ZB4001(45856) ZigBee,InWallOn/OffSwitch HomeAutomationStandardVersion1.2Compliant Introduction ThankyouforyourpurchaseofaJascoZigBeecontrolleddevice.JascosZigBeelightingcontrolsare designedtoautomatelighting/homecontrolandprovideeasyremoteoperationofallyourZigBee enableddevices.TheJascoZigBeeproductfamilyincludesavarietyofdevicestocontrollightinginyour home.Itisuptoyouwhetheryouwanttocontroloneroomoryourentirehouseandwhetheryouwant todoitallnoworstartwithoneroomandaddmoreovertime. ThedevicecontrolledbytheZigBeeInWallOn/OffSwitchmustnotexceed900watts(Incandescent);
1440W(12A)ResistiveorHPMotor. Therearenouserserviceablepartsinthisunit.
!Warning!
RISKOFFIRE RISKOFELECTRICALSHOCK RISKOFBURNS NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT ZigBee enabled devices should never be used to supply power to or control the On/Off status of medical and/
or life support equipment!
WARNING ControllingAppliances:
ExerciseextremecautionwhenusingZigBeedevicestocontrolappliances.OperationoftheZigBeedevicemay beinadifferentroomthanthecontrolledappliance,alsoanunintentionalactivationmayoccurifthewrong buttononthecontrollerinterfaceispressed.ZigBeedevicesmayautomaticallybepoweredonduetotimed eventprogramming.Dependingupontheappliance,theseunattendedorunintentionaloperationscouldpossibly resultinahazardous. 1. DoNotincludeZigBeedevicesinGroupsorScenesiftheycontrolappliances. 2. DoNotuseZigBeedevicestocontrolelectricheatersoranyotherapplianceswhichmaypresentahazardous conditionduetounattendedorunintentionalorautomaticpoweroncontrol. KeyFeatures TurntheconnecteddeviceOn/OffmanuallyorviatwoZigBeecontroller CanbeIncludedinmultipleGroupsandScenes MaybeusedinsinglepoleinstallationorwithuptothreeJascoauxiliaryswitchesin2way,3 wayor4waywiringconfigurations InterchangeablePaddleswitch:White&lightalmondpaddleinpackage OvertheAirupdatesOncejoinedtoyourZigBeenetwork,thedevicecantransparentlyreceive updatesthroughyourZigBeegateway EnergyMonitoringThedevicecanreportwattage(W)andkilowatthours(kWh).Energyusage ismonitoredthroughtheZigBeeControllerInterface Usesastandard,decorasizewallplateforsingleganginstallations(wallplatenotincluded) BlueLEDindicatesswitchlocationinadarkroom(LEDcanbeenabled/disabledmanually) LEDStatusIndicatorIndicatesdevicescanningduringpairingprocess ZigBeeHA1.2Certifiedforsimplepairingandintegratedhomeautomation ScrewTerminalinstallation;requireswiringconnectionsforLine(Hot),Load,Neutral,and Ground.Travelerwirerequiredformultipoleinstallation To change color of the switch 1. LifttheAirGaptabatthebaseofthecover. 2. Pushsidetabsinononesideandthentheothertoreleasecover.Liftthecoverupandoff. 3. Simplyputthenewcoverontotheswitchbyinsertingtheairgapandsidetabsandsnappingsecurely intoplace. Installation Thisswitchmaybeusedinnewinstallationsortoreplaceanexistingwallswitch.Itmaybeusedbyitself for2waycontrol(oneswitch&oneload),withoneJascoAuxiliarySwitchfor3waycontrol(two switches&oneload)orwithtwoJascoAuxiliaryswitchesfor4waycontrol(threeswitches&oneload). Whenusedbyitselffor2waycontrol,pleasemakesurethatthescrewterminalforthetravelerwireis insulated(DoNotRemovethetapeovertheterminalifyouarenotusingthetravelerconnection) WARNINGSHOCKHAZARD TurnOFFthepowertothebranchcircuitfortheswitchand lightingfixtureattheservicepanel.Allwiringconnectionsmust bemadewiththePOWEROFFtoavoidpersonalinjuryand/or damagetotheswitch. CONNECTIONS TWOWAYCONTROL SINGLESWITCHWIRINGUSINGONEPRIMARY SWITCH THREEWAYCONTROL TWOSWITCHWIRINGUSINGONEPRIMARY ANDONEAUXILIARYSWITCH FOURWAYCONTROL THREESWITCHWIRINGUSINGONEPRIMARYANDTWOAUXILIARYSWITCHES Single,DualandTripleGangBoxes WheninstallingtheInWallOn/Offswitchinmultiplegangboxesitmaybenecessarytobreakoffoneor bothofthescoredtabsonthefrontyoke.Thisdoesnotaffecttheelectricalratingoftheswitch. ObserveImportantWiringInformation Important:Thisswitchisratedforandintendedtoonlybeusedwithcopperwire. Thehomeselectricalwiresmaybeattachedtothescrewterminalsorinsertedintotheholesinthe backoftheswitchenclosureandclampedinplacebytighteningthescrewterminals.Alwaysfollowthe recommendedwirestriplengthswhenmakingwiringconnections. Wiregaugerequirements Use14AWGorlargerwiressuitableforatleast80Cforsupply(HOT),Load,Neutral,Groundand Travelerconnections. Wirestriplength:
Forattachmenttoscrewterminals:Stripinsulation1in(25mm) Forattachmentusingtheenclosuresholes:Stripinsulation5/8(16mm) ULspecifiesthatthetighteningtorqueforthescrewsis14Kgfcm(12lbfin). SINGLESWITCHWIRING 1.Shutoffpowertothecircuitatfuseboxorcircuitbreaker. 2.Removewallplate.
!Warning:VerifypowerisOFFtoswitchboxbeforecontinuing. 3.Removetheswitchmountingscrews. 4.Carefullyremovetheswitchfromtheswitchbox.DONOTdisconnectthewires. 5.Therearefivescrewterminalsontheswitch;thesearemarked LINE(Hot) Neutral GROUND TRAVELER LOAD TheTravelerterminalisonlyusedfor3wayor4waywiringandshouldremaininsulatediftheswitchis beinginstalledina2waysystem(oneswitch&oneload).Matchthesescrewterminalstothewires connectedtotheexistingswitch. 6.Disconnectthewiresfromtheexistingswitch. 7.ConnectthegreenorbarecoppergroundwiretotheGROUNDterminal. 8.ConnecttheblackwirethatgoestothelighttotheterminalmarkedLOAD. 9.Connecttheblackwirethatcomesfromtheelectricalservicepanel(Hot)totheterminalmarked LINE. 10.Connectthewhitewiretotheneutralterminal. Note:ULspecifiesthatthetighteningtorqueforthescrewsis14Kgfcm(12lbfin). 11.InsertSwitchintotheswitchboxbeingcarefulnottopinchorcrushwires. 12.Securetheswitchtotheboxusingthesuppliedscrews. 13.Mountthewallplate. 14.Reapplypowertothecircuitatfuseboxorcircuitbreakerandtestthesystem. OPTIONALforTHREEorFOURWAYCONTROL:
ConnecttheTravelerwire(usuallyRed)tothescrewterminalmarkedTRAVELERontheprimaryswitch
(DoNotremovethetapeovertheterminalifyouarenotusingthetravelerconnection).Theotherend ofthisTravelerwireconnectstotheTRAVELERscrewterminalontheAuxiliarySwitch. 1. Theauxiliaryrequiresthefollowing3wiringconnections:
a. TheTravelerwire.Thisisusedtosendvoltagesignalstotheprimaryswitch.Thesignalstellthe switchwhatactiontoperform. b. Ground. c. Neutral. 2. DONOTconnecttheauxiliaryswitchtothehomesblackHot(Line)wire. Oncetheswitchisproperlywired,youshouldbeabletousetherockertomanuallyturnOn/Offthe connectedload BasicOperation TheconnectedlightcanbeturnedON/OFFintwoways:
1. Manuallyfromthefrontpaneloftheinwallswitch 2. RemotelywithaZigBeeController MANUALCONTROL TheFrontPanelRockerSwitchallowstheuserto:
TurnON/OFFtheconnectedlighting. ToturntheconnectedlightingON:Tapthetopoftherocker. ToturntheconnectedlightingOFF:Tapthebottomoftherocker. REMOTECONTROL ZigBeedevicescanbecontrolleddirectlybyyourZigBeeControllerandremotelyoverlongdistances withaPCormobilephoneappifyourhomescontrollerfunctionsasagatewayconnectedtoan internetrouter. TocontrolthedeviceremotelyitmustbepairedtotheZigBeeControllerasinstructed ZigBeeNetworkPairing JointheswitchtotheZigBeeNetwork 1. FromyourZigBeeControllersinterface,choosetoaddlightingdeviceandenter Locating/Pairingmodeasinstructedbythecontroller. 2. AfterapplyingpowertotheInWallswitch,yourInWallSwitchwillbeginautoscanmodeasit searchesforacontrollertopairwith AutoScan:LEDStatusIndicatorBlinks3xevery10secondsasthedevicescansfora compatiblenetworkcontrollertopairwithuntilTimeout. Timeout:AutoScanmodewilleventuallytimeoutaftertheLEDStatuslightstops blinking.IfdeviceTimeoutoccursbeforetheswitchhasjoinedtheZigBeenetwork, pressanybuttonontheswitchtoresumescanning. 3. AftertheswitchislocatedandpairedtotheZigBeenetwork,theLEDStatusIndicatorwillstop blinkingandtheswitchwillappearinyourcontrollersmenu.SetuptheswitchasanOn/Off controlandtitletheswitchinawaythatwillbeeasytoidentify. ThemoduleisnowpairedtotheZigBeenetworkandcanbecontrolledremotely. ResetDevice(RemovefromZigBeeNetwork) FromtheZigBeeController Fromyourcontrollerorhubinterface,choosetoremoveordeletethelightingdeviceasinstructed.The devicewillberemovedfromtheZigBeenetworkfollowingindicationfromyourcontroller.All configurationparameterswillberesetafterthedeviceisremovedfromthenetwork. Manual TomanuallyresetandremovethedevicefromtheZigBeenetwork,TapTopofRocker(ONSwitch)10x quickly(shortpresses) LEDParameters Toassistwithlocatingtheswitchinadarkroom,theLEDglowsbluewhenthelightswitchisturnedOFF. ToturnLEDoff:
Taptoprocker(ONSwitch)3xquicklyandthentapbottomrocker(OFFSwitch)1x TorestoreLED:
UsethesameseriesofbuttonpressesusedtodisabletheLEDtorestore WARRANTY JASCOProductswarrantsthisproducttobefreefrommanufacturingdefectsforaperiodoftwoyearsfromthe originaldateofconsumerpurchase.Thiswarrantyislimitedtotherepairorreplacementofthisproductonlyand doesnotextendtoconsequentialorincidentaldamagetootherproductsthatmaybeusedwiththisproduct.This warrantyisinlieuofallotherwarranties,expressedorimplied.Somestatesdonotallowlimitationsonhowlong animpliedwarrantylastsorpermittheexclusionorlimitationofincidentalorconsequentialdamage,sotheabove limitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights,andyoumayalsohaveotherrightswhich varyfromstatetostate.PleasecontactCustomerServiceat8006548483(option1)between7:30AM5:00PM CSTorviaourwebsite(www.jascoproducts.com)iftheunitshouldprovedefectivewithinthewarrantyperiod. FCCandICCompliance U2ZZB4001 TheFederalCommunicationCommissionRadioFrequencyInterferenceStatementincludesthe followingparagraph:
TheequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst harmfulinterferenceinaresidentialinstallation.Thisequipmentuses,generates,andcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstruction,maycauseharmful interferencetoradiocommunication.However,thereisnoguaranteethatinterferencewillnotoccurin aparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevision reception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotry tocorrecttheinterferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna Increasetheseparationbetweentheequipmentandreceiver Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected Consultthedealeroranexperiencedradio/TVtechnicianforhelp Operationissubjecttothefollowingtwoconditions:
Thisdevicemaynotcauseinterference Thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesired operationofthedevice. ImportantNote:TocomplywiththeFCCRFexposurecompliancerequirements,nochangetothe antennaorthedeviceispermitted.Anychangetotheantennaorthedevicecouldresultinthedevice exceedingtheRFexposurerequirementsandvoidusersauthoritytooperatethedevice. Caution: Exposure to Radio Frequency Radiation. To comply with FCC/IC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter. CompliancewithICRulesand RegulationsIC:6924AZB4001 JascoProductsCompany Model:ZB4001(45856) CANICES3(B)/NMB3(B) This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. OPERATINGSPECIFICATIONS Power120VAC,60Hz Signal(Frequency)2.4GhzIEEE802.15.4 MaximumloadfortheZigBeecontrolledInWallSwitch:
o 900WIncandescent o HPMotoror12Amp,1440WResistive OperatingTemperatureRange:32104F(040C) Forindooruseonly. ComplieswithFCCandIndustryCanadaregulations JASCOProducts 10E.MemorialRd OklahomaCity,OK73114 www.jascoproducts.com ZigBeeisaregisteredUStrademarkoftheZigBeeAlliance Theimages,productinformationandspecificationslistedinthisdocumentarepreliminaryandsubject tochange