Function Deployment Operation Main Unit and Remote Control Charging of Main Unit 439 User Manual 3 EYE & HEAD MASSAGER For relief of minor aches and pains Thank you for purchasing Breo iDream3. Please read this manual carefully before using the product, and keep it in a safe place for future reference. Introduction iDream3 adopts air pressure, vibration, and hot compress massaging technology to massage the head and ocular regions. It comes with a wireless remote control and built-in MP3 player. You can now enjoy wonderful music while massaging, further relaxing your head and eyes. Inside the package 1 Main Unit, 1 Controller, 1 Power Charger, 3 Batteries, 1 User Manual, 1 Set of Earphones, 1 USB Cable 11. 10. 7. 8. 6. 1. 2. 3. 4. 9. 5. 1. 2. 3. 4. 5. 6. LCD Screen ON/Off Operating Buttons Air discharge Pressure Reduction Valve DC power interface DC Power Port Earphone Jack 7. 8. 9. 10. 11. Power Switch Protection key Encoding Key USB Port Size Adjusting Knob Tightness Adjusting Knob LCD ScreenFrom top to bottom: Time /Air Pressure/Vibration/Hot Compress/Music Operating Button:Clockwise: Up Button/Function Mode Next/Down Button
/Function Mode Previous Center: OK Button Power switch protection key: Push left or right to turn ON/OFF MUST push power switch to Level O after each use Attention:
In case of problem with connection between the main unit and remote control, you can perform joint encoding operation:
1. Turn the remote control off, and push the power switch of the main unit to level O;
Press and hold [8] encoding key of the main unit. While still holding it, push the power switch of the main unit to level I to turn it on;
The blue LED indicator on the front of the main unit ashes. Release [8] encoding key, and simultaneously press the keys of the remote control for 2-3 seconds. The remote control LCD lights up while the main units blue LED indicator turns off-it means the encoding is successful (This step should be completed within 6 seconds). If unsuccessful, repeat from the start. Push the power switch of the main unit to level O, then back to level I. Both the main unit and remote control should now be working. and 2. 3. Please make sure that one main unit is corresponding to one remote controller. The operation of encoding joint with multiply remote controller to the main unit is prohibited. Important: Make sure that only one device is paired with the remote control. Multiple pairing of remote control and main unit is strictly prohibited. Main Unit Controller Preparation Prior to use, check the integrity of the machine and accessories:
1. 2. No damage on power charger Battery power is sufcient Power Charger Earphones USB Cable Manual Batteries 1. 2. 3. Open the cover of the DC power port on the main unit. Insert the plug of the power charger to the DC port. During charging, the light of the power charger is red. The light turns green when fully charged. Attention:
1. 2. 3. Push the power switch on the main unit to Level O. Keep the massager turned OFF while charging. Charging time is approximately 3-4 hours. If the massager is turned on while recharging, all functions of the product will run normally. The machine will automatically stop charging to prevent damage to the device. If the power of the battery is lower than 3.2 0.1V, the machine will automatically turn off. If the LED indicator of the main unit ashes, it means the lithium battery is low. Recharge the main unit.
Operation Automatic Mode (without the remote control) Power On/Off 1. 2. Power ON Push the ON/OFF switch on the main unit to Level I (Picture2) No need of remote control. The main unit starts working after 8 seconds. Preset default is air pressure + heat compression + music + 15 minutes duration. Power OFF The main unit automatically shuts off after 15 minutes. Push the ON/OFF switch on the main unit to Level O. Manual Mode (using the remote control Power On/Off 1. Power ON: Push the ON/OFF switch on the main unit to Level I (Picture2) The main unit is powered by a high performance, environment-friendly lithium battery. Press and hold Button on the remote control Preset default is air pressure + heat compression + music + 15 minutes duration Default air pressure: Mode 5 circulates among Modes 1 to 4;
Default hot compress: low temperature;
Default Music: Well-being music Power OFF: Press Button on the remote control. Push the ON/OFF switch on the main unit to Level O 2. 3. 4. Manually operate related buttons to select air pressure mode, vibration mode, hot compress temperature, change music and/or massage duration. among functions Press Button to choose
(Time, Air Pressure, Vibration, Heat, and Music) Press Button to turn on/off a function Press Button to select air pressure mode, vibration mode, hot compress temperature, change music and/or massage duration Time Press Button to select Time Press Button to select massage duration 15 minutes/10 minutes/5 minutes Air pressure Press Button to select Air Pressure Press Button to select from the 5 different modes of air pressure
(Preset Default: Mode 5 circulates among Modes 1 to 4) Off/On: Press Button to turn off/on Air Pressure Heat compression Press Button to select Heat Compression Press Button to select low temperature or high temperature Off/On: Press Button to turn off/on Heat Compression Vibration Press Button to select Vibration,then Press Button Press Button to select from the 5 different modes of vibration Off/On: Press Button to turn off/on Vibration Music Press Button to select Music,then Press Button Press Button to go to the next one
(Preset Default circulates among pre-recorded music) Press Button to go to the previous one Press and hold Button: Volume up Press and hold Button: Volume down Off/On: Press Button to turn off/on Music Press and hold Button to switch over between built-in music and MP3 music Music Downloading 1. 2. 3. Connect the main unit to computer using the supplied USB cable;
Push the power protection key on the main unit to Level I;
Copy MP3 music to the device. Wear 1. 2. Use the back dial to adjust the distance between head to establish the most comfortable t, and wear main unit. Use the top dial in setting the distance above head. Power on 1. 2. 3. Open the battery cover on the back of the remote control. Place 3 AAA batteries in accordance with the positive and negative poles. Close the battery cover. (Picture1)
(picture 2) to Level I
(picture 1) Attention:
When you feel the air pressure is too much and/or uncomfortable, press the Pressure Reduction Valve on the main unit to release air. Precautions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Please read the manual carefully and operate accordingly. Children under 7 years old cannot use the massager. This massager should not be used by:
a. People who suffer from brain disease or have undergone brain surgery b. People who are suffering from glaucoma, retinoschisis or other serious eye diseases c. People who have physical or mental disorder Take off contact lenses/eye glasses before use. Put on/wear the unit rst BEFORE turning the power on. Do not use while walking or driving. Keep your eyes closed for a few seconds after use, then open them slowly. Keep the massager away from humidity, heat, and/or corrosive gas. If the massager will not be used for a long time, remove the batteries to avoid battery leakage. This massager features heat compression. Individuals who are incapable of or do not ordinarily feel heat/cold sensation should use this device with caution. To clean, wipe with aseptic cotton and alcohol. Do not wash or immerse in water. This product is not a substitute for healthcare professionals' advice and treatment. In case of doubt or if necessary, please consult your healthcare professional. Please use ONLY the DC4.5V power charger that comes with the package, and handle it with care. It is very IMPORTANT to turn the power of the main unit OFF after each use and before storage to avoid damage to the machine. 15. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Please note that changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate 16. the equipment. 17. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio ommunications. However, there is no guarantee that interference will not occur in a will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to ry to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help Troubleshooting When operational problems occur, please refer to the chart below. Do not disassemble the machine or try to repair it by yourself. Problem Possible Reason Possible Solution Power Switch Protection key is not turned on Push this key to Level I Lithium battery of the main unit is low Recharge the main unit at once Power-On Failure Remote control batteries are low/ out Change batteries Remote control batteries are not installed correctly Check if positive/negative poles of batteries are positioned right Make sure the batteries are snug in place Weak air pressure or vibration Lithium battery of the main unit is low Recharge the main unit at once Specications DC/Power DC: 4.5V Power: 4.5W Ideal Environment Dimension Temperature 540 Relative Humidity 80%
Atmospheric Pressure: 860hpa1060hpa Main UnitL282mm X W206mm X H254mm Controller L132mm X W44mm X H24mm Net Weight 1125g Storage 1. 2. 3. If left unused, checking the product/turning the power on every 6 months is recommended. Do not store near the oor, wall or roof. Maintain good ventilation and keep away from direct sunlight and corrosive gases. Made in China Manufactured by: Shenzhen Breo Technology, Co., Ltd. Company Address: Jinshan Bldg., No. 5033, Shennan East Road, Shenzhen, 518008, China