CH Low) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2387.760 55.25 2387.760 44.68
-2.51
-2.51 52.74 74.00
-21.26 100 42.17 54.00
-11.83 100 111 111 peak AVG 1 2 Page 40 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2387.680 60.06 2387.680 50.26
-2.51
-2.51 57.55 74.00
-16.45 100 358 peak 47.75 54.00
-6.25 100 358 AVG 1 2 Page 41 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11b mode / CH High) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark 1 2
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2486.536 53.39 2486.536 40.36
-1.96
-1.96 51.43 74.00
-22.57 100 137 peak 38.40 54.00
-15.60 100 137 AVG Page 42 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2486.256 58.23 2486.256 46.49
-1.97
-1.97 56.26 74.00
-17.74 100 284 peak 44.52 54.00
-9.48 100 284 AVG 1 2 Page 43 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11g mode / CH Low) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2384.880 63.73 2384.880 47.52
-2.54
-2.54 61.19 74.00
-12.81 100 44.98 54.00
-9.02 100 325 325 peak AVG 1 2 Page 44 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2385.200 60.74 2385.200 43.84
-2.53
-2.53 58.21 74.00
-15.79 100 318 peak 41.31 54.00
-12.69 100 318 AVG 1 2 Page 45 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11g mode / CH High) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2484.853 63.38 2484.853 45.64
-1.98
-1.98 61.40 74.00
-12.60 100 43.66 54.00
-10.34 100 13 13 peak AVG 1 2 Page 46 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2483.500 67.24 2483.500 49.15
-1.99
-1.99 65.25 74.00
-8.75 100 240 peak 47.16 54.00
-6.84 100 240 AVG 1 2 Page 47 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11n HT 20 MHz mode / CH Low) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark 1 2
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2388.800 62.74
-2.50 60.24 74.00
-13.76 100 343 peak 2388.800 45.41
-2.50 42.91 54.00
-11.09 100 343 AVG Page 48 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2389.840 63.20 2389.840 45.29
-2.49
-2.49 60.71 74.00
-13.29 100 42.80 54.00
-11.20 100 13 13 peak AVG 1 2 Page 49 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11n HT 20 MHz mode / CH High) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark 1 2
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2486.569 59.48
-1.96 57.52 74.00
-16.48 100 153 peak 2486.569 43.01
-1.96 41.05 54.00
-12.95 100 153 AVG Page 50 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2484.374 62.86 2484.374 45.86
-1.99
-1.99 60.87 74.00
-13.13 100 43.87 54.00
-10.13 100 21 21 peak AVG 1 2 Page 51 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11n HT 40 MHz mode / CH Low) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark 1 2
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2383.200 59.39
-2.55 56.84 74.00
-17.16 100 313 peak 2383.200 46.94
-2.55 44.39 54.00
-9.61 100 313 AVG Page 52 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2384.400 62.64 2384.400 49.14
-2.54
-2.54 60.10 74.00
-13.90 100 284 peak 46.60 54.00
-7.40 100 284 AVG 1 2 Page 53 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Band Edges (IEEE 802.11n HT 40 MHz mode / CH High) Polarity: Vertical No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2484.771 60.25 2484.771 46.39
-1.98
-1.98 58.27 74.00
-15.73 100 215 peak 44.41 54.00
-9.59 100 215 AVG 1 2 Page 54 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Polarity: Horizontal No. Frequency Reading Correct Result Limit Margin Height Degree Remark
(MHz)
(dBuV) Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
(cm)
( ) 2483.566 62.99 2483.566 49.14
-1.99
-1.99 61.00 74.00
-13.00 100 47.15 54.00
-6.85 100 274 274 peak AVG 1 2 Page 55 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Plot Conducted Band Edges (IEEE 802.11b mode / CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2400.0000 2412.5000
-29.79 7.99
-12.01
-12.01
-17.78 20.00 Page 56 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11b mode / CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2461.5000 2488.5000 7.98
-48.97
-12.02
-12.02 20.00
-36.95 Page 57 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11g mode / CH Low) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2400.0000 2416.1250
-31.82 1.23
-18.77
-18.77
-13.05 20.00 Page 58 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11g mode / CH High) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2454.2500 2484.1250 1.97
-44.88
-18.03
-18.03 20.00
