all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
15 MP-226 UserMan-US | Users Manual | 96.81 KiB | May 08 2019 | |||
1 |
|
09 MP-226 IntPho | Internal Photos | 632.13 KiB | May 08 2019 | |||
1 |
|
08 MP-226 ExtPho | External Photos | 570.22 KiB | May 08 2019 | |||
1 |
|
06 MP-226 LabelSmpl-US | ID Label/Location Info | 66.60 KiB | May 08 2019 | |||
1 |
|
10 MP-226 TSup | Test Setup Photos | 244.08 KiB | May 08 2019 | |||
1 | 11 MP-226 OpDes | Operational Description | August 05 2019 | confidential | ||||
1 | 12 MP-226 BlkDia | Block Diagram | August 05 2019 | confidential | ||||
1 | 13 MP-226 Schem | Schematics | August 05 2019 | confidential | ||||
1 |
|
14 MP-226 TestRpt DCD r2 | Test Report | 2.32 MiB | May 08 2019 | |||
1 |
|
17 MP-226 AntSpec | Operational Description | 12.18 KiB | May 08 2019 | |||
1 |
|
18 MP-226 RFExp | RF Exposure Info | 709.21 KiB | May 08 2019 |
1 | 15 MP-226 UserMan-US | Users Manual | 96.81 KiB | May 08 2019 |
MP-226 Wireless Charging Pad INSTRUCTION MANUAL PLEASE READ ALL INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE USE Getting started Remove the product from the box. Remove any packaging from the product. Please retain all packaging after you have checked and counted all the parts and the contents against the list. Package Contents Wireless Charging Pad USB cable Instruction Manual Key Features Convenient and fast charging Wireless charger: Now, charge your phone by placing it on the pad. No need to attach any cable to your phone. Built-in Blue LED indicator for charging Compatible with Qi Integrated phones like Samsung Galaxy S6/S7/S8/S9/S10, Iphone 8/8Plus/X/XR/XS 1 Description of Parts:
INSTRUCTIONS FOR USE Charging Instructions Connect the USB cable (included) to a power outlet rated DC 5V 2A, and the Micro USB plug to the Micro USB input of the Wireless Charging Pad. Red LED indicator turns on. Place your Qi Integrated phone on the non slip pad, and wireless charging of the phone will start immediately with auto-change of Blue LED indicator light intensity. Specifications Input: DC 5V/2A Output: DC 5V/1A Coil: Single coil FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 2 communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving an Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. tenna. 3
1 | 06 MP-226 LabelSmpl-US | ID Label/Location Info | 66.60 KiB | May 08 2019 |
Label Location On EUT Label Product Name: Wireless Charging Pad Model No.: MP-226 FCC ID: 2AOV6-MP226 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
1 | 10 MP-226 TSup | Test Setup Photos | 244.08 KiB | May 08 2019 |
FCC ID: 2AOV6-MP226 Photo of Conducted Emission Measurement Photo of Radiation Emission Test
1 | 14 MP-226 TestRpt DCD r2 | Test Report | 2.32 MiB | May 08 2019 |
Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 1 of 32 FCC TEST REPORT Client Name
: Shenzhen Minsuo Industrial Co.,Ltd Address
:
12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China Product Name
: Wireless Charging Pad Date
: Jul. 31, 2019 Shenzhen Anbotek Compliance Laboratory Limited Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 2 of 32 Contents 1. General Information...............................................................................................................................................4 1.1. Client Information....................................................................................................................................... 4 1.2. Description of Device (EUT).....................................................................................................................4 1.3. Auxiliary Equipment Used During Test................................................................................................... 4 1.4. Description of Test Modes........................................................................................................................ 5 1.5. Description Of Test Setup......................................................................................................................... 6 1.6. Test Equipment List....................................................................................................................................7 1.7. Measurement Uncertainty.........................................................................................................................8 1.8. Description of Test Facility........................................................................................................................8 2. Summary of Test Results..................................................................................................................................... 9 3. Conducted Emission Test...................................................................................................................................10 3.1. Test Standard and Limit.......................................................................................................................... 10 3.2. Test Setup..................................................................................................................................................10 3.3. Test Procedure..........................................................................................................................................10 3.4. Test Data....................................................................................................................................................10 4. Radiation Spurious Emission and Band Edge................................................................................................15 4.1. Test Standard and Limit.......................................................................................................................... 15 4.2. Test Setup..................................................................................................................................................15 4.3. Test Procedure..........................................................................................................................................16 4.4. Test Data....................................................................................................................................................17 5. Antenna Requirement......................................................................................................................................... 23 5.1. Test Standard and Requirement............................................................................................................23 5.2. Antenna Connected Construction..........................................................................................................23 APPENDIX I -- TEST SETUP PHOTOGRAPH...................................................................................................24 APPENDIX II -- EXTERNAL PHOTOGRAPH..................................................................................................... 26 APPENDIX III -- INTERNAL PHOTOGRAPH..................................................................................................... 30 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 3 of 32 TEST REPORT Applicant
: Shenzhen Minsuo Industrial Co.,Ltd Manufacturer
: Shenzhen Minsuo Industrial Co.,Ltd Product Name
: Wireless Charging Pad Model No.
: MP-226 Trade Mark
: N.A. Rating(s)
:
Input: 5V Output: 5V 2A 1A Test Standard(s) Test Method(s)
: FCC Part15 Subpart C 2018, Paragraph 15.209
: ANSI C63.10: 2013 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. Date of Receipt Date of Test Prepared By Reviewer Jun. 27, 2019 Jun. 27~Jul. 19, 2019
(Engineer / Oliay Yang)
(Supervisor / Snowy Meng) Approved & Authorized Signer
(Manager / Sally Zhang) Code:AB-RF-05-a Report No.: SZAWW190627001-01 1. General Information 1.1. Client Information FCC ID: 2AOV6-MP226 Page 4 of 32 Applicant Address Manufacturer Address Factory Address
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China 1.2. Description of Device (EUT) Product Name Model No. Trade Mark Test Power Supply Test Sample No.
: Wireless Charging Pad
: MP-226
: N.A.
: AC 240V, 60Hz for adapter/ AC 120V, 60Hz for adapter
: 1-2-1(Normal Sample), 1-2-2(Engineering Sample) Operation Frequency:
110.1-205KHz Product Description
:
Modulation Type:
Antenna Type:
MSK Inductive loop coil Antenna Antenna Gain(Peak):
0 dBi Remark: 1) For a more detailed features description, please refer to the manufacturers specifications or the Users Manual. 1.3. Auxiliary Equipment Used During Test Adapter
:
Manufacturer: Samsung M/N: ETA-U90CBC S/N: RT6FB17ZS/B-E Input: 100-240V~ 50-60Hz, 0.35A Output: DC 5V, 2A Mobile Phone
:
iPhone 7 Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Report No.: SZAWW190627001-01 1.4. Description of Test Modes To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Page 5 of 32 Pretest Mode Mode 1 Final Test Mode Mode 1 Final Test Mode Mode 1 Description Full load, wireless charger module For Conducted Emission Description Full load, wireless charger module For Radiated Emission Description Full load, wireless charger module Note: (1)Test channel is 0.1499MHz.
(2) All the situation(full load, half load and empty load) has been tested,only the worst situation (full load) was recorded in the report. Code:AB-RF-05-a Report No.: SZAWW190627001-01 1.5. Description Of Test Setup FCC ID: 2AOV6-MP226 Page 6 of 32 Table Table CE 0.8m RE 0.8m USB E-1 EUT Mobile Phone E-2 Adapter AC Line LISN 1.5m USB E-1 EUT Mobile Phone E-2 Adapter AC Line Table Table 1.5m Code:AB-RF-05-a Report No.: SZAWW190627001-01 1.6. Test Equipment List FCC ID: 2AOV6-MP226 Page 7 of 32 Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval L.I.S.N. Artificial Mains Rohde & Schwarz ENV216 100055 Nov. 26, 2018 1 Year Network EMI Test Receiver Rohde & Schwarz ESPI3 101604 Nov. 05, 2018 1 Year RF Switching Unit Spectrum Analysis MAX Spectrum Analysis Compliance Direction Agilent RSU-M2 38303 Nov. 05, 2018 1 Year E4407B US39390582 Nov. 05, 2018 1 Year Agilent N9020A MY51170037 Nov. 05, 2018 1 Year Preamplifier SKET Electronic BK1G18G30 D KD17503 Nov. 05, 2018 1 Year Double Ridged Horn Antenna Bilog Broadband Antenna Instruments corporation GTH-0118 351600 Nov. 20, 2018 1 Year Schwarzbeck VULB9163 VULB 9163-289 Nov. 19, 2018 1 Year Loop Antenna Schwarzbeck Horn Antenna A-INFO FMZB1519B LB-180400-
KF 310N N/A 00053 Nov. 20, 2018 1 Year J211060628 Nov. 20, 2018 1 Year 186860 Nov. 05, 2018 1 Year N/A N/A N/A SONOMA SHURPLE Pre-amplifier EMI Test Software EZ-EMC RF Test Control System Power Sensor Power Sensor MXA Spectrum Analysis MXG RF Vector Signal Generator Signal Generator DC Power Supply Constant Temperature Humidity Chamber YIHENG YH3000 2017430 Nov. 05, 2018 1 Year DAER DAER Agilent Agilent Agilent LW RPR3006W 15I00041SN045 Nov. 05, 2018 1 Year RPR3006W 15I00041SN046 Nov. 05, 2018 1 Year N9020A MY51170037 Nov. 05, 2018 1 Year N5182A MY48180656 Nov. 05, 2018 1 Year E4421B TPR-6420D MY41000743 Nov. 05, 2018 1 Year Oct. 31, 2018 1 Year 374470 ZHONGJIAN ZJ-KHWS80 B N/A Nov. 01, 2018 1 Year Code:AB-RF-05-a 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Report No.: SZAWW190627001-01 1.7. Measurement Uncertainty FCC ID: 2AOV6-MP226 Page 8 of 32 Radiation Uncertainty
: Ur = 3.9 dB (Horizontal) Ur = 3.8 dB (Vertical) Conduction Uncertainty
: Uc = 3.4 dB 1.8. Description of Test Facility The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration No. 184111, September 30, 2018. ISED-Registration No.: 8058A-1 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from the ISED is maintained in our files. Registration 8058A-1, March 07, 2019. Test Location Shenzhen Anbotek Compliance Laboratory Limited. 1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong, China.518102 Code:AB-RF-05-a Report No.: SZAWW190627001-01 2. Summary of Test Results FCC ID: 2AOV6-MP226 Page 9 of 32 Standard Section Test Item FCC Part 15, Paragraph 15.207 Conducted Emission Test FCC Part 15, Paragraph 15.209(a)(f) Part 15.203 Spurious Emission Antenna Requirement Result PASS PASS PASS Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Page 10 of 32 Report No.: SZAWW190627001-01 3. Conducted Emission Test 3.1. Test Standard and Limit Test Standard FCC Part15 Section 15.207 Test Limit Frequency 150kHz~500kHz 500kHz~5MHz 5MHz~30MHz Maximum RF Line Voltage (dBuV) Quasi-peak Level 66 ~ 56 *
Average Level 56 ~ 46 *
56 60 46 50 Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency. 3.2. Test Setup 3.3. Test Procedure The EUT system is connected to the power mains through a line impedance stabilization network
(L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to FCC ANSI C63.10-2013 on Conducted Emission Measurement. The bandwidth of test receiver (ESCI) set at 9kHz. The frequency range from 150kHz to 30MHz is checked. 3.4. Test Data Please to see the following pages Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Page 11 of 32 Report No.: SZAWW190627001-01 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Mode 1 AC 240V, 60Hz for adapter Live Line Tem.: 22.3 Hum.: 63%
Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Page 12 of 32 Report No.: SZAWW190627001-01 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Mode 1 AC 240V, 60Hz for adapter Neutral Line Tem.: 22.3 Hum.: 63%
Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Page 13 of 32 Report No.: SZAWW190627001-01 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Mode 1 AC 120V, 60Hz for adapter Live Line Tem.: 22.3 Hum.: 63%
Code:AB-RF-05-a FCC ID: 2AOV6-MP226 Page 14 of 32 Report No.: SZAWW190627001-01 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Mode 1 AC 120V, 60Hz for adapter Neutral Line Tem.: 22.3 Hum.: 63%
Code:AB-RF-05-a Report No.: SZAWW190627001-01 4. Radiation Spurious Emission and Band Edge 4.1. Test Standard and Limit FCC ID: 2AOV6-MP226 Page 15 of 32 Test Standard FCC Part15 C Section 15.209 and 15.205 Field strength Frequency Limit
(MHz)
(microvolt/meter)
(dBuV/m) Remark Measurement distance (m) Test Limit 0.009MHz~0.490MHz 0.490MHz-1.705MHz 2400/F(kHz) 24000/F(kHz) 1.705MHz-30MHz 30MHz~88MHz 88MHz~216MHz 216MHz~960MHz 960MHz~1000MHz Above 1000MHz 30 100 150 200 500 500
-
-
-
-
40.0 43.5 46.0 54.0 54.0 74.0
-
-
-
Quasi-peak Quasi-peak Quasi-peak Quasi-peak Average Peak 300 30 30 3 3 3 3 3 3 Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum permitted average emission limit applicable to the equipment under test. This peak limit applies to the total peak emission level radiated by the device. 4.2. Test Setup Figure 1. Below 30MHz Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 16 of 32 Figure 2. 30MHz to 1GHz Figure 3. Above 1 GHz 4.3. Test Procedure For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane. For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation. Code:AB-RF-05-a Report No.: SZAWW190627001-01 For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. FCC ID: 2AOV6-MP226 Page 17 of 32 For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. 4.4. Test Data PASS Note: The data is in TX mode, and this is the worst mode. Code:AB-RF-05-a Report No.: SZAWW190627001-01 Test Results
(Between 9KHz 30MHz) FCC ID: 2AOV6-MP226 Page 18 of 32 Test Mode:
Power Source:
Temp.()/Hum.(%RH):
Mode 1 AC 120V, 60Hz for adapter 25.4/54%RH RemarkAccording to FCC PART 15.209 (d), the emission limits for the frequency bands 990 kHz, 110490 kHz and above 1000 MHz, Radiated emission limits in these three bands are based on measurements employing an average detector. Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 19 of 32
(Between 30MHz 1000 MHz) Test Mode:
Power Source:
Polarization:
Temp.()/Hum.(%RH):
Mode 1 AC 240V, 60Hz for adapter Horizontal 24.9/51%RH Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 20 of 32 Test Mode:
Power Source:
Polarization:
Temp.()/Hum.(%RH):
Mode 1 AC 240V, 60Hz for adapter Vertical 24.9/51%RH Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 21 of 32 Test Mode:
Power Source:
Polarization:
Temp.()/Hum.(%RH):
Mode 1 AC 120V, 60Hz for adapter Horizontal 24.9/51%RH Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 22 of 32 Test Mode:
Power Source:
Polarization:
Temp.()/Hum.(%RH):
Mode 1 AC 120V, 60Hz for adapter Vertical 24.9/51%RH Code:AB-RF-05-a Report No.: SZAWW190627001-01 5. Antenna Requirement 5.1. Test Standard and Requirement FCC ID: 2AOV6-MP226 Page 23 of 32 Test Standard Requirement FCC Part15 Section 15.203 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. 5.2. Antenna Connected Construction The antenna is a Inductive loop coil Antenna which permanently attached, and the best case gain of the antenna is 0 dBi. It complies with the standard requirement. Antenna Code:AB-RF-05-a Report No.: SZAWW190627001-01 APPENDIX I -- TEST SETUP PHOTOGRAPH FCC ID: 2AOV6-MP226 Page 24 of 32 Photo of Conducted Emission Measurement Photo of Radiation Emission Test Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 25 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 APPENDIX II -- EXTERNAL PHOTOGRAPH FCC ID: 2AOV6-MP226 Page 26 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 27 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 28 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 29 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 APPENDIX III -- INTERNAL PHOTOGRAPH FCC ID: 2AOV6-MP226 Page 30 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 31 of 32 Code:AB-RF-05-a Report No.: SZAWW190627001-01 FCC ID: 2AOV6-MP226 Page 32 of 32
---------------- End of Report ----------------
Code:AB-RF-05-a
1 | 17 MP-226 AntSpec | Operational Description | 12.18 KiB | May 08 2019 |
Shenzhen Minsuo Industrial Co.,Ltd Declaration concerning Antenna Specification It is hereby declared that the product Model No.: MP-226 FCC ID : 2AOV6-MP226 fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal antenna type(s) described below:
Model No. of antenna: N/A Type of antenna:
Inductive loop coil Antenna Gain of the antenna: 0 dBi Frequency range: 110.1-205KHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Shenzhen Minsuo Industrial Co.,Ltd Address: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China City:
Shenzhen ZIP / Postal code:
Country:
China Place:
Shenzhen Date: 2019-08-01 Signature:
version01
1 | 18 MP-226 RFExp | RF Exposure Info | 709.21 KiB | May 08 2019 |
Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 1 of 13 FCC TEST REPORT Client Name
: Shenzhen Minsuo Industrial Co.,Ltd Address
:
12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China Product Name
: Wireless Charging Pad Date
: Jul. 31, 2019 Shenzhen Anbotek Compliance Laboratory Limited Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 2 of 13 Contents 1. General Information...............................................................................................................................................4 1.1. Client Information....................................................................................................................................... 4 1.2. Description of Device (EUT).....................................................................................................................4 1.3. Auxiliary Equipment Used During Test................................................................................................... 4 1.4. Test Equipment List....................................................................................................................................5 1.5. Measurement Uncertainty.........................................................................................................................5 1.6. Description of Test Facility........................................................................................................................5 2. Measurement and Result..................................................................................................................................... 6 2.1. Requirements..............................................................................................................................................6 2.2. Test Setup....................................................................................................................................................7 2.3. Test Procedure............................................................................................................................................7 2.4. Test Result...................................................................................................................................................7 2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03.......................................7 2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(b), 1.1310.................................................................................................................................................................. 9 APPENDIX I -- TEST SETUP PHOTOGRAPH...................................................................................................11 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 3 of 13 TEST REPORT Applicant
: Shenzhen Minsuo Industrial Co.,Ltd Manufacturer
: Shenzhen Minsuo Industrial Co.,Ltd Product Name
: Wireless Charging Pad Model No.
: MP-226 Trade Mark
: N.A. Rating(s)
:
Input: 5V Output: 5V 2A 1A Test Standard(s) Test Method(s)
: FCC Part 1.1310, 1.1307(b)
: KDB680106 D01 RF Exposure Wireless Charging Apps v03 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 1.1307 & KDB680106 D01 requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. Date of Receipt Date of Test Prepared By Reviewer Jun. 27, 2019 Jun. 27~Jul. 19, 2019
(Engineer / Oliay Yang)
(Supervisor / Snowy Meng) Approved & Authorized Signer
(Manager / Sally Zhang) Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 4 of 13 1. General Information 1.1. Client Information Applicant Address Manufacturer Address Factory Address
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China
: Shenzhen Minsuo Industrial Co.,Ltd
: 12th floor, Block B, Tengyao Building, No. 268 Gushu 2nd road,Xixiang Town, Bao'an, Shenzhen, Guangdong, China 1.2. Description of Device (EUT) Product Name Model No. Trade Mark Test Power Supply Test Sample No.
: Wireless Charging Pad
: MP-226
: N.A.
: AC 120V, 60Hz for adapter
: 1-2-1(Normal Sample), 1-2-2(Engineering Sample) Operation Frequency:
110.1-205KHz Product Description
:
Modulation Type:
Antenna Type:
MSK Inductive loop coil Antenna Antenna Gain(Peak):
0 dBi Remark: 1) For a more detailed features description, please refer to the manufacturers specifications or the Users Manual. 1.3. Auxiliary Equipment Used During Test Adapter
:
Manufacturer: Samsung M/N: ETA-U90CBC S/N: RT6FB17ZS/B-E Input: 100-240V~ 50-60Hz, 0.35A Output: DC 5V, 2A Mobile Phone
:
iPhone 7 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 5 of 13 1.4. Test Equipment List Item Equipment Manufacturer 1 Magnetic field meter 2 3 E-Field Probe H-Field Probe NARDA Narda Narda Model No. ELT-400 EF0391 HF3061 Serial No. 423623 Q15221 Q15835 Last Cal. Cal. Interval Dec. 24, 2018 Nov.17, 2017 Nov.17, 2017 1 Year 3 Year 3 Year 1.5. Measurement Uncertainty Radiation Uncertainty
: Ur = 3.9 dB (Horizontal) Ur = 3.8 dB (Vertical) Conduction Uncertainty
: Uc = 3.4 dB 1.6. Description of Test Facility The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration No. 184111, September 30, 2018. ISED-Registration No.: 8058A-1 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from the ISED is maintained in our files. Registration 8058A-1, March 07, 2019. Test Location Shenzhen Anbotek Compliance Laboratory Limited. 1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong, China. 518102 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 6 of 13 2. Measurement and Result 2.1. Requirements According to the item 5.b) of KDB 680106 D01v03:
Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. 1) Power transfer frequency is less that 1 MHz 2) Output power from each primary coil is less than or equal to 15 watts. 3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils 4) Client device is inserted in or placed directly in contact with the transmitter 5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion) 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Limits For Maximum Permissible Exposure (MPE) Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 7 of 13 2.2. Test Setup 20cm 15 cm Note: Measurements should be made at 15 cm surrounding the EUT and 20cm above the top surface of the EUT. 2.3. Test Procedure 1) The RF exposure test was performed in anechoic chamber. 2) The measurement probe was placed at required test distance which is between the edge of the charger and the geometric center of probe. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points
(A, B, C, D, E) were completed.(A is the right, B is the back, C is the left, D is the front, and E is the top.) 4) The EUT was measured according to the dictates of KDB 680106 D01 v03. Remark;
The EUTs test position A, B, C, D and E is valid for the E and H field measurements. 2.4. Test Result 2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03. 1) Power transfer frequency is less that 1 MHz
- The device operate in the frequency range 110.1-205KHz. 2) Output power from each primary coil is less than 15 watts
- The maximum output power of the primary coil is 5W. Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 8 of 13 3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils
- The transfer system including a charging system with only single primary coils is to detect and allow only between individual pairs of coils. 4) Client device is inserted in or placed directly in contact with the transmitter
- Client device is placed directly in contact with the transmitter. 5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
- The EUT is a Mobile Power Pack with Wireless Charger 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
- Conducted the measurement with the required distance and the test results please refer to the section 2.4. Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 9 of 13 2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(b), 1.1310 Temperature:
Pressure:
23.9C 1012 hPa Relative Humidity:
54 %
Test Voltage:
AC 120V, 60Hz for adapter E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT Battery power Frequency Test Test Test Test Test Reference Range
(KHz) Position Position Position Position Position A B C D E Limit
(V/m) Limits Test
(V/m) 1%
110.1-205 0.36 0.35 0.26 0.41 0.55 307 614 50%
110.1-205 1.44 1.64 1.28 1.36 1.67 307 614 99%
110.1-205 2.27 2.76 2.42 2.38 2.74 307 614 Stand-b y 110.1-205 0.34 0.44 0.54 0.40 0.42 307 614 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 10 of 13 H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT Battery power Frequency Test Test Test Test Test Reference Range
(KHz) Position Position Position Position Position A B C D E Limit
(A/m) Limits Test
(A/m) 1%
110.1-205 0.045 0.053 0.067 0.048 0.054 0.815 1.63 50%
110.1-205 0.27 0.47 0.25 0.33 0.46 0.815 1.63 99%
110.1-205 0.58 0.50 0.47 0.35 0.32 0.815 1.63 Stand-b y 110.1-205 0.45 0.25 0.37 0.56 0.35 0.815 1.63 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 11 of 13 APPENDIX I -- TEST SETUP PHOTOGRAPH Photo of MPE Measurement Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 12 of 13 Code:AB-RF-05-a Report No.: SZAWW190627001-02 FCC ID: 2AOV6-MP226 Page 13 of 13
---------------- End of Report ----------------
Code:AB-RF-05-a
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-05 | 0.1101 ~ 0.205 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-08-05
|
||||
1 | Applicant's complete, legal business name |
Shenzhen Minsuo Industrial Co.,Ltd
|
||||
1 | FCC Registration Number (FRN) |
0027171875
|
||||
1 | Physical Address |
12th floor, Block B, Tengyao Building, No. 268
|
||||
1 |
Shenzhen, Guangdong, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@eurofins.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AOV6
|
||||
1 | Equipment Product Code |
MP226
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
H******** X********
|
||||
1 | Title |
manager
|
||||
1 | Telephone Number |
0755-********
|
||||
1 | Fax Number |
0755-********
|
||||
1 |
s******@minsuo.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Charging Pad | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 | Name |
J****** Z****
|
||||
1 | Telephone Number |
86-75********
|
||||
1 | Fax Number |
86-75********
|
||||
1 |
j******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.11010000 | 0.20500000 | ppm |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC