MC612V D RC GENERALGUIDELINESFORINSTALLATION INSTALLATION Lighting Control Switch USERS MANUAL Model No.:MC612V D RC MC612V D RC 1, The sensor should be installed by a qualified electrician. And ensure that the electricity supply is switched off before installing or servicing the product. 2, The company does not accept responsibility for any consequences resulting from unauthorized modification of the product. 3, MC612V D RC should be connected to a stable power supply of 120/277Vac, 50Hz/60Hz. 4, Microwaves cannot pass through metal or brick walls if thicker than 20cm. They will pass through thinner walls but there will be some attenuation. 5, Installation inside a glass or plastic housing will result in a reduction of detection sensitivity. Expect a reduction of approximately 20% for every 3mm of thickness. 6, The sensor is designed for indoor use only. The raining or wind blowing may trigger the Lighting Control Switch even if without human motion when outdoor use. 7, Detection area will be affected by speed of motion,height of installation and volume of moving object. 8, Daylight sensor was tested on sunny environment with no lampshade. INSTALLATION & WIRING The sensor has 6-position terminal blocks :
L(Phase) N(Neutral) L (Switched phase / control) 0-10V(+,-) (Connected to 0-10V interface) The sensor is designed for installation at 8.2ft~26.2ft
/2.5-8m in height. Use 10-18 AWG copper wire only, both solid and stranded MC612V D RC MI20180131A0 Main sensor installation Detachable sensor installation method 1 Main sensor installation Detachable sensor installation method 2 Install the sensor on the LED plate by using 2 screws Make two holes on the LED plate , push the sensor into the holes. Install the sensor on the LED plate by using 2 screws Step 1: Cut the following buckle and the little part off. The hole dimension:
0.12in/3mm 0.55in/14mm The hole dimension:
9mm
(0.35in) 3mm
(0.12in) the little part the following buckle Step 2: Place the sensor towards to the floor and fix it on the LED plate by screws. The hole of the wire is 0.15in/3.7mm. M0.12x0.31in/3.0x8mm Screw 2X M0.12x0.31in/3.0x8mm Screw 2X M0.1x0.31in/2.5x8mm Screw 2X WIRING SCHEME FEATURES Sensor parameters can be conveniently set by a remote controller. The mini motion detector is separately from sensor power part, it will be easier to fix motion detector on the surface of tri-proof light and hidden the power part behind it. This sensor is particularly designed for the lights which have limited space, for examples, LED linear, batten, and LED tri-proof lights. Using pluggable design between motion detector and power part, easy to reinstall or maintain. 0-10V interface can match up with Merrytek stand-alone daylight harvesting sensor Ms01. SPECIFICATIONS Operating voltage 120/277Vac, 50/60Hz Rated Load HF system 120Vac 50/60Hz 3.6A Ballast;
277Vac 50/60Hz 3.4A Ballast 5.8GHz75MHz, ISM wave band Transmitting power
<0.5mW Power consumption 1.0W(stand-by) Detection Range(Diameter) 39.4ft/12m Max. Max. Mounting height 26.2ft/8m Hold time Stand-by Period Sensor: 8S/30S/1min/5min/10min/15min/30min Remote control: 8S/1min/5min/15min/30min Sensor: 0S/1min/3min/5min/10min/30min/+
Remote Control: 0S/1min/5min/30min/+
Stand-by DIM Level Sensor: 10%/20%/30%/40%
Remote Control: 10%/20%/30%/40%/50%
Daylight sensor Sensor: 5lux/15Lux/30Lux/50Lux/100lux/150lux/Disable Remote Control: 5lux/15Lux/50Lux/150lux/Disable Operating temperature
-35C~70C IP rating UL file number IP20
E489677 DETECTION PATTERN Fast walk Slow walk SETTINGS Detection area, hold time and daylight sensor can be set by using DIP switches on the sensor. Note that reducing the detection area will also reduce the sensitivity. 100%
75%
25%50%
32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m 100%
75%
50%
25%
32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m Mounting height:9.8ft/3M Fast walk Slow walk 100%
75%
50%
100%
75%
50%
32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m 32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m 1, Detection area I: up to 100%
II: up to 75%
III: up to 50%
IV: up to 25%
2, Hold time Refers to the time period the lamp remains at 100% illumination after no motion is detected. I: 8s II: 30s III: 1min IV: 5min V: 10min VI:15min VII:30min
(Note: Please do not set the detection sensitivity to 25% when mounting at the height of 19.7ft/6m) Mounting height:19.7ft/6M Fast walk Slow walk 3, Stand-by period Refers to the time period the lamp remains at a pre-setting dimming level before it completely switches off in the long absence of people. 100%
100%
32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m 32.8ft 10m 26.2ft 8m 19.7ft 6m 13.1ft 4m 6.6ft 2m 6.6ft 2m 13.1ft 4m 19.7ft 6m 26.2ft 8m 32.8ft 10m
(Note: Please do not set the detection sensitivity to 25%/50%/75% when mounting at the height of 26.2ft/8m) Mounting height:26.2ft/8M I: 0s II: 1min III: 3min IV: 5min V: 10min VI: 30min VII: +
* When set to + mode, the low light is maintained until motion is detected. SECSECSEC 0-10V Dimmable 0-10V Dimmable 0-10V Dimmable LED Driver LED Driver LED Driver 4,Stand-by dimming level This is the pre-setting dimming level you would like to have after the hold time in the long absence of people. I: 10%
II: 20%
III: 30%
IV: 40%
40%
5,Daylight sensor The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold. The settings are as follows:
8S I: 5lux, darkness operation only II: 15lux, darkness operation only III: 30lux, twilight operation IV: 50lux, twilight operation V: 100lux, twilight operation VI: 150lux,twilight operation VII: Disable
*When set to Disable, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light levels.
*It should be set to Disable mode if the motion sensor is connected to stand-alone daylight sensors. Remote Control Setting Button Name Description Transmit Uploads the settings Detection Area 25%/50%/75%/100%
Hold time The timeout from 100% to dim 8S/1min/5min/15min/30min Daylight Threshold 5Lux/15Lux/50Lux/150Lux/ Disable Stand-by period The timeout from dim to off 0S/1min/5min/30min/+
Stand-by DIM level 10%/20%/30%/40%/50%
NOTE1 Sensor module Metal fitting Side wave Main wave FCC Warnning:
Microwave detection includes two parts called main wave and side wave. Main wave normally detects the motion signal. Side wave does not effect motion detection but might disturb main wave if the microwave motion sensor is built-in a sealed metal luminaire as microwave can not pass through metal. When the microwave module is built into a metal lighting luminaire or installed in a sensor near a wall, the side wave will be reflected by the metal base or the wall. It can disturb the main wave. As the result of this, the microwave motion senor might not perform optimally. Reducing the detection sensitivity or the side wave will help to solve such problems. Auto mode A. Movement Motion detect 9.8ft~19.7ft/3-6m B. Presence detect 9.8ft~19.7ft/3-6m C. Presence detect with daylight harvesting 9.8ft~19.7ft/3-6m D. High mounting: 19.7ft~49.2ft/6-15m E. High mounting with daylight harvesting : 19.7ft~49.2ft/6-15m ON-OFF Permanent ON/OFF Reset Press Reset button for factory testing purpose only. Detection Area 100%
Hold Time 1min Daylight sensor Disable Stand-by period 3min Stand-by dim level 20%
Ambient Threshold Press this button to set the current suitable daylight threshold. Dim+ / Dim -
Adjust the light level when motion detected. 1/2/3/4 4 optional quick settings As the control angle of the Infrared Remote Control is fixed (30), if the sensors are installed too close to each other, the settings of both sensors will be configured. Please refer to the below chart for the distance of the installation of each sensor:
Mounting height Distance between each sensor 26.2ft/8m 14ft/4.28m 19.7ft/6m 10.5ft/3.2m 9.8ft/3m 5.2ft/1.6m 8.2ft/2.5m 4.3ft/1.32m Distance between each sensor This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution:
Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. ISED Statement English: This device complies with Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES3 (B)/NMB3(B). French: Le prsentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitationestautorise aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareildoit accepter tout brouillageradiolectriquesubi, mmesi le brouillageest susceptible d'encompromettre le fonctionnement. Radiation Exposure Statement This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Dclaration d'exposition aux radiations Cet quipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrl. Cet quipement doit tre install et utilis distance minimum de 20cm entre le radiateur et votre corps. Motion sensor Motion sensor 15 15 No.3 Building, 380 Xiangshan Avenue, No.3 Industrial Park Luotian, Songgang Town, Baoan District, Shenzhen 518105, Guangdong, China www.merrytek.com Email:sales@merrytek.com Shenzhen Merrytek Technology Co..Ltd
*Note 1: MH02 is a common used remote control for a various of sensor, MC612V D RC only works under Mode A.
*Note 2: 1/2/3/4: These 4 optional quick setting are factory default settings, see table chart 1 below. 1. Factory default settings:
According to the default settings, short press 1/2/3/4, then press to transmit. 2. Modification:
Short press 1/2/3/4 number key, select your own sensor settings such as "Detection Range /
Hold Time / Daylight Sensor / Stand-by Period / Stand-by Dimming Level" , then press to transmit. 3. Save the modification:
After you have set the customized parameters, long press the numeric keys 1/2/3/4 number key for more than 3s and will save the current settings to the 1/2/3/4 number key. Quick Setting 1 2 3 4 Detection Area 100%
100%
100%
100%
Hold Time 8S 8S 1min 5min Daylight sensor Disable 5Lux 15Lux 50Lux Stand-by period Stand-by dim level 0S 1min 1min 30min 10%
10%
10%
10%
(Table chart 1: 1/2/3/4 Quick Setting for MC612V D RC) FAQ Question The load will not illuminate Cause Incorrect daylight sensor setting selected. Load has failed. Power is switched off. Continuous movement in the detection area. The lamp (containing sensor) is installed in an area too close to reflective surfaces, i.e. metal, glass or concrete walls. Speed of moving object is not in the range of 0.5-3m/s or the detection radius is too small. The battery on the remote control is run out. The remote control is not aligned with sensor. The load is permanently illuminated. The load will not illuminate despite movement. The remote control is not working. Remedy Adjust setting. Replace load. Switch on. Check detection area setting. 1, Make sure installation area suitable with at least 30cm space between lamp and surrounding reflective surfaces. 2, Reduce sensitivity (detection area). Check detection area setting. Change the battery. Change the remote angle.