-26.85 Page 59 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 20 MHz mode / CH Low / Chain 0) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2400.0000 2409.1250
-31.99
-0.33
-20.33
-20.33
-11.66 20.00 Page 60 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 20 MHz mode / CH High / Chain 0) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2459.1250 2483.5000
-0.78
-46.66
-20.78
-20.78 20.00
-25.88 Page 61 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 20 MHz mode / CH Low / Chain 1) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2399.8750 2409.1250
-33.68
-0.66
-20.66
-20.66
-13.02 20.00 Page 62 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 20 MHz mode / CH High / Chain 1) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2459.1250 2484.5000 0.34
-46.95
-19.66
-19.66 20.00
-27.29 Page 63 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 40 MHz mode / CH Low / Chain 0) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2400.0000 2414.2500
-34.33
-3.63
-23.63
-23.63
-10.70 20.00 Page 64 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 40 MHz mode / CH High / Chain 0 ) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2455.5000 2484.5000
-4.17
-42.66
-24.17
-24.17 20.00
-18.49 Page 65 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 40 MHz mode / CH Low / Chain 1) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2400.0000 2414.2500
-35.14
-3.28
-23.28
-23.28
-11.86 20.00 Page 66 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Conducted Band Edges (IEEE 802.11n HT 40 MHz mode / CH High / Chain 1 ) No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2454.1250 2485.1250
-3.29
-43.01
-23.29
-23.29 20.00
-19.72 Page 67 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.5 PEAK POWER SPECTRAL DENSITY LIMIT 1. According to 15.247(e), for digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. 2. According to 15.247(f), the digital modulation operation of the hybrid system, with the frequency hopping turned off, shall comply with the power density requirements of paragraph (d) of this section. Test Configuration EUT Spectrum Analyzer TEST PROCEDURE 1. Place the EUT on the table and set it in transmitting mode. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 2. Set the spectrum analyzer as RBW=10kHz,VBW=100kHz,Span=1.5 times the DTS bandwidth, Sweep time= auto 3. Record the max reading. 4. Repeat the above procedure until the measurements for all frequencies are completed. TEST RESULTS No non-compliance noted. Page 68 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Data Test mode: IEEE 802.11b mode Channel Low Mid High Frequency
(MHz) 2412 2437 2462 PPSD
(dBm) Limit
(dBm)
-1.67
-1.41
-1.76 8.00 Test mode: IEEE 802.11g mode Channel Low Mid High Frequency
(MHz) 2412 2437 2462 PPSD
(dBm) Limit
(dBm)
-6.30
-5.46
-5.67 8.00 Result PASS PASS PASS Result PASS PASS PASS Test mode: IEEE 802.11n HT 20 MHz mode Channel Frequency
(MHz) Chain 0 PPSD
(dBm) Chain 1 PPSD
(dBm) Low Mid High 2412 2437 2462
-7.16
-7.25
-7.49
-7.62
-6.61
-6.49 PPSD
(dBm) Limit
(dBm)
-4.37
-3.91 8.00
-3.95 nTest mode: IEEE 802.11n HT 40 MHz mode Channel Frequency
(MHz) Low Mid High 2422 2437 2452 Chain 0 PPSD
(dBm) Chain 1 PPSD
(dBm)
-9.46
-9.58
-9.88
-8.73
-9.25
-9.97 PPSD
(dBm) Limit
(dBm)
-6.07
-6.40 8.00
-6.91 Result PASS PASS PASS Result PASS PASS PASS Remark: 1. Total PPSD (dBm) = 10*LOG(10^(Chain 0 PPSD / 10)+10^(Chain 1 PPSD /10)) Page 69 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Plot IEEE 802.11b mode PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2412.6750
-1.67 8.00
-9.67 Page 70 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2437.6750
-1.41 8.00
-9.41 Page 71 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2462.6750
-1.76 8.00
-9.76 Page 72 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11g mode PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2419.8000
-6.30 8.00
-14.30 Page 73 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2431.0333
-5.46 8.00
-13.46 Page 74 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2454.8333
-5.67 8.00
-13.67 Page 75 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 0 PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2418.5000
-7.16 8.00
-15.16 Page 76 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2430.3667
-7.25 8.00
-15.25 Page 77 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2455.3667
-7.49 8.00
-15.49 Page 78 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 1 PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2409.8667
-7.62 8.00
-15.62 Page 79 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2430.3667
-6.61 8.00
-14.61 Page 80 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2459.8667
-6.49 8.00
-14.49 Page 81 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 0 PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2425.3333
-9.46 8.00
-17.46 Page 82 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2429.1333
-9.58 8.00
-17.58 Page 83 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2455.3333
-9.88 8.00
-17.88 Page 84 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 1 PPSD (CH Low) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2425.3333
-8.73 8.00
-16.73 Page 85 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH Mid) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2440.3333
-9.25 8.00
-17.25 Page 86 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP PPSD (CH High) No. 1 Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 2435.3333
-9.97 8.00
-17.97 Page 87 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.6 SPURIOUS EMISSIONS 7.6.1 Conducted Measurement LIMIT According to 15.247(d), in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see Section 15.205(c)). Test Configuration EUT Spectrum Analyzer TEST PROCEDURE Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna port conducted emissions meet the specified limit and to identify any spurious signals that require further investigation or measurements on the radiated emissions site. The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100 kHz. The video bandwidth is set to 100 kHz. Measurements are made over the 30MHz to 25GHz range with the transmitter set to the lowest, middle, and highest channels. TEST RESULTS No non-compliance noted. Page 88 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Plot IEEE 802.11b mode CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 4824.2400
-47.09
-38.86
-11.51
-11.51
-35.58
-27.35 Page 89 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2352.2100 4874.1800
-55.35
-39.86
-11.19
-11.19
-44.16
-28.67 Page 90 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2352.2100 4924.1200
-56.18
-39.77
-11.44
-11.44
-44.74
-28.33 Page 91 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11g mode CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 25000.0000
-43.97
-47.09
-18.49
-18.49
-25.48
-28.60 Page 92 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 4874.1800
-53.42
-48.62
-17.73
-17.73
-35.69
-30.89 Page 93 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 25000.0000
-55.44
-48.56
-17.63
-17.63
-37.81
-30.93 Page 94 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 0 CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24975.0300
-47.16
-48.48
-19.91
-19.91
-27.25
-28.57 Page 95 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2352.2100 24250.9000
-55.90
-48.55
-20.41
-20.41
-35.49
-28.14 Page 96 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2327.2400 25000.0000
-55.53
-48.48
-20.47
-20.47
-35.06
-28.01 Page 97 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 20 MHz mode / Chain 1 CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24900.1200
-50.42
-48.27
-20.53
-20.53
-29.89
-27.74 Page 98 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2352.2100 23601.6800
-57.15
-48.41
-19.41
-19.41
-37.74
-29.00 Page 99 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24225.9300
-56.01
-48.29
-19.59
-19.59
-36.42
-28.70 Page 100 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 0 CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24925.0900
-43.51
-48.70
-23.34
-23.34
-20.17
-25.36 Page 101 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24450.6600
-51.48
-48.67
-22.98
-22.98
-28.50
-25.69 Page 102 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 30.0000 2502.0300
-54.74
-47.41
-23.53
-23.53
-31.21
-23.88 Page 103 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP IEEE 802.11n HT 40 MHz mode / Chain 1 CH Low No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24975.0300
-45.11
-47.76
-22.64
-22.64
-22.47
-25.12 Page 104 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH Mid No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 24950.0600
-53.76
-48.36
-23.64
-23.64
-30.12
-24.72 Page 105 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP CH High No. Frequency(MHz) Result(dBm) Limit(dBm) Margin(dBm) 1 2 2377.1800 2502.0300
-55.39
-46.96
-22.81
-22.81
