all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 193.30 KiB | July 08 2019 | |||
1 |
|
Internal Photos | Internal Photos | 424.82 KiB | July 08 2019 | |||
1 |
|
External Photos | External Photos | 517.09 KiB | July 08 2019 | |||
1 |
|
Label and Label Location | ID Label/Location Info | 77.60 KiB | July 08 2019 | |||
1 |
|
Agent Authorization Rev | Cover Letter(s) | 21.47 KiB | July 08 2019 | |||
1 |
|
FCC Short & Long Term Confidentiality | Cover Letter(s) | 68.34 KiB | July 08 2019 | |||
1 |
|
LCS190611036AEA FCC Test Report | Test Report | 1.01 MiB | July 08 2019 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 271.43 KiB | July 08 2019 |
1 | User Manual | Users Manual | 193.30 KiB | July 08 2019 |
VB602-T Circuit Description This product VB602-T is a baby unit TRANSCEIVER. When plugging in the POWER SUPPLY, all the circuit will start to work. The main chip MSF9200 will run the code by 26MHZ OSC, then it turns on the necessary circuit. Include the RF circuit, speaker and CAMERA. In this time, the processor works first to build up a communication chain for another parent unit TRANSCEIVER. When the wireless chain setup successfully, The processor encodes the moving picture and voice data stream, and send them to parent unit TRANSCEIVER by the RF circuit. Also, VB602-T can play music by driving the speaker. FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
1 | Internal Photos | Internal Photos | 424.82 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Internal Photos of the EUT Fig.1 Fig.2 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Fig.3 Fig.4 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T 2.4G antenna Fig.5 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3
1 | External Photos | External Photos | 517.09 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T External Photos of the EUT Fig.1 Fig.2 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Fig.3 Fig.4 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Fig.5 Fig.6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Fig.7 Fig.8 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4
1 | Label and Label Location | ID Label/Location Info | 77.60 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T LABEL AND LOCATION Digital Video Baby Monitor Model No.: VB602-T FCC ID: 2AFX2VB602-T Input: 5V/1A This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Made in China Size: L3.0cm*W2.0cm Label Location This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1
1 | Agent Authorization Rev | Cover Letter(s) | 21.47 KiB | July 08 2019 |
Shenzhen Feelstorm Technology Co., Ltd Agent Authorization Company: Shenzhen Feelstorm Technology Co., Ltd Address: 5F Block C,HuaWan industrial Park,No.119,BaoAn DaDao,BaoAn District,ShenZhen CHINA Product Name: Digital Video Baby Monitor Trade Mark: N/A Model Number(s): VB602-T FCC ID: 2AFX2VB602-T We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Date: 2019-07-29 Name:
Felix Liu Title:
Manager Company: Shenzhen Feelstorm Technology Co., Ltd
1 | FCC Short & Long Term Confidentiality | Cover Letter(s) | 68.34 KiB | July 08 2019 |
Shenzhen Feelstorm Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2019-07-29 Subject; Request for Confidentiality FCC ID: 2AFX2VB602-T To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: Felix Liu Title: Manager
1 | LCS190611036AEA FCC Test Report | Test Report | 1.01 MiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA FCC TEST REPORT FOR Shenzhen Feelstorm Technology Co.,Ltd Digital Video Baby Monitor Test Model: VB602-T
: Shenzhen Feelstorm Technology Co.,Ltd
:
5F Block C,HuaWan industrial Park,No.119,Baoan DaDao,BaoAn District,ShenZhen CHINA
: Shenzhen LCS Compliance Testing Laboratory Ltd
:
1/F., Xingyuan Industrial Park, Tongda Road, Baoan Avenue, Baoan District, Shenzhen, Guangdong, China
(+86)755-82591330
:
:
(+86)755-82591332
: www.LCS-cert.com
: webmaster@LCS-cert.com
: June 11, 2019
: 1
: Prototype
: June 11, 2019 ~ June 28, 2019
: July 01, 2019 Prepared for Address Prepared by Address Tel Fax Web Mail Date of receipt of test sample Number of tested samples Sample number Date of Test Date of Report This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA FCC TEST REPORT FCC CFR 47 PART 15 C (15.249) Report Reference No. ................. : LCS190611036AEA Date of Issue................................... : July 01, 2019 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... :
1/F., Xingyuan Industrial Park, Tongda Road, Baoan Avenue, Baoan District, Shenzhen, Guangdong, China Testing Location/ Procedure ..........
:
Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Applicants Name ......................... : Shenzhen Feelstorm Technology Co.,Ltd Address ........................................... :
5F Block C,HuaWan industrial Park,No.119,Baoan DaDao,BaoAn District,ShenZhen CHINA Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013 Test Report Form No. .................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ................. : Digital Video Baby Monitor Trade Mark ..................................... : N/A Test Model ...................................... : VB602-T Ratings ............................................ : 5V DC,1000mAh by adapter Result ........................................... : Positive Compiled by:
Supervised by:
Approved by:
Jayden Zhuo / Administrators Aking Jin / Technique principal Gavin Liang/ Manager This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA FCC -- TEST REPORT Test Report No. :
LCS190611036AEA July 01, 2019 Date of issue Test Model..............................
: VB602-T EUT.........................................
: Digital Video Baby Monitor Applicant...............................
: Shenzhen Feelstorm Technology Co.,Ltd Address..................................
:
5F Block C,HuaWan industrial Park,No.119,Baoan DaDao,BaoAn District,ShenZhen CHINA Telephone...............................
: /
Fax..........................................
: /
Manufacturer........................
: Shenzhen Feelstorm Technology Co.,Ltd Address................................... :
5F Block C,HuaWan industrial Park,No.119,Baoan DaDao,BaoAn District,ShenZhen CHINA Telephone...............................
: /
Fax..........................................
: /
Factory...................................
: Shenzhen Feelstorm Technology Co.,Ltd Address................................... :
5F Block C,HuaWan industrial Park,No.119,Baoan DaDao,BaoAn District,ShenZhen CHINA Telephone...............................
: /
Fax..........................................
: /
Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Revision History Revision 000 Issue Date July 01, 2019 Revisions Initial Issue Revised By Gavin Liang This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA TABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................... 6 1.1 Description of Device (EUT) ............................................................................................................ 6 1.2. Support Equipment List ................................................................................................................... 6 1.3. External I/O ....................................................................................................................................... 6 1.4. Description of Test Facility ............................................................................................................. 6 1.5. Statement of the measurement uncertainty ................................................................................. 6 1.6. Measurement Uncertainty ............................................................................................................... 7 1.7. Description of Test Modes .............................................................................................................. 7 2. TEST METHODOLOGY ............................................................................................................ 8 2.1. EUT Configuration ........................................................................................................................... 8 2.2. EUT Exercise .................................................................................................................................... 8 2.3. General Test Procedures ................................................................................................................ 8 3. CONNECTION DIAGRAM OF TEST SYSTEM ..................................................................... 9 3.1. Justification ....................................................................................................................................... 9 3.2. EUT Exercise Software ................................................................................................................... 9 3.3. Special Accessories ......................................................................................................................... 9 3.4. Block Diagram/Schematics ............................................................................................................ 9 3.5. Equipment Modifications ................................................................................................................. 9 3.6. Test Setup ......................................................................................................................................... 9 4. SUMMARY OF TEST RESULTS ........................................................................................... 10 5. ANTENNA REQUIREMENT ................................................................................................... 11 6. POWER LINE CONDUCTED EMISSIONS (NOT APPLICABLE) ................................... 12 7. RADIATED EMISSION MEASUREMENT ............................................................................ 14 8. RESULTS FOR BAND EDGE TESTING ............................................................................. 23 9. 99% OCCUPIED BANDWIDTH AND 20 DB BANDWIDTH MEASUREMENT ............. 29 10. LIST OF MEASURING EQUIPMENT ................................................................................. 31 11. TEST SETUP PHOTOGRAPHS OF THE EUT ................................................................. 32 12. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................... 32 13. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................... 32 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 1. GENERAL INFORMATION 1.1 Description of Device (EUT) EUT Test Model Transmit:
: Digital Video Baby Monitor
: VB602-T Frequency Range
: 2415-2460MHz
(2415, 2418, 2421, 2424, 2427, 2430, 2433, 2436, 2439, 2442, 2445, 2448, 2451, 2454, 2457, 2460) (Unit: MHz) Channel Number
: 16 Modulation Type Antenna Description Power Supply Hardware Version Software Version
: GFSK
: Dipole Antenna 2.00dBi (Max.)
: 5V DC,1000mAh by adapter
: V1.0
: V1.0 1.2. Support Equipment List Manufacturer Description Model Serial Number Certificate E-TEK Electronics Manufactory Ltd. 1.3. External I/O Adapter ZD5C050100USW
--
SDOC I/O Port Description Mirco USB Port Quantity 1 Cable N/A 1.4. Description of Test Facility FCC Registration Number is 254912. Industry Canada Registration Number is 9642A-1. EMSD Registration Number is ARCB0108. UL Registration Number is 100571-492. TUV SUD Registration Number is SCN1081. TUV RH Registration Number is UA 50296516-001. NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier: CN0071. The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz. 1.5. Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 6 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 Specification for radio disturbance and immunity measuring apparatus and methods Part 4:
Uncertainty in EMC Measurements and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 1.6. Measurement Uncertainty Test Item Frequency Range Uncertainty Radiation Uncertainty
:
200MHz~1000MHz 9KHz~30MHz 30MHz~200MHz Conduction Uncertainty Power disturbance
:
:
1GHz~26.5GHz 26.5GHz~40GHz 150kHz~30MHz 30MHz~300MHz 3.10dB 2.96dB 3.10dB 3.80dB 3.90dB 1.63dB 1.60dB Note
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2. 1.7. Description of Test Modes Operates in the unlicensed ISM Band at 2.4GHz. With basic data rate feature, the data rates can be up to 1 Mb/s by modulating the RF carrier using GFSK techniques. The EUT works in the X-axis, Y-axis, Z-axis. The following operating modes were applied for the related test items. All test modes were tested, only the result of the worst case was recorded in the report. Mode of Operations GFSK Frequency Range
(MHz) 2415 2436 2460 Data Rate
(Mbps)
/
/
/
For Conducted Emission For Radiated Emission Test Mode Test Mode TX Mode TX Mode Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel with the highest output power, that was determined to be TX. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 7 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 2. TEST METHODOLOGY All measurements contained in this report were conducted with ANSI C63.10: 2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd. 2.1. EUT Configuration The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 2.2. EUT Exercise The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209 and 15.249 under the FCC Rules Part 15 Subpart C. 2.3. General Test Procedures 2.3.1 Conducted Emissions The EUT is directly placed on the ground. According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes. 2.3.2 Radiated Emissions The EUT is placed on a turntable, which is directly placed on the ground. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 8 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 3. CONNECTION DIAGRAM OF TEST SYSTEM 3.1. Justification The system was configured for testing in a continuous transmit condition. Continuous transmitting was pre-programmed. Itll keep transmitting with modulated signal at the lowest channel by installing the batter. When press the "up" button, it'll move to the next channel. Repeat press "up" button, it'll transmitting at each of the channel used. 3.2. EUT Exercise Software Press the PageUp button, and change the channel. 3.3. Special Accessories N/A 3.4. Block Diagram/Schematics Please refer to the related document 3.5. Equipment Modifications Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT. 3.6. Test Setup Please refer to the test setup photo. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 9 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 4. SUMMARY OF TEST RESULTS Applied Standard: FCC Part 15 Subpart C 15.249 FCC Rules 15.203 15.207(a) Description Of Test Antenna Requirement Result Compliant Power Line Conducted Emissions Compliant 15.205(a), 15.209(a), 15.249(a), 15.249(c) Radiated Emissions Measurement Compliant 15.249 (d) 15.215(c) Band Edges Measurement Compliant 99% and 20 dB Bandwidth Compliant This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 10 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 5. ANTENNA REQUIREMENT 5.1. Standard Applicable According to 15.203 and RSS-Gen, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. 5.2. Antenna Connected Construction The EUT use Dipole Antenna and maximum antenna gain is 2.00dBi, antenna cannot replacement, meets FCC Part 15.203 antenna requirement. Please see EUT photo for details. 5.3. Results Compliance This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 11 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 6. POWER LINE CONDUCTED EMISSIONS 6.1. Standard Applicable According to 15.207 (a) & RSS-Gen 8.8: For an intentional radiator which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range are listed as follows:
Frequency Range Limits (dBV)
(MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50
* Decreasing linearly with the logarithm of the frequency 6.2. Block Diagram of Test Setup 6.3. Test Results The test data please refer to following page. Temperature Test Engineer 23.3 Li Huan Humidity 53.4%
