CR-Scan Ferret Pro 3D Scanner Quick Start Guide Small Build Great Capture 1. Specification Product Model Technology Working distance Operation Temperature Single Capture Range Single- frame Precision Minimum point distance/Resolution Applicable scenario Light Source Scanner Dimensions Data transmission CR-Scan Ferret Pro/ Gemini 2 Scan Pro CRS04F RC541SM Dual Camera Infrared Light 150mm 700mm 0-40 820mm x 560mm@700mm Up to 0.1mm 0.16mm Indoor/ Outdoor scanning <30000Lux@ 0.4m Class1 NIR 120*30*26mm USB3.0 Type-C, WIFI6 Wireless bridge Specification Wireless Bridge WBF1 110g 125*62*18mm USB3.0 Type-C USB Type-C 2.2W Wi-Fi 6 Red: Error, Yellow: Firmware update; Green: Power on;
Blue: Wi-Fi ready 0C to 40C Product Model Weight Dimensions Data interface Power connection Power consumption Wi-Fi LED indicators status Operation Temperature 2.Packing List 1. Rechargeable Handle *
2. CR-Scan Ferret Pro Scanner 3. Wireless Bridge 4. Tripod 5. Phone Holder 6. Power Cable for Wireless Bridge
*[Power Button] One click: ON, Double click: OFF 7. Data Cable for Wireless Bridge 8. Quick Mount Kit 9. USB Cable for Smartphone& Handle 10. USB Cable for Computer 11. Type-C Adapter 12. Carrying Case 3.System Requirements System Requirements PC: i5-Gen8 CPU and above Windows: Windows10/11 (64-bit) RAM: 8G and above Mac: M1/M2 series processor macOS Big Sur 11.7.7 and above RAM: 8G and above Mac: Intel processor (i5-Gen8 CPU and above) macOS Catalina 10.15.7 and above RAM: 8G and above Android: Android 10.0 and above RAM: 8G and above iPhoneiPhone11 and above IOSIOS13 and above
* For better scanning performance, PC is recommended. Software& firmware link:
Creality Google play https://www.creality.com/pages/download-cr-scan-ferret https://play.google.com/store/apps/details?id=com. creality.crealityscan 3.Device Attachment Connecting Ferret Pro to PC via USB cable Turntable mode installation PC Connection Connecting Ferret Pro to Phones via Wi-Fi Handheld mode installation with wireless bridge Wireless bridge connection Connect the Smartphone to the wireless bridge:
1)Connect the wireless bridge to the scanner and rechargeable handle, wait a few seconds until the LED turn blue 2)Go to your smartphones Wi-Fi setting, search for the network called Ferret-XXXXXX and connect (No password is required). 3) Wait a few seconds for the scanner to be connected Facebook Group A place to discuss, share, trouble shoot Tutorials Master the art of scanning!
Wireless Bridge LED Indicators LED Indicator No light: Power off Green light: Power on Yellow light: Firmware update Red light: Initiation/Error Blue light: Wi-Fi ready Connecting Ferret Pro to Android Phones via USB cable Handheld mode installation without wireless bridge USB cable connection to Android Phones Warning Due to the used enclosure material, the product shall only be connected to a USB Interface of version 2.0 or higher. The connection to so called power USB is prohibited. Do not use the product in the environment at too high or too low temperature, never expose the product under strong sunshine or too wet environment. The suitable temperature for the product and accessories is 0-40. This device is a low-power radio transmitter and receiver. As recommended by international guidelines, the device meets applicable national SAR limits of 2.0W/kg (10g).10g SAR: meets low-power exclusion level, SAR test is not required. RF band/RF power Operation Frequency WLAN 5G: 5180 MHZ-5240 MHZ WLAN 5G: 5745 MHZ-5825 MHZ Max.EIRP 14.76dBm 13.87dBm EU Regulatory Conformance Hereby, Orbbec Inc. declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. This product can be used across EU member states. Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement, The device can be used in portable exposure condition without restriction. Federal Communication Commission (FCC) Radiation Exposure Statement Power is so low that no RF exposure calculation is needed. 5GHz Shenzhen Creality 3D Technology Co.,Ltd. Company Address:18F, JinXiuHongDu Building, Meilong Blvd., Longhua Dist., Shenzhen,China 518131