FCC Radio Test Report FCC ID: P27SWSCM01N This report concerns (check one): Original Grant Class II Change Project No. Equipment Test Model Series Model Applicant Address
: 1805T073
: Z-Wave Smart Chime
: SW-SCM01N
: SW-SCM01Nxxxxxxxx (the 1st x should be "blank" or
"-"; the rest x could be 0 to 9, A to Z, a to z, "blank" or
"-", for marketing purpose)
: Sercomm Corporation
: 8F,No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Date of Receipt Date of Test Issued Date Tested by
: May 29, 2018
: May 29, 2018 ~ Jul. 09, 2018
: Jul. 31, 2018
: BTL Inc. Testing Engineer Technical Manager Authorized Signatory
:
:
:
(Kenji Lin)
(James Chiu)
(Andy Chiu) B T L I N C . No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City, Taiwan (R.O.C.) TEL:+886-2-2657-3299 FAX: +886-2-2657-3331 Report No.: BTL-FCCP-1-1805T073 Page 1 of 53 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufactures responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTLs laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer, so it is manufacturers responsibility to ensure that the apparatus meets the essential requirements in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCCP-1-1805T073 Page 2 of 53 Table of Contents Page 1 . CERTIFICATION 2 . SUMMARY OF TEST RESULTS 2.1 TEST FACILITY 2.2 MEASUREMENT UNCERTAINTY 3 . GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT 3.2 DESCRIPTION OF TEST MODES 3.3 BLOCKDIAGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED 3.4 DESCRIPTION OF SUPPORT UNITS 3.5 DUTY CYCLE 4 . EMC EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION Limits 4.1.2 TEST PROCEDURE 4.1.3 DEVIATION FROM TEST STANDARD 4.1.4 TEST SETUP 4.1.5 EUT OPERATING CONDITIONS 4.1.6 EUT TEST CONDITIONS 4.1.7 TEST RESULTS 4.2 RADIATED EMISSION MEASUREMENT 4.2.1 RADIATED EMISSION LIMITS 4.2.2 TESTPROCEDURE 4.2.3 DEVIATIONFROMTESTSTANDARD 4.2.4 TESTSETUP 4.2.5 EUT OPERATING CONDITIONS 4.2.6 EUT TEST CONDITIONS 4.2.7 TEST RESULTS (9KHz TO 30MHz) 4.2.8 TEST RESULTS (30 TO 1000 MHz) 4.2.9 TEST RESULTS(ABOVE1000 MHz) 5 . BANDWIDTH TEST 5.1 TEST PROCEDURE 5.2 DEVIATION FROM STANDARD 5.3 TEST SETUP 5.4 EUT OPERATION CONDITIONS 5.5 EUT TEST CONDITIONS 5.6 TEST RESULTS 6 . MEASUREMENT INSTRUMENTS LIST AND SETTING 6 7 7 8 9 9 9 10 10 11 12 12 12 12 12 13 13 13 13 14 14 15 15 16 17 17 17 17 17 18 18 18 18 18 18 18 19 Report No.: BTL-FCCP-1-1805T073 Page 3 of 53 Table of Contents Page 7 . EUT TEST PHOTO APPENDIX A - CONDUCTED EMISSION APPENDIX B -RADIATED EMISSION (9KHZ TO 30MHZ) APPENDIX C -RADIATED EMISSION (30MHZ TO 1000MHZ) APPENDIX D -RADIATED EMISSION (ABOVE 1000MHZ) APPENDIX E - BANDWIDTH 20 24 27 32 39 52 Report No.: BTL-FCCP-1-1805T073 Page 4 of 53 Issued No. REPORT ISSUED HISTORY Description BTL-FCCP-1-1805T073 Original Issue. Issued Date Jul. 16, 2018 MTP1807082 Revised antenna information and power rating. Jul. 31, 2018 Report No.: BTL-FCCP-1-1805T073 Page 5 of 53 1. CERTIFICATION Equipment Brand Name Test Model Series Model
: Z-Wave Smart Chime
: Sercomm, ADT
: SW-SCM01N
: SW-SCM01Nxxxxxxxx (the 1st x should be "blank" or "-"; the rest x could be 0 to 9, A to Z, a to z, "blank" or "-", for marketing purpose)
: Sercomm Corporation
: May 29, 2018 ~ Jul. 09, 2018
: Engineering Sample
: FCC Part15, Subpart C(15.249)/ ANSI C63.10-2013 Applicant Date of Test Test Sample Standard(s) The above equipment has been tested and found in compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1805T073) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: BTL-FCCP-1-1805T073 Page 6 of 53 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s):
FCC Part15, Subpart C (15.249) StandardSection Test Item Judgment Remark 15.207 15.209 15.249
-
Conducted Emission Radiated Spurious Emission Bandwidth PASS PASS PASS NOTE:
(1)N/A denotes test is not applicable in this test report. 2.1 TEST FACILITY The test facilities used to collect the test data in this report:
Conducted emission Test:
C05:
(FCC RN:674415; FCC DN:TW0659) No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) Radiated emission Test (Below 1GHz):
CB15: (FCC RN:674415; FCC DN:TW0659; ISED Assigned Code:20088-5) No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) Radiated emission Test (Above 1GHz):
CB15: (FCC RN:674415; FCC DN:TW0659; ISED Assigned Code:20088-5) No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) Report No.: BTL-FCCP-1-1805T073 Page 7 of 53 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. The BTL measurement uncertainty is less than the CISPR 16-4-2 Ucispr requirement. The reported uncertainty of measurement y U, where expanded uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement :
Test Site Method Measurement Frequency Range C05 CISPR 150 kHz ~ 30MHz U,(dB) 2.68 B. Radiated Measurement :
Test Site Method Measurement Frequency Range U,(dB) CB15
(3m) CISPR 9kHz ~ 150kHz 150kHz ~ 30MHz 2.82 2.58 Test Site Method Measurement Frequency Range CB15
(3m) CISPR 30MHz ~ 200MHz 30MHz ~ 200MHz 200MHz ~ 1,000MHz 200MHz ~ 1,000MHz Test Site Method Measurement Frequency Range CB15
(3m) CISPR 1GHz ~ 6GHz 1GHz ~ 6GHz 6GHz ~ 18GHz 6GHz ~ 18GHz Ant. H / V U,(dB) V H V H 4.20 3.64 4.56 3.90 Ant. H / V U,(dB) V H V H 4.46 4.40 3.88 4.00 Test Site Method Measurement Frequency Range U,(dB) CB15
(1m) CISPR 18 ~ 26.5 GHz 26.5 ~ 40 GHz 4.62 5.12 Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into account to declare the compliance or non-compliance to the specification. Our calculated Measurement Instrumentation Uncertainty is shown in the tables above. These are our Ulab values in CISPR 16-4-2 terminology. Since Table 1 of CISPR 16-4-2 has values of measurement instrumentation uncertainty, called UCISPR, as follows:
Conducted Disturbance (mains port) 150 kHz 30 MHz : 3.6 dB Radiated Disturbance (electric field strength on an open area test site or alternative test site) 30 MHz 1000 MHz : 5.2 dB It can be seen that our Ulab values are smaller than UCISPR. Report No.: BTL-FCCP-1-1805T073 Page 8 of 53 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Z-Wave Smart Chime Brand Name Sercomm, ADT Test Model SW-SCM01N Series Model SW-SCM01Nxxxxxxxx (the 1st x should be "blank" or "-"; the rest x could be 0 to 9, A to Z, a to z, "blank" or "-", for marketing purpose) Model Difference Different model distribute to different area. Power Source AC Mains. Power Rating I/P:AC 100-120V~50Hz Operation Frequency 908.4~916 MHz Modulation Technology FSK Data rate 17.2Kbps Field Strength 44.55dBuV/m Note:
1. For a more detailed features description, please refer to the manufacturers specifications or the user's manual. 2. Channel List:
Channe 01 02 03 Table for Filed Antenna:
Frequency
(MHz) 908.4 908.42 916 Ant. Manufacturer Model Name Antenna Type Connector Gain (dBi) 1 Sercomm SW-SCM01 coil antenna N/A
-3.49 3. 3.2 DESCRIPTION OF TEST MODES The test system was pre-tested based on the consideration of all possible combinations of EUT operation mode. Following mode(s) as (were) found to be the worst case(s) and selected for the final test. Test Items Conducted Emission Radiated Spurious Emission
(BELOW 1GHz) Radiated Spurious Emission
(ABOVE 1GHz) Bandwidth Test mode TX Mode TX Mode TX Mode TX Mode Channel Note 02 01/02/03 01/02/03 01/02/03
-
-
-
-
Report No.: BTL-FCCP-1-1805T073 Page 9 of 53 3.3 BLOCKDIAGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED 3.4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Mfr/Brand Model/Type No. FCC ID Series No.
-
-
-
-
-
-
Item Shielded Type Ferrite Core 1 YES YES Length 1.5m Note Power Cable Report No.: BTL-FCCP-1-1805T073 Page 10 of 53 3.5 DUTY CYCLE If duty cycle is 98 %, duty factor is not required. If duty cycle is < 98 %, duty factor shall be considered.
-
Duty cycle = 100 %
Duty Factor = 10 * log(1 / 1) = 0 Report No.: BTL-FCCP-1-1805T073 Page 11 of 53 4. EMC EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION Limits
(Frequency Range 150KHz-30MHz) Frequency of Emission (MHz) 0.15 -0.50 0.0 -5.0 5.0 -30.0 Note:
Conducted Limit (dBV) Quasi-peak 66 to 56*
56 60 Average 56 to 46*
46 50
(1) The limit of " * " decreases with the logarithm of the frequency
(2) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor(if use) Margin Level = Measurement Value - Limit Value The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 KHz 4.1.2 TEST PROCEDURE a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.1.3 DEVIATION FROM TEST STANDARD No deviation Report No.: BTL-FCCP-1-1805T073 Page 12 of 53 4.1.4 TEST SETUP 4.1.5 EUT OPERATING CONDITIONS The EUT was placed on the test table and programmed in normal function. 4.1.6 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 45% Test Voltage: AC 120V/60Hz 4.1.7 TEST RESULTS Please refer to the Appendix A. Report No.: BTL-FCCP-1-1805T073 Page 13 of 53 LISNEUTTest Receiver40 cm80 cmHorizontal Reference Ground Plane Vertical Reference Ground Plane 4.2 RADIATED EMISSION MEASUREMENT 4.2.1 RADIATED EMISSION LIMITS (FCC 15.209 ) Frequencies
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 960~1000 Field Strength
(micorvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance
(meters) 300 30 30 3 3 3 3 Harmonic emissions limits comply with below 54dBuV/m at 3m. Other emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or comply with the radiated emissions limits specified in section15.209(a) limit in the table below has to be followed. Note:
(1) The tighter limit applies at the band edges.
(2) Emission level (dBuV/m)=20log Emission level (uV/m). LIMITS OF RADIATED EMISSION MEASUREMENT (FCC 15.209 ) FREQUENCY (MHz) Above 1000
(dBuV/m) (at 3m) PEAK 74 AVERAGE 54 Notes:
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m). Spectrum Parameter Attenuation Start Frequency Stop Frequency Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 1000 MHz 10th carrier harmonic Setting Auto 9kHz~90kHz for PK/AVG detector 90kHz~110kHz for QP detector Start ~ Stop Frequency 110kHz~490kHz for PK/AVG detector Start ~ Stop Frequency Start ~ Stop Frequency 490kHz~30MHz for QP detector 30MHz~1000MHz for QP detector Report No.: BTL-FCCP-1-1805T073 Page 14 of 53 4.2.2 TESTPROCEDURE a. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 0.8 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(below 1GHz) b. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 1.5 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(above 1GHz) c. The height of the equipment or of the substitution antenna shall be 0.8 m or 1.5m,the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights find the maximum reading (used Bore sight function). e. The receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1GHz. f. The initial step in collecting radiated emission data is a receiver peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didnt perform.
(below 1GHz) h. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT shall be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured, but AVG Mode didnt perform. (above 1GHz) i. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.2.3 DEVIATIONFROMTESTSTANDARD No deviation Report No.: BTL-FCCP-1-1805T073 Page 15 of 53 4.2.4 TESTSETUP
(A) Radiated Emission Test Set-Up Frequency Below 1 GHz
(B) Radiated Emission Test Set-Up Frequency Above 1 GHz Report No.: BTL-FCCP-1-1805T073 Page 16 of 53 Amp.EUT1-4 m3 mReceiver0.8 mAbsorbersGround Plane1 mAmp.EUT1-4 m3 mReceiver0.8 mAbsorbersGround Plane1 mAbsorbers0.3 m0.7 m
(C) For radiated emissions below 30MHz 4.2.5 EUT OPERATING CONDITIONS The EUT was programmed to be in continuously transmitting mode. 4.2.6 EUT TEST CONDITIONS Temperature: 23C Relative Humidity: 70% Test Voltage: AC 120V/60Hz 4.2.7 TEST RESULTS (9KHz TO 30MHz) Please refer to the Appendix B. Remark:
the permissible value has no need to be reported.
(1) The amplitude of spurious emissions which are attenuated by more than 20 dB below
(2) Distance extrapolation factor = 40 log (specific distance / test distance) (dB);.
(3) Limit line = specific limits (dBuV) + distance extrapolation factor.. 4.2.8 TEST RESULTS (30 TO 1000 MHz) Please refer to the Appendix C 4.2.9 TEST RESULTS(ABOVE1000 MHz) Please refer to the Appendix D Remark:
(1) EUT Orthogonal Axis:
X - denotes Laid on TableY - denotes Vertical StandZ - denotes Side Stand
(2) During the measurements above 1 GHz it is taken care of that the EUT is always within the 3 dB cone of radiation BW of the used antenna Report No.: BTL-FCCP-1-1805T073 Page 17 of 53 5. BANDWIDTH TEST 5.1 TEST PROCEDURE a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram below, b. Spectrum Setting: RBW= 3kHz, VBW=3kHz, Sweep time = Auto. 5.2 DEVIATION FROM STANDARD No deviation. 5.3 TEST SETUP 5.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 unless otherwise a special operating condition is specified in the follows during the testing. 5.5 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55% Test Voltage: AC 120V/60Hz 5.6 TEST RESULTS Please refer to the Appendix E Report No.: BTL-FCCP-1-1805T073 Page 18 of 53 6. MEASUREMENT INSTRUMENTS LIST AND SETTING Conducted Emission Measurement Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 2 TWO-LINE V-NETWORK Test Cable R&S EMCI 3 EMI Test Receiver R&S 4 Measurement Software EZ ENV216 101050 Mar. 08, 2019 EMCCFD300-BM
-BMR-6000 ESR7 EZ_EMC
(Version NB-03A) 170715 Aug. 08, 2018 101433 Dec. 10, 2018 N/A N/A Radiated Emission Measurement Item Kind of Equipment Manufacturer Preamplifier Preamplifier EMCI EMCI Type No. 012645B Serial No. Calibrated until 980267 Feb. 27, 2019 EMC02325 980217 Dec. 28, 2018 Test Cable EMCI EMC104-SM-SM-8000 8m Jan. 03, 2019 Test Cable EMCI EMC104-SM-SM-800 150207 Jan. 03, 2019 Test Cable EMCI 6 MXE EMI Receiver Agilent Signal Analyzer Agilent Loop Ant EMCI EEMC104-SM-SM-300 0 N9038A N9010A LPA600 151205 Jan. 03, 2019 MY55420127 Jan. 08, 2019 MY52220990 Feb. 21, 2019 274 May 03, 2019 Horm Ant Trilog-Broadband Antenna SCHWARZB ECK BBHA 9120D 9120D-1342 Feb. 27, 2019 Schwarzbeck VULB 9168 9168-548 Jan. 15, 2019 5dB Attenuator EMCI EMCI-N-6-05 AT-N0623 Jan. 15, 2019 1 2 3 4 5 7 8 9 10 11 Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Spectrum Analyzer R&S R&S/FSP30 100854 May 24, 2019 Bandwidth Remark: N/A denotes no model name, serial no. or calibration specified. All calibration period of equipment list is one year. Report No.: BTL-FCCP-1-1805T073 Page 19 of 53 APPENDIX A - CONDUCTED EMISSION Report No.: BTL-FCCP-1-1805T073 Page 24 of 53 Test Mode:
TX 908.42MHz Line Report No.: BTL-FCCP-1-1805T073 Page 25 of 53 Test Mode:
TX 908.42MHz Neutral Report No.: BTL-FCCP-1-1805T073 Page 26 of 53 APPENDIX B -RADIATED EMISSION (9KHZ TO 30MHZ) Report No.: BTL-FCCP-1-1805T073 Page 27 of 53 Test Mode:
TX Mode_908.42MHz Ant 90 Report No.: BTL-FCCP-1-1805T073 Page 28 of 53 Test Mode:
TX Mode_908.42MHz Ant 90 Report No.: BTL-FCCP-1-1805T073 Page 29 of 53 Test Mode:
TX Mode_908.42MHz Ant 0 Report No.: BTL-FCCP-1-1805T073 Page 30 of 53 Test Mode:
TX Mode_908.42MHz Ant 0 Report No.: BTL-FCCP-1-1805T073 Page 31 of 53 APPENDIX C -RADIATED EMISSION (30MHZ TO 1000MHZ) Report No.: BTL-FCCP-1-1805T073 Page 32 of 53 Test Mode TX Mode_908.4MHz Polarization Vertical Report No.: BTL-FCCP-1-1805T073 Page 33 of 53 Test Mode TX Mode_908.4MHz Polarization Horizontal Report No.: BTL-FCCP-1-1805T073 Page 34 of 53 Test Mode TX Mode_908.42MHz Polarization Vertical Report No.: BTL-FCCP-1-1805T073 Page 35 of 53 Test Mode TX Mode_908.42MHz Polarization Horizontal Report No.: BTL-FCCP-1-1805T073 Page 36 of 53 Test Mode TX Mode_916MHz Polarization Vertical Report No.: BTL-FCCP-1-1805T073 Page 37 of 53 Test Mode TX Mode_916MHz Polarization Horizontal Report No.: BTL-FCCP-1-1805T073 Page 38 of 53 APPENDIX D -RADIATED EMISSION (ABOVE 1000MHZ) Report No.: BTL-FCCP-1-1805T073 Page 39 of 53 Test Mode TX Mode_908.4MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 40 of 53 Test Mode TX Mode_908.4MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 41 of 53 Test Mode TX Mode_908.4MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 42 of 53 Test Mode TX Mode_908.4MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 43 of 53 Test Mode TX Mode_908.42MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 44 of 53 Test Mode TX Mode_908.42MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 45 of 53 Test Mode TX Mode_908.42MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 46 of 53 Test Mode TX Mode_908.42MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 47 of 53 Test Mode TX Mode_916MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 48 of 53 Test Mode TX Mode_916MHz Polarization Vertical Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 49 of 53 Test Mode TX Mode_916MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 50 of 53 Test Mode TX Mode_916MHz Polarization Horizontal Orthogonal Axis: X Report No.: BTL-FCCP-1-1805T073 Page 51 of 53 APPENDIX E - BANDWIDTH Report No.: BTL-FCCP-1-1805T073 Page 52 of 53 Test Mode :
TX Mode_ CH01/02/03 Frequency 20dB Bandwidth 99% Occupied BW
(MHz) 908.4 908.42 916
(MHz) 0.31 0.32 0.33