-32.58
-24.15 Page 106 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.7 RADIATED EMISSIONS LIMIT 1. According to 15.209(a), except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table:
Frequency Field Strength Measurement Distance
(MHz) 30-88 88-216 216-960 Above 960
(V/m) 100*
150*
200*
500
(m) 3 3 3 3 Remark: Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241. 2. In the emission table above, the tighter limit applies at the band edges. Frequency
(MHz) 30-88 88-216 216-960 Above 960 Field Strength
(V/m at 3-meter) Field Strength
(dBV/m at 3-meter) 100 150 200 500 40 43.5 46 54 Page 107 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Configuration 9kHz ~ 30MHz 30MHz ~ 1GHz Page 108 Rev. 00 Spectrum / Receiver 3m 1m Turntable EUT 0.8m Loop antenna Reference ground plane Spectrum analyzer 3m 4m 1m Turntable EUT 0.8m Antenna tower Reference ground plane Bi-log antenna Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Above 1 GHz Page 109 Rev. 00 Spectrum analyzer Horn antenna 3m 4m 1m Turntable EUT 0.8m Antenna tower Pre-amp Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP TEST PROCEDURE 1. The EUT is placed on a turntable, which is 1.5m above ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest emissions. 4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 5. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. 6. Set the spectrum analyzer in the following setting as:
Below 1GHz:
RBW=100kHz / VBW=300kHz / Sweep=AUTO Above 1GHz:
(a) PEAK: RBW=VBW=10MHz / Sweep=AUTO
(b) AVERAGE: RBW=10Hz, if duty cycle98%, VBW=1Hz. if duty cycle<98% VBW=1/T. IEEE 802.11b mode: 98%, VBW=10Hz IEEE 802.11g mode: 98%, VBW=10Hz IEEE 802.11n HT 20 MHz mode: 98%, VBW=10Hz IEEE 802.11n HT 40 MHz mode: 98%, VBW=10Hz 7. Repeat above procedures until the measurements for all frequencies are complete. TEST RESULTS No non-compliance noted. Page 110 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Below 1GHz Operation Mode: Normal Link Test Date:
August 5, 2015 Temperature:
27C Humidity:
53% RH Tested by:
Jason Lu Polarity:
Ver. / Hor. Frequency
(MHz) Reading
(dBuV) 232.7300 46.57 390.8400 41.01 499.4800 40.14 624.6100 38.01 763.3200 34.27 846.7400 34.02 177.4400 53.33 299.6600 50.30 412.1800 44.23 624.6100 39.08 755.5600 38.86 846.7400 34.57 Remark:
Correction Factor
(dB/m)
-16.67
-11.92
-9.25
-7.17
-4.81
-3.83
-17.21
-14.25
-11.33
-7.17
-4.87
-3.83 Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 29.90 29.09 30.89 30.84 29.46 30.19 36.12 36.05 32.90 31.91 33.99 30.74 46.00 46.00 46.00 46.00 46.00 46.00 43.50 46.00 46.00 46.00 46.00 46.00
-16.10
-16.91
-15.11
-15.16
-16.54
-15.81
-7.38
-9.95
-13.10
-14.09
-12.01
-15.26 Peak Peak Peak Peak Peak Peak peak peak peak peak peak peak V V V V V V H H H H H H 1. Measuring frequencies from 30 MHz to the 1GHz. 2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an instrument using peak/quasi-peak detector mode. 3. Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or as required by the applicant. 4. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 5. Margin (dB) = Result (dBuV/m) Limit (dBuV/m). Page 111 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Above 1 GHz Operation Mode: TX / IEEE 802.11b / CH Low Test Date: July 18, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1576.000 55.04 4825.000 50.59 4825.000 46.67 Correction Factor
(dB/m)
-5.80 5.10 5.10 N/A 1544.000 49.99 4750.000 41.19
-5.96 4.90 N/A Remark:
Tested by: Andy Shi Polarity:
Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Remark Ant. Pol.
(H/V) Margin
(dB)
-24.76
-18.31
-2.23 74.00 74.00 54.00 peak peak peak 74.00 74.00
-29.97
-27.91 peak peak 49.24 55.69 51.77 44.03 46.09 V V V H H 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 112 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11b / CH Mid Test Date:
July 18, 2015 Temperature:
27C Humidity:
53 % RH Tested by: Andy Shi Polarity:
Ver. / Hor. Remark Ant. Pol.
(H/V) Frequency
(MHz) Reading
(dBuV) 1178.000 55.23 Correction Factor
(dB/m)
-7.32 4875.000 45.77 5.24 Result Limit
(dBuV/m)
(dBuV/m) 47.91 51.01 74.00 74.00 Margin
(dB)
-26.09
-22.99 N/A peak peak 1722.000 50.47 4875.000 44.99
-5.04 5.24 45.43 50.23 74.00 74.00
-28.57
-23.77 peak peak N/A Remark:
V V H H 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 113 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11b / CH High Test Date:
July 18, 2015 Temperature:
27C Humidity:
53 % RH Tested by: Andy Shi Polarity:
Ver. / Hor. Remark Ant. Pol.
(H/V) Frequency
(MHz) Reading
(dBuV) 1588.000 54.08 Correction Factor
(dB/m)
-5.73 4925.000 45.03 5.37 Result Limit
(dBuV/m)
(dBuV/m) 48.35 50.40 74.00 74.00 Margin
(dB)
-25.65
-23.60 N/A peak peak 1778.000 49.76 4925.000 44.82
-4.75 5.37 45.01 50.19 74.00 74.00
-28.99
-23.81 peak peak N/A Remark:
V V H H 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 114 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11g / CH Low Test Date:
August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1590.000 57.12 Correction Factor
(dB/m)
-5.72 N/A Tested by:
Jason Lu Polarity:
Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 51.40 74.00
-22.60 peak V 1584.000 54.19
-5.75 48.44 74.00
-25.56 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 115 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11g / CH Mid Test Date:
August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1938.000 50.84 Correction Factor
(dB/m)
-3.92 N/A Tested by:
Jason Lu Polarity:
Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 46.92 74.00
-27.08 peak V 1580.000 54.48
-5.78 48.70 74.00
-25.30 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 116 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11g / CH High Test Date:
August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1978.000 50.64 Correction Factor
(dB/m)
-3.71 N/A Tested by:
Jason Lu Polarity:
Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 46.93 74.00
-27.07 peak V 1596.000 54.42
-5.69 48.73 74.00
-25.27 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 117 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 20 MHz mode / CH Low Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1936.000 51.63 Correction Factor
(dB/m)
-3.93 N/A Tested by: Jason Lu Polarity: Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 47.70 74.00
-26.30 peak V 1584.000 53.46
-5.75 47.71 74.00
-26.29 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 118 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 20 MHz mode / CH Mid Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1798.000 51.92 Correction Factor
(dB/m)
-4.65 N/A Tested by: Jason Lu Polarity:
Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 47.27 74.00
-26.73 peak V 1584.000 52.95
-5.75 47.20 74.00
-26.80 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 119 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 20 MHz mode / CH High Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1848.000 50.49 Correction Factor
(dB/m)
-4.39 N/A Tested by: Jason Lu Polarity: Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 46.10 74.00
-27.90 peak V 1794.000 53.24
-4.67 48.57 74.00
-25.43 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 120 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 40 MHz mode / CH Low Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Tested by: Jason Lu Polarity: Ver. / Hor. Remark Ant. Pol.
(H/V) Frequency
(MHz) Reading
(dBuV) 1918.000 50.65 Correction Factor
(dB/m)
-4.02 4845.000 41.19 5.15 Result Limit
(dBuV/m)
(dBuV/m) 46.63 46.34 74.00 74.00 Margin
(dB)
-27.37
-27.66 N/A peak peak 1584.000 54.59 4835.000 39.82
-5.75 5.13 48.84 44.95 74.00 74.00
-25.16
-29.05 peak peak N/A Remark:
V V H H 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 121 Rev. 00 H H Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 40 MHz mode / CH Mid Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1798.000 51.99 Correction Factor
(dB/m)
-4.65 N/A Tested by: Jason Lu Polarity: Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 47.34 74.00
-26.66 peak V 1584.000 54.77 4755.000 39.50
-5.75 4.91 49.02 44.41 74.00 74.00
-24.98
-29.59 peak peak N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 122 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Operation Mode: TX / IEEE 802.11n HT 40 MHz mode / CH High Test Date: August 5, 2015 Temperature:
27C Humidity:
53 % RH Frequency
(MHz) Reading
(dBuV) 1812.000 51.24 Correction Factor
(dB/m)
-4.57 N/A Tested by: Jason Lu Polarity: Ver. / Hor. Result Limit
(dBuV/m)
(dBuV/m) Margin
(dB) Remark Ant. Pol.
(H/V) 46.67 74.00
-27.33 peak V 1584.000 54.23
-5.75 48.48 74.00
-25.52 peak H N/A Remark:
1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded
(ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. 6. Margin (dB) = Remark result (dBuV/m) Average limit (dBuV/m). Page 123 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP 7.8 POWERLINE CONDUCTED EMISSIONS LIMIT According to 15.207(a), except as shown in paragraphs (b) and (c) of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit applies at the boundary between the frequency ranges. Frequency Range
(MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Limits
(dBV) Quasi-peak 66 to 56*
56 60 Average 56 to 46*
46 50
* Decreases with the logarithm of the frequency. Test Configuration See test photographs attached in Appendix II for the actual connections between EUT and support equipment. TEST PROCEDURE 1. The EUT was placed on a table, which is 0.8m above ground plane. 2. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 3. Repeat above procedures until all frequency measured were complete. Page 124 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP TEST RESULTS The initial step in collecting conducted data is a spectrum analyzer peak scan of the measurement range. Significant peaks are then marked as shown on the following data page, and these signals are then quasi-peaked. Test Data Operation Mode:
Normal Link Test Date:
May 26, 2015 Temperature:
26C Tested by:
David Shu Humidity:
60% RH Freq.
(MHz) QP AV Reading
(dBuV) Reading
(dBuV) Corr. factor
(dB/m) QP AV Result
(dBuV/m Result
(dBuV/m QP Limit
(dBuV) AV Limit
(dBuV)
)
) QP AV Margin Margin Note
(dB)
(dB) 0.1646 34.48 17.91 9.61 44.09 27.52 48.00 55.23
-3.91
-27.71 0.1939 29.68 11.74 9.62 39.30 21.36 48.00 53.87
-8.70
-32.51 0.2512 28.24 19.83 9.62 37.86 29.45 48.00 51.72
-10.14
-22.27 5.1060 28.41 20.68 9.76 38.17 30.44 48.00 50.00
-9.83
-19.56 5.7135 29.66 21.67 9.78 39.44 31.45 48.00 50.00
-8.56
-18.55 6.2117 30.27 22.06 9.78 40.05 31.84 48.00 50.00
-7.95
-18.16 0.1612 32.81 13.89 9.66 42.47 23.55 65.40 55.40
-22.93
-31.85 0.1723 32.52 16.90 9.66 42.18 26.56 64.84 54.85
-22.66
-28.29 0.1795 29.70 11.51 9.67 39.37 21.18 64.50 54.51
-25.13
-33.33 5.5113 24.66 16.18 9.82 34.48 26.00 60.00 50.00
-25.52
-24.00 6.0815 25.88 17.22 9.83 35.71 27.05 60.00 50.00
-24.29
-22.95 6.7734 25.45 17.27 9.85 35.30 27.12 60.00 50.00
-24.70
-22.88 L1 L1 L1 L1 L1 L1 L2 L2 L2 L2 L2 L2 Remark:
1. Measuring frequencies from 0.15 MHz to 30MHz. 2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with an instrument using Quasi-peak detector and average detector. 3. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10 kHz; the IF bandwidth of Test Receiver between 0.15MHz and 30MHz was 9 kHz;
4. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line) Page 125 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Test Plots Conducted emissions (Line 1) Conducted emissions (Line 2) Page 126 Rev. 00
1 | Test Setup Photos | Test Setup Photos | 453.27 KiB | September 22 2015 |
Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP APPENDIX I PHOTOGRAPHS OF TEST SETUP Conducted Emissions Setup Photos Page 127 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Radiated Emissions Setup Photos Page 128 Rev. 00 Compliance Certification Services Inc. FCC ID: P27OC835 Report No.: T150508D07-RP Powerline Conducted Emissions Setup Photos Page 129 Rev. 00
1 | Tune Up | Parts List/Tune Up Info | 81.52 KiB | September 22 2015 |
Snap-on Diagnostics Tune up procedure The output power setting of EUT is set in the factory and followed the max level in below. There is no tune up procedure except factory default setting:
IEEE 802.11b mode: 16.5 dBm 2dB IEEE 802.11g mode: 16 dBm 2dB IEEE 802.11n HT 20 MHz mode : 16.5 dBm 2dB IEEE 802.11n HT 40 MHz mode: 16.5 dBm 2dB Kevin Kuo Sr. Manager / R&D Division Sercomm Corporation TEL: 886-2-2655-3988#2631 FAX: 886-2-2655-7379 E-Mail: kevin_kuo@sercomm.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-09-22 | 2422 ~ 2452 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2015-09-22
|
||||
1 | Applicant's complete, legal business name |
Sercomm Corporation
|
||||
1 | FCC Registration Number (FRN) |
0015548027
|
||||
1 | Physical Address |
8F, No. 3-1, YuanQu St, NanKang
|
||||
1 |
Taipei, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
V******@tuvam.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
P27
|
||||
1 | Equipment Product Code |
OC835
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
N**** W******
|
||||
1 | Title |
Engineer
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
N******@SERCOMM.COM
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Waterproof HD IP Camera | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output is conducted. This device has 20 and 40 MHz BW mode. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services Inc.
|
||||
1 | Name |
K****** C****
|
||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
k******@ccsrf.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC MO | 2412 | 2462 | 0.5845 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15C | CC MO | 2422 | 2452 | 0.5389 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC