GLD2100 Wi-Fi Water Leak Detector User Guide WELCOME Congratulations on your purchase of this Wi-Fi water leak detector. This sensor keeps an eye on your home or business, sending you alert notification at the first sign of water leaks, which can help stop a leak before it becomes a flood. It is also equipped a float switch to sense the level of liquid. IN THE BOX Wi-Fi water leak detector LR03 AAA Battery x2 Sensing Disc x1 Double-sides adhesive tap User guide Optional. Liquid Level Sensor (float switch) SPECIFICATIONS Power Supply:
DC 3V (LR03 AAA Battery x2) Standby Current: <40uA Alarm Current:
<100mA Wi-Fi Frequency: 2.4GHz Wi-Fi: IEEE802.11b/g/n Low Battery Alarm: 2.4V Operation Temperature: -10~55 AT A GLANCE 1.Buzzer 2.Indicator 3.Test/Mute/Volume button 4.Battery receptacle 5.Mounting bracket (rear cover) 6.Leak/Liquid level sensor Port x2 7.Water leakage rope Indicator What You See What It Means Blinking Wi-Fi connection configuration in EZ blue quickly mode Blinking blue Wi-Fi connection configuration in AP slowly mode Blinking red Alarming in case of water leaking Flashes red Low battery once per 60s Install APP Scan this QR code or search
"Smart Life" in the APP market to get the app and install it. For new users using the APP for the first time, please follow the app instructions to complete user registration. HOW TO CONNECT TO WI-FI With EZ Mode (Default). STEP 1. Power your sensor, press and hold the button until the indicator blinks blue quickly (0.25s on and 0.25s off), then it is ready to be connected. STEP 2. On App home page, tap + icon, select Sensors from Add Manually, then select Flood Detector(Wi-Fi) from devices list. STEP 3. Choose your local 2.4GHz Wi-Fi ( NOT 5GHz) and input password,then choose EZ Mode (default) in the top right corner, then follow on-screen instructions in the app to complete the connection. IMPORTANT: Please turn to AP Mode to connect again if the connection fails in EZ Mode. Or with AP Mode. STEP 1. One more time, press and hold the button until the indicator blinks blue slowly (1s on and 1s off), then it is ready to be connected using AP mode. STEP 2. Do the same step 2 in EZ mode, then in the top right corner, choose AP Mode, then follow on-screen instructions in the app to complete the connection. Home Page Notification Setting Lower battery. Turn on/off notification push for low battery. Leak alarm. Turn on/off notification push for water leak. PLACEMENT The water leakage induction rope is installed or placed flat at the lowest place or under the water leakage point to be monitored, and the water leakage induction rope is close to the place where water leakage is likely to occur. Install the water alarm on the wall with double-sided tape.. Water leakage sensor rope detects water leakage ADJUST ALARM VOLUME Double click the button within 0.5s to adjust alarm volume cycling through HIGH-MEDIUM-LOW-MUTE, and default volume is high. While the sensor is set in NOT MUTE mode, it sounds continous beep alarm and the indicator flashes red quickly in case of water leaking, and flashes only in MUTE mode. TEST/MUTE SENSOR Without alarm, click the button to test buzzer(only in NOT MUTE mode) and indicator for 1s. In case of alarm, click the button to hush the alarm. REPLACE THE BATTERY While the sensor is low battery, the indicator may flash and beep once per minute and a low battery notification is pushed to you, indicating that it needs to replace the battery soon reasonable frequency harmful FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide protection againstharmful interference in a residential installation. This equipment generates, with energy uses and can radiateradio and, maycause interference the there thatinterference occur is equipment cause determined by turning the equipmentoff interference Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is harmfulinterference to radio or television reception, which can be user in communications. installation. instructions, guarantee does accordance However, this If thefollowing measures:
radio a encouraged if to in particular installed correct more used one and and will not not the on, the try no by or to to of is connected. Consult the dealer or an experienced radio/TV technician for help. Any Caution:
could void your authority to operate this equipment. modications changes this or to device not explicitly approved by manufacturer 15 part with complies device This conditions:
(1)This interference received, including interference that may cause undesired operation. interference, Operation harmful subject device device Rules. cause may and FCC this not the
(2) to of is the following two must accept any complies equipment FCC This environment. should between the radiator and your body. equipment with This radiation be installed exposure and limits operated set with forth for an minimum uncontrolled 20cm distance