Introduction FS-R7P ANT 7 PWM PPM/i-BUS/S.BUS Overview
[10]
[9]
[8]
[17]
[16]
[11]
[2]-[5]
[7]
[6]
[1]
[12]
[13] [14]
[16]
[17]
[15] [16]
[17]
FS-R7P based on ANT protocol is a receiver which provides seven channels. It has an external single antenna, can output PWM or PPM/i-BUS/S.BUS signal. It has a compact design. It can be adapted to a variety of model cars or boats.
[1] CH1/P
[2]-[5]CH2- CH5
[6]
[7] BVD/VCC( / )
[8] CH7
[9]SERVO
[10]LED
[11]
[12]
[13]
[14] CH6
[15]
[16] + (
[17] - (
[18] BVD
[19]
[20]
[1] CH1/P(PWM/PPM)
[2]-[5]CH2- CH5
[6] BIND interface
[7] BVD/VCC(Battery voltage detection/Power supply interface)
[8] CH7
[9] SERVO
[10] LED
[11] Antenna
[12] BIND button
[13] SENS interface
[14] CH6
[15] Signal pin
[16] + (Power anode)
[17] - (Power cathode)
[18] BVD harness
[19] Connect to battery anode
[20] Connect to battery cathode BVD 0~70V Note: BVD voltage detection range: 0~70V
[18]
[19]
[20]
Specifications FS-R7P FS-G7P ANT ) 7 2.4GHz ISM
<20dBm 300 ANT 1024 PWM/PPM/i-BUS/S.BUS 3.5 ~ 9V/DC
-10 ~ +60 20% ~ 95 PPX4 35.0mm*23.3mm*13.3mm 8.0g CEFCC ID: 2A2UNR7P00 Interface Introduction CH1~CH7 PWM CH1 PPM BVD/VCCBVD BVD
, BIND SENS i-BUS SERVO i-BUS/S.BUS i-BUS Product Name: FS-R7P Adaptive transmitter: FS-G7P( Adapts transmitters with ANT protocol) Adaptive Models: Cars or boats Numbers of Channels: 7 RF: 2.4GHz ISM Maximum Power: <20dBm (e.i.r.p.) EU Antenna: Single antenna Distance: 300m (ground) 2.4G Protocol: ANT Resolution: 1024 Data Output: PWM/PPM/i-BUS/S.BUS Input Power: 3.5 ~ 9V/DC Online Update: Yes Temperature Range: -10 ~ +60 Humidity Limit: 20% ~ 95%
WaterProof: PPX4 Dimensions: 35.0mm*23.3mm*13.3mm Weight: 8.0g Certification: CE, FCC ID: 2A2UNR7P00 CH1~CH7: To output PWM signal (Additional, CH1 can output PPM signal). Can be connected to the servos, or other compatiable components. BVD/VCC: During the battery voltage detecting process, a BVD harness is connected here. During normal operation, the power is applied to this interface. BIND interface: During the binding process, a bind cable is connected to this interface. SENS interface: For connecting i-BUS sensors. SERVO interface: To output i-BUS or S.BUS signal, and support channel expansion in i-BUS type. Binding
, 1. 2. LED Bind LED 3 3. LED 4. FS-R7P Receiverhttp://www.flysky-cn.comCopyright 2021 Flysky Technology co., ltd Binding 1. 2. 3. LED LED 4. LED The receiver supports two -way binding and one-way binding. The transmitter will display the information returned from the receiver after the two-way binding is completed. Follow the steps below to bind in two-way binding:
1. Select [ANT 2 WAY] for RF standard of the transmitter, then put the transmitter in bind mode. 2. The receiver supports three ways to enter bind mode: BIND button binding, bind cable binding and BIND button binding after power-on. BIND button binding: Press and hold the BIND button of the receiver while powering on the receiver, tthe LED of the receiver should be flashing, indicating that the receiver is in bind mode. Then release the BIND button. Bind cable binding: Insert the bind cable to the BIND interface of the receiver, then power on the receiver. The LED of the receiver should be flashing, indicating that the receiver is in bind mode. Note that you need to remove the bind cable from the receiver after the binding process is completed. BIND button binding after power-on: The receiver has not been connected to the transmitter when it is powered on. Press and hold the BIND button for 3 seconds, the LED of the receiver should be flashing, indicating that the receiver is in bind mode. Then release the BIND button. 3. When the LED of the receiver is solid on, the binding process should be completed. The transmitter exits the bind mode 4. Check to make sure the transmitter and receiver functions are working correctly, repeat steps 1 to 3 (binding process) if any Follow the steps below to bind in one-way binding:
1. Select [ANT 1 WAY] for RF standard of the transmitter, then put the transmitter in bind mode. 2. Put the receiver in bind mode ( Refer to the description above for entering bind mode). 3. When the LED of the receiver is in slow flashing state, the binding process should be completed. You need to manually put the transmitter to exit the bind mode. Then the LED of the receiver is solid on, indicating that the binding is completed. 4. Check to make sure the transmitter and receiver functions are working correctly, repeat steps 1 to 3 (binding process) if any Note: Put the transmitter in bind mode first, then put the receiver in bind mode. If the binding is not completed within ten seconds, the LED of the receiver will enter its slow flashing state. Firmware update FlySkyAssistant 3.0 www.flysky-
cn.com 1. LED 2. LED automaticlly. problems arise. problems arise. LED LED CH4 CH6 The firmware of this receiver is updated through the FlyskyAssistant (Only version 3.0 or above is supported. The firmware of FlyskyAssistant is available on the Flysky official website). This receiver can be updated via the following two ways:
1. After the binding between the transmitter and the receiver (the LED of the receiver is solid on), connect the transmitter to the computer, then open the FlyskyAssistant on the computer to update the firmware. 2. Connect the transmitter to the computer. Then put the receiver to enter the forced update mode by referring to the following three ways (The LED of the receiver operates in three-flash-one-off manner repeatedly). Afterwards, open the FlyskyAssistant on the computer to update the firmware. Power on the receiver while pressing and holding the BIND button for more than ten seconds, until the LED of the receiver operates in three-
flash-one-off manner repeatedly, then release the BIND button. Power on the receiver first, then press and hold the BIND button for more than ten seconds, when the LED of the receiveroperates in three-
flash-one-off manner repeatedly, then release the BIND button. Connect the bind cable to the signnal pins of the CH4 and CH6, then power on the receiver. FS-R7P Receiverhttp://www.flysky-cn.comCopyright 2021 Flysky Technology co., ltd Failsafe
[ ] PWM ;
1. PPM/i-BUS/S.BUS [ ] [ ]
2. S.BUS 3. PPM/i-BUS [ ] [ ]
The failsafe function is used to output the channel value according to the out-of-control protection value set by the user after the receiver loses its signal and is out of control to protect the model and personnel. It can also be set failsafe for each channel respectively. This receiver supports two failsafe modes: [ON]and [OFF]
[OFF] It is no output for the interface of PWM.
[ON] Outputs the failsafe values set for each channel. Notes:
1. For bus signal types such as PPM/i-BUS/S.BUS, a single or several of these channels are not allowed to be in [No output] mode. The actual signal is held at the last output value when the channel is set to [No output] mode. 2. Because the S.BUS signal information contains failsafe flag bits, the failsafe settings of each channel are communicated to subsequent devices by the failsafe flag bits. If the connected devices support the failsafe flag bit analysis, the failsafe values set for each channel are output after out of control. 3. For the signal PPM/i-BUS without failsafe flag bits, it supports the setting of the signal to [No output] mode in case of out of control. After setting to [No output] mode, regardless of the setting of the failsafe of each channel, each channel will be in [No output] mode after out of control. 1 Attentions:
noise. Make sure the product is installed and calibrated correctly, failure to do so may result in serious injury. Make sure the receiver's battery is disconnected before turning off the transmitter, failure to do so can result out of control. Unreasonable setting of the Failsafe may cause accidents. Make sure the receiver is mounted away from motors, electronic speed controllers or any device that emits excessive electrical Keep the receiver's antenna at least 1cm away from conductive materials such as carbon or metal. Do not power on the receiver during the setup process to prevent loss of control. FS-R7P Receiverhttp://www.flysky-cn.comCopyright 2021 Flysky Technology co., ltd Certifications FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Hereby, [Flysky Technology co., ltd] declares that the Radio Equipment [FS-R7P] is in compliance with RED 2014/53/EU. The full text of the EU DoC is available at the following internet address: www.flysky-cn.com. EU DoC Declaration RF Exposure Compliance This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Environmentally friendly disposal Old electrical appliances must not be disposed of together with the residual waste, but have to be disposed of separately. The disposal at the communal collecting point via private persons is for free. The owner of old appliances is responsible to bring the appliances to these collecting points or to similar collection points. With this little personal effort, you contribute to recycle valuable raw materials and the treatment of toxic substances. FCC ID: 2A2UNR7P00 ManufacturerFLYSKY Technology Co., Ltd Address: 16F, Huafeng Building, 6006 Shennan Road, Futian District, Shenzhen Figures and illustrations in this manual are provided for reference only and may differ from actual product appearance. Product design and specificatiions may be changed without notice. FS-R7P Receiverhttp://www.flysky-cn.comCopyright 2021 Flysky Technology co., ltd