all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user manual | Users Manual | 181.46 KiB | June 08 2019 | |||
1 |
|
internal photos | Internal Photos | 377.53 KiB | June 08 2019 | |||
1 |
|
external photos | External Photos | 402.65 KiB | June 08 2019 | |||
1 |
|
label | ID Label/Location Info | 94.05 KiB | June 08 2019 | |||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 15.60 KiB | June 08 2019 | |||
1 |
|
RF exposure | RF Exposure Info | 87.45 KiB | June 08 2019 | |||
1 | block diagram | Block Diagram | August 06 2019 | confidential | ||||
1 |
|
confidentiality request letter | Cover Letter(s) | 15.23 KiB | June 08 2019 | |||
1 | operation description | Operational Description | August 06 2019 | confidential | ||||
1 | schematics | Schematics | August 06 2019 | confidential | ||||
1 |
|
test report | Test Report | 4.34 MiB | June 08 2019 | |||
1 |
|
test setup photos | Test Setup Photos | 151.93 KiB | June 08 2019 |
1 | user manual | Users Manual | 181.46 KiB | June 08 2019 |
Alexa-Enabled Thermometer and Hygrometer Model No. TP-90 Quick Start Congratulations on your purchase of asmart, wirelessAlexa-enabledindoorThermometer/Hygrometer. This Alexa-enabled Thermo Prodevice not only quickly and accurately broadcasts the temperature and humidity of each room, it allows you to be able to conveniently look up historic temperature and humidity readings from any location via an APP installed on your cellphone. When you ask Alexa the temperature and humidity of a room, Alexa will respond you by announcing the current temperature and humidity retrieved from the device. Buttons:
Power: Press to turn on/offdevice. DIM: Press to adjust the brightness of the LED display. F/C: Press to switch the temperature unit between Fahrenheit and Celsius. RESET: Press and hold for 5 seconds to enter EZ or AP pairing modes. Followthe simple steps below to set up your smart Alexa-EnabledThermometer/Hygrometer. You need to install and setup both the Thermo Pro Home APP and Amazon Alexa APP. Step 1. Search for Thermo Pro Home on the Apple Store for IOS devices or on the Google Play Store for Android devices. Download the App and install it on your smartphone. Step 2: Open the Thermo Pro Home App, and you will be asked to register a Thermo Pro account. Step 3: Once your account is setup, power on the Thermo Pro thermometer/hygrometer device and follow the instructions in the APP to add the sensors. Please note:
1. The device can be added via two pairing modes, EZ mode and AP mode. You should try using EZ mode first to add the device. If you have trouble in adding devices using EZ mode, then switch to using AP mode to add the devices. 2. Currently, these devices only support 2.4GHz Wi-Fi network. Do NOT select a 5Ghz Wi-Fi network. Step 4: You may add as many devices as you wish but ensure you name them different names. For example, you can place one device in the master bedroom and name that device, Master Bedroom.Another device in living room and name that device, Living Room. Step 5: Search the Google Play Store or Apple App Store for an APP called Amazon Alexa and install it onto your smartphone. If your smartphone already has Amazon Alexa APP installed, please skip this step. Step 6. Open the Amazon Alexa APP and search for the Skill called Thermo Pro and ENABLE this Skill. After you press ENABLE, it will ask you to enter your Thermo Pro Home APP account ID and password. If done successfully, Thermo Pro has been successfully linked should appear. If you couldnt successfully link the device, please go back to the Thermo Pro Skill, press SETTINGS and then press Link Account and enter your Thermo Pro Home APP account ID/password. Done! Test with the following command Alexa, ask Thermo Pro, whats the temperature in the (devices name)?
The below is a list of Voice Commands you can ask Alexa:
If you have any questions or need more help with setup, please feel free to contact us:
CUSTOMER SERVICE Email: service@buythermopro.com Telephone:
US/Canada: 1 877 515 7797 Mon-Fri 8:00 AM 8:00 PM (EST). UK: +44 20 3769 1321 Mon-Fri 12:00 PM 10:00 PM (GMT). Germany:+49 2115469003 Mon-Fri 1:00 PM - 11:00 PM (CET) France: +33 975129576 Mon-Fri 1:00 PM - 11:00 PM (CET) Italy: +39 05231715570 Mon-Fri 1:00 PM - 11:00 PM (CET) Spain: +34 910601787 Mon-Fri 1:00 PM - 11:00 PM (CET) LIMITED ONE-YEAR WARRANTY Thermo Pro warrants this product to be free of defects in parts, materials and workmanship for a period of one year, from date of purchase. Should any repairs or servicing under this warranty be required, contact Customer Service by phone or email for instructions on how to pack and ship the product to Thermo Pro. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. FCCCaution Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2) thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment. Note: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Bdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedto providereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation. Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmfulinterference toradiocommunications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferenceto radioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoff andon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures:
-Reorientorrelocatethereceivingantenna.
-Increasetheseparationbetweentheequipmentandreceiver.
-Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforan uncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwith minimumdistance20cmbetweentheradiator&yourbody.
1 | label | ID Label/Location Info | 94.05 KiB | June 08 2019 |
Label Location Size:30*20mm Model: TP-90 FCC ID: 2AATP-TP90 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
1 | Power of Attorney Letter | Cover Letter(s) | 15.60 KiB | June 08 2019 |
(SHENZHEN ECARE ELECTRONICS CO.,LTD. ) Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date:
SUBJECT: FCC Application for FCC ID: 2AATP-TP90 To Whom It May Concern:
We, the undersigned, hereby authorize Andy Yuan at Shenzhen BCTC Testing Co., Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Andy Yuan of Shenzhen BCTC Testing Co., Ltd. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards,
(Martina Yang)
1 | RF exposure | RF Exposure Info | 87.45 KiB | June 08 2019 |
Shenzhen BCTC Testing Co., Ltd. FCC ID: 2AATP-TP90 RF EXPOSURE EVALUATION 1. Introduction According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in 1.1307(b), a device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 cm is normally maintained between the transmitting antenna and the body of the user or nearby persons. In this context, the term fixed location means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 cm separation requirement. The limits to be used for MPE evaluation are specified in 1.1310. All unlicensed personal communications service (PCS) devices and unlicensed NII devices shall be subject to the limits for general population/uncontrolled exposure. 2.RF Radiation Exposure Limits According to 47 CFR 1.1310, the criteria listed in below table shall be used to evaluate the environmental impact of human exposure to RF radiation as specified in 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of 2.1093. Notes: 1. f = frequency in MHz 2. Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided they are made aware of the potential for exposure. 3. General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Shenzhen BCTC Testing Co., Ltd. 3.MPE Assessment Method Calculations can be made to predict RF field strength and power density levels around typical RF sources. For example, in the case of a single radiating antenna, a prediction for power density in the far-field of the antenna can be made by use of the general Equations below. This equation is generally accurate in the far-field of an antenna but will over-predict power density in the near field, where they could be used for making a "worst case" or conservative prediction. Where S = Power Density, unit in mW/cm2 P = Power input to the antenna, unit in mW G = Power gain of the antenna in the direction of interest relative to an isotropic radiator R = Distance to the center of radiation of the antenna, unit in cm EIRP = Effective isotropically radiated power 4. MPE Calculation for Standalone Operations Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz Power density limited: 1mW/ cm2 Antenna Type: PCB antenna Antenna gain: 1dBi R=20cm mW=10^(dBm/10)
=3.1415926 802.11b/g/n:
Modulation Channel Freq.
(MHz) Conduct ed power
(dBm) 802.11b 802.11g 802.11n20 2412 2437 2462 2412 2437 2462 2412 2437 2462 9.35 9.65 9.27 8.16 8.87 8.73 8.02 7.76 7.78 Tune-up power
(dBm) Max tune-up power
(dBm) Max tune-up power
(mW) 91 91 91 81 81 81 71 71 71 10.00 10.00 10.00 9.00 9.00 9.00 8.00 8.00 8.00 10.00 10.00 10.00 7.94 7.94 7.94 6.31 6.31 6.31 Antenna Gain Numeric Evaluation result
(mW/cm2 ) Power density Limits
(mW/cm2) 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 0.00251 0.00251 0.00251 0.00199 0.00199 0.00199 0.00158 0.00158 0.00158 1 1 1 1 1 1 1 1 1 Conclusion:
For the max result : 0.00251 1.0, compliance with FCC's RF Exposure. Summary: Since the ERP (effective radiated power) operated at < 1.5 GHz is less than 1.5 watts and > 1.5 GHz is less than 3 watts, the routine environmental evaluation is not required, and the MPE result calculated for this device complies with the MPE limit as specified in 47 CFR 1.1310.
1 | confidentiality request letter | Cover Letter(s) | 15.23 KiB | June 08 2019 |
(SHENZHEN ECARE ELECTRONICS CO.,LTD. ) Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:
2AATP-TP90 Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, we hereby request confidential treatment of information accompanying this application as outlined below:
Exhibit Type Block Diagram, Schematics, Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely,
(Martina Yang) File Name Block Diagram Schematics Operational Description Rev 11/20/07
1 | test report | Test Report | 4.34 MiB | June 08 2019 |
Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E FCC Part 15C Test Report FCC ID: 2AATP-TP90 Product Name: Alexa Enabled Thermometer and Hygrometer Trademark:
N/A Model Name :
TP-90 Prepared For :
SHENZHEN ECARE ELECTRONICS CO., LTD Address :
5-6/F., Block B, Huali Industrial Building District 28, Bao An Shenzhen, Guang Dong 518133, China Prepared By :
Shenzhen BCTC Testing Co., Ltd. Address :
BCTC Building & 1-2F, East of B Building, Pengzhou Industrial, Fuyuan 1st Road, Qiaotou Community, Fuyong Street, Baoan District, Shenzhen, China Test Date:
Jul. 19, 2019 to Jul. 30, 2019 Date of Report :
Jul. 30, 2019 Report No.:
BCTC-LH190700623E Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 1 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TEST RESULT CERTIFICATION Applicants name ............... Address ............................... Manufacture's Name .......... Address ............................... Product description Product name.......................... Trademark ............................... Model and/or type reference ........................... Standards ........................... SHENZHEN ECARE ELECTRONICS CO., LTD 5-6/F., Block B, Huali Industrial Building District 28, Bao An Shenzhen, Guang Dong 518133, China SHENZHEN ECARE ELECTRONICS CO., LTD 5-6/F., Block B, Huali Industrial Building District 28, Bao An Shenzhen, Guang Dong 518133, China Alexa Enabled Thermometer and Hygrometer N/A TP-90 FCC Part15.247 ANSI C63.10:2013 This device described above has been tested by BCTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of BCTC, this document may be altered or revised by BCTC, personal only, and shall be noted in the revision of the document. Prepared by(Engineer):
Cai Fang Zhong Reviewer(Supervisor):
Eric Yang Approved(Manager):
Zero Zhou Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 2 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Table of Contents Page 3 . EMC EMISSION TEST 2 . GENERAL INFORMATION 1 . SUMMARY OF TEST RESULTS 3.1 CONDUCTED EMISSION MEASUREMENT 1.1 TEST FACILITY 1.2 MEASUREMENT UNCERTAINTY 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 3.1.2 TEST PROCEDURE 3.1.3 DEVIATION FROM TEST STANDARD 3.1.4 TEST SETUP 3.1.5 EUT OPERATING CONDITIONS 3.1.6 TEST RESULTS 6 7 7 8 8 2.1 GENERAL DESCRIPTION OF EUT 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 13 13 13 13 13 14 14 15 17 17 17 18 18 19 20 21 23 26 26 26 27 27 27 29 3.2.1 RADIATED EMISSION LIMITS 3.2.2 TEST PROCEDURE 3.2.3 DEVIATION FROM TEST STANDARD 3.2.4 TEST SETUP 3.2.5 EUT OPERATING CONDITIONS 3.2.6 TEST RESULTS (BETWEEN 9KHZ 30 MHZ) 3.2.7 TEST RESULTS (BETWEEN 30MHZ 1GHZ) 3.2.8 TEST RESULTS (1GHZ~25GHZ) 3.3.1 TEST REQUIREMENT:
3.3.2 TEST PROCEDURE 3.3.3 DEVIATION FROM TEST STANDARD 3.3.4 TEST SETUP 3.3.5 EUT OPERATING CONDITIONS 4 . POWER SPECTRAL DENSITY TEST 3.3 RADIATED BAND EMISSION MEASUREMENT 3.2 RADIATED EMISSION MEASUREMENT Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 3 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Table of Contents Page 4.1 APPLIED PROCEDURES / LIMIT 4.1.1 TEST PROCEDURE 4.1.2 DEVIATION FROM STANDARD 4.1.3 TEST SETUP 4.1.4 EUT OPERATION CONDITIONS 4.1.5 TEST RESULTS 5 . BANDWIDTH TEST 5.1 APPLIED PROCEDURES / LIMIT 5.1.1 TEST PROCEDURE 5.1.2 DEVIATION FROM STANDARD 5.1.3 TEST SETUP 5.1.4 EUT OPERATION CONDITIONS 5.1.5 TEST RESULTS 6 . PEAK OUTPUT POWER TEST 6.1 APPLIED PROCEDURES/LIMIT 6.1.1 TEST PROCEDURE 6.1.2 DEVIATION FROM STANDARD 6.1.3 TEST SETUP 6.1.4 EUT OPERATION CONDITIONS 6.1.5 TEST RESULTS 7 . 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 7.1 APPLICABLE STANDARD 7.2 TEST PROCEDURE 7.3 DEVIATION FROM STANDARD 7.4 TEST SETUP 7.5 EUT OPERATION CONDITIONS 7.6 TEST RESULT 8 . DUTY CYCLE OF TEST SIGNAL 8.1 STANDARD REQUIREMENT 8.2 FORMULA:
9 . ANTENNA REQUIREMENT 9.1 STANDARD REQUIREMENT 9.2 EUT ANTENNA 29 29 29 29 29 30 36 36 36 36 36 36 37 43 43 43 43 43 43 44 45 45 45 45 45 45 45 52 52 52 55 55 55 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 4 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Table of Contents 10 . EUT TEST PHOTO 11 . EUT PHOTO APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Page 56 58 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 5 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards:
Standard Section 15.207 FCC Part15 (15.247) , Subpart C Test Item Judgment Remark Conducted Emission 15.247 (a)(2) 6dB Bandwidth 15.247 (b) 15.247 (d) 15.247 (e) 15.205 Peak Output Power Radiated Spurious Emission Power Spectral Density Restricted Band of Operation 15.247 (d) Band Edge (Out of Band Emissions) 15.203 Antenna Requirement NOTE:
(1) N/A denotes test is not applicable in this Test Report PASS PASS PASS PASS PASS PASS PASS PASS Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 6 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 1.1 TEST FACILITY Shenzhen BCTC Testing Co., Ltd. Add. : BCTC Building & 1-2F, East of B Building, Pengzhou Industrial, Fuyuan 1st Road, Qiaotou Community, Fuyong Street, Baoan District, Shenzhen, China FCC Test Firm Registration Number: 712850 IC Registered No.: 23583 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y Uwhere expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2providing a level of confidence of approximately 95 %
No. 1 2 3 4 5 6 7 8 Item 3m camber Radiated spurious emission(30MHz-1GHz) 3m chamber Radiated spurious emission(1GHz-18GHz) 3m chamber Radiated spurious emission(18GHz-40GHz) Conducted Adjacent channel power Conducted output power uncertainty Above 1G Conducted output power uncertainty below 1G humidity uncertainty Temperature uncertainty Uncertainty U=4.3dB U=4.5dB U=3.34dB U=1.38dB U=1.576dB U=1.28dB U=5.3%
U=0.59 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 7 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Trade Name Model Name Model Difference Alexa Enabled Thermometer and Hygrometer N/A TP-90 N/A Operation Frequency:
Modulation Type:
Bit Rate of Transmitter 802.11b:11/5.5/2/1 Mbps 802.11b/g/n20MHz:2412~2462 MHz WIFI: OFDM/DSSS 802.11g:54/48/36/24/18/12/9/6Mbps 802.11n Up to 150Mbps 802.11b/g/n20MHz:11 CH Product Description Number Of Channel Antenna Designation: Please see Note 3. Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Please refer to the Note 2. MODEL: XS-0500300HU INPUT: 100-240V 50/60Hz 0.3A OUTPUT: 5V 300mA Channel List Adapter Connecting I/O Port(s) Please refer to the User's Manual Hardware Version:
Software Version:
Note:
V120 A1.0 1. For a more detailed features description, please refer to the manufacturers specifications or the User's Manual. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 8 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 2. Channel 01 02 03 Frequency
(MHz) 2412 2417 2422 3. Table for Filed Antenna Channel List for 802.11b/g/n(20) Channel 04 05 06 Frequency
(MHz) 2427 2432 2437 Channel 07 08 09 Frequency
(MHz) 2442 2447 2452 Channel 10 11 Frequency
(MHz) 2457 2462 Ant. 1 Brand N/A Model Name N/A Antenna Type PCB antenna Gain (dBi) NOTE 1 2.2 DESCRIPTION OF TEST MODES Pretest Mode Mode 1 Mode 2 Mode 3 Mode 4 Final Test Mode Mode 4 Final Test Mode Mode 1 Mode 2 Mode 3 Description 802.11b CH1/ CH6/ CH11 802.11g CH1/ CH6/ CH11 802.11n20 CH1/ CH6/ CH11 Link Mode Conducted Emission Description Link Mode For Radiated Emission Description 802.11b CH1/ CH6/ CH11 802.11g CH1/ CH6/ CH11 802.11n20 CH1/ CH6/ CH11 Note:
(1) The measurements are performed at all Bit Rate of Transmitter, the worst data was reported. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 9 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Conducted Emission Test E-1 EUT C-1 AC Adapter E-2 Radiated Spurious Emission Test 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. No. E-1 E-2 Device Type Brand Model Series No. NOTE Alexa Enabled Thermometer and N/A TP-90 N/A EUT Hygrometer Adapter Item Shielded Type Ferrite Core C-1 NO NO N/A Length 0.4M XS-0500 300HU N/A EUT Note DC cable unshielded Note:
(1)
(2) The support equipment was authorized by Declaration of Confirmation. For detachable type I/O cable should be specified the length in cm inLengthcolumn. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 10 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS Radiation Test equipment Item Manufacturer Type No. Agilent E4407B Last Serial No. calibration Calibrated until MY45109572 Jun. 13, 2019 Jun. 12, 2020 Equipment Spectrum Analyzer
(9kHz-26.5GHz) Test Receiver
(9kHz-7GHz) Bilog Antenna
(30MHz-3GHz) Horn Antenna
(1GHz-18GHz) Horn Antenna
(18GHz-40GHz) Amplifier
(9KHz-6GHz) Amplifier
(0.5GHz-18GHz) Amplifier 1 2 3 4 5 6 7 8 R&S ESR7 101154 Jun. 13, 2019 Jun. 12, 2020 SCHWARZBE SCHWARZBE SCHWARZBE SCHWARZBE CK CK CK CK CK SCHWARZBE MITEQ VULB9163 VULB9163-94 BBHA9120D 1541 2 Jun. 22, 2019 Jun. 21, 2020 Jun. 22, 2019 Jun. 21, 2020 BBHA9170 822 Jun. 22, 2019 Jun. 21, 2020 BBV9744 9744-0037 Jun. 25, 2019 Jun. 24, 2020 9718-309 Jun. 25, 2019 Jun. 24, 2020 BBV9718 TTA1840-35-
2034381 9 11 10 CK HG 014 FMZB1519B SCHWARZBE
(18GHz-40GHz) Loop Antenna
(9KHz-30MHz)
(9kHz-30MHz) Huber+Suhnar 9kHz-30MHz B1702988-000 RF cables1 RF cables2 1486150
(30MHz-1GHz) Huber+Suhnar 30MHz-1GHz RF cables3 12
(1GHz-40GHz) Huber+Suhnar 1GHz-40GHz 13 Power Metter Power Sensor 14 15 Signal Analyzer 20kHz-26.5GHz Keysight Keysight E4419 E9 300A KEYSIGHT 1607106 N9020A
(AV)
\
\
8 Jun. 17, 2019 Jun. 16, 2020 Jul. 02, 2019 Jul. 01, 2020 Jun. 25, 2019 Jun. 24, 2020 Jun. 25, 2019 Jun. 24, 2020 Jun. 25, 2019 Jun. 24, 2020 Jun. 17, 2019 Jun. 16, 2020 Jun. 17, 2019 Jun. 16, 2020 MY49100060 Jun. 13, 2019 Jun. 12, 2020 Spectrum Analyzer 9kHz-40GHz D.C. Power Supply Software 16 17 18 Aglient FSP40 100363 Jun. 13, 2019 Jun. 12, 2020 LongWei TPR-6405D
\
Frad EZ-EMC FA-03A2 RE
\
\
\
\
Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 11 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Conduction Test equipment Item Equipment Manufacturer Type No. Serial No. 1 Test Receiver 2 3 4 LISN LISN R&S SCHWARZBEC K R&S ESR3 NSLK8127 ENV216 102075 8127739 101375 RF cables Huber+Suhnar 9kHz-30MHz B1702988-00 EMC-CON Software EZ-EMC Frad 08 3A1 until Last calibration Calibrated Jun. 13, 2019 Jun. 12, 2020 Jun. 13, 2019 Jun. 12, 2020 Jun. 13, 2019 Jun. 12, 2020 Jun. 25, 2019 Jun. 24, 2020
\
\
5 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 12 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3. EMC EMISSION TEST 3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION Limits
(Frequency Range 150KHz-30MHz) FREQUENCY (MHz) 0.15 -0.5 0.50 -5.0 5.0 -30.0 Note:
Limit (dBuV) Quasi-peak Average 56 - 46 *
66 - 56 *
46.00 56.00 60.00 50.00 Standard FCC FCC FCC
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz 3.1.2 TEST PROCEDURE a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the and forth in the center forming a bundle 30 to 40 cm long. cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item EUT Test Photos. 3.1.3 DEVIATION FROM TEST STANDARD No deviation Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 13 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.1.4 TEST SETUP Vertical Reference Ground Plane 40cm EUT LISN 80cm Test Receiver Horizontal Reference Ground Plane Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80 from other units and other metal planes 3.1.5 EUT OPERATING CONDITIONS The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. We pretest AC 120V and AC 240V, the worst voltage was AC 120V and the data recording in the report. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 14 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.1.6 TEST RESULTS 26 101kPa Temperature Pressure Test Voltage AC120V 60Hz Relative Humidity 54%
Phase :
Test Mode L Mode 4 Remark:
1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 15 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Temperature Pressure Test Voltage AC120V 60Hz 26 101kPa Relative Humidity 54%
Phase :
Test Mode N Mode 4 Remark:
1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 16 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.2 RADIATED EMISSION MEASUREMENT 3.2.1 RADIATED EMISSION LIMITS (Frequency Range 9kHz-1000MHz) 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequencies
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength
(micorvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance
(meters) 300 30 30 3 3 3 3 LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz) Limit (dBuV/m) (at 3M) PEAK 74 AVERAGE 54 FREQUENCY (MHz) Above 1000 Notes:
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m). Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (emission in restricted band) Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency 3.2.2 TEST PROCEDURE Setting Auto 1000 MHz 25GHz 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average Setting Auto 9kHz~150kHz / RB 200Hz for QP 150kHz~30MHz / RB 9kHz for QP 30MHz~1000MHz / RB 120kHz for QP Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 17 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E a. The measuring distance of at 3 m shall be used for measurements at frequency up to 25GHz. For frequencies above 1GHz, any suitable measuring distance may be used. b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-chamber test. The table was rotated 360 degrees to determine the position of the highest radiation. c. The height of the equipment or of the substitution antenna shall be 0.8m; above 1GHz, the height was 1.5m, the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. f. For the actual test configuration, please refer to the related Item EUT Test Photos. g. For the radiated emission test above 1GHz:
Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported 3.2.3 DEVIATION FROM TEST STANDARD No deviation 3.2.4 TEST SETUP ARadiated Emission Test-Up Frequency Below 30MHz Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 18 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E BRadiated Emission Test-Up Frequency 30MHz~1GHz CRadiated Emission Test-Up Frequency Above 1GHz 3.2.5 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 19 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E
--
--
3.2.6 TEST RESULTS (BETWEEN 9KHZ 30 MHZ) Temperature Pressure Test Mode 26 101kPa Mode 4 Relative Humidtity Test Voltage Polarization :
54%
AC120V 60Hz
--
Freq.
(MHz)
--
--
Reading
(dBuV/m) Limit
(dBuV/m)
--
--
Margin
(dB)
--
--
State P/F PASS PASS NOTE:
The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB);
Limit line = specific limits(dBuv) + distance extrapolation factor. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 20 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.2.7 TEST RESULTS (BETWEEN 30MHZ 1GHZ) 26 101 kPa Temperature Pressure Test Voltage AC120V 60Hz Test Mode Mode 3 Relative Humidity 54%
Polarization :
Horizontal Remark:
Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 21 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 26 101kPa Temperature Pressure Test Voltage AC120V 60Hz Test Mode Mode 3 Relative Humidity 54%
Polarization :
Vertical Remark:
Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 22 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.2.8 TEST RESULTS (1GHZ~25GHZ) 802.11b Polar
(H/V) Frequency Meter Reading Pre-amplifi er
(MHz)
(dBuV)
(dB) Cable Loss
(dB) Antenna Factor Emission Level Limits Margin
(dB)
(dBuV/m)
(dBuV/m)
(dB) Detector Type V V V V V H H H H H 4824.00 4824.00 7236.00 7236.00 15450.00 4824.00 4824.00 7236.00 7236.00 15450.00 66.53 51.26 67.02 49.33 52.19 67.10 50.98 68.05 49.55 52.22 Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) V V V V V H H H H H 4874.00 4874.00 7311.00 7311.00 15450.00 4874.00 4874.00 7311.00 7311.00 15450.00 67.12 50.39 67.78 50.26 52.15 65.90 50.38 69.13 48.30 52.45 39.55 39.55 38.33 38.33 35.23 39.55 39.55 38.33 38.33 35.45 Pre-amplifi er
(dB) 38.89 38.89 38.78 38.78 35.89 38.89 38.89 38.78 38.78 36.68 Low Channel:2412MHz 7.85 7.85 7.52 7.52 6.75 7.85 7.85 7.52 7.52 6.75 25.66 25.66 24.55 24.55 26.59 25.66 25.66 23.55 23.22 27.88 60.49 45.22 60.76 43.07 50.30 61.06 44.94 60.79 41.96 51.40 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-13.51
-8.78
-13.24
-10.93
-23.70
-12.94
-9.06
-13.21
-12.04
-22.60 PK AV PK AV PK PK AV PK AV PK Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Middle Channel:2437MHz Limits
(dBuV/m) Margin Detector
(dB) Type 7.57 7.57 7.35 7.35 6.42 7.57 7.57 7.35 7.35 6.42 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 61.25 44.52 61.13 43.61 49.15 60.03 44.51 62.48 41.65 48.84 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-12.75
-9.48
-12.87
-10.39
-24.85
-13.97
-9.49
-11.52
-12.35
-25.16 Pk AV Pk AV Pk Pk AV Pk AV Pk Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) Pre-amplifi er
(dB) Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Limits
(dBuV/m) Margin Detector
(dB) Type High Channel: 2462MHz 7.46 7.46 7.22 7.22 6.35 7.46 7.46 7.22 7.22 6.32 38.75 38.75 38.65 38.65 35.58 38.75 38.75 38.65 38.65 36.42 68.36 51.21 67.56 49.19 51.51 64.77 51.82 68.71 49.31 53.05 4924.00 4924.00 7386.00 7386.00 15450.00 4924.00 4924.00 7386.00 7386.00 15450.00 V V V V V H H H H H Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. All the ANT have test, only the worst case reported.
-11.48
-8.63
-13.09
-11.46
-25.25
-15.07
-8.02
-11.94
-11.34
-24.40 62.52 45.37 60.91 42.54 48.75 58.93 45.98 62.06 42.66 49.60 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 PK AV PK AV PK PK AV PK AV PK Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 23 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Polar
(H/V) Frequency Meter Reading
(MHz)
(dBuV) V V V V V H H H H H 4824.00 4824.00 7236.00 7236.00 15450.00 4824.00 4824.00 7236.00 7236.00 15450.00 69.55 52.11 66.39 48.91 52.09 64.95 52.20 69.46 49.70 53.69 Pre-amplifi er
(dB) 39.55 39.55 38.33 38.33 35.23 39.55 39.55 38.33 38.33 35.45 Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) V V V V V H H H H H 4874.00 4874.00 7311.00 7311.00 15450.00 4874.00 4874.00 7311.00 7311.00 15450.00 69.91 53.25 67.69 48.60 50.70 64.29 50.93 70.32 48.59 53.77 Pre-amplifi er
(dB) 38.89 38.89 38.78 38.78 35.89 38.89 38.89 38.78 38.78 36.68 802.11g Cable Loss
(dB) Antenna Factor Emission Level Limits Margin
(dB)
(dBuV/m)
(dBuV/m)
(dB) Detector Type Low Channel:2412MHz 7.85 7.85 7.52 7.52 6.75 7.85 7.85 7.52 7.52 6.75 25.66 25.66 24.55 24.55 26.59 25.66 25.66 23.55 23.22 27.88 63.51 46.07 60.13 42.65 50.20 58.91 46.16 62.20 42.11 52.87 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-10.49
-7.93
-13.87
-11.35
-23.80
-15.09
-7.84
-11.80
-11.89
-21.13 PK AV PK AV PK PK AV PK AV PK Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Middle Channel:2437MHz Limits
(dBuV/m) Margin Detector
(dB) Type 7.57 7.57 7.35 7.35 6.42 7.57 7.57 7.35 7.35 6.42 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 64.04 47.38 61.04 41.95 47.70 58.42 45.06 63.67 41.94 50.16 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-9.96
-6.62
-12.96
-12.05
-26.30
-15.58
-8.94
-10.33
-12.06
-23.84 PK AV PK AV PK PK AV PK AV PK Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) Pre-amplifi er
(dB) Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Limits
(dBuV/m) Margin Detector
(dB) Type High Channel: 2462MHz 7.46 7.46 7.22 7.22 6.35 7.46 7.46 7.22 7.22 6.32 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 38.75 38.75 38.65 38.65 35.58 38.75 38.75 38.65 38.65 36.42 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 63.12 48.32 62.47 41.51 47.86 58.41 45.40 64.48 42.19 49.22 68.96 54.16 69.12 48.16 50.62 64.25 51.24 71.13 48.84 52.67 4924.00 4924.00 7386.00 7386.00 15450.00 4924.00 4924.00 7386.00 7386.00 15450.00 V V V V V H H H H H Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. All the ANT have test, only the worst case reported. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 24 of 59
-10.88
-5.68
-11.53
-12.49
-26.14
-15.59
-8.60
-9.52
-11.81
-24.78 PK AV PK AV PK PK AV PK AV PK Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Polar
(H/V) Frequency Meter Reading
(MHz)
(dBuV) V V V V V H H H H H 4824.00 4824.00 7236.00 7236.00 15450.00 4824.00 4824.00 7236.00 7236.00 15450.00 68.19 55.12 70.10 47.57 49.76 63.52 50.61 70.62 47.52 52.81 Pre-amplifi er
(dB) 39.55 39.55 38.33 38.33 35.23 39.55 39.55 38.33 38.33 35.45 Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) V V V V V H H H H H 4874.00 4874.00 7311.00 7311.00 15450.00 4874.00 4874.00 7311.00 7311.00 15450.00 68.24 53.63 70.83 48.09 51.14 64.29 49.85 70.58 47.25 51.34 Pre-amplifi er
(dB) 38.89 38.89 38.78 38.78 35.89 38.89 38.89 38.78 38.78 36.68 802.11n(20MHz) Antenna Cable Loss Factor Emission Level Limits Margin
(dB)
(dB)
(dBuV/m)
(dBuV/m)
(dB) Low Channel:2412MHz Detector Type 7.85 7.85 7.52 7.52 6.75 7.85 7.85 7.52 7.52 6.75 25.66 25.66 24.55 24.55 26.59 25.66 25.66 23.55 23.22 27.88 62.15 49.08 63.84 41.31 47.87 57.48 44.57 63.36 39.93 51.99 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-11.85
-4.92
-10.16
-12.69
-26.13
-16.52
-9.43
-10.64
-14.07
-22.01 PK AV PK AV PK PK AV PK AV PK Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Middle Channel:2437MHz Limits
(dBuV/m) Margin Detector
(dB) Type 7.57 7.57 7.35 7.35 6.42 7.57 7.57 7.35 7.35 6.42 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 62.37 47.76 64.18 41.44 48.14 58.42 43.98 63.93 40.60 47.73 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00
-11.63
-6.24
-9.82
-12.56
-25.86
-15.58
-10.02
-10.07
-13.40
-26.27 PK AV PK AV PK PK AV PK AV PK Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) Pre-amplifi er
(dB) Cable Loss
(dB) Antenna Factor
(dB) Emission Level
(dBuV/m) Limits
(dBuV/m) Margin Detector
(dB) Type High Channel: 2462MHz 7.46 7.46 7.22 7.22 6.35 7.46 7.46 7.22 7.22 6.32 25.45 25.45 24.78 24.78 26.47 25.45 25.45 24.78 24.78 26.65 38.75 38.75 38.65 38.65 35.58 38.75 38.75 38.65 38.65 36.42 63.58 46.82 64.76 40.48 47.91 59.77 43.16 63.14 39.53 47.88 69.42 52.66 71.41 47.13 50.67 65.61 49.00 69.79 46.18 51.33 4924.00 4924.00 7386.00 7386.00 15450.00 4924.00 4924.00 7386.00 7386.00 15450.00 V V V V V H H H H H Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. All the ANT have test, only the worst case reported. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 25 of 59
-10.42
-7.18
-9.24
-13.52
-26.09
-14.23
-10.84
-10.86
-14.47
-26.12 74.00 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 PK AV PK AV PK PK AV PK AV PK Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.3 RADIATED BAND EMISSION MEASUREMENT 3.3.1 TEST REQUIREMENT:
FCC Part15 C Section 15.209 and 15.205 LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz) Class B (dBuV/m) (at 3M) PEAK 74 AVERAGE 54
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m). FREQUENCY (MHz) Above 1000 Notes:
Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (emission in restricted band) Setting Auto 2300MHz 2520 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average 3.3.2 TEST PROCEDURE Above 1GHz test procedure as below:
a. 1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. g. Test the EUT in the lowest channel,the Highest channel Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 26 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.3.3 DEVIATION FROM TEST STANDARD No deviation 3.3.4 TEST SETUP Radiated Emission Test-Up Frequency Above 1GHz 3.3.5 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 2.3 Unless otherwise a special operating condition is specified in the follows during the testing. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 27 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 3.3.6 TEST RESULT Polar
(H/V) Frequency
(MHz) Meter Reading
(dBuV) Pre-
amplifier
(dB) Cable Loss
(dB) Antenna Factor
(dB/m) 802.11b 802.11g 802.11n20 H H V V H H V V H H V V H H V V H H V V H H V V 2390.00 2400.00 2390.00 2400.00 2483.50 2485.50 2483.50 2485.50 2390.00 2400.00 2390.00 2400.00 2483.50 2485.50 2483.50 2485.50 2390.00 2400.00 2390.00 2400.00 2483.50 2485.50 2483.50 2485.50 60.86 54.50 62.35 55.53 62.15 55.54 60.00 52.56 62.43 54.54 59.27 53.65 60.54 53.48 62.06 54.41 62.90 54.32 62.54 55.51 60.97 53.35 59.75 52.57 38.06 38.06 38.06 38.06 38.17 38.17 38.2 38.2 38.06 38.06 38.06 38.06 38.17 38.17 38.2 38.2 38.06 38.06 38.06 38.06 38.17 38.17 38.2 38.2 Low Channel 2412MHz High Channel 2462MHz Low Channel 2412MHz High Channel 2462MHz Low Channel 2412MHz High Channel 2462MHz 20.15 20.15 20.15 20.15 20.54 20.54 20.54 20.54 20.15 20.15 20.15 20.15 20.54 20.54 20.54 20.54 20.15 20.15 20.15 20.15 20.54 20.54 20.54 20.54 7.42 7.42 7.42 7.42 7.45 7.45 7.45 7.45 7.42 7.42 7.42 7.42 7.45 7.45 7.45 7.45 7.42 7.42 7.42 7.42 7.45 7.45 7.45 7.45 Emission evel
(dBuV/m) Limits
(dBuV/m) Result PK PK AV 50.37 44.01 51.86 45.04 51.97 45.36 49.79 42.35 51.94 44.05 48.78 43.16 50.36 43.30 51.85 44.20 52.41 43.83 52.05 45.02 50.79 43.17 49.54 42.36 74.00 54.00 PASS 74.00 54.00 PASS 74.00 54.00 PASS 74.00 54.00 PASS 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS 54.00 PASS Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If the PK measured levels comply with average limit, then the average level were deemed to comply with average limit.
* is stand for AV measured. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 28 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 4. POWER SPECTRAL DENSITY TEST 4.1 APPLIED PROCEDURES / LIMIT FCC Part15 (15.247) , Subpart C Section Test Item Limit 15.247 Power Spectral Density 8 dBm
(in any 3KHz) 4.1.1 TEST PROCEDURE Frequency Range
(MHz) Result 2400-2483.5 PASS 1. Set analyzer center frequency to DTS channel center frequency. 2. Set the span to 1.5 times the DTS bandwidth. 3. Set the RBW to: 3 kHz RBW 100 kHz. 4. Set the VBW 3 x RBW. 5. Detector = peak. 6. Sweep time = auto couple. 7. Trace mode = max hold. 8. Allow trace to fully stabilize. 9. Use the peak marker function to determine the maximum amplitude level within the RBW. 10. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. 4.1.2 DEVIATION FROM STANDARD No deviation. 4.1.3 TEST SETUP 4.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.1 Unless otherwise a special operating condition is specified in the follows during the testing. Note: Power Spectral Density(dBm)=Reading+Cable Loss Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 29 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 4.1.5 TEST RESULTS Temperature Pressure Test Mode 26 101kPa TX b Mode Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency 2412 MHz 2437 MHz 2462 MHz Power Spectral Density(dBm) Limit
(dBm) 8 8 8
-17.946
-17.799
-19.131 TX CH01 Result PASS PASS PASS Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 30 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH06 TX CH11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 31 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Temperature Pressure Test Mode 26 101kPa TX g Mode Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency 2412 MHz 2437 MHz 2462 MHz Power Spectral Density(dBm) Limit
(dBm)
-20.926
-20.699
-20.655 8 8 8 Result PASS PASS PASS TX CH01 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 32 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH06 TX CH11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 33 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Temperature Pressure Test Mode 26 101kPa TX n Mode(20M) Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency 2412 MHz 2437 MHz 2462 MHz Power Spectral Density(dBm) Limit
(dBm)
-23.083
-22.596
-22.606 8 8 8 Result PASS PASS PASS TX CH01 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 34 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH06 TX CH11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 35 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 5. BANDWIDTH TEST 5.1 APPLIED PROCEDURES / LIMIT FCC Part15 (15.247) , Subpart C Section Test Item Limit 15.247(a)(2) Bandwidth 5.1.1 TEST PROCEDURE
>= 500KHz
(6dB bandwidth) Frequency Range
(MHz) Result 2400-2483.5 PASS 1. Set RBW = 100 kHz. 2. Set the video bandwidth (VBW) 3 x RBW. 3. Detector = Peak. 4. Trace mode = max hold. 5. Sweep = auto couple. 6. Allow the trace to stabilize. 7. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. 5.1.2 DEVIATION FROM STANDARD No deviation. 5.1.3 TEST SETUP 5.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 36 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 5.1.5 TEST RESULTS Temperature Pressure Test Mode 26 101kPa TX b Mode Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency
(MHz) 6dB bandwidth
(MHz) 2412 2437 2462 10.07 10.08 10.05 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 37 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH 06 TX CH 11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 38 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Temperature Pressure Test Mode 26 101kPa TX g Mode Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency
(MHz) 6dB bandwidth
(MHz) 2412 2437 2462 16.39 16.42 16.42 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 39 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH 06 TX CH 11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 40 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Temperature Pressure Test Mode 26 101kPa TX n Mode(20M) Relative Humidity 54%
Test Voltage AC120V 60Hz Frequency
(MHz) 6dB bandwidth
(MHz) 2412 2437 2462 17.57 17.57 17.58 Limit
(kHz) 500 500 500 Result Pass Pass Pass TX CH 01 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 41 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E TX CH 06 TX CH 11 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 42 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 6. PEAK OUTPUT POWER TEST 6.1 APPLIED PROCEDURES/LIMIT FCC Part15 (15.247) , Subpart C Section Test Item Limit Frequency Range
(MHz) 15.247(b)(3) Peak Output Power 6.1.1 TEST PROCEDURE 1 watt or 30dBm 2400-2483.5 Result PASS a. The EUT was directly connected to the Power meter 6.1.2 DEVIATION FROM STANDARD No deviation. 6.1.3 TEST SETUP 6.1.4 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 43 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 6.1.5 TEST RESULTS Temperature Pressure 26 101kPa Relative Humidity 54%
Test Voltage AC120V 60Hz Maximum Conducted Output Power(PK)
(dBm) LIMIT dBm 9.35 9.65 9.27 8.16 8.87 8.73 8.02 7.76 7.78 30 30 30 30 30 30 30 30 30 Frequency
(MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 802.11b 802.11g 802.11n20 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 44 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 7. 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 7.1 APPLICABLE STANDARD in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in15.205(a), must also comply with the radiated emission limits specified in15.209(a). 7.2 TEST PROCEDURE Using the following spectrum analyzer setting:
a) Set the RBW = 100KHz. b) Set the VBW = 300KHz. c) Sweep time = auto couple. d) Detector function = peak. e) Trace mode = max hold. f) Allow trace to fully stabilize. 7.3 DEVIATION FROM STANDARD No deviation. 7.4 TEST SETUP 7.5 EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 Unless otherwise a special operating condition is specified in the follows during the testing. 7.6 TEST RESULT Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 45 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 802.11b: Band Edge, Left Side 802.11b: Band Edge, Right Side Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 46 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 802.11g: Band Edge, Left Side 802.11g: Band Edge, Right Side Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 47 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 802.11n-HT20: Band Edge, Left Side 802.11n-HT20: Band Edge, Right Side Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 48 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E CONDUCTED EMISSION MEASUREMENT 802.11b Low Channel 2412MHz Middle Channel 2437MHz High Channel 2462MHz Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 49 of 59 802.11g Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Low Channel 2412MHz Middle Channel 2437MHz High Channel 2462MHz Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 50 of 59 802.11n20 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Low Channel 2412MHz Middle Channel 2437MHz High Channel 2462MHz Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 51 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 8. DUTY CYCLE OF TEST SIGNAL 8.1 STANDARD REQUIREMENT Pre-analysis Check: While conducting average power measurement, duty cycle of each mode shall be checked to ensure its duty cycle in order to compensate for the loss due to insufficient ratio of duty cycle. All duty cycle is pre-scanned, and result as obtained below shows only the most representative ones where duty cycle is conducted as the given transmission with given virtual operation that expresses the percentage. 8.2 FORMULA:
Duty Cycle = Ton / (Ton+Toff) Measurement Procedure:
1. Set span = Zero 2. RBW = 8MHz 3. VBW = 8MHz, 4. Detector = Peak Duty Cycle:
Duty Cycle Duty Fator 802.11b 802.11g 802.11n(HT20) 1 1 1
(dB) 0 0 0 Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 52 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 802.11b 802.11g Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 53 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 802.11n(HT20) Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 54 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 9. ANTENNA REQUIREMENT 9.1 STANDARD REQUIREMENT 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. 9.2 EUT ANTENNA The EUT antenna is PCB antenna, It comply with the standard requirement. Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 55 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 10. EUT TEST PHOTO Conducted Measurement Photos Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 56 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E Radiated Measurement Photos Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 57 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E 11. EUT PHOTO Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 58 of 59 Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC-LH190700623E END OF REPORT Test Report Tel: 400-788-9558 Web: https://www.bctc-lab.com BCTC/RF-EMC-007 Ver.A.0 Page 59 of 59
1 | test setup photos | Test Setup Photos | 151.93 KiB | June 08 2019 |
Radiated Measurement Photos Conducted Measurement Photos
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-06 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-08-06
|
||||
1 | Applicant's complete, legal business name |
SHENZHEN ECARE ELECTRONICS CO., LTD
|
||||
1 | FCC Registration Number (FRN) |
0022903702
|
||||
1 | Physical Address |
5-6/F., Block B, Huali Industrial Building
|
||||
1 |
Shenzhen, Guang Dong, 518133
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AATP
|
||||
1 | Equipment Product Code |
TP90
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M****** Y********
|
||||
1 | Title |
Sales assistant
|
||||
1 | Telephone Number |
00867********
|
||||
1 | Fax Number |
00867********
|
||||
1 |
m******@ecareltd.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Alexa Enabled Thermometer and Hygrometer | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. Device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen BCTC Testing Co., Ltd.
|
||||
1 | Name |
A**** M********
|
||||
1 | Telephone Number |
+8675********
|
||||
1 |
a******@bctc-lab.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.0092260 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC