Instruction Manual Door Sensor Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. The Water Leakage Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enable networks. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Product Introduction Door sensor is an intelligent security equipment that can transmit the Z-wave network which has particular frequency. In the Z-wave network communications, door sensor can be connected to any Z-wave main controller. The door sensor can send messages to the Z-wave main controller, and realize association with other devices through the Z-wave main controller. Different countries or areas, the radio frequency is different. In the communication with the Z-wave main controller, the door sensor can send messages to the Z-wave main controller, but it can not receive messages from the Z-wave main controller. When alarm is triggered, the door sensor sends messages to the Z-wave main controller, the Z-wave main controller will displays the current status of door sensor, so the door sensor can associate with other devices. Door sensor is battery powered, is small and can be installed on the window or door easily. When the door or window is open, the door sensor is triggered and linkage alarm realized. Specifications Power Supply Standby Current Work Current(RF Tx) Operational Temperature Communication frequency Range CR123 1 Up to 15mA 0 - 70 868.40MHz, 869.85MHz (EU) 908.40MHz, 916.00MHz(US) Up to 45m indoors (depending on the building structure), and 80m for outdoor open fields. Up to 60m outdoors. Technical Information Install on the door or window. Battery powered. Easily install with screws or sticker. Associate with other devices through the gateway. Compatible with any Z-wave network. It can be powered by USB Product Configuration Product List Door sensor main body 1pc Door sensor deputy body 1pc Battery 2pcs Screw 4pcs Screw stopper 4pcs Sticker 2pcs Instruction manual 1pc Disassemble button Door sensor deputy body USB USB interface tamper alarm indicator light The code button Battery Sticker Screw stopper Screw Z-Wave Network Inclusion/Exclusion/Reset Remove the sensor casing, there is one button on the top side of PCB board, it can be executed inclusion, exclusion and reset from Z-Wave network. Blue led will blink with 1s interval inclusion successful. until Blue led will blink with 0.5s interval exclusion successful. until Add Remove Factory Reset Product Test Mode Send NIF 1 Power up the device. 2 Set Z-Wave Controller into inclusion mode 3 Press and hold the button for 5s until white led lights is on, then release the button before led turn off. 1 Power up the device. 2 Set Z-Wave Controller into exclusion mode 3 Press and hold the button for 5s until white led lights is on, then release the button before led turn off. 1 Power up the device. 2 Press and hold the button for 10s until pink led lights is on, then release the button before led turn off. 1 Press and hold the button. 2 Power on the device, device will enter into factory product test mode with white light blink one time. Press and hold the button for 5s until white led lights is on, then release the button before led turn off. Notice 1: When device enters into inclusion mode, the device all functionality will be useless. The inclusion mode will be timeout after 30s, user can implement step 3 to terminate inclusion mode. Notice 2: Factory Reset will clear the device all Z-Wave Network data (include home id, node id, etc) saved in memory, and restore all configuration parameters to factory default. Please use this procedure only when the network primary controller is missing or otherwise inoperable. Notice 3: NIF Node Information Installation Steps Door sensor Installation Battery Installation Door Sensor Installation Option One Disassemble the door sensor main body and take out battery, fix it on the door with screws. Disassemble the door sensor deputy body and fix it on the corresponding door frame position Option Two Put the sticker on the bottom of door sensor to fix it on the wall NOTE When installing the door sensor, door sensor deputy body must be installed on the bulge side of the door sensor main body. Battery Installation l D i s a s s e m b e f r o m h e r e Install battery Disassemble the door sensor Tips When the door is closed, and the distance between the main body and the deputy is less than 2cm, the Z-
Assemble the door main body sensor main body wave main controller displays the door is closed perfectly. When the door is opened, the distance between the main body and the deputy body is more than 2cm, LED light flash and door sensor sends messages to the Z-wave main controller, the Z-wave main controller displays the door is open and alarms. Valid distance of door sensor is 2cm, so when install, please pay attention to the trigger surface, it is triggered by point to point. Make sure of that door sensor is in the Z-wave network. Association The device supports 2 association groups, and each group supports max 5 associated nodes. Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device through lifeline. Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a door/window opened or closed event. The Command Class supported by each association group is shown in the table below:
Group 1 (Lifeline) Command Class COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_BATTERY COMMAND_CLASS_INDICATOR COMMAND_CLASS_DEVICE_RESET_LOCALLY Event NOTIFICATION_REPORT SENSOR_MULTILEVEL_REPORT SENSOR_BINARY_REPORT BATTERY_REPORT INDICATOR_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 2 (Control) COMMAND_CLASS_BASIC BASIC_SET Notice 1: {COMMAND_CLASS_BATTERY, BATTERY_REPORT} is valid only when included with LPM. Please see Page 9 for detail. Z-Wave Message Report Once the device detects a door/window opened or closed event, it will report the event to the controller. In default, device will use COMMAND_CLASS_NOTIFICATION to represent the door/window event. User can also enable COMMAND_CLASS_SENSOR_BINARY report by setting the Configuration No.8 to 1. Door/Window Report When device detects a door/window opened or closed event, it will automatically send the notification report to nodes associated in lifeline. Command Class COMMAND_CLASS_NOTIFICATION Command Type NOTIFICATION_REPORT ACCESS_CONTROL (0x06) Event WINDOW_OR_DOOR_IS_OPENED (0x16) WINDOW_OR_DOOR_IS_CLOSED(0x17) Command Class COMMAND_CLASS_SENSOR_BINARY Command Type Event SENSOR_BINARY_REPORT DOOR/WINDOW (0x0A) OPENED (0xFF) / CLOSED (0x00) Tamper Report When device detects the cover is removed event, it will automatically send the notification report to nodes associated in lifeline. Command Class COMMAND_CLASS_NOTIFICATION Command NOTIFICATION_REPORT NOTIFICATION_TYPE_HOME_SECURITY (0x07) NOTIFICATION_EVENT_HOME_SECURITY_TAMPERING_COVERING_REMOVED (0x03) NOTIFICATION_EVENT_HOME_SECURITY_NO_EVENT (0x00) Type Event Command Class COMMAND_CLASS_SENSOR_BINARY Command SENSOR_BINARY_REPORT Type TAMPER (0x08) COVER_REMOVED (0xFF) / COVER_CLOSED (0x00) Event Command Class Sensor Multilevel Temperature Sensor When the ambient temperature differential over 1.0 or 1.0 degree F(in default, and decides by Configuration No. 4), the device will unsolicited to send a SENSOR_MULTILEVEL_REPORT to nodes which associated in lifeline. Command Class Command Type Scale Humidity Sensor COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT Air Temperature 0.1 Degree Celsius / Fahrenheit(US) When the relative humidity differential over 1.0%RH (in default, and decides by Configuration No. 5), the device will unsolicited to send a SENSOR_MULTILEVEL_REPORT to nodes which associated in lifeline. Command Class Command Type Scale COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT Humidity 0.1% RH Command Class Configuration The device supports the controller to configure parameters of the device through Configuration Command Class, and the device has 9 parameters available for users to set according to their different needs:
1) Led Indicated Disable This configuration sets to 0 will disable the Led indicating when device detects a door/window opened or closed event. Parameter Number Size (Byte) 1 1 Available Settings Default value 0, 1 1 This configuration sets to 1 will enable SENSOR_BINARY_REPORT when device detects a 2) Binary Sensor Report Enable door/window opened or closed event. Parameter Number Size (Byte) 2 1 3) Temperature Offset Value Available Settings Default value 0 , 1 0 The current measuring temperature value can be add and minus a value by this setting. Temperature Offset Value =
[Value] 0.1 Degree Celsius / Fahrenheit
(US). Parameter Number Size (Byte) 3 1 Available Settings
-120 ~ 120 Default value 0 4) Humidity Offset Value The current measuring humidity value can be add and minus a value by this setting. Humidity Offset Value = [Value] 0.1 RH%. Parameter Number Size (Byte) 4 1 Available Settings
-120 ~ 120 Default value 0 5) Temperature D-Value Setting This configuration sets the changed value of the temperature. When the difference from the last report exceeds this setting value, the device will report current temperature value to Z-Wave Hubs. The D-Value = [Value] 0.1 Degree Celsius / Fahrenheit (US). Available Settings Parameter Number Size (Byte) 5 0 ~ 100 1 Default value 10 6) Humidity D-Value Setting This configuration sets the changed value of the humidity. When the difference from the last report exceeds this setting value, the device will report current humidity value to Z-Wave Hubs. The D- Value =
[Value] 0.1 RH%. Parameter Number Size (Byte) 6 1 Available Settings 0 ~ 100 Default value (min) 20 7) Basic Set Value This configuration sets the level for device sending BASIC_SET to nodes that associated in group 2 when device detects a door/window opened event.
[0] Off, BASIC_SET = 0x00, all nodes associated in group 2 will be off. [1 99]
On. BASIC_SET = [Setting Value].
[100] On, BASIC_SET = 0xFF. Parameter Number Size (Byte) 7 Available Settings Default value 0 ~ 100 100 1 8) Basic Set Off Delay Time This configuration sets the time delay for device sending BASIC_SET = 0x00 to nodes that associated in group 2 when device detects a door/window closed event.
[0] No time delay.
[1 Parameter Number Size (Byte) 8 Unit:
Available Settings Default value 0 ~ 30000 Second. 30000]
count. delay Time 2 0 9) Sensor Measuring Interval This parameter is configured the time interval for sensor measuring interval time. This value is larger, the sensor values updates slowly. 0 Sensor Measuring Disable. Unit: Second. Parameter Number Size (Byte) 9 2 Available Settings 0 ~ 30000 Default value 180 Wakeup Command Class The device stays in sleep status for the majority of time in order to conserve battery life. The minimum wakeup interval is 20s The maximum wakeup interval is 86400s (24 Hours) Allowable min step among each wakeup interval is 10 seconds, such as 1860s, 1870s,1880s Note: The default value is 8 hours with factory default. This value is greater, the battery life is longer. Battery Command Class The users can also enquire the battery status of the device by sending BATTERY_GET command. Once the device receivers the command, it will return BATTERY_REPORT command. The device will send BATTERY_LEVEL = 0xFF command to the Z-Wave Controller to inform that the device is in dead battery status, otherwise BATTERY_LEVEL value range is 0% to 100%. Command Class Basic The COMMAND_CLASS_BASIC is realized to control the devices associated in group 2 in this device. When device detects a Door/Window opened event occurred, it will send a BASIC_SET = [Value] command to control the devices in group 2. And it will send a BASIC_SET = 0x00 command to control the devices in group 2 after the Door/Window is closed. The [Value] is set by configuration No.7. SmartStart SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. This device supports SmartStart function. QR code printed by laser can be found on surface of product and the outside of packing box. And the full DSK code is printed can be found on the packing box. The device will enter SmartStart if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then 2nd SmartStart time delay approximately 16s 3rd SmartStart time delay approximately 32s 4th SmartStart time delay approximately 64s 5th SmartStart time delay approximately 128s 6th SmartStart time delay approximately 256s 7th SmartStart time delay approximately 512s Afterwards, the Smartstart mode will be auto running with 512 second interval until device is included successfully or battery run down. Led Action Indicator Led Color Red Pink Green White Cyan Blue Yellow Action Light On 1s When Power On Blink One Time Fast Blinks Light On 2s Light On 1s When Power On Blink One Time Light On 2s Blink One Time Blink with 1s Interval Blink with 500ms Interval Blink with 500ms Interval Light On Always Description Not Add in Z-Wave Network Door/Window is Opened Cover is Removed Press And Hold Button 10s, Off at 12th Second Add in Z-Wave in Network Already Door/Window is Closed Press And Hold Button 5s, Off at 7th Second Cover is Closed Add to Z-Wave Network Remove from Z-Wave Network OTA is Running Button Pressed and Held Time Large Than 12s. Security Network The device supports the security function with S2 encrypted communication. The device will auto switch to the security mode when the device included with a security controller. In the security mode, the follow commands must use security and security_2 command class wrapped to communicate, otherwise the device will not response any commands. Security Keys This device supports security levels are listed in below table:
Support (Yes/No) Security Levels SECURITY_KEY_S0 Yes SECURITY_KEY_S2_UNAUTHENTICATED Yes Yes SECURITY_KEY_S2_AUTHENTICATED SECURITY_KEY_S2_ACCESS No All Supports Command Class This device supports 2 role type: AOS(Always On Slave) and LPM(Low Power Mode). Which role type is valid decided by which power (Battery or DC Power) is supplied when include. The role type is AOS if both battery and DC power supply. The role type is LPM only if battery supply. When device is included with AOS, it also can make a repeater role. Command List When LPM Included Command Class Version Not Non-secure Included Included S0 Included S2 Included Non-Secure Secure Non-Secure Secure COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_VERSION COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_BATTERY COMMAND_CLASS_WAKEUP 2 1 1 2 3 1 2 3 1 2 1 1 2 Command List When AOS Included Command Class Version Not Non-secure Included Included S0 Included S2 Included Non-Secure Secure Non-Secure Secure COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_INDICATOR COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_VERSION COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_MULTILEVEL 11 COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_INDICATOR COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD 8 11 2 3 4 1 5 2 1 1 2 3 1 2 3 1 2 1 8 2 3 4 1 5