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 12 of 32 EUT LISN EMI receiver Reference ground plane Vert. reference plane SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA AC Power Line Conducted Emission (Power input to adapter @ AC 120V/60Hz (Worst Case)) Line Neutral
***Note: Pre-scan all modes and recorded the worst case results in this report. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 13 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 7. RADIATED EMISSION MEASUREMENT 7.1. Standard Applicable According to FCC 15.249: Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in 15.209, whichever is the lesser attenuation. 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) and 15.249 limit in the table below has to be followed. Fundamental Frequency 902-928MHz 2400-2483.5MHz 5725-5875MHz 24.0-24.25GHz Frequencies
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength of fundamental Field Strength of harmonics
(millivolts/meter)
(microvolts/meter) 50 50 50 250 Field Strength
(microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 500 500 500 2500 Measurement Distance
(meters) 300 30 30 3 3 3 3 According to RSS-210 B.10:
The field strength of fundamental and harmonic emissions, measured at 3 m, shall not exceed 50 mV/m and 0.5 mV/m respectively. The field strength limits shall be measured using an average detector, except for the fundamental emission in the frequency band 902-928 MHz, which is based on measurements using an International Special Committee on Radio Interference (CISPR) quasi-peak detector. Emissions radiated outside of the specified frequency bands, except for harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the general field strength limits listed in RSS-Gen, whichever is less stringent. 7.2. Instruments Setting Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver. Spectrum Parameter Setting Attenuation Auto Start Frequency 1000 MHz 10th carrier harmonic Stop Frequency RB / VB (Emission in restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average RB / VB (Emission in non-restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 14 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency 7.3. Test Procedure Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP 1) Sequence of testing 9 kHz to 30 MHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna height is 0.8 meter.
--- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement:
--- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0 to 360) and by rotating the elevation axes (0 to 360).
--- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 15 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 2) Sequence of testing 30 MHz to 1 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height changes from 1 to 3 meter.
--- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter.
--- The final measurement will be done with QP detector with an EMI receiver.
--- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 16 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 3) Sequence of testing 1 GHz to 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height scan range is 1 meter to 2.5 meter.
--- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 17 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 4) Sequence of testing above 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 1 meter.
--- The EUT was set into operation. Premeasurement:
--- The antenna is moved spherical over the EUT in different polarizations of the antenna. Final measurement:
--- The final measurement will be performed at the position and antenna orientation for all detected emissions that were found during the premeasurements with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 18 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 7.4. Block Diagram of Test Setup Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade form 3m to 1m. Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1.5m]) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB]. 7.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 19 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 7.6. Test Results of Radiated Emissions (9 KHz~30 MHz) Temperature Test Engineer 23.9 Li Huan Humidity Configurations 54.1 %
2415MHz Freq.
(MHz)
-
Level
(dBuV)
-
Over Limit
(dB)
-
Over Limit
(dBuV) Remark
-
See Note Note:
The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported. Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor. 7.7. Test Results of Radiated Emissions (30 MHz 1000 MHz) Temperature Test Engineer 23.9 Li Huan Humidity Configurations 54.1%
2415MHz Vertical This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 20 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Horizontal Note:
1). Pre-scan all modes and recorded the worst case results in this report (GFSK (Low Channel)). 2). Emission level (dBuV/m) = 20 log Emission level (uV/m). 3). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 21 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 7.8. Results for Radiated Emissions (1 26 GHz) Field Strength of Fundamental (TX-2415 MHz) Measure Result
(PK, dBuV/m) Measure Result
(AVG, dBuV/m) Peak Limit
(dBuV/m) AVG Limit
(dBuV/m) 84.34 83.42 114 114 94 94 Result Pass Pass Frequency
(MHz) 2415.00 2415.00 Pol. H V Reading Freq. MHz Level dBuV 4830.00 51.96 4830.00 38.07 4830.00 52.71 4830.00 39.53 Ant. Fac. dB/m 33.06 33.06 33.06 33.06 95.76 90.18 Pre. Fac. dB 35.04 35.04 35.04 35.04 Cab. Loss dB 3.94 3.94 3.94 3.94 Frequency
(MHz) 2436.00 2436.00 Pol. H V Freq. MHz 4872.00 4872.00 4872.00 4872.00 Reading Level dBuV 50.90 40.14 49.85 40.11 Ant. Fac. dB/m 33.16 33.16 33.16 33.16 Frequency
(MHz) 2460.00 2460.00 Pol. H V Reading Level dBuV 51.21 39.65 50.24 39.02 Ant. Fac. dB/m 33.26 33.26 33.26 33.26 Freq. MHz 4920.00 4920.00 4920.00 4920.00 Notes:
87.59 88.28 Pre. Fac. dB 35.15 35.15 35.15 35.15 Cab. Loss dB 3.96 3.96 3.96 3.96 96.05 94.28 Pre. Fac. dB 35.14 35.14 35.14 35.14 Cab. Loss dB 3.98 3.98 3.98 3.98 Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 53.92 40.03 54.67 41.49 74.00 54.00 74.00 54.00
-20.08
-13.97
-19.33
-12.51 Peak Horizontal Average Horizontal Peak Average Vertical Vertical Field Strength of Fundamental (TX-2436 MHz) Measure Result
(PK, dBuV/m) Measure Result
(AVG, dBuV/m) Peak Limit
(dBuV/m) AVG Limit
(dBuV/m) 80.04 82.18 114 114 94 94 Result Pass Pass Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 52.87 42.11 51.82 42.08 74.00 54.00 74.00 54.00
-21.13
-11.89
-22.18
-11.92 Peak Horizontal Average Horizontal Peak Average Vertical Vertical Field Strength of Fundamental (TX-2460 MHz) Measure Result
(PK, dBuV/m) Measure Result
(AVG, dBuV/m) Peak Limit
(dBuV/m) AVG Limit
(dBuV/m) 81.08 82.23 114 114 94 94 Result Pass Pass Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 53.31 41.75 52.34 41.12 74.00 54.00 74.00 54.00
-20.69
-12.25
-21.66
-12.88 Peak Horizontal Average Horizontal Peak Average Vertical Vertical 1). Measuring frequencies from 9 KHz - 10th harmonic (ex. 26GHz), No emission found between lowest internal used/generated frequency to 30 MHz. 2). Radiated emissions measured in frequency range from 9 KHz - 10th harmonic (ex. 26GHz) were made with an instrument using Peak detector mode. 3). 18~25 GHz at least have 20dB margin. No recording in the test report. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 22 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 8. RESULTS FOR BAND EDGE TESTING 8.1. Standard Applicable According to FCC 15.249 (d): Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in 15.209, whichever is the lesser attenuation. According to RSS-210 B.10 (b): Emissions radiated outside of the specified frequency bands, except for harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the general field strength limits listed in RSS-Gen, whichever is less stringent. 8.2. Test Setup Layout 8.3. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer. 8.4. Test Procedures 3) Sequence of testing 1 GHz to 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 23 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height scan range is 1 meter to 2.5 meter.
--- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. 8.5. Measuring Instruments and Setting Temperature Test Engineer 23.9 Li Huan Humidity 54.3%
PASS Remark:
1. The other emission levels were very low against the limit. 2. The average measurement was not performed when the peak measured data under the limit of average detection. 3. Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep time=Auto/Detector=Peak;
4. Please refer to following test plots;
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 24 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Channel 0 / 2415 MHz Horizontal This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 25 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Channel 0 / 2415 MHz Vertical This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 26 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Channel 15 / 2460 MHz Horizontal This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 27 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Channel 15 / 2460 MHz Vertical This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 28 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 9. 99% OCCUPIED BANDWIDTH AND 20 DB BANDWIDTH MEASUREMENT 9.1. Standard Applicable According to 15.215c and RSS-Gen section 6.7 The occupied bandwidth or the 99% emission bandwidth is defined as the frequency range between two points, one above and the other below the carrier frequency, within which 99% of the total transmitted power of the fundamental transmitted emission is contained. The occupied bandwidth shall be reported for all equipment in addition to the specified bandwidth required in the applicable RSSs. In some cases, the x dB bandwidth is required, which is defined as the frequency range between two points, one at the lowest frequency below and one at the highest frequency above the carrier frequency, at which the maximum power level of the transmitted emission is attenuated x dB below the maximum in band power level of the modulated signal, where the two points are on the outskirts of the in-band emission. 9.2. Block Diagram of Test Setup 9.3. Test Procedure Use the following spectrum analyzer settings:
Span = 3MHz RBW = 30 KHz VBW = 100 KHz Sweep = auto Detector function = peak Trace = max hold The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to the other side of the emission, until it is (as close as possible to) even with the reference marker level. The marker-delta reading at this point is the 20 dB bandwidth of the emission. If this value varies with different modes of operation (e.g., data rate, modulation format, etc.), repeat this test for each variation. The limit is specified in one of the subparagraphs of this Section. Submit this plot(s). 9.4. Test Results Temperature Test Engineer 24.5 Li Huan Humidity 54.3%
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 29 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA Test Result of 99% and 20dB Bandwidth Measurement Test Frequency 20dB Bandwidth 99% Bandwidth
(MHz) 2415 2436 2460
(MHz) 2.085 2.100 2.066
(MHz) 2.0449 2.0414 2.0265 Limit
(MHz) Non-Specified Non-Specified Non-Specified Remark:
1. Test results including cable loss;
2. Please refer following test plots;
20dB Bandwidth and 99% Bandwidth GFSK GFSK 2415 MHz 2460 MHz 2436 MHz This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 30 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 10. LIST OF MEASURING EQUIPMENT Item Equipment Manufacturer Model No. Serial No. Cal Date Due Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 MXA Signal Analyzer DC Power Supply Temperature & Humidity Chamber EMI Test Software 3m Semi Anechoic Chamber Positioning Controller Active Loop Antenna By-log Antenna Horn Antenna Broadband Horn Antenna Broadband Preamplifier Agilent Agilent GUANGZHOU GOGNWEN AUDIX SIDT FRANKONIA MF N9020A E3642A MY49100060 2018-11-15 2019-11-14 N/A 2018-11-15 2019-11-14 GDS-100 70932 2018-10-10 2019-10-09 E3
/
N/A N/A SAC-3M 03CH03-HY 2019-06-12 2020-06-11 MF-7082
/
2019-06-12 2020-06-11 SCHWARZBECK FMZB 1519B 00005 2018-07-26 2019-07-25 SCHWARZBECK VULB9163 9163-470 2018-07-26 2019-07-25 SCHWARZBECK BBHA 9120D 9120D-1925 2018-07-02 2019-07-01 SCHWARZBECK BBHA 9170 791 2018-09-20 2019-09-19 SCHWARZBECK BBV 9719 9719-025 2018-09-20 2019-09-19 EMI Test Receiver RS SPECTRUM ANALYZER R&S R&S Broadband Preamplifier
/
RF Cable-R03m RF Cable-HIGH EMI Test Receiver Artificial Mains 10dB Attenuator Jye Bao SUHNER R&S R&S ESR 7 FSP40 101181 100503 2019-06-12 2020-06-11 2018-11-15 2019-11-14 BP-01M18G P190501 2019-07-01 2020-06-30 RG142 CB021 2019-06-12 2020-06-11 SUCOFLEX 106 ESPI ENV216 03CH03-HY 2019-06-12 2020-06-11 101840 101288 261115-001-0 032 2019-06-11 2020-06-10 2019-06-12 2020-06-11 2019-06-11 2020-06-10 SCHWARZBECK MTS-IMP-13 6 Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 31 of 32 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T Report No.: LCS190611036AEA 11. TEST SETUP PHOTOGRAPHS OF THE EUT Please refer to separated files for Test Setup Photos of the EUT. 12. EXTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for External Photos of the EUT. 13. INTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for Internal Photos of the EUT.
------------THE END OF REPORT----------
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 32 of 32
1 | Test Setup Photos | Test Setup Photos | 271.43 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2 _______________________________________________________________________________________________ SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AFX2VB602-T 1.2. Photo of Conducted Emissions Measurement Fig. 3 _______________________________________________________________________________________________
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-07 | 2415 ~ 2460 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-08-07
|
||||
1 | Applicant's complete, legal business name |
Shenzhen Feelstorm Technology Co.,Ltd
|
||||
1 | FCC Registration Number (FRN) |
0024890196
|
||||
1 | Physical Address |
5F, Block C, HUAWAN Industrial PARK
|
||||
1 |
Shenzhen
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AFX2
|
||||
1 | Equipment Product Code |
VB602-T
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
F******** l******
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+86(0********
|
||||
1 | Fax Number |
+86(0********
|
||||
1 |
F******@feelstorm.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Shenzhen Feelstorm Technology Co., Ltd
|
||||
1 | Physical Address |
China
|
||||
1 |
F******@feelstorm.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Digital Video Baby Monitor | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen LCS Compliance Testing Laboratory Ltd.
|
||||
1 | Name |
G**** L********
|
||||
1 | Telephone Number |
0755-********
|
||||
1 | Fax Number |
0755-********
|
||||
1 |
g******@lcs-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2415.00000000 | 2460.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC