ModelMS009ER Focus on Intelligent lighting 10mm thickness super compact sensor Shenzhen Mosentek Technology Co.,Ltd. Add: Building No. 3, Room 202, Shanmen community No. 3 industry park, Yanluo street, Baoan district, Shenzhen, P.R.C. Email: sales@mosentek.com Tel: +86 0755 2720 6813 ModelMS009ER Focus on Intelligent lighting Features Super compact sensor module W*L*H 18.5*42*10mm Remote control setting 5V PWM dimming control Daul PD for auto lux on/off Output Microwave frequency 5.8GHz75MHz 12VDC 40mA 5V PWM
<0.3mW 30-150 Technical data Operating voltage Input Operating current Output Microwave power Detection angle Sensitivity Hold time Daylight threshold Stand-by period Mounting height Detection range Size Warranty Sensor Parameters Other 100%/75%/50%/25% (Refer to Remote Control) 5s/1min/3min/10min (Refer to Remote Control) 10Lux/25Lux/50Lux/Disable (Refer to Remote Control) 0s/10s/10min/+ (Refer to Remote Control) Stand-by dimming level 20%/30% (Refer to Remote Control) Max.5m (ceiling mounted); 1.5-1.8m (Wall Mounted Radius, Max.6m (ceiling mounted); Max.10m (Wall Mounted 1.8 Operating temperature
-25C~70C
(L*W*H) 48*24.5*12 mm 5 years Dimension (Unit: mm) Wiring diagram Daylight sensor IR Receiver Installation hole VCC OUT GND MS006R L N L N LED Driver VCC DIM GND LED+
LED-
Antenna module 18.5 42 Shenzhen Mosentek Technology Co.,Ltd. Add: Building No. 3, Room 202, Shanmen community No. 3 industry park, Yanluo street, Baoan district, Shenzhen, P.R.C. Email: sales@mosentek.com Tel: +86 0755 2720 6813
- 01 ModelMS009ER Focus on Intelligent lighting Detection coverage 6m 5m 4m 0m 1m 2m 3m 4m 5m 6m Ceiling Mounted 3m 2m 1m Wall Mounted 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 13m 14m 15m Mounting height 4m 3m 2m 1m 1m 2m 3m 4m Sensitivity :
25%
50%
75%
100%
Sampling time light off automatically light on automatically Sampling time Mounting height 1m 2m 3m 4m 5m 6m 7m 8m Daylight Priority Thanks for the Dual-PD technology, The sensor can tell the difference between natural light and artificial LED light, the sensor will turn on your light fixtures when the ambient light is lower than the setting value even there is no any motion was detected. When the ambient light is up to the setting value, the sensor will switch off the light fixtures even there is still motion. NoteLux-Off sampling time--10s Lux-Off sampling time--10s Lux-On function takes effect only when standby dimming period set at +. Lux off Lux on Application Daylight priority Lux-On function takes effect only when stand-by dimming period set at +. With sufficient daylight, even when motion detected, light remains OFF. Light automatically on and dim to the stand-by dimming levle when ambient brightness is lower than preset lux level. With insufficient ambient brightness, light dims to 100%
when motion was detected . Light keeps on 100% within the holdtime. Light dims to standby level if no motion detected after holdtime. Light off when ambient lux level is higher than preset lux amount even there is still motion. Shenzhen Mosentek Technology Co.,Ltd. Add: Building No. 3, Room 202, Shanmen community No. 3 industry park, Yanluo street, Baoan district, Shenzhen, P.R.C. Email: sales@mosentek.com Tel: +86 0755 2720 6813
- 02 ModelMS009ER Focus on Intelligent lighting ON/OFF function The daylight threshold is set to "10Lux/25Lux/50Lux, Stand-by period is set to "0s". With sufficient daylight, even when motion detected, light With insufficient ambient Light keeps on 100% within the After the last detection and brightness, light dims to 100%
holdtime. the preset hold time elapsed, remains OFF. when motion was detected . light OFF. The daylight threshold is set to "Disable". Light on when detect movement, After people leave, Light off after stand-by period. W h e n m o t i o n i s d e t e c t e d , t h e sensor will switch on the light to 100% brighteness. After people leave the detection area, light remains 100%
brightness within hold time. After the last detection and the present hold time elapsed, light OFF. Dimmable control/Corridor function The daylight threshold is set to "10Lux/25Lux/50Lux, stand-by period is set to "10s/10min". With sufficient daylight, even With insufficient ambient Light keeps on 100% within the when motion detected, light brightness, light dims to 100%
holdtime. remains OFF. when motion was detected . Light dims to standby level if no motion detected after holdtime. After the stand-by period, light OFF. Shenzhen Mosentek Technology Co.,Ltd. Add: Building No. 3, Room 202, Shanmen community No. 3 industry park, Yanluo street, Baoan district, Shenzhen, P.R.C.
- 03 Email: sales@mosentek.com Tel: +86 0755 2720 6813 ModelMS009ER Focus on Intelligent lighting Application Train station, Airport, etc. Industrial Lighting: Factory, Warehouse, etc. Commercial Ligtihng: Office, Supermarket, etc. Public Lighting: Residence, Hospital, School, Metro station Corridor Warehouse Parking Installation precautions Wiring must be strictly in accordance with the wiring diagram to avoid short circuit. The detected surface cannot be shielded by metal objects. Microwave sensor can be installed in any lamp except the one with full metal shell. Should be kept away from the driver to avoid interference generation and lamp flashing. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing. Shenzhen Mosentek Technology Co.,Ltd. Add: Building No. 3, Room 202, Shanmen community No. 3 industry park, Yanluo street, Baoan district, Shenzhen, P.R.C.
- 04 Email: sales@mosentek.com Tel: +86 0755 2720 6813 Caution:
This device complies with Part 15 of the FCC rules and Industry Canada licenseexempt RSS standard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcause harmful interference, and (2) this device must accept any interference received, including interferencethatmaycauseundesiredoperation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment. Such modifications or change could void the users authoritytooperatetheequipment. Thisradiotransmitter(identifythedevicebycertificationnumberormodelnumberifCategoryII) hasbeenapprovedbyIndustryCanadatooperatewiththeantennatypeslistedbelowwiththe maximumpermissiblegainindicated.Antennatypesnotincludedinthislist,havingagaingreater thanthemaximumgainindicatedforthattype,arestrictlyprohibitedforusewiththisdevice. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement. To maintain compliance with FCCs RF exposure guidelines, this equipment should be installedandoperatedwithaminimumdistanceof20cmbetweentheradiatorandyour body. 5G For 5725-5875 frequency band, Operations in the 5725-5875 band are restricted to indoor usage only.