all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual | Users Manual | 997.25 KiB | August 31 2012 | |||
1 |
|
Internal photos | Internal Photos | 537.61 KiB | August 31 2012 | |||
1 |
|
External photos | External Photos | 198.90 KiB | August 31 2012 | |||
1 |
|
Label | ID Label/Location Info | 1.80 MiB | August 31 2012 | |||
1 |
|
Agents letter | Cover Letter(s) | 357.16 KiB | August 31 2012 | |||
1 | Antenna spec. | Operational Description | August 31 2012 | confidential | ||||
1 | Block diagram | Block Diagram | August 31 2012 | confidential | ||||
1 |
|
Confidentiality letter | Cover Letter(s) | 376.26 KiB | August 31 2012 | |||
1 | Operational description | Operational Description | August 31 2012 | confidential | ||||
1 | Schematics | Schematics | August 31 2012 | confidential | ||||
1 |
|
Test report | Test Report | 689.66 KiB | August 31 2012 | |||
1 |
|
Test setup photos | Test Setup Photos | 343.76 KiB | August 31 2012 |
1 | User manual | Users Manual | 997.25 KiB | August 31 2012 |
SZ-DWS01 ZigBee Door Window Sensor User Guide Table of Contents CHAPTER 1 INTRODUCTION...................................................................................... 1 Package Contents ................................................................................................ 1 Specfication .......................................................................................................... 1 CHAPTER 2 DEVICE DESCRIPTION .......................................................................... 2 Installation............................................................................................................. 2 Operation .............................................................................................................. 4 External contact wiring (Optional)...................................................................... 5 CHAPTER 3 REGULATORY APPROVAL ................................................................... 7 Copyright 201 2. All Rights Reserved. Document Version: 1.0 All trademarks and trade names are the properties of their respective owners. ii Chapter 1 Introduction 1 This Chapter provides an overview of the ZigBee Door/Window Sensor features and capabilities. Congratulations on the purchase of your new ZigBee Door/Window Sensor. The ZigBee Door/Window Sensor is a consumer electronic device, which is used for home monitoring and security. Package Contents Specification Frequency 2.4GHz Batter Type Magnet Type Operating Temperature Storage Temperature Battery Life RF Range Dimention DC 3V, CR2032 x 2
< 1.27 cm ( 0.5 inch ) 0 C to 50 C (32 - 122F)
-20 C to 70 C (-4 - 158F) 1 ~ 2 years 100M Main Unit: 13 mm x 20 mm x 115 mm (0.51" x 0.78" x 4.52") Magnet Unit: 10 mm x 12mm x 47 mm (0.39" x 0.47" x 1.85") 1 Chapter 2 Device Description This Chapter provides device description for the ZigBee Door/Window Sensor. 2 Installation NOTE: Please make sure that the sensor and magnet is located less then 1.27cm (0.5 inch) from each other. Intallation 1. Hold the sensor near the top of the door, close to the opening edge of the door. This is the mounting location for the sensor. 2. Using a flat head screw driver insert into the notch located on the case and gently twist to open. 2 3. Insert CR2032 Battery Use care when installing the battery and observe the correct polarity when the battery is inserted. Use only CR2032 batteries for replacement. WARNING!: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. 4. Use either one of the following methods to install the sensor:
Remove the back plate of the sensor; use this as the mounting bracket. Use the screwdriver to secure the back plate to the wall with the screws provided. Use provided adhesive on the sensor. Attach the sensor to the door. Press firmly and hold in place for a few seconds. 3 Magnet Setup 1. Attach the magnet on the location next to the sensor by using either one of the following methods:
Remove the back plate of the magnet; use this as the mounting bracket. Use the screwdriver to secure the back plate to the wall with the screws provided. Use provided adhesive on the magnet. Attach the sensor to the door. Press firmly and hold in place for a few seconds. 2. Make sure the alignment marks of both devices are facing each other. Operation 4 Join Function For "Join" a network, please do the following instruction:
Press the Join/Leave button for less than 1 second. The LED is blinking while processing. If the sensor has been joined with the controller successfully, the Green LED will be on for 2 seconds and then off. The Green LED will be off instantly if failed. Leave Function For "Leave" a network, please do the following instruction:
Press Join/Leave button for 3 seconds to let the sensor disassociate from the controller. The LED will stay off during the normal operation. The sensor is equipped with a tamper switch. If the cover of sensor is removed, the sensor will send an alarm to the ZigBee controller. The sensor will be in "Awake" mode before replacing External contact wiring (Optional) 1.remove screw 2.Plug two-pin connector. 3.close screw 4. Connect wire to N/C dry reed switch device. (Option) 5 Use the following specifications for the external reed switch device. Maximum wire length:1 m 6 Chapter 3 REGULATORY APPROVAL The FCC Statement FCC Radiation Exposure Statement 7 CE Approval CE Standards This product complies with the 99/5/EEC directives, including the following safety and EMC standards:
EN30 0328-2 EN30 1489-1/-17 CE Marking Warning This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. UL Notices: This device complies with UL Standard UL634. 8
1 | Internal photos | Internal Photos | 537.61 KiB | August 31 2012 |
INTERNAL PHOTOGRAPHS OF EUT Report No: T120308D05 Page 3 Rev.00 Report No: T120308D05 Antenna Page 4 Rev.00 Report No: T120308D05 Page 5 Rev.00
1 | External photos | External Photos | 198.90 KiB | August 31 2012 |
EXTERNAL PHOTOGRAPHS OF EUT Report No: T120803D05 Page 1 / 5 Rev.00 Report No: T120308D05 Page 2 Rev.00
1 | Label | ID Label/Location Info | 1.80 MiB | August 31 2012 |
44 x1
. 8 1 4 Label:40x20mm ZigBee Door Window Sensor /Model No.: SZ-DWS01 SerComm SN:XXXXXXXXXX ZID:XXXXXXXXXXXXX FCC ID: P27SZDWS01 Made in Taiwan Factory ID 10x3mm Input : DC 3V 3C
,
:30x8mm
:
Black Notes:
1.: 50#Mylar,PET 2./ , 3./:
4.:+/- 0.2mm 5.RoHS SZ-DWS01
/
932AHV0001 2012.07.30
1 | Agents letter | Cover Letter(s) | 357.16 KiB | August 31 2012 |
SerComm Corporation Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Chu Nan Office: 3F, No. 81, YuYi Rd., Chu-Nan, Miao-Li 350, Taiwan, R.O.C. TEL: 886-37-585-899 FAX: 886-37-585-000 DateAugust 13, 2012 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, SerComm Corporation hereby authorize Compliance Certification Services Inc / Stan Lin . to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 2013/02/13 Your Sincerely, Ronnie Cheng Associate Manager / R&D Division SerComm Corporation TEL: 886-2-2655-3988#2547 FAX: 886-2-2655-7379 E-Mail: Ronnie_cheng@sercomm.com
1 | Confidentiality letter | Cover Letter(s) | 376.26 KiB | August 31 2012 |
SerComm Corporation Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Chu Nan Office: 3F, No. 81, YuYi Rd., Chu-Nan, Miao-Li 350, Taiwan, R.O.C. TEL: 886-37-585-899 FAX: 886-37-585-000 DateAugust 13, 2012 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Confidentiality Request FCC ID: P27SZDWS01 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commissions Rules, SerComm Corporation hereby requests permanent confidential treatment of information accompanying this application as outlined below:
Common exhibits for which confidentiality is requested are:
Schematics Block Diagrams Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Your Sincerely, Ronnie Cheng Associate Manager / R&D Division SerComm Corporation TEL: 886-2-2655-3988#2547 FAX: 886-2-2655-7379 E-Mail: Ronnie_cheng@sercomm.com
1 | Test report | Test Report | 689.66 KiB | August 31 2012 |
Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 FCC 47 CFR PART 15 SUBPART C TEST REPORT For ZigBee Door Window Sensor Model: SZ-DWS01xxxxxxxx (x= 0~9, A~Z, Blank or any Character) Trade Name: SerComm Issued to 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. SerComm Corporation Issued by Compliance Certification Services Inc. No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841, Taiwan, R.O.C. TEL: 886-3-324-0332 FAX: 886-3-324-5235 http://www.ccsrf.com service@ccsrf.com Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by TAF, A2LA, NIST or any government agencies. The test results in the report only apply to the tested sample. Page 1 / 45 Rev.00 Rev. 00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Issue Date Aug. 17, 2012 Revision History Revisions Effect Page Revised By Initial Issue ALL Jill Shiau This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 2 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ...........................................................................................4 2. EUT DESCRIPTION................................................................................................................5 3. TEST METHODOLOGY..........................................................................................................6 3.1 EUT CONFIGURATION.....................................................................................................6 3.2 EUT EXERCISE.................................................................................................................6 3.3 GENERAL TEST PROCEDURES......................................................................................6 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ..........................................7 3.5 DESCRIPTION OF TEST MODES.....................................................................................7 4. INSTRUMENT CALIBRATION ...............................................................................................8 4.1 MEASURING INSTRUMENT CALIBRATION ....................................................................8 4.2 MEASUREMENT EQUIPMENT USED ..............................................................................8 4.3 MEASUREMENT UNCERTAINTY.....................................................................................8 5. FACILITIES AND ACCREDITATIONS...................................................................................9 5.1 FACILTIES.........................................................................................................................9 5.2 EQUIPMENT......................................................................................................................9 5.3 TABLE OF ACCREDITATIONS AND LISTINGS..............................................................10 6. SETUP OF EQUIPMENT UNDER TEST ..............................................................................11 6.1 SETUP CONFIGURATION OF EUT ................................................................................11 6.2 SUPPORT EQUIPMENT..................................................................................................11 7. FCC PART 15.247 REQUIREMENTS ..................................................................................12 7.1 6DB BANDWIDTH ............................................................................................................12 7.2 PEAK POWER .................................................................................................................15 7.3 AVERAGE POWER .........................................................................................................18 7.4 BAND EDGES MEASUREMENT.....................................................................................21 7.5 PEAK POWER SPECTRAL DENSITY.............................................................................26 7.6 SPURIOUS EMISSIONS..................................................................................................29 7.7 POWERLINE CONDUCTED EMISSIONS.......................................................................40 8. APPENDIX I RADIO FREQUENCY EXPOSURE.................................................................41 9. APPENDIX II PHOTOGRAPHS OF TEST SETUP...............................................................43 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 3 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 1. TEST RESULT CERTIFICATION Applicant:
Manufacturer:
SerComm Corporation 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. SerComm Corporation 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. Equipment Under Test: Wireless Network Camera Trade Name:
Model:
SerComm SZ-DWS01xxxxxxxx
(x= 0~9, A~Z, Blank or any Character) August 13 ~ 14, 2012 Date of Test:
APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15 Subpart C No non-compliance noted We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 15.207, 15.209, 15.247. The test results of this report relate only to the tested sample EUT identified in this report. Approved by:
Stan Lin Section Manager Reviewed by:
Jill Shiau Section Manager This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 4 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 2. EUT DESCRIPTION Product Wireless Network Camera Trade Name Model Number Model Discrepancy SerComm SZ-DWS01xxxxxxxx (x= 0~9, A~Z, Blank or any Character);
1. The mean of X (x= 0~9, A~Z, Blank or any Character) on model number just for marketing purpose only. 2. Client consigns only one model sample to test (model number: SZ-DWS01). Therefore, the testing Lab. just guarantees the unit, which has been tested. EUT Power Rating 3VDC From Battery RF Module Manufacturer ARM Model EM357 Operating Frequency Range 2405 ~ 2480MHz Transmit Power 22.32dBm (0.1706W) Modulation Technique OPQSK (Offset Quadrature Phase Shift Keyed) Number of Channels 16 Channels Antenna Specification Remark:
PCB Antenna / Gain: 2.7dBi 1. The sample selected for test was production product and was provided by manufacturer. 2. This submittal(s) (test report) is intended for FCC ID: P27SZDWS01 filing to comply with Section 15.207, 15.209 and 15.247 of the FCC Part 15, Subpart C Rules. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 5 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 3. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.4 and FCC CFR 47 Part 2, Part 15.207, 15.209 and 15.247. 3.1 EUT CONFIGURATION The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 3.2 EUT EXERCISE The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C. 3.3 GENERAL TEST PROCEDURES Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 13.1.4.1 of ANSI C63.4 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 13.1.4.1 of ANSI C63.4. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 6 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency bands listed below:
MHz MHz 0.090 - 0.110 10.495 - 0.505 2.1735 - 2.1905 4.125 - 4.128 4.17725 - 4.17775 4.20725 - 4.20775 6.215 - 6.218 6.26775 - 6.26825 6.31175 - 6.31225 8.291 - 8.294 8.362 - 8.366 8.37625 - 8.38675 8.41425 - 8.41475 12.29 - 12.293 12.51975 - 12.52025 12.57675 - 12.57725 13.36 - 13.41 16.42 - 16.423 16.69475 - 16.69525 16.80425 - 16.80475 25.5 - 25.67 37.5 - 38.25 73 - 74.6 74.8 - 75.2 108 - 121.94 123 - 138 149.9 - 150.05 156.52475 -
156.52525 156.7 - 156.9 162.0125 - 167.17 167.72 - 173.2 240 - 285 322 - 335.4 MHz 399.9 - 410 608 - 614 960 - 1240 1300 - 1427 1435 - 1626.5 1645.5 - 1646.5 1660 - 1710 1718.8 - 1722.2 2200 - 2300 2310 - 2390 2483.5 - 2500 2655 - 2900 3260 - 3267 3332 - 3339 3345.8 - 3358 3600 - 4400 GHz 4.5 - 5.15 5.35 - 5.46 7.25 - 7.75 8.025 - 8.5 9.0 - 9.2 9.3 - 9.5 10.6 - 12.7 13.25 - 13.4 14.47 - 14.5 15.35 - 16.2 17.7 - 21.4 22.01 - 23.12 23.6 - 24.0 31.2 - 31.8 36.43 - 36.5
(2) 1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. 2 Above 38.6
(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within these frequency bands shall not exceed the limits shown in Section 15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall be demonstrated using measurement instrumentation employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be demonstrated based on the average value of the measured emissions. The provisions in Section 15.35 apply to these measurements. 3.5 DESCRIPTION OF TEST MODES The EUT (model: SZ-DWS02) had been tested under operating condition. Test program used to control the EUT for staying in continuous transmitting mode was programmed. After verification, all tests were carried out with the worst case test modes as shown below except radiated spurious emission below 1GHz, which worst case was in transmitting mode only. The field strength of spurious emission was measured in the following position: EUT stand-up position (Z axis), lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the worst case was recorded. Channel Low (2405MHz), Channel Mid (2445MHz) and Channel High (2480MHz) were chosen for the final testing. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 7 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 4. INSTRUMENT CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is traceable to recognized national standards. 4.2 MEASUREMENT EQUIPMENT USED Equipment Used for Emissions Measurement Remark: Each piece of equipment is scheduled for calibration once a year. Conducted Emissions Test Site Name of Equipment Manufacturer Spectrum Analyzer Spectrum Analyzer Agilent R&S Anritsu Anritsu Power meter Power Sensor Model E4446A FSEB ML2495A MA2411B Serial Number Calibration Due MY48250064 825829/011 1033009 0917221 12/25/2012 12/18/2012 08/18/2012 08/18/2012 3M Semi Anechoic Chamber Name of Equipment Manufacturer Spectrum Analyzer Agilent Pre-Amplifier Pre-Amplifier Pre-Amplifier HP HP MITEQ EMI Test Receiver SCHAFFNER Model E4446A 8447D 8449B AMF-6F-26040 0-40-8P SCR 3501 Loop Antenna Bilog Antenna Horn Antenna Horn Antenna Antenna Tower Turn Table Test S/W EMCO 6502 SCHWAZBECK VULB9160 EMCO EMCO CCS CCS 3115 3116 CC-A-1F CC-T-1F Serial Number Calibration Due MY48250064 2944A06530 3008A01738 12/25/2012 01/03/2013 04/17/2013 05/20/2013 01/11/2013 06/11/2013 10/03/2012 06/14/2013 10/04/2012 N.C.R N.C.R 985646 430 2356 3084 9602-4659 00026370 N/A N/A LabVIEW 6.1 (Wugu Chamber EMI Teat V1_4.5.3) 4.3 MEASUREMENT UNCERTAINTY Parameter Powerline Conducted Emission 3M Semi Anechoic Chamber / 30MHz ~ 1GHz 3M Semi Anechoic Chamber / Above 1GHz Uncertainty N/A 3.7046 3.0958 Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 8 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 5. FACILITIES AND ACCREDITATIONS 5.1 FACILTIES All measurement facilities used to collect the measurement data are located at No. 163-1, Jhongsheng Rd., Sindien District, Taipei City 23151, Taiwan Tel:
886-2-2217-0894 / Fax: 886-2-2217-1029 No 11, Wugong 6th Rd, Wugu District, New Taipei City 24891, Taiwan (R.O.C) Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045 No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841,Taiwan, R.O.C. Tel: 886-3-324-0332 / Fax: 886-3-324-5235 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. 5.2 EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test Receivers. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, Radio Interference Measuring Apparatus and Measurement Methods. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 9 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 5.3 TABLE OF ACCREDITATIONS AND LISTINGS Country Agency Scope of Accreditation Logo USA A2LA CFR 47, FCC Part15/18, CISPR 22, EN 55022, ICES-003, AS/NZS CISPR 22, VCCI V-3, EN 55011, CISPR 11, IEC/EN 61000-4-2/3/4/5/6/8/11, EN 61000-6-1/2/3/4, EN 55024, CISPR 24, AS/NZS CISPR 24, AS/NZS 61000.6.2, EN 55014-1/-2, ETSI EN 300 386 v1.3.2/v1.3.3, IEC/EN 61000-3-2, AS/NZS 61000.3.2, IEC/EN 61000-3-3, AS/NZS 61000.3.3 USA FCC MRA 3/10 meter Open Area Test Sites to perform FCC Part 15/18 measurements TW1026 Japan VCCI 3/10 meter Open Area Test Sites and conducted test sites to perform radiated/conducted measurements R-2882/2541/2798/725/1868 C-402/747/912 T-1930/1646 Taiwan TAF EN 55014-1, CISPR 14, CNS 13781-1, EN 55013, CISPR 13, CNS 13439, EN 55011, CISPR 11, CNS 13803, PLMN09, IS2045-0, LP0002 FCC Part 27/90, Part 15B/C/D/E, RSS-192/193/210/310 ETSI EN 300 328/ 300 220-1/ 300 220-2/ 301 893/ 301 489-01/ 301 489-03/ 301 489-07 /
301 489-17/ 300 440-1/ 300 440-2 AS/NZS 4268, AS/NZS 4771 CISPR 22, EN 55022, CNS 13438, AS/NZS CISPR 22, VCCI, IEC/EN 61000-4-2/3/4/5/6/8/11, CNS 14676-2/3/4/5/6/8, CNS 14934-2/3, CNS 13783-1, CNS 13439, CNS 13803 Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13439, CNS 14115 Canada Industry Canada RSS-Gen Issue 3 SL2-IS-E-0014 / IN-E-0014
/A1-E-0014 /R1-E-0014
/R2-E-0014 /L1-E-0014 IC 2324C-5 Note: No part of this report may be used to claim or imply product endorsement by A2LA, TAF or other government agency. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 10 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 6.2 SUPPORT EQUIPMENT For Conducted Emission & Radiated Emission (Above 1GHz)measurement:
No. Device Type Brand Data Cable Series No. Power Cord FCC ID Model 1. Notebook PC DELL D400 0932RY 2 3 Test Jig Power Adapter N/A LEI N/A MT-12-Y120100-A1 N/A N/A E2K24GBRL LAN Cable:
Unshielded, 10m N/A Unshielded, 0.5m AC I/P:
Unshielded, 1.8m DC O/P:
Unshielded, 1.8m with a core N/A FCC DoC Unshielded, 1.8m N/A For Radiated Emission measurement:
No. Device Type N/A Brand Model Series No. FCC ID Data Cable Power Cord
**No any support equipment during the test. Remark: Grounding was established in accordance with the manufacturers requirements and conditions for the intended use. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 11 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7. FCC PART 15.247 REQUIREMENTS 7.1 6dB BANDWIDTH LIMIT According to 15.247(a)(2), systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz. TEST CONFIGURATION EUT Spectrum Analyzer TEST PROCEDURE 1. Place the EUT on the table and set it in the transmitting mode. 2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 3. Set the spectrum analyzer as RBW = 100kHz, VBW = 300kHz, Span = 30MHz or 50MHz, Sweep = auto. 4. Mark the peak frequency and 6dB (upper and lower) frequency. 5. Repeat until all the rest channels are investigated. TEST RESULTS No non-compliance noted TEST DATA Channel Low Mid High Frequency
(MHz) Bandwidth (MHz) 2405 2441 2480 1.629 1.491 1.590 Limit
(kHz)
>500 Result PASS PASS PASS This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 12 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Test Plot 6dB Bandwidth (CH Low) 6dB Bandwidth (CH Mid) This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 13 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 6dB Bandwidth (CH High) This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 14 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.2 PEAK POWER LIMIT The maximum peak output power of the intentional radiator shall not exceed the following:
1. According to 15.247(b)(3), for systems using digital modulation in the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz: 1 Watt. 2. According to 15.247(b)(4), the conducted output power limit specified in paragraph (b) of this section is based on the use of antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values in paragraphs
(b)(1), (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi. TEST CONFIGURATION EUT Spectrum Analyzer TEST PROCEDURE Per KDB 558074 5.2.1.2/ or 5.2.2.1. The transmitter output is connected to the spectrum analyzer. Set the RBW = 1MHz, VBW = 3MHz, Detector = Peak, Trace mode = max hold, Sweep = auto couple. Record the max reading. Repeat the above procedure until the measurements for all frequencies are completed. TEST RESULTS No non-compliance noted TEST DATA Channel Frequency
(MHz) Output Power
(dBm) Output Power
(W) Limit
(W) Low Mid High 2405 2441 2480 22.32 21.04 3.68 0.1706 0.1271 0.0023 1 Result PASS PASS PASS This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 15 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 TEST PLOT CH Low CH Mid This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 16 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 CH High This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 17 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.3 AVERAGE POWER LIMIT None; for reporting purposes only. TEST CONFIGURATION EUT Spectrum Analyzer TEST PROCEDURE Per KDB 558074 5.2.1.2/ or 5.2.2.1. The transmitter output is connected to the spectrum analyzer. Set the RBW = 1MHz, VBW = 3MHz, Detector = Average, Sweep = auto couple. Record the reading. Repeat the above procedure until the measurements for all frequencies are completed. TEST RESULTS No non-compliance noted TEST DATA Channel Frequency
(MHz) Output Power
(dBm) Output Power
(W) Low Mid High 2405 2441 2480 19.58 18.64 1.12 0.0908 0.0731 0.0013 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 18 Rev.00 Test Plot CH Low CH Mid Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 19 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 CH High This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 20 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.4 BAND EDGES MEASUREMENT LIMIT According to 15.247(d), in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see Section 15.205(c)). TEST CONFIGURATION Antenna tower EUT 3m 4m Horn antenna Spectrum analyzer Turntable 0.8m 1m 30cm Pre-amp TEST PROCEDURE 1. The EUT is placed on a turntable, which is 0.8m above the ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. out the highest emission. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find 4. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the emission:
(a) PEAK: RBW=VBW=1MHz / Sweep=100ms
(b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO 5. Repeat the procedures until all the PEAK and AVERAGE versus POLARIZATION are measured. TEST RESULTS Refer to attach spectrum analyzer data chart. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 21 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Test Plot Band Edges (CH Low) Detector mode: Peak Polarity: Vertical Detector mode: Average Polarity: Vertical This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 22 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Detector mode: Peak Polarity: Horizontal Detector mode: Average Polarity: Horizontal This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 23 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Band Edges (CH High) Detector mode: Peak Polarity: Vertical Detector mode: Average Polarity: Vertical This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 24 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Detector mode: Peak Polarity: Horizontal Detector mode: Average Polarity: Horizontal This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 25 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.5 PEAK POWER SPECTRAL DENSITY LIMIT 1. According to 15.247(e), for digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. 2. According to 15.247(f), the digital modulation operation of the hybrid system, with the frequency hopping turned off, shall comply with the power density requirements of paragraph (d) of this section. TEST CONFIGURATION EUT Spectrum Analyzer TEST PROCEDURE Per KDB 558074 5.2.1.2/ or 5.2.2.1. The transmitter output is connected to a spectrum analyzer. Set the RBW = 100 kHz, VBW 300 kHz, span 5-30% greater than EBW, Detector = peak, Trace mode = max hold, Sweep = auto couple. Scale the observed power level to an equivalent value in 3 kHz by adjusting (reducing) themeasured power by a bandwidth correction factor (BWCF) where BWCF = 10log (3 kHz/100 kHz = -15.2 dB). Record the maximum reading. Repeat the above procedure until the measurements for all frequencies are completed. TEST RESULTS No non-compliance noted TEST DATA Channel Frequency
(MHz) Low Mid High 2405 2441 2480 100kHz PPSD
(dBm) 15.70 14.67
-2.50 3kHz PPSD
(dBm) 0.50
-0.53
-17.70 Limit
(dBm) Result 8.00 PASS This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 26 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Test Plot PPSD (CH Low) PPSD (CH Mid) This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 27 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 PPSD (CH High) This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 28 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.6 SPURIOUS EMISSIONS 7.6.1 CONDUCTED MEASUREMENT LIMIT According to 15.247(d), in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see Section 15.205(c)). TEST CONFIGURATION EUT Spectrum Analyzer TEST PROCEDURE Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna port conducted emissions meet the specified limit and to identify any spurious signals that require further investigation or measurements on the radiated emissions site. The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100 kHz. The video bandwidth is set to 100 kHz. Measurements are made over the 30MHz to 26GHz range with the transmitter set to the lowest, middle, and highest channels. TEST RESULTS No non-compliance noted. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 29 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Test Plot Spurious Emissions CH Low CH Mid This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 30 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 CH High This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 31 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Conducted band-edge CH Low CH High This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 32 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.6.2 RADIATED EMISSIONS LIMIT 1. According to 15.209(a), except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table:
Frequency
(MHz) 30-88 88-216 216-960 Above 960 Field Strength
(V/m) 100*
150*
200*
500 Measurement Distance
(m) 3 3 3 3 Remark: Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241. 2. In the emission table above, the tighter limit applies at the band edges. Frequency
(MHz) 30-88 88-216 216-960 Above 960 Field Strength
(V/m at 3-meter) 100 150 200 500 Field Strength
(dBV/m at 3-meter) 40 43.5 46 54 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 33 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 TEST CONFIGURATION Below 1 GHz EUT 3m 4m Turntable 0.8m 1m Reference ground plane Above 1 GHz EUT 3m 4m Antenna tower Bi-log antenna Spectrum analyzer Antenna tower Horn antenna Spectrum analyzer Turntable 0.8m 1m 30cm Pre-amp This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 34 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 TEST PROCEDURE 1. The EUT is placed on a turntable, which is 0.8m above ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest emissions. 4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 5. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. 6. Set the spectrum analyzer in the following setting as:
Below 30MHz RBW=9kHz / VBW=300kHz / Sweep=AUTO 30 ~ 1000MHz:
RBW=120kHz / VBW=3MHz / Sweep=AUTO Above 1GHz:
(a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO 7. Repeat above procedures until the measurements for all frequencies are complete. TEST RESULTS No non-compliance noted. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 35 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 TEST DATA Below 1GHz Operation Mode:
Temperature:
Humidity:
Transmitting 26C 56% RH Test Date:
Tested by:
Polarity:
Aug. 13, 2012 Clark Su Ver. / Hor. Frequency
(MHz) 62.9799 185.1999 253.0999 353.9800 465.5299 558.6499 53.2800 216.2400 328.7600 363.6800 393.7500 475.2300 Remark:
Reading
(dBuV) 47.63 47.10 48.83 47.36 42.39 43.93 45.67 43.30 41.17 40.80 38.93 36.47 Correction Factor
(dB/m)
-15.23
-13.62
-12.27
-10.37
-7.14
-5.73
-14.30
-14.21
-9.75
-10.23
-9.80
-7.06 Result
(dBuV/m) 32.40 33.48 36.56 36.99 35.25 38.20 31.37 29.09 31.42 30.57 29.13 29.41 Limit
(dBuV/m) 40.00 43.50 46.00 46.00 46.00 46.00 40.00 46.00 46.00 46.00 46.00 46.00 Margin
(dB)
-7.60
-10.02
-9.44
-9.01
-10.75
-7.80
-8.63
-16.91
-14.58
-15.43
-16.87
-16.59 Ant. Pol.
(H/V) Remark V V V V V V H H H H H H QP QP QP QP QP QP QP QP QP QP QP QP 1. No emission found between lowest internal used / generated frequency to 30 MHz. (9kHz ~ 30MHz) 2. Measuring frequencies from 9 kHz to the 1GHz. 3. Radiated emissions measured in the measured frequency range were made with an instrument using peak detector or quasi-peak detector mode. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. The IF bandwidth of SPA between 30MHz to 1GHz was 100kHz. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 36 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Above 1 GHz Operation Mode: TX / CH Low Temperature:
Humidity:
26C 56 % RH Freq.
(MHz) 1978.000 2878.000 4810.000 4810.000 7215.000 7215.000 N/A 1358.000 2668.000 4809.055 4810.000 7215.000 7215.000 N/A Remark:
Reading
(dBuV) 49.68 48.40 58.03 48.28 47.35 35.84 51.95 49.22 44.95 54.69 44.49 36.00 Correct Factor
(dB/m)
-1.65
-0.98 2.35 2.35 10.12 10.12
-7.98
-3.37 5.60 5.62 10.69 10.69 Aug. 13, 2012 Test Date:
Tested by: Clark Su Polarity:
Ver. / Hor. Result
(dBuV/m) 48.03 47.42 60.38 50.63 57.47 45.96 43.97 45.85 50.55 60.31 55.18 46.69 Limit
(dBuV/m) 74.00 74.00 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 74.00 54.00 Margin
(dB)
-25.97
-26.58
-13.62
-3.37
-16.53
-8.04
-30.03
-28.15
-3.45
-13.69
-18.82
-7.31 Ant. Pol H/V V V V V V V H H H H H H Remark Peak Peak Peak AVG Peak AVG Peak Peak AVG peak peak AVG 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded (ie:
margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 37 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Operation Mode: TX / CH Mid Temperature:
Humidity:
26C 56 % RH Freq.
(MHz) 1988.000 2794.000 4880.000 4880.925 7318.110 7320.000 N/A 1358.000 2170.000 2748.000 4879.100 4880.000 7320.000 7321.700 N/A Remark:
Reading
(dBuV) 49.04 48.73 57.99 47.40 33.34 46.36 52.03 49.24 48.80 40.28 52.42 44.69 32.80 Correct Factor
(dB/m)
-1.49
-2.06 3.92 3.94 10.63 10.64
-7.98
-3.63
-2.94 6.79 6.81 11.72 11.71 Aug. 13, 2012 Test Date:
Tested by: Clark Su Polarity:
Ver. / Hor. Result
(dBuV/m) 47.55 46.67 61.91 51.34 43.97 57.00 44.05 45.61 45.86 47.07 59.23 56.41 44.51 Limit
(dBuV/m) 74.00 74.00 74.00 54.00 54.00 74.00 74.00 74.00 74.00 54.00 74.00 74.00 54.00 Margin
(dB)
-26.45
-27.33
-12.09
-2.66
-10.03
-17.00
-29.95
-28.39
-28.14
-6.93
-14.77
-17.59
-9.49 Ant. Pol H/V V V V V V V H H H H H H H Remark Peak Peak peak AVG AVG peak Peak Peak Peak AVG peak peak AVG 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded (ie:
margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 38 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Operation Mode: TX / CH High Temperature:
Humidity:
26C 56 % RH Freq.
(MHz) 1356.000 2058.000 4960.000 4960.890 7440.000 7441.415 N/A 1356.000 2180.000 2924.000 4960.000 4960.900 7440.000 7441.505 N/A Remark:
Reading
(dBuV) 51.85 50.48 57.32 46.77 45.67 35.55 52.78 49.15 47.86 51.79 42.10 45.62 35.17 Correct Factor
(dB/m)
-7.51
-2.62 4.94 4.95 11.40 11.40
-8.03
-3.60
-1.47 7.41 7.42 11.14 11.14 Aug. 13, 2012 Test Date:
Tested by: Clark Su Polarity:
Ver. / Hor. Result
(dBuV/m) Limit
(dBuV/m) 44.34 47.86 62.26 51.72 57.07 46.95 44.75 45.55 46.39 59.20 49.52 56.76 46.31 74.00 74.00 74.00 54.00 74.00 54.00 74.00 74.00 74.00 74.00 54.00 74.00 54.00 Margin
(dB)
-29.66
-26.14
-11.74
-2.28
-16.93
-7.05
-29.25
-28.45
-27.61
-14.80
-4.48
-17.24
-7.69 Ant. Pol H/V V V V V V V H H H H H H H Remark Peak Peak peak AVG peak AVG Peak Peak Peak peak AVG peak AVG 1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. 2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using peak/average detector mode. 3. Average test would be performed if the peak result were greater than the average limit or as required by the applicant. 4. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with N/A remark, if no specific emissions from the EUT are recorded (ie:
margin>20dB from the applicable limit) and considered that's already beyond the background noise floor. This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 39 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 7.7 POWERLINE CONDUCTED EMISSIONS LIMIT According to 15.207(a), except as shown in paragraphs (b) and (c) of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit applies at the boundary between the frequency ranges. Frequency Range
(MHz) 0.15 to 0.50 Limits
(dBV) Quasi-peak 66 to 56*
0.50 to 5 5 to 30 56 60
* Decreases with the logarithm of the frequency. TEST CONFIGURATION Average 56 to 46*
46 50 See test photographs attached in Appendix II for the actual connections between EUT and support equipment. TEST PROCEDURE 1. The EUT was placed on a table, which is 0.8m above ground plane. 2. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 3. Repeat above procedures until all frequency measured were complete. TEST RESULTS The initial step in collecting conducted data is a spectrum analyzer peak scan of the measurement range. Significant peaks are then marked as shown on the following data page, and these signals are then quasi-peaked. TEST DATA Not applicable (Since the EUT is powered by battery) This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 40 Rev.00
1 | Test setup photos | Test Setup Photos | 343.76 KiB | August 31 2012 |
Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 9. APPENDIX II PHOTOGRAPHS OF TEST SETUP Radiated Emission Set up Photos Below 1GHz This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 43 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Above 1GHz This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 44 Rev.00 Compliance Certification Services Inc. Report No.: T120803D05-RP1 FCC ID: P27SZDWS01 Date of Issue: Aug. 17, 2012 Conducted Emission Setup Photos This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Page 45 Rev.00
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-08-31 | 2405 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-08-31
|
||||
1 | Applicant's complete, legal business name |
Sercomm Corporation
|
||||
1 | FCC Registration Number (FRN) |
0015548027
|
||||
1 | Physical Address |
8F, No. 3-1, YuanQu St, NanKang
|
||||
1 |
Taipei, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@babt.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
P27
|
||||
1 | Equipment Product Code |
SZDWS01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
N******** W****
|
||||
1 | Title |
Engineer
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
N******@SERCOMM.COM
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ZigBee Door Window Sensor | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter RF Exposure procedures. End users must be informed of the requirements for satisfying RF Exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services Inc.
|
||||
1 | Name |
K****** C****
|
||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
k******@ccsrf.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2405.00000000 | 2480.00000000 | 0.1700000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC