FCC Radio Test Report FCC ID: P27SZWTD02N This report concerns (check one): Original Grant Class II Change Project No. Equipment Model Name Applicant Address Date of Receipt Date of Test Issued Date Tested by
: 1507162
: Zigbee Water Sensor
: SZ-WTD02Nxxxxxxxx (the 1st x should be blank or
-; the rest x could be 0 to 9, A to Z, blank or -, for marking purpose)
: Sercomm Corporation
: 8F, No. 3-1, YuanQu St., NanKang, Taipei, Taiwan 115
: Nov. 27, 2014 Jul. 20, 2015
: Nov. 27, 2014~ Dec. 19, 2014 Jul. 20, 2015 ~ Aug. 21, 2015
: Aug. 24, 2015
: BTL Inc. Testing Engineer Technical Manager Authorized Signatory
:
:
:
(Rush Kao)
(Jeff Yang)
(Andy Chiu) B T L I N C . B1, No.37, Lane 365, Yang Guang St., Nei-Hu District, Taipei City 114, Taiwan. TEL:+886-2-2657-3299 FAX: +886-2- 2657-3331 Report No.: BTL-FCCP-1-1507162 Page 1 of 54 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. BTL's reports apply only to the specific samples tested under conditions. It is manufactures responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTLs report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTLs authorized written approval. and accredited by the conformity assessment authorities listed in this test report. test report is (are) included in the conformity assessment authorities acceptance respective. BTLs laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this Report No.: BTL-FCCP-1-1507162 Page 2 of 54 Table of Contents Page 4 . EMC EMISSION TEST 3 . GENERAL INFORMATION 1 . CERTIFICATION 2 . SUMMARY OF TEST RESULTS 4.1 RADIATED EMISSION MEASUREMENT 2.1 TEST FACILITY 2.2 MEASUREMENT UNCERTAINTY 4.1.1 RADIATED EMISSION LIMITS 4.1.2 TEST PROCEDURE 4.1.3 DEVIATION FROM TEST STANDARD 4.1.4 TEST SETUP 4.1.5 EUT TEST CONDITIONS 4.1.6 TEST RESULTS (9KHZ TO 30MHZ) 4.1.7 TEST RESULTS (BETWEEN 30MHZ TO 1000 MHZ) 4.1.8 TEST RESULTS (ABOVE 1000 MHZ) 6 7 8 8 9 9 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 12 13 13 13 14 14 15 16 16 17 17 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 6.1.1 TEST PROCEDURE 6.1.2 DEVIATION FROM STANDARD 6.1.3 TEST SETUP 6.1.4 EUT OPERATION CONDITIONS 6.1.5 EUT TEST CONDITIONS 6.1.6 TEST RESULTS 5.1.1 TEST PROCEDURE 5.1.2 DEVIATION FROM STANDARD 5.1.3 TEST SETUP 5.1.4 EUT OPERATION CONDITIONS 5.1.5 EUT TEST CONDITIONS 5.1.6 TEST RESULTS 5.1 APPLIED PROCEDURES / LIMIT 6.1 APPLIED PROCEDURES / LIMIT 6 . MAXIMUM OUTPUT POWER TEST 5 . BANDWIDTH TEST Report No.: BTL-FCCP-1-1507162 Page 3 of 54 Table of Contents Page 8.1 APPLIED PROCEDURES / LIMIT 7.1 APPLIED PROCEDURES / LIMIT 8 . POWER SPECTRAL DENSITY TEST 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 7.1.1 TEST PROCEDURE 7.1.2 DEVIATION FROM STANDARD 7.1.3 TEST SETUP 7.1.4 EUT OPERATION CONDITIONS 7.1.5 EUT OPERATION CONDITIONS 7.1.6 TEST RESULTS 8.1.1 TEST PROCEDURE 8.1.2 DEVIATION FROM STANDARD 8.1.3 TEST SETUP 8.1.4 EUT OPERATION CONDITIONS 8.1.5 EUT TEST CONDITIONS 8.1.6 TEST RESULTS 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 22 9 . MEASUREMENT INSTRUMENTS LIST 23 10 . EUT TEST PHOTO 26 ATTACHMENT A - RADIATED EMISSION (9KHZ TO 30MHZ) ATTACHMENT B - RADIATED EMISSION BETWEEN (30MHZ TO 1000MHZ) 28 ATTACHMENT C - RADIATED EMISSION (ABOVE 1000MHZ) 31 44 ATTACHMENT D - BANDWIDTH 47 ATTACHMENT E - MAXIMUM OUTPUT POWER TEST ATTACHMENT F - ANTENNA CONDUCTED SPURIOUS EMISSION 48 52 ATTACHMENT G - POWER SPECTRAL DENSITY TEST Report No.: BTL-FCCP-1-1507162 Page 4 of 54 Issued No. BTL-FCCP-1-1507162 REPORT ISSUED HISTORY Description Original Issue. Issued Date Aug. 24, 2015 Report No.: BTL-FCCP-1-1507162 Page 5 of 54
: Zigbee Water Sensor
: Sercomm Corporation 9, A to Z, blank or -, for marking purpose) 1. CERTIFICATION Equipment Brand Name : Sercomm Model Name : SZ-WTD02Nxxxxxxxx (the 1st x should be blank or -; the rest x could be 0 to Applicant Manufacturer : SERCOMM CORP Address Factory Address Date of Test Test Sample : ENGINEERING SAMPLE Standard(s) The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1507162) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s).
: 3F 81 YUYI RD CHU-NAN MIAO-LI, 350 TAIWAN
: SERCOMM CORP
: 3F 81 YUYI RD CHU-NAN MIAO-LI, 350 TAIWAN
: Nov. 27, 2014~ Dec. 19, 2014 Jul. 20, 2015 ~ Aug. 21, 2015
: FCC Part15, Subpart C :2014 (15.247) / ANSI C63.4-2014 Report No.: BTL-FCCP-1-1507162 Page 6 of 54 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s):
Applied Standard(s): FCC Part15 (15.247) , Subpart C Standard(s) Section Test Item Judgment Remark 15.207 15.247(d) 15.247(a)(2) 15.247(b)(3) 15.247(e) 15.203 15.209/15.205 Conducted Emission Antenna conducted Spurious Emission 6dB Bandwidth Peak Output Power Power Spectral Density Antenna Requirement Transmitter Radiated Emissions N/A PASS PASS PASS PASS PASS PASS NOTE:
(1) N/A denotes test is not applicable to this device. Report No.: BTL-FCCP-1-1507162 Page 7 of 54 2.1TEST FACILITY The test facilities used to collect the test data in this report:
Radiated emission Test:
CB08: (VCCI RN: R-4259; FCC RN:965108; FCC DN:TW1082; IC Assigned Code:20088) No. 68-1, Ln. 169, Sec.2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan 2.2MEASUREMENT UNCERTAINTY The measurement uncertainty is not specified by FCC/Industry Canada rules and for reference only. The reported uncertainty of measurement y U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The measurement instrumentation uncertainty considerations contained in CISPR 16-4-2. The BTL measurement uncertainty is less than the CISPR 16-4-2 Ucispr requirement. A. Radiated emission test:
Test Site Method Measurement Frequency Range CB08
(10m) CISPR 30 MHz ~ 200 MHz 30 MHz ~ 200 MHz 200 MHz ~ 1, 000 MHz 200 MHz ~ 1, 000 MHz Ant. H / V U, (dB) 4.04 V H 4.04 4.08 V H 4.02 NOTE Test Site CB08
(3m) Method CISPR Measurement Frequency Range 1 ~ 6 GHz 6 ~18 GHz U, (dB) 4.62 4.88 NOTE Our calculated Measurement Instrumentation Uncertainty is shown in the tables above. These are our Ulab values in CISPR 16-4-2 terminology. Since Table 1 of CISPR 16-4-2 has values of measurement instrumentation uncertainty, called UCISPR, as follows:
Conducted Disturbance (mains port) 150 kHz 30 MHz: 3.6 dB Radiated Disturbance (electric field strength on an open area test site or alternative test site) 30 MHz 1000 MHz: 5.2 dB It can be seen that our Ulab values are smaller than UCISPR. If Ulab is less than or equal to UCISPR, then:
compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
non-compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit. If Ulab is greater than UCISPR, then:
compliance is deemed to occur if no measured disturbance level, increased by (Ulab - UCISPR), non-compliance is deemed to occur if any measured disturbance level, increased by (Ulab - UCISPR), exceeds the disturbance limit;
exceeds the disturbance limit. Report No.: BTL-FCCP-1-1507162 Page 8 of 54 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Brand Name Model Name Model Difference Product D scription Power Source Power Rating Zigbee Water Sensor Sercomm SZ-WTD02Nxxxxxxxx (the 1st x should be blank or -; the rest x could be 0 to 9, A to Z, blank or -, for marking purpose) The 1st x should be blank or -; the rest x could be 0 to 9, A to Z, blank or -, for marking purpose. Operation Frequency 2405~2480 MHz Modulation Technology Bit Rate of Transmitter Output Power (Max.) Supplied from AA Battery*2 DC 3V OQPSK 250Kbps 3.53 dBm Note:
1. For a more detailed features description, please refer to the manufacturers specifications or the User's Manual. 2. Channel 11 12 13 14 15 16 17 18 Frequency
(MHz) 2405 2410 2415 2420 2425 2430 2435 2440 Channel 19 20 21 22 23 24 25 26 Frequency
(MHz) 2445 2450 2455 2460 2465 2470 2475 2480 3. Ant. 1 Brand Model Name Antenna Type Connector Gain (dBi) SERCOM SZ-WTD02 Internal N/A 3.51 Report No.: BTL-FCCP-1-1507162 Page 9 of 54 3.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Mode 1 Description TX Mode NOTE (1) Final Test Mode Mode 1 For Radiated Test Description TX Mode NOTE (1) Note:
(1) The measurements are performed at the high, middle, low available channels. Report No.: BTL-FCCP-1-1507162 Page 10 of 54 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING During testing channel & power controlling software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the firmware of the final end product power parameters of WLAN Test Software Version Frequency (MHz)
-
2405 0 N/A 2445 0 2480 0 Report No.: BTL-FCCP-1-1507162 Page 11 of 54 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED EUT 3.5 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item
-
Equipment Mfr/Brand Model/Type No. FCC ID/IC Series No.
-
-
-
-
-
Note
-
Item Shielded Type Ferrite Core Length
-
-
-
-
Note
-
Note:
(1) For detachable type I/O cable should be specified the length in m inLengthcolumn. Report No.: BTL-FCCP-1-1507162 Page 12 of 54 4. EMC EMISSION TEST 4.1 RADIATED EMISSION MEASUREMENT 4.1.1 RADIATED EMISSION LIMITS In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. LIMITS OF RADIATED EMISSION MEASUREMENT (9KHz-1000MHz) Frequency
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 960~1000 Field Strength
(microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance
(meters) 300 30 30 3 3 3 3 LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz) Frequency (MHz) Above 1000 Notes:
(dBuV/m) (at 3 meters) PEAK 74 AVERAGE 54
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m).
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use) Margin Level = Measurement Value - Limit Value Spectrum Parameter Attenuation Start Frequency Stop Frequency RBW / VBW Setting Auto 1000 MHz 10th carrier harmonic RBW 1MHz VBW 3MHz peak detector for Pk value
(Emission in restricted band) RMS detector for AV value Report No.: BTL-FCCP-1-1507162 Page 13 of 54 Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9KHz~90KHz for PK/AVG detector 90KHz~110KHz for QP detector 110KHz~490KHz for PK/AVG detector 490KHz~30MHz for QP detector 30MHz~1000MHz for QP detector 4.1.2 TEST PROCEDURE a. The measuring distance of at 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 0.8 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(below 1GHz) b. The measuring distance of at 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 1.5 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(above 1GHz) c. The height of the equipment or of the substitution antenna shall be 0.8 m or 1.5m, the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights find the maximum reading (used Bore sight function). e. The receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1GHz. f. The initial step in collecting conducted emission data is a receiver peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didnt perform.
(below 1GHz) h. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT shall be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured, but AVG Mode didnt perform. (above 1GHz) i. For the actual test configuration, please refer to the related Item - Block Diagram of system tested (please refer to 3.3). 4.1.3 DEVIATION FROM TEST STANDARD No deviation Report No.: BTL-FCCP-1-1507162 Page 14 of 54 4.1.4 TEST SETUP
(A) Radiated Emission Test Set-Up Frequency Below 1 GHz EUT 0.8 m Absorbers 3 m Ground Plane 1-4 m 1 m Receiver Amp.
(B) Radiated Emission Test Set-Up Frequency Above 1 GHz Report No.: BTL-FCCP-1-1507162 Page 15 of 54
(C) For radiated emissions below 30MHz 4.1.5 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: DC 3V 4.1.6TEST RESULTS (9KHZ TO 30MHZ) Please refer to the Attachment A. Remark:
(1) The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported.
(2) Distance extrapolation factor = 40 log (specific distance / test distance) (dB).
(3) Limit line = specific limits (dBuV) + distance extrapolation factor. Report No.: BTL-FCCP-1-1507162 Page 16 of 54 4.1.7TEST RESULTS (BETWEEN 30MHZ TO 1000 MHZ) Please refer to the Attachment B. Remark:
(1) Measuring frequency range from 30MHz to 1000MHz.
(2) If the peak scan value lower limit more than 20dB, then this signal data does not show in table. 4.1.8TEST RESULTS (ABOVE 1000 MHZ) Please refer to the Attachment C. Remark:
(1) Radiated emissions measured in frequency range above 1000MHz were made with an instrument using Peak detector mode and AV detector mode of the emission
(2) A preamp and high pass filter were used for this test in order to provide sufficient measurement sensitivity.
(3) EUT Orthogonal Axis:
X - denotes Laid on TableY - denotes Vertical StandZ - denotes Side Stand
(4) During the measurements above 1 GHz it is taken care of that the EUT is always within the 3 dB cone of radiation BW of the used antenna
(5) No limit: This is fundamental signal, the judgment is not applicable. For fundamental signal judgment was referred to Peak output test. Report No.: BTL-FCCP-1-1507162 Page 17 of 54 5. BANDWIDTH TEST 5.1 Applied procedures / limit FCC Part15 (15.247) , Subpart C Section Test Item Limit 15.247(a)(2) Bandwidth 5.1.1 TEST PROCEDURE
>= 500KHz
(6dB bandwidth) Frequency Range
(MHz) Result 2405~2480 MHz PASS a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram below, b. Spectrum Setting : RBW= 100KHz, VBW=300KHz, Sweep time = 2.5 ms. 5.1.2 DEVIATION FROM STANDARD No deviation. 5.1.3 TEST SETUP 5.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 Unless otherwise a special operating condition is specified in the follows during the testing. 5.1.5 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: DC 3V 5.1.6 TEST RESULTS Please refer to the Attachment D. Report No.: BTL-FCCP-1-1507162 Page 18 of 54 6. MAXIMUM OUTPUT POWER TEST 6.1 Applied procedures / limit FCC Part15 (15.247) , Subpart C Section Test Item Limit Frequency Range
(MHz) Result 15.247(b)(3) Maximum Output Power 6.1.1 TEST PROCEDURE 1 watt or 30dBm 2405~2480 MHz PASS a. The EUT was directly connected to the power meter and antenna output port as show in the block diagram below, b. The maximum peak conducted output power was performed in accordance with method 9.1.2 of FCC KDB 558074 D01 DTS Meas Guidance v03r02. 6.1.2 DEVIATION FROM STANDARD No deviation. 6.1.3 TEST SETUP 6.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 Unless otherwise a special operating condition is specified in the follows during the testing. Transmit output power was measured while the host equipment supply voltage was varied from 85 % to 115 % of the nominal rated supply voltage. No change in transmit output power was observed. 6.1.5 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: DC 3V 6.1.6 TEST RESULTS Please refer to the Attachment E. Report No.: BTL-FCCP-1-1507162 Page 19 of 54 7. ANTENNA CONDUCTED SPURIOUS EMISSION 7.1 Applied procedures / limit In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. 7.1.1 TEST PROCEDURE a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram below, b. Spectrum Setting : RBW= 100KHz, VBW=300KHz, Sweep time = 10 ms. c. Offset=antenna gain + cable loss 7.1.2 DEVIATION FROM STANDARD No deviation. 7.1.3 TEST SETUP 7.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 Unless otherwise a special operating condition is specified in the follows during the testing. 7.1.5 EUT OPERATION CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: DC 3V 7.1.6 TEST RESULTS Please refer to the Attachment F. Report No.: BTL-FCCP-1-1507162 Page 20 of 54 8. POWER SPECTRAL DENSITY TEST 8.1 Applied procedures / limit FCC Part15 (15.247) , Subpart C Section Test Item Limit 15.247(e) Power Spectral Density 8 dBm
(in any 3KHz) 8.1.1 TEST PROCEDURE Frequency Range
(MHz) Result 2405~2480 MHz PASS a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in b. Spectrum Setting: RBW=3KHz, VBW=10 KHz, Sweep time = auto. the block diagram below, 8.1.2 DEVIATION FROM STANDARD No deviation. 8.1.3 TEST SETUP 8.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 Unless otherwise a special operating condition is specified in the follows during the testing. 8.1.5 EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: DC 3V 8.1.6 TEST RESULTS Please refer to the Attachment G. Report No.: BTL-FCCP-1-1507162 Page 21 of 54 9. MEASUREMENT INSTRUMENTS LIST Agilent Microwave Pre_amplifier Microflex Cable Harbour industries Microflex Cable Microflex Cable Harbour industries EMC Horn Antenna Item Kind of Equipment 1 Spectrum Analyzer 2 3 4 5 6 7 8 9 10 Log-Bicon Antenna 11 12 Test Cable Test Cable Pre-Amplifier Horn Antenna Loop Antenna Radiated Emission Measurement Manufacturer R&S Type No. FSP-40 Schwarzbeck BBHA 9120 Serial No. 100129 D-325 8449B 3008A01714 27478LL142 S104-SMA 27478LL142 LMR-400 LMR-400 MH648A VULB9168-35 2 1m 8m 3m 10m 3m M92649 9168-352 BBHA 9170 187 6502 00042960 LMR LMR Anritsu Schwarzbeck Schwarzbeck EMCO Calibrated until Jan. 07, 2016 Apr. 20, 2016 Apr. 13, 2016 Apr. 13, 2016 May. 14, 2016 May. 13, 2016 May. 13, 2016 May. 13, 2016 Jun. 16, 2016 Jul. 30, 2016 Mar. 22, 2016 Sep. 06, 2015 6dB Bandwidth Measurement Item Kind of Equipment 1 Spectrum Analyzer Manufacturer R&S Type No. FSP-40 Serial No. 100129 Calibrated until Oct. 12, 2015 Item 1 2 Kind of Equipment Power Meter Sensor Signal Generator Peak Output Power Measurement Manufacturer Anritsu R&S Type No. MA2411B SMR40 Serial No. 1126001 100502 Calibrated until Aug. 07, 2016 Aug. 07, 2016 Antenna Conducted Spurious Emission Measurement Item Kind of Equipment Manufacturer 1 Spectrum Analyzer R&S Type No. FSP-40 Serial No. 100129 Calibrated until Oct. 12, 2015 Item Kind of Equipment 1 Spectrum Analyzer R&S Type No. FSP-40 Serial No. 100129 Calibrated until Oct. 12, 2015 Power Spectral Density Measurement Manufacturer Remark: N/A denotes no model name, serial no. or calibration specified. All calibration period of equipment list is one year. Report No.: BTL-FCCP-1-1507162 Page 22 of 54 10. EUT TEST PHOTO Radiated Measurement Photos 9KHz to 30MHz Report No.: BTL-FCCP-1-1507162 Page 23 of 54 Radiated Measurement Photos 30M to 1000MHz Report No.: BTL-FCCP-1-1507162 Page 24 of 54 Radiated Measurement Photos Above 1000MHz Report No.: BTL-FCCP-1-1507162 Page 25 of 54 ATTACHMENT A - RADIATED EMISSION (9KHZ TO 30MHZ) Report No.: BTL-FCCP-1-1507162 Page 26 of 54 Test Mode:
Test Date TX Mode Aug. 18, 2015 Reading(RA) Corr.Factor(CF) Measured(FS)
(dBuV/m) Freq.
(MHz) 0.0150 0.0150 0.0255 0.0255 0.0366 0.0366 0.0600 0.0600 1.2650 1.1353 Freq.
(MHz) 0.0132 0.0132 0.0257 0.0257 0.0345 0.0345 0.0632 0.0632 1.2510 1.6500 Ant. 0/90 0 0 0 0 0 0 0 0 0 0 Ant. 0/90 90 90 90 90 90 90 90 90 90 90
(dBuV) 32.24 43.20 28.99 33.25 24.87 32.65 24.68 34.92 33.58 38.54
(dBuV) 33.65 48.84 27.16 42.48 26.13 35.93 22.85 38.16 34.42 36.34 Limits(QP)
(dBuV/m) 104.08 124.08 99.47 119.47 96.33 116.33 92.04 112.04 65.56 66.50 Limits(QP)
(dBuV/m) 105.19 125.19 99.41 119.41 96.85 116.85 91.59 111.59 65.66 63.25 Margin
(dB)
-49.57
-58.61
-48.47
-64.21
-49.73
-61.95
-46.12
-55.88
-11.65
-7.50 Margin
(dB)
-49.22
-54.03
-50.24
-54.92
-48.93
-59.13
-47.55
-52.24
-10.89
-6.96 Note AVG PK AVG PK AVG PK AVG PK QP QP Note AVG PK AVG PK AVG PK AVG PK QP QP
(dB) 22.28 22.28 22.01 22.01 21.74 21.74 21.24 21.24 20.34 20.46
(dB) 22.32 22.32 22.01 22.01 21.79 21.79 21.19 21.19 20.35 19.95 54.52 65.48 51.00 55.26 46.61 54.39 45.92 56.16 53.92 59.00 55.97 71.16 49.17 64.49 47.92 57.72 44.04 59.35 54.77 56.29 Reading(RA) Corr.Factor(CF) Measured(FS)
(dBuV/m) Report No.: BTL-FCCP-1-1507162 Page 27 of 54 ATTACHMENT B - RADIATED EMISSION BETWEEN (30MHZ TO 1000MHZ) Report No.: BTL-FCCP-1-1507162 Page 28 of 54 Test Mode:
Test Date TX 2445MHz -CH19 Aug. 17, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 29 of 54 Test Mode:
Test Date TX 2445MHz -CH19 Aug. 17, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 30 of 54 ATTACHMENT C - RADIATED EMISSION (ABOVE 1000MHZ) Report No.: BTL-FCCP-1-1507162 Page 31 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2405MHz _CH11 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 32 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2405MHz _CH11 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 33 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2405MHz _CH11 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 34 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2405MHz _CH11 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 35 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2445MHz _CH19 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 36 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2445MHz _CH19 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 37 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2445MHz _CH19 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 38 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2445MHz _CH19 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 39 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2480MHz _CH26 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 40 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2480MHz _CH26 Aug. 19, 2015 Vertical Report No.: BTL-FCCP-1-1507162 Page 41 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2480MHz _CH26 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 42 of 54 Orthogonal Axis : X Test Mode :
Test Date TX 2480MHz _CH26 Aug. 19, 2015 Horizontal Report No.: BTL-FCCP-1-1507162 Page 43 of 54 ATTACHMENT D - BANDWIDTH Report No.: BTL-FCCP-1-1507162 Page 44 of 54 Test Date Dec. 11, 2014 Frequency
(MHz) 2405 2445 2480 6dB Bandwidth
(MHz) 1.589 1.581 1.605 99% Occupied BW
(MHz) 1.908 1.908 1.904 TX CH11 Min. Limit
(kHz) 500 500 500 Test Result Complies Complies Complies Report No.: BTL-FCCP-1-1507162 Page 45 of 54 TX CH19 TX CH26 Report No.: BTL-FCCP-1-1507162 Page 46 of 54 ATTACHMENT E - MAXIMUM OUTPUT POWER TEST Test Date Dec. 11, 2014 Frequency
(MHz) 2405 2445 2480 Conducted Power (dBm) 2.67 2.58 3.53 Conducted Power
(Watt) 0.0018 0.0018 0.0023 Max. Limit
(dBm) 30.00 30.00 30.00 Max. Limit
(Watt) 1.00 1.00 1.00 Test Result Complies Complies Complies Report No.: BTL-FCCP-1-1507162 Page 47 of 54 ATTACHMENT F - ANTENNA CONDUCTED SPURIOUS EMISSION Report No.: BTL-FCCP-1-1507162 Page 48 of 54 Test Mode :
Test Date CH11, CH19 , CH26 Dec. 11, 2014 CH11 (Lower) CH26 (upper) Report No.: BTL-FCCP-1-1507162 Page 49 of 54 CH11 (10 Harmonic of the frequency) CH19 (10 Harmonic of the frequency) Report No.: BTL-FCCP-1-1507162 Page 50 of 54 CH26 (10 Harmonic of the frequency) Report No.: BTL-FCCP-1-1507162 Page 51 of 54 ATTACHMENT G - POWER SPECTRAL DENSITY TEST Report No.: BTL-FCCP-1-1507162 Page 52 of 54 Test Date Dec. 11, 2014 Frequency
(MHz) 2405 2445 2480 Power Density
(dBm)
-12.11
-11.66
-12.54 Max. Limit
(dBm) 8 8 8 TX CH11 Result Complies Complies Complies Report No.: BTL-FCCP-1-1507162 Page 53 of 54 TX CH19 TX CH26 Report No.: BTL-FCCP-1-1507162 Page 54 of 54