Specifications:
The following specifications apply to the UR1H bodypack only. UR1H UR1H Bodypack Transmitter Addendum Features High RF power (250 mW) Same audio performance as UR1 Operates with alkaline or lithium batteries Rapid, two-way infrared (IR) data transmission External DC power connection Optional remote mount antenna Belt clip Warning: The UR1H belt clip must be installed as shown to ensure compliance with FCC RF exposure guidelines for safe use. Safety Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment is in direct contact with the body of the user under normal operating conditions. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For body-worn operation, the UR1H has been tested and meets the guidelines for safe use when used properly with the belt clip supplied or designated by Shure for use with this product. For safe use, do not remove or alter the position at the belt clip other than as instructed. UR1H Transmitter Audio Input Connector:
Input Configuration:
Actual Impedance:
Maximum Input Level:
(1 kHz, 1% THD) TA4M Connector Pin Assignments:
4-Pin male mini connector (TA4M) Unbalanced, active
>1 M
+10 dBu (sensitivity 0 dB) +20 dBu
(sensitivity 10 dB) Pin 1: Ground Pin 2: +5 VDC bias Pin 3: Audio Pin 4: Tied through active load (on main board) to Ground
(On instrument adapter cable, Pin 4 floats) REPLACEMENT PARTS AND ACCESSORIES Furnished Accessories Antenna, 518-578 MHz . UA710 Antenna, 578-698 MHz . UA720 Antenna, 740-865 MHz . UA730 Threaded Locking Adaptor TA4F . WA340 Optional Accessories Bodypack Pouch (Black) . WA580B Bodypack Pouch (White) . WA580W AC to DC Power Supply . PS22 Antenna Accessories Note: SMA to adaptor (UA910) is required to connect the following antenna accessories:
UA740 UA860SWB Antenna, 944-952 MHz Passive Directional Wideband Antenna
(470-1100 MHz) UA802 2 ft. Coaxial Antenna Cable, BNC-BNC (RG58C/U) UA806 6 ft. Coaxial Antenna Cable, BNC-BNC (RG58C/U) UA825 25 ft. Coaxial Antenna Cable, BNC-BNC (RG8X/U) 50 ft. Coaxial Antenna Cable, BNC-BNC (RG8X/U) UA850 100 ft. Coaxial Antenna Cable, BNC-BNC (RG213/U) UA8100 SMA to BNC Adaptor UA910 Printed in U.S.A. Band H4, H4E J5 J5E L3E, L3 Q5 R9 X1 Frequency Range Range 518-578 MHz 578-608, 614-638 MHz 578-638 MHz 638-698 MHz 740-814 MHz 790-862 MHz 944-952 MHz RF Carrier Frequency Range 518-862 MHz, depending on region RF Output Power 250 mW (24 dBm) across all tunable frequencies, maximum variation of -1.5 dB Power Requirements Two 1.5V AA batteries or 9 - 20 VDC, Shure PS22 adaptor recommended Plug size: 1.7 mm x 4.0 mm (.067 in. x .159 in) NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device when used with PS22, pursuant to Part 15 of the FCC Rules. Current Drain: 350 mA maximum at the battery terminals with 3 VDC applied Battery Life (Typical): 3 hours, with 1.5V AA alkaline batteries 7 to 9 hours, with AA lithium primary batteries Overall Dimensions UR1H: 98 mm L x 60 mm W x 17 mm D
(3.84 x 2.38 x 0.66 in.) Net Weight 97 g (3.4 oz.) without batteries UR1H Transmitter RF Output Connector:
Actual Impedance:
Pin Assignments:
27A11915 (Rev. 2) 2008 Shure Incorporated SMA 50 Shell = Ground Center = Signal Certification UR1H meets the essential requirements of the European R&TTE Directive 99/5/EC (ETSI EN 300 422 Parts 1 & 2. Note: 250 mW RF output power, EN 300 454 Parts 1 & 2, EN 301 489 Parts 1 & 9) and is eligible to carry the CE marking. Certified under FCC Parts 74 (FCC ID: DD4UR1HA, DD4UR1HB, DD4UR1HC, DD4UR1HF). Certified by IC in Canada under RSS-123 and RSS-102
(IC: 616A-UR1HA, 616A-UR1HB, 616A-UR1HC). The EU Declaration of Conformity can be obtained from Shure Inc. or any of its European representatives. For contact information please visit www.shure.com LICENSING INFORMATION:
Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the users responsibility, and licensability depends on the users classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies. Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance FCC and IC Radiation Exposure Statement for Mobile Devices (when used with the UA860SWB) This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunc-
tion with any other antenna or transmitter. 2