all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
FCC information | Users Manual | 52.66 KiB | March 11 2005 | |||
1 |
|
User manual | Users Manual | 3.92 MiB | March 11 2005 | |||
1 | Operational Description | March 11 2005 | ||||||
1 | Cover Letter(s) | March 11 2005 | ||||||
1 | Cover Letter(s) | March 11 2005 | ||||||
1 | Cover Letter(s) | March 11 2005 | ||||||
1 | External Photos | March 11 2005 | ||||||
1 | External Photos | March 11 2005 | ||||||
1 | Internal Photos | March 11 2005 | ||||||
1 | ID Label/Location Info | March 11 2005 | ||||||
1 | ID Label/Location Info | March 11 2005 | ||||||
1 | RF Exposure Info | March 11 2005 | ||||||
1 | Test Report | March 11 2005 | ||||||
1 | Test Setup Photos | March 11 2005 |
1 | FCC information | Users Manual | 52.66 KiB | March 11 2005 |
RF660R reader 5.8 Certificates and approvals 5.8 Certificates and approvals 5.8.1 FCC information Siemens SIMATIC RF660R FCC ID: NXW-RF660 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 5.8.2 Compliance distance for RF Exposure The Transmitter is within the Health Canada and FCC limits for General Population/Uncontrolled Exposure to electromagnetic waves at a minimum operating distance of 23 cm. The installation design shall thus be such as to maintain a minimum distance of 23 cm between the antennas and users or other persons. RF600 5-18 System Manual, 09/2005 Edition, 31069 D0171-U001-A0-7618, Appendix EMC RF600 A.1 Certificates and approvals Federal Communications | This equipment has been tested and found to comply with the limits for a Commission Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations. Modifications Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Conditions of Operations | This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Radio Frequency Interference Statement CANADA Canadian Notice This Class B digital apparatus complies with Canadian ICES-003 Avis Canadien Cet appareil numrique de la classe b est conforme a la norme NMB-003 du Canada. AUSTRALIA This product meets the requirements of the AS/NZS 3548 Norm. System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, A-3
1 | User manual | Users Manual | 3.92 MiB | March 11 2005 |
SIMATIC RF600 RFID systems RF600 System Manual Introduction Safety Information System overview RF600 system planning RF660R reader Antennas Transponder/tags Accessories Appendix 1 2 3 4 5 6 7 8 A 09/2005 Edition, J31069 D0171-U001-A0-7618 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. Danger indicates that death or severe personal injury will result if proper precautions are not taken. Warning indicates that death or severe personal injury may result if proper precautions are not taken. Caution with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. Caution without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. Notice indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Prescribed Usage Note the following:
Warning This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90437 NRNBERG GERMANY Order No.:
Edition 09/2005 Copyright Siemens AG 2005. Technical data subject to change 2 3 4 5 Table of contents 1 Introduction............................................................................................................................................. 1-1 1.1 Preface....................................................................................................................................... 1-1 1.2 Navigating in the system manual............................................................................................... 1-3 Safety Information................................................................................................................................... 2-1 2.1 General safety instructions ........................................................................................................ 2-1 System overview..................................................................................................................................... 3-1 3.1 RF System SIMATIC RF600...................................................................................................... 3-1 3.1.1 Application areas of RF600........................................................................................................ 3-2 3.1.2 Features..................................................................................................................................... 3-3 RF600 system planning .......................................................................................................................... 4-1 Overview .................................................................................................................................... 4-1 4.1 4.2 Antenna configurations .............................................................................................................. 4-2 Antenna configuration example ................................................................................................. 4-2 4.2.1 Possibilities and application areas for antenna configurations.................................................. 4-3 4.2.2 4.2.3 Tag orientation in space............................................................................................................. 4-6 4.2.4 Specified minimum and maximum spacing of antennas ........................................................... 4-7 Mutual interference of readers (antennas)................................................................................. 4-9 4.2.5 4.2.6 Reading range ......................................................................................................................... 4-10 Increasing the probability of identification for tags - Antenna switching .................................. 4-11 4.2.7 4.3 Environmental conditions for transponders ............................................................................. 4-12 Basic rules................................................................................................................................ 4-12 4.3.1 The response of electromagnetic waves in the UHF band...................................................... 4-13 4.4 4.4.1 The effect of reflections and interference ................................................................................ 4-13 4.4.2 Influence of metals................................................................................................................... 4-14 Influence of liquids and non-metallic substances .................................................................... 4-15 4.4.3 Regulations applicable to frequency bands............................................................................. 4-16 4.5 4.5.1 Regulations for UHF frequency bands in Europe .................................................................... 4-16 4.5.2 Regulations for UHF frequency bands in the USA .................................................................. 4-18 4.6 Guidelines for electromagnetic compatibility (EMC)................................................................ 4-19 4.6.1 Overview .................................................................................................................................. 4-19 4.6.2 What does EMC mean?........................................................................................................... 4-20 4.6.3 Basic rules................................................................................................................................ 4-20 Propagation of electromagnetic interference........................................................................... 4-23 4.6.4 4.6.5 Prevention of interference sources .......................................................................................... 4-27 4.6.6 Equipotential bonding .............................................................................................................. 4-28 4.6.7 Cable shielding......................................................................................................................... 4-29 RF660R reader....................................................................................................................................... 5-1 Description ................................................................................................................................. 5-1 5.1 5.1.1 Ordering data ............................................................................................................................. 5-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, iii Table of contents Design of the RF660R reader .................................................................................................... 5-3 5.1.2 Status displays ........................................................................................................................... 5-4 5.1.3 Pin assignment of the serial interfaces ...................................................................................... 5-5 5.1.4 Pin assignment and connections of the digital I/O interface...................................................... 5-6 5.1.5 Power supply.............................................................................................................................. 5-8 5.1.6 Grounding connection................................................................................................................ 5-9 5.1.7 5-10 5.2 Installation /Mounting ............................................................................................................... 5-10 5.3 Mounting/Installation ................................................................................................................ 5-10 5.3.1 Configuration/integration.......................................................................................................... 5-10 5.4 Configuration............................................................................................................................ 5-10 5.4.1 Transmission protocols ............................................................................................................ 5-12 5.4.2 Maintenance and service ......................................................................................................... 5-13 5.5 Technical specifications ........................................................................................................... 5-14 5.6 Technical specifications of RF660R......................................................................................... 5-14 5.6.1 Dimension drawings................................................................................................................. 5-17 5.7 Dimension drawings................................................................................................................. 5-17 5.7.1 Certificates and approvals........................................................................................................ 5-18 5.8 FCC information ....................................................................................................................... 5-18 5.8.1 5.8.2 Compliance distance for RF Exposure .................................................................................... 5-18 Antennas ................................................................................................................................................ 6-1 RF660A antenna........................................................................................................................ 6-1 6.1 RF660A description.................................................................................................................... 6-1 6.1.1 6.1.2 Application Planning................................................................................................................... 6-4 6.1.3 Installation /Mounting ................................................................................................................. 6-6 6.1.4 Connecting an antenna to a reader ........................................................................................... 6-9 6.1.5 Technical specifications ........................................................................................................... 6-10 Transponder/tags.................................................................................................................................... 7-1 7.1 Mode of operation of transponders............................................................................................ 7-1 Transponder classes and generations....................................................................................... 7-2 7.2 7.3 Electronic Product Code (EPC) ................................................................................................. 7-4 Accessories ............................................................................................................................................ 8-1 Wide-range power supply unit for SIMATIC RF systems .......................................................... 8-2 8.1 8.1.1 Features ..................................................................................................................................... 8-2 8.1.2 Scope of supply.......................................................................................................................... 8-4 8.1.3 Ordering data ............................................................................................................................. 8-4 Safety Information...................................................................................................................... 8-4 8.1.4 Connecting ................................................................................................................................. 8-5 8.1.5 8.1.6 Technical specifications ............................................................................................................. 8-6 8.1.7 Modification possibilities............................................................................................................. 8-8 Pin assignment of DC outputs and mains connection ............................................................... 8-8 8.1.8 Dimension drawing..................................................................................................................... 8-9 8.1.9 Certificates and approvals..........................................................................................................A-1 A.1 A.2 Service and support ...................................................................................................................A-4 Contact partners.........................................................................................................................A-5 A.3 A.4 Training ......................................................................................................................................A-5 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6 7 8 iv Table of contents RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, v Introduction 1.1 Preface Purpose of this document 1 This system manual contains the information needed to plan and configure the system. It is intended both for programming and testing/debugging personnel who commission the system themselves and connect it with other units (automation systems, further programming devices), as well as for service and maintenance personnel who install expansions or carry out fault/error analyses. Where this documentation is valid This documentation is valid for all supplied variations of the SIMATIC RF600 system and describes the state of delivery as of September 2005. The following terms/abbreviations are used synonymously in this document:
Reader, read/write device, write/read device Tag, transponder, mobile data memory, data carrier, SmartLabel Communication module, interface module Conventions History Edition 09/2005 Remarks First Edition Declaration of conformity The EC declaration of conformity and the corresponding documentation are made available to authorities in accordance with EC directives. Your sales representative can provide these on request. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 1-1 Introduction 1.1 Preface Observance of installation guidelines The installation guidelines and safety instructions given in this documentation must be followed during commissioning and operation. 1-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 1.2 Navigating in the system manual Introduction 1.2 Navigating in the system manual Structure of contents Table of Contents Introduction Safety Information System overview RFID system planning Readers Antennas Transponders Appendix List of abbreviations Contents Organization of the documentation, including the index of pages and chapters Purpose, layout and description of the important topics. Refers to all the valid technical safety aspects which have to be adhered to while installing, commissioning and operating the product/system and with reference to statutory regulations. Overview of all RF identification systems, system overview of SIMATIC RF600 Information about possible applications of SIMATIC RF600, support for application planning, tools for finding suitable SIMATIC RF600 components. Description of readers which can be used for SIMATIC RF600 Description of antennas which can be used for SIMATIC RF600 Description of transponders which can be used for SIMATIC RF600 Service and support, contact partners, training centers List of all abbreviations used in the document RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 1-3 Introduction 1.2 Navigating in the system manual 1-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Safety Information 2.1 General safety instructions 2 Repairs Caution Please observe the safety instructions on the back cover of this documentation. SIMATIC RFID products comply with the salient safety specifications to IEC, EN, UL and CSA. If you have questions about the admissibility of the installation in the designated environment, please contact your service representative. Caution Alterations to the devices are not permitted. Failure to observe this requirement shall constitute a revocation of the radio equipment approval, CE approval and manufacturer's warranty. Repairs may only be carried out by authorized qualified personnel. Warning Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or risk of personal injury to the user. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 2-1 Safety Information 2.1 General safety instructions System expansion Only install system expansion devices designed for this device. If you install other upgrades, you may damage the system or violate the safety requirements and regulations for radio frequency interference suppression. Contact your technical support team or your sales outlet to find out which system upgrades are suitable for installation. Caution If you cause system defects by installing or exchanging system expansion devices, the warranty becomes void. 2-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, System overview 3.1 RF System SIMATIC RF600 3 SIMATIC RF600 is an identification system that operates in the UHF range. UHF technology supports large write/read distances with passive tags. The SIMATIC RF660-R read/write devices (readers), fitted for example on the gate of a warehouse, automatically record every movement of goods, and signal these to the host systems. The data are filtered and compressed there by data management software in order, for example, to generate the receiving department transaction for the ERP system. At the same time, the delivery can be automatically checked for correctness and completeness prior to storage by means of the electronic delivery list.
Figure 3-1 System overview of SIMATIC RF600 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
3-1 System overview 3.1 RF System SIMATIC RF600 3.1.1 Application areas of RF600 RFID (radio frequency identification) permits interruption-free tracking and documentation of all delivered, stocked and shipped goods in the incoming goods, warehouse, production logistics and distribution departments. A small data medium - referred to as SmartLabel or tag - is adhered to every item, package or palette, and contains all important information. The data medium receives the power it requires via an antenna which is also used for data transmission. Equipped with a rugged casing to the high IP 65 degree of protection and suitable for use over a wide range of temperatures, the reader is also a match for the demands of harsh industrial conditions in, for example, warehouses or on loading ramps. 3-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 3.1.2 Features System overview 3.1 RF System SIMATIC RF600 The RF600 identification system has the following performance features:
RFID system RF600 Type Transmission frequency Read/write distance Data carrier/tags Memory Type Standards Software Data Manager Configuration software System requirements Contactless RFID (Radio Frequency IDentification) system in the UHF band 865-868 MHz (Europe) 902-928 MHz (USA) Europe: < 3.5 m USA: < 4 m Up to 2048 bits Smart Labels Container tag (available soon) Heat-resistant data medium (available soon) EPCglobal Class 1, Gen 2 ISO 18000-6B Interfacing to IT systems PC software for Configuration and diagnostics PC software for parameterizing the RF660R reader Windows XP with Net Framework 1.1 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 3-3 System overview 3.1 RF System SIMATIC RF600 3-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.1 Overview You should observe the following criteria for implementation planning:
Antenna configurations Environmental conditions for transponders The response of electromagnetic waves in the UHF band EMC directives 4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-1 RF600 system planning 4.2 Antenna configurations 4.2 Antenna configurations 4.2.1 Antenna configuration example The following diagram shows an example of a portal configuration. The antenna are positioned at the height at which the tags are expected which are to be identified. The maximum width of the portal that is recommended for reliable operation is 4 m. The diagram shows a configuration with two antennas. Up to four antennas can be used depending on the local conditions.
Figure 4-1 Typical gate configuration
4-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.2 Antenna configurations 4.2.2 Possibilities and application areas for antenna configurations Some basic antenna configurations and possible fields of application are shown below. Antenna configuration 1:
Description/ application areas This arrangement of antennas is appropriate when the tags to be read are only located on one side of the items to be identified, e.g. when palettes are to be identified on which the tags to be read must be on a prespecified side. Tag
Antenna configuration 2:
Description/ application areas Preferred application: In the identification of goods in loading portals. The tag is located in the field of radiation of two antennas; for reliable tag reading, the height of the tag above floor level must therefore be known with reasonable accuracy. Tag RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-3 RF600 system planning 4.2 Antenna configurations Antenna configuration 3:
Description/ application areas Preferred application: In the identification of goods in loading portals. Similar to configuration 2, but with additional reading reliability when the tag is at an angle to the vertical. Tag
Antenna configuration 4:
Description/ application areas Preferred application: In the identification of goods in loading portals. The tag is located in the field of radiation of all four antennas, so the tag position can vary more than in configuration 2 for reliable tag identification. Tag 4-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Antenna configuration 5:
Antenna configuration 6:
RF600 system planning 4.2 Antenna configurations Description/ application areas Preferred application: In the identification of goods in loading portals. Similar to configuration 4, but the reliability of tag identification is improved as a result of the four antennas at separate locations, so the tag position is not critical. Tag Description/ application areas This tunnel configuration is suitable for conveyor belt applications. The goods with the tags to be read are moving forwards on a conveyor belt but the alignment of the tags relative to the antennas is not clearly defined. One of the antenna is located on the floor and radiates vertically upwards in the direction of the conveyor belt. A relatively high reading reliability is achieved due to the use of four antennas. Tag
RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-5 RF600 system planning 4.2 Antenna configurations 4.2.3 Tag orientation in space The alignment of the tag antenna to the antenna of the reader affects the reading range. For maximum performance and to achieve the maximum reading range, the tag antenna should therefore be aligned in parallel with the reader antenna:
Parallel tag alignment Large reading range Maximum probability of identification of tags. Perpendicular tag alignment Minimal reading range Minimum probability of identification of tags. 4-6 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.2 Antenna configurations 4.2.4 Specified minimum and maximum spacing of antennas Specified minimum spacing of antennas The following diagram shows the specified minimum and maximum spacings for mounting antennas:
A minimum spacing of 50 cm is necessary between the antenna and liquids or metals. The distance between the antenna and the floor should also be at least 50 cm.
Figure 4-2 Distance to the environment The distance between two antennas mounted alongside each other or one above the other should be at least 20 to 50 cm. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-7 RF600 system planning 4.2 Antenna configurations
Figure 4-3 Antennas mounted adjacently horizontally or vertically For a portal configuration, the distance between two antennas that are connected to the same reader is up to 3.5 m (in Europe) or 4 m (in the USA).
Figure 4-4 Portal configuration 4-8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.2 Antenna configurations 4.2.5 Mutual interference of readers (antennas) Using more than one reader When several RFID readers are used, there is a danger that RFID tags can also be read by other readers. It must be ensured that the tag can only be identified by the appropriate reader. Technical faults between readers can then only occur when they transmit on the same channel, i.e. in the same frequency range of a frequency band. To prevent this, the RF660R reader uses the "Listen before talk" technique in Europe or frequency hopping between many different channels in the USA. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-9 RF600 system planning 4.2 Antenna configurations 4.2.6 Reading range The reading range between the reader (antenna) and the transponder is affected by the following factors:
The reading range depends on Transmit power of the reader Tag size and type Absorption factor of the materials Antenna amplification Production quality of the tag Reflection characteristics of the environment
. Description The higher the transmit power of the reader, the larger the reading range. The larger the tag antenna, the larger the power input area and therefore the larger the reading range. The higher the absorption of the surrounding material, the smaller the reading range. The bigger the antenna amplification, the larger the reading range. The better the tag has been matched to the operating frequencies during manufacturing, the greater the reading range In a multiple-reflection environment, the reading range can be significantly higher than in a low-reflection environment. 4-10 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.2 Antenna configurations 4.2.7 Increasing the probability of identification for tags - Antenna switching To achieve a high probability of reading tags, the antenna switching function has been implemented in the RF600R reader:
At a given time, the system transmits on one antenna and receives on the other antennas. As long as the antenna is receiving signals from further tags, the system continues to transmit on the same transmit antenna until all responding tags have been identified. Subsequently, or if no tags respond, the system activates another antenna as the transmit antenna. After all the antenna have transmitted at least once, or when the settling time is excessively long, the reader activates frequency hopping (in the USA) or channel selection
(in Europe). Cycle 2 Cycle 3
Cycle 1
Antenna 1 transmits Antenna 2 and 3 receive Antenna 2 transmits Antenna 1 and 3 receive Antenna 3 transmits Antenna 1 and 2 receive RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-11 RF600 system planning 4.3 Environmental conditions for transponders 4.3 Environmental conditions for transponders 4.3.1 Basic rules The transponder must not be placed directly on metal surfaces or on containers of liquid. For physical reasons, a minimum distance must be maintained between the tag antenna and conductive material. A minimum distance of 5 cm is recommended. The tag function is improved with greater distances (between 5 and 20 cm). The best performance is achieved when the tag is mounted on a non-conductive material such as plastic or wood. Exception:
Tags that are designed for direct mounting on metal. 4-12 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.4 The response of electromagnetic waves in the UHF band 4.4 The response of electromagnetic waves in the UHF band 4.4.1 The effect of reflections and interference Reflections and interference Electromagnetic waves in the UHF band behave and propagate in a similar manner to light waves, that is they are reflected from large objects such as ceilings, floors, walls and windows and interfere with each other. Due to the nature of electromagnetic waves, interference can lead to wave amplification which can produce an increased reading range. In the worst case, interference can also result in waves being extinguished which causes holes in reader coverage. Reflections can also be beneficial when they cause electromagnetic waves to be routed around objects to a certain extent (deflection). This can increase the reading probability. Due to these electromagnetic characteristics, it is extremely difficult in the multiple-reflection environment that is usually found in the real environment on site, to determine propagation paths and field strengths for a particular location. Reducing the effect of reflections/interference on tag identification Reducing the transmit power:
To reduce interference to a minimum, we recommend that the transmit power of the reader is reduced until it is sufficient for an identification rate of 100 %
Increasing the number of antennas to 3 or 4:
More antennas in a suitable antenna configuration can prevent gap in reader coverage RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-13 RF600 system planning 4.4 The response of electromagnetic waves in the UHF band 4.4.2 Influence of metals Metal can have an effect on the electromagnetic field depending on the arrangement or environment. The effect ranges from a hardly determinable influence through to total blocking of communication. The term metal in this context also includes metallized materials that are either coated with metal or shot through with metal to such an extent that UHF radiation cannot penetrate or only to a minimal extent. The effect of metal on the electromagnetic field can be prevented as follows:
Do not mount tags on metal Ensure there are no metallic objects at close range to the antenna Ensure there are no metallic objects in the propagation field of the antenna and transponder Tags mounted directly onto metal In general, tags must not be mounted directly onto metallic surfaces. Due to the nature of the magnetic field, a minimum distance must be maintained between the tag antenna and conductive materials. The minimum distance to metal must be greater than 5 cm. The larger the distance, the better the function of the transponder. Exception:
Tags that are designed for direct mounting on metal. 4-14 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.4 The response of electromagnetic waves in the UHF band 4.4.3 Influence of liquids and non-metallic substances Non-metallic substances can also affect the propagation of electromagnetic waves. When non-metallic substances or objects are located in the propagation field that can absorb UHF radiation, these can alter the antenna field depending on their size and distance and can even extinguish the field entirely. The high-frequency damping effect of water and materials with a water content, ice and carbon is high. Electromagnetic energy is partly reflected and absorbed. Liquids and petroleum-based oils have low HF damping. Electromagnetic waves penetrate the liquid and are only slightly weakened. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-15 RF600 system planning 4.5 Regulations applicable to frequency bands 4.5 Regulations applicable to frequency bands 4.5.1 Regulations for UHF frequency bands in Europe Regulations for frequency bands according to EN 302 208 ETSI (European Telecommunications Standards Institute) Specifications of European standard EN 302 208:
UHF band: 865 to 868 MHz Radiant power: max. 2 W (ERP) Channel bandwidth: 200 kHz Number of channels: 15 Listen before talk
4-16 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.5 Regulations applicable to frequency bands Channel assignment The UHF band from 865 to 868 MHz is subdivided into three sub bands:
Sub bands
Frequency range 865.0 to 865.5 MHz 865.6 to 867.6 MHz 867.6 to 868.0 MHz Output 0.1 W ERP 2,0 W ERP 0,5 W ERP
Listen before talk With this technique, the reader checks whether a channel is assigned before transmission to prevent collisions. The reader will only transmit when a channel is free. The reader can transmit for up to ?? seconds on this channel and must then pause for at least ?? seconds or jump immediately to an unassigned channel on which it can transmit for a further ??
seconds. Regulations for frequency bands according to EN 300 220 (short range device) For those countries in which the RFID directive according to EN 302 208 has not yet been implemented, this alternative exists which is based on the older "Short range device"
directive:
EN 300 220 (short range device) Frequency range Number of channels Transmit power Duty cycle (frequency assignment period) 865.6 to 868 MHz 12 Max. 0.5 W ERP 10 % (6 min./h) RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-17 RF600 system planning 4.5 Regulations applicable to frequency bands 4.5.2 Regulations for UHF frequency bands in the USA USA FCC (Federal Communications Commission) UHF band: 902 to 928 MHz Radiant power: max. 4 W (EIRP) Number of channels: 50 Frequency hopping
Frequency hopping This technique should prevent mutual interference between readers. The reader changes its transmission channel in a random or programmed sequence (FHSS - Frequency Hopping Spread Spectrum). The 50 available channels mean that the probability is low that two readers will be operating on the same frequency 4-18 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.1 Overview These EMC Guidelines answer the following questions:
Why are EMC guidelines necessary?
What types of external interference have an impact on the system?
How can interference be prevented?
How can interference be eliminated?
Which standards relate to EMC?
Examples of interference-free plant design The description is intended for "qualified personnel":
Project engineers and planners who plan system configurations with RFID modules and have to observe the necessary guidelines. Fitters and service engineers who install the connecting cables in accordance with this description or who can rectify defects in this area in the event of interference. Warning Failure to observe notices drawn to the reader's attention can result in dangerous conditions in the plant or the destruction of individual components or the entire plant. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-19 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.2 What does EMC mean?
Increasing switching rates The increasing use of electrical and electronic devices is accompanied by:
Higher component density More switched power electronics Lower power consumption of components due to steeper switching edges The higher the degree of automation, the greater the risk of interaction between devices. Electromagnetic compatibility (EMC) is the ability of an electrical or electronic device to operate satisfactorily in an electromagnetic environment without affecting or interfering with the environment over and above certain limits. EMC can be broken down into three different areas:
Intrinsic immunity to interference:
immunity to internal electrical disturbance Immunity to ambient interference:
immunity to external electromagnetic disturbance Degree of interference emission:
emission of interference and its effect on the electrical environment All three areas are considered when testing an electrical device. The RFID modules are tested for conformity with the limit values required by the CE and RTTE guidelines. Since the RFID modules are merely components of an overall system, and sources of interference can arise as a result of combining different components, certain guidelines have to be followed when setting up a plant. EMC measures usually consist of a complete package of measures, all of which need to be implemented in order to ensure that the plant is immune to interference. Note The plant manufacturer is responsible for the observance of the EMC guidelines; the plant operator is responsible for radio interference suppression in the overall plant. All measures taken when setting up the plant prevent expensive retrospective modifications and interference suppression measures. The salient national specifications and regulations must be observed. They are not covered in this document. 4.6.3 Basic rules It is often sufficient to follow a few elementary rules in order to ensure electromagnetic compatiblity (EMC). The following rules must be observed:
4-20 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Shielding by enclosure RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) Protect the device against external interference by installing it in a cabinet or housing. The housing or enclosure must be connected to the chassis ground. Use metal plates to shield the device against electromagnetic fields. Use metal connector housings to shield data conductors. Wide-area ground connection Bond all passive metal parts to chassis ground, ensuring large-area and low-HF-
impedance contact. Establish a large-area connection between the passive metal parts and the central grounding point. Don't forget to include the shielding bus in the chassis ground system. That means the actual shielding busbars must be connected to ground by large-area contact. Aluminium parts are not suitable for ground connections. Plan the cable installation Break the cabling down into cable groups and install these separately. Always route high-voltage and signal cables through separated ducts or in separate bundles. Feed the cabling into the cabinet from one side only and, if possible, on one level only. Route the signal cables as close as possible to chassis surfaces. Twist the feed and return conductors of separately installed cables. Cable routing of HF cables:
Avoid installing cables in parallel over long distances and maintain minimum distances between the cables (at least 25 cm) RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-21 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) Shielding for the cables Shield the data cables and connect the shield at both ends. Shield the analog cables and connect the shield at one end, e.g. on the drive unit. Always apply large-area connections between the cable shields and the shielding bus at the cabinet inlet and make the contact with clamps. Feed the connected shield through to the module without interruption. Use braided shields, not foil shields. Line and signal filter Use only line filters with metal housings Connect the filter housing to the cabinet chassis using a large-area low-HF-impedance connection. Never fix the filter housing to a painted surface. Fix the filter at the control cabinet inlet or in the direction of the source. 4-22 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.4 Propagation of electromagnetic interference Interference source Three components have to be present for interference to occur in a system:
Coupling path Interference sink
Figure 4-5 Propagation of interference If one of the components is missing, e.g. the coupling path between the interference source and the interference sink, the interference sink is unaffected, even if the interference source is transmitting a high level of noise. The EMC measures are applied to all three components, in order to prevent malfunctions due to interference. When setting up a plant, the manufacturer must take all possible measures in order to prevent the occurrence of interference sources:
Only devices fulfilling limit class A of VDE 0871 may be used in a plant. Interference suppression measures must be introduced on all interference-emitting devices. This includes all coils and windings. The design of the system must be such that mutual interference between individual components is precluded or kept as small as possible. Information and tips for plant design are given in the following sections. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-23 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) Interference sources In order to achieve a high level of electromagnetic compatibility and thus a very low level of disturbance in a plant, it is necessary to recognize the most frequent interference sources. These must then be eliminated by appropriate measures. Table 4-1 Interference sources: origin and effect Interference source Contactors, electronic valves Electrical motor Electric welding device Interference results from Contacts Coils Collector Winding Contacts Transformer Power supply unit, switched-
mode High-frequency appliances Transmitter
(e.g. service radio) Ground or reference potential difference Operator Power cable Circuit Circuit Antenna Static charge Current flow High-voltage cable Voltage difference Effect on the interference sink System disturbances Magnetic field Electrical field Magnetic field Electrical field Magnetic field, system disturbance, transient currents Electrical and magnetic field, system disturbance Electromagnetic field Electromagnetic field Electrical discharge currents, electrical field Electrical and magnetic field, system disturbance Electrical field Voltage difference Transient currents 4-24 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) What interference can affect RFID?
Interference source Switched-mode power supply Interference emitted from the Cause Interference injected through the cables connected in series HF interference over the antennas current infeed Cable is inadequately shielded The reader is not connected to ground. caused by another reader External sources of interference that use or transmit on the same frequency range. Remedy Replace the power supply Better cable shielding Ground the reader Change the operating mode of the reader. Position the antennas further apart. Erect suitable damping materials between the antennas. Reduce the power of the readers. Use the frequency hopping technique RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-25 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) Coupling paths A coupling path has to be present before the disturbance emitted by the interference source can affect the system. There are four ways in which interference can be coupled in:
Figure 4-6 Ways in which interference can be coupled in When RFID modules are used, different components in the overall system can act as a coupling path:
Table 4-2 Causes of coupling paths Coupling path Conductors and cables Control cabinet or housing Invoked by Incorrect or inappropriate installation Missing or incorrectly connected shield Inappropriate physical arrangement of cables Missing or incorrectly wired equalizing conductor Missing or incorrect earthing Inappropriate physical arrangement Components not mounted securely Unfavorable cabinet configuration 4-26 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.5 Prevention of interference sources A high level of immunity to interference can be achieved by avoiding interference sources. All switched inductances are a frequent source of interference in plants. Suppression of inductance Relays, contactors, etc. generate interference voltages and must therefore be suppressed using one of the circuits below. Even with small relays, interference voltages of up to 800 V occur on 24 V coils, and interference voltages of several kV occur on 230 V coils when the coil is switched. The use of freewheeling diodes or RC circuits prevents interference voltages and thus stray interference on conductors installed parallel to the coil conductor.
Figure 4-7 Suppression of inductance Note All coils in the cabinet should be suppressed. The valves and motor brakes are frequently forgotten. Fluorescent lamps in the control cabinet should be tested in particular. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-27 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.6 Equipotential bonding Potential differences between different parts of a plant can arise due to the different design of the plant components and different voltage levels. If the plant components are connected across signal cables, transient currents flow across the signal cables. These transient currents can corrupt the signals. Proper equipotential bonding is thus essential. The equipotential bonding conductor must have a sufficiently large cross section (at least 10 mm2). The distance between the signal cable and the associated equipotential bonding conductor must be as small as possible (antenna effect). A fine-strand conductor must be used (better high-frequency conductivity). When connecting the equipotential bonding conductors to the centralized equipotential bonding strip, the power components and non-power components must be combined.
Figure 4-8 Equipotential bonding The better the equipotential bonding in a plant, the smaller the chance of interference due to fluctuations in potential. Equipotential bonding should not be confused with protective earthing of a plant. Protective earthing prevents the occurrence of excessive contact voltages in the event of device faults. 4-28 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) 4.6.7 Cable shielding Signal cables must be shielded in order to prevent coupling of interference. The best shielding is achieved by installing the cables in steel tubes. However, this is only necessary if the signal cable is routed through an environment prone to particular interference. It is usually adequate to use cables with braided shields. In either case, however, correct connection is vital for effective shielding. Note An unconnected or incorrectly connected shield has no shielding effect. As a rule:
For analog signal cables, the shield should be connected at one end on the receiver side For digital signals, the shield should be connected to the enclosure at both ends Since interference signals are frequently within the HF range (> 10 kHz), a large-area HF-
proof shield contact is necessary Figure 4-9 Cable shielding The shielding bus should be connected to the control cabinet enclosure in a manner allowing good conductance (large-area contact) and must be situated as close as possible to the cable inlet. The cable insulation must be removed and the cable clamped to the shielding bus (high-frequency clamp) or secured using cable ties. Care should be taken to ensure that the connection allows good conductance. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 4-29 RF600 system planning 4.6 Guidelines for electromagnetic compatibility (EMC) Cable tie
Figure 4-10 Connection of shielding bus The shielding bus must be connected to the PE busbar. If shielded cables have to be interrupted, the shield must be continued via the corresponding connector housing. Only suitable connectors may be used for this purpose.
Figure 4-11 Interruption of shielded cables If intermediate connectors, which do not have a suitable shield connection, are used, the shield must be continued by fixing cable clamps at the point of interruption. This ensures a large-area, HF-conducting contact. 4-30 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.1 Description 5 SIMATIC RF660R is a stationary reader for connecting up to 4 external antennas. A rugged housing with high IP65 degree of protection means that the device is a universal and reliable partner in harsh production environments, on conveyor systems, in warehouses, or directly at the loading gate. Figure 5-1 RF660R reader Highlights The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 1/2 and ISO/IEC 18000-6B standards Supports low-cost SmartLabels as well as reusable, rugged data media High reading speed: many tags can be read simultaneously (mass recording), rapidly moving tags are reliably recorded Suitable for the 865 to 868 MHz UHF bands in Europe and the 902 to 928 MHz UHF band in North America Up to 4 antennas can be connected and configured in operating mode Readers and antennas to the high IP65 degree of protection Can be used for a high temperature range Antenna switching for high reading probability Flexible system integration:
Serial (RS 232) SIMATIC integration (RS 422 over communication module; available soon) Ethernet (TCP/IP) RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-1 RF660R reader 5.1 Description Ordering data 5.1.1 Description SIMATIC RF660R Machine-Readable Product Code 5-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.1 Description 5.1.2 Design of the RF660R reader Item No.
(1)
(2)
(3)
(4)
(5)
(6) Description Status LED Industrial Ethernet
(RJ45 connector) RS 422 interface
(8-pin M12 connector) RS 232 interface
(5-pin M12 connector) Digital I/O
(8-pin M12 connector) Power, 24 V DC;
(4-pin M12 connector) Description 4 antenna connections ANT 1 to ANT 4 (RTNC connector)
RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-3 RF660R reader 5.1 Description 5.1.3 Status displays Status displays LEDs Power on Color Meaning Green Power supply ON
(also lit for undervoltage/overvoltage) Tag Detect System Error Red Yellow LED is lit as soon as any tag is in the field Reader is not active. Rebooting is necessary (operating voltage Off On.) 5-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.1 Description 5.1.4 Pin assignment of the serial interfaces RS 422 connector
RS 232 connector
Industrial Ethernet
Pin Meaning 1 2 3 4 5 6 7 8 GND not connected RS422_RX_PLUS RS422_RX_MINUS RS422_TX_MINUS RS422_TX_PLUS GND housing Pin Meaning 1 2 3 4 5 6 7 8 GND RS232_TX GND RS232_RX GND not connected not connected not connected Pin Meaning 1 2 3 4 5 6 7 8 Transmit Data (+) Transmit Data (-) Receive Data (+) Terminated Terminated Receive Data (-) Terminated Terminated RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-5 RF660R reader 5.1 Description 5.1.5 Pin assignment and connections of the digital I/O interface Pin assignment Digital I/O socket
Pin Meaning 1 2 3 4 5 6 7 8 Input USER_IN (0) Input USER_IN (1) Input USER_IN (2) GND (IN) Output USER_OUT (0) Output USER_OUT (1) Output USER_OUT (2) Housing 5-6 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Connections
RF660R reader 5.1 Description
Figure 5-2 Connections for digital I/O Output USER_OUT (0), (1), (2):
(1) These are high-side switches that switch Vcc (+24V) at low resistance ('active high').
(2) Each output is rated for 0.5 A current and is electronically protected.
(3) The 0 V rail is Pin 4 (GND).
(4) Each pin of the 8-pin connector can carry a load of up to 2 A, this means that three digital outputs can be operated simultaneously with up to 0.5 A. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-7 RF660R reader 5.1 Description 5.1.6 Power supply Pin assignment of the power connections Power connector
Pin Meaning 1 2 3 4 Ground (0V)
+24 V
+24 V Ground (0V) 5-8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.1 Description 5.1.7 Grounding connection A low-impedance earth connection ensures that interference signals generated, for example, by external power supply cables or signal cables are safely discharged to earth. Required tool for protective earth terminal: TORX T20 screwdriver Ground connection/protective earth terminal The protective earth terminal (M4 threads) (1) on the device (large surface, large-area contact) has to be connected with the protective earth conductor of the plant or the cabinet in which the reader is to be installed. The minimum conductor cross-section may not be less than 2.5 mm2. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-9 RF660R reader 5.2 5.2 5.3 Installation /Mounting 5.3.1 Mounting/Installation Mounting/installing the device The positions of the fixing holes for the device are shown in the "Dimension drawing"
section. Examples of mounting types Material Concrete Plasterboard
(min. 13 mm thick) Metal
(min. 2 mm thick) Hole diameter 8 mm diameter 60 mm depth 14 mm diameter 5 mm diameter Fixing Rawlplug: 8 mm diameter, 50 mm length Screws: 4 mm diameter, 50 mm length Tilting rawlplug: 4 mm diameter, 50 mm length M4 metal screws: 4 mm diameter, 15 mm length Warning Ensure that the wall or ceiling can hold four times the total weight of the device. 5.4 Configuration/integration 5.4.1 Configuration 5-10 Three communication interfaces are available for integrating the device into system environments/networks:
RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.4 Configuration/integration Ethernet RS 422 and RS 232 The communication interfaces transfer the data to IT, ERP and SCM systems on SIMATIC PLCs or PCs (also used for configuration and diagnostics). Simple process controls (e.g. a traffic signal) can be directly implemented using the read/write device via three digital inputs and outputs with 24 V each.
Figure 5-3 Configuration overview of the RF660R reader Note Maximum cable lengths for the RS232 interface The maximum cable lengths for reliable, fault-free data transfer are as follows:
Transfer rate 115.2 kbit/s: Maximum cable length: 10 m Transfer rate 57,6 kbit/s: Maximum cable length: 20 m RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-11 RF660R reader 5.4 Configuration/integration 5.4.2 Transmission protocols Transmission protocols The following transmission protocols are available: 3964R protocol and TCP/IP. RS232 communication Transmission rates Start bits Data bits Parity Stop bits RS422 communication Transmission rate Start bits Data bits Parity Stop bits Ethernet communication XML protocol 115200 bps 1 8 Odd 1 3964R protocol 9600, 19200, 38400, 57600, 115200 bps
(autobauding) 1 8 Odd 1 The Ethernet interface offers automatic selection between 10BaseT and 100BaseTX. Shielded Twisted-Pair patch cables with standard RJ45 connectors are recommended for a reliable connection. 5-12 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.5 Maintenance and service 5.5 Maintenance and service RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-13 RF660R reader 5.6 Technical specifications 5.6 Technical specifications 5.6.1 Technical specifications of RF660R Table 5-1 Technical specifications of RF660R General Technical Specifications Weight Dimensions (L x W x H) in mm Material Frequencies European frequency range North American frequency range Frequency accuracy Channel spacing Modulation methods Identification rate 3.7 kg (with cover 3.8 kg) 320 x 145 x 100 without connections Aluminum 865 ... 868 MHz (10 subchannels LBT at 2 W ERP, 15 subchannels LBT at 0.1 W ERP) 902 ... 928 MHz (50 channels, frequency hopping) max. 10ppm Channel spacing (FHSS), 200 kHz > FHSS> 500 kHz DSB Modulation & SSB Modulation Encoding, Manchester or Pulse Interval (PIE) 99.5 % at maximum reading distance and with a receiver data transfer rate of 80 Kbyte/s. 5-14 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Transmission and reading characteristics Max. reads/s Europe - Single Tag Note:
The LBT and frequency channel schedule can affect this value EPC Generation 2 Up to 100 reads/s as part of the collision arbitration cycle USA - Single Tag Note:
The rate of frequency hopping can affect this value Up to 600 reads/s as part of the collision arbitration cycle Bulk Read Capacity Max. number of tags Europe USA Data Transmission Rate Reading (incl. TCP/IP) tag-to-reader link frequency EPC Generation 2 max. 1000 Up to 500 tags/s Up to 1000 tags/s EPC Generation 2 320 kbps at 3 m 80 kbps at 5 m 40 kbps at 5 m Reading (incl. TCP/IP) reader-to-tag mean data transfer rate 128 kbps at 3 m 53,3 kbps at 5 m 26,7 kbps at 5 m min. 110 to 130 ms Time required to program an individual EPC tag with a 96-bit ID using WRITE Time required to program an individual EPC tag with a 96-bit ID using BLOCK_WRITE or WRITE4BYTE Identification rate (%) Single tag under ideal conditions Single tag under normal conditions Transfer capacity Range Reading distance Antennas mounted on opposing sides RF660R reader 5.6 Technical specifications ISO 18000-6B Up to 100 tips, single tag only
> 50 as part of the collision arbitration cycle Up to 120 tips, single tag only
> 50 as part of the collision arbitration cycle ISO 18000-6B max. 75 Up to 45 tags/s Up to 75 tags/s ISO 18000-6B 160 kbps at 3 m 40 kbps at 5 m 40 kbps at 5 m Up to 60 ms approx. 25 ms 22 to 25 ms ISO 18000-6B
> 99,9 %
99,5 %
USA 0.4 to 4 W EIRP USA max. 10 m (with 2 x 2 antennas) EPC Generation 2
> 99,9 %
99,5 %
Europe 0.1 to 2 W ERP Europe max. 10 m (with 2 x 2 antennas) max. 5 m (with 2 antennas) max. 5 m (with 2 antennas) Approx. bytes/s Approx. bytes/s Approx. m/s (byte) Approx. m/s (byte) Antennas mounted on the same side Data transmission rate of reader Read Write Object speed Read Write RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-15 RF660R reader 5.6 Technical specifications Approvals Mechanical Environmental Conditions Shock Total shock response spectrum Vibration Climatic Conditions Ambient temperature in operation Ambient temperature for transport and storage Electromagnetic compatibility Status displays on the device Power On Tag Presence Error Interfaces Antenna connections Max. independently operating antenna channels Ethernet 10BaseT or 100BaseTx RS422 RS232 Digital inputs Digital outputs (short-circuit proof) Power supply 5-16 Radio to R&TTE- guidelines EN 300 330, EN 301 489
IEC60950, including US and Canadian variants of it CE, EMC, FCC, cULus FCC CFR47 Part 15.247 ETSI EN 302-208 Degree of protection acc. to EN 60529 (IP65) EN 60 721-3-7, Class 7 M2 Type II EN 60 721-3-7, Class 7 M2
-25 C to +55 C
-40 C to +85 C Green LED Yellow LED Red LED 4x RTNC connector Output values:
4 W with 4 dB cable attenuation and 6 dB antenna amplification. Minimum output voltage: 100 mW 2 1x RJ45 connection according to IEEE 802.3 and ISO 8802-3 1x connector (8-pin M12). Bit rate between 2400 and 115200 bps. For integration in SIMATIC 1x connector (5-pin M12). Bit rate between 2400 and 115200 bps. 3x sockets (8-pin M12). 3x sockets (8-pin M12) Power supply: 24 V; 1 A Fuse: 24 V; 0.5 A 24 V DC (4-pin M12) 20 to 30 V (2.2 A) RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.7 Dimension drawings 5.7 Dimension drawings 5.7.1 Dimension drawings
Figure 5-4 Dimension drawing of the reader RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-17 RF660R reader 5.8 Certificates and approvals 5.8 Certificates and approvals 5.8.1 FCC information Siemens SIMATIC RF660R FCC ID: NXW-RF660 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 5.8.2 Compliance distance for RF Exposure The Transmitter is within the Health Canada and FCC limits for General Population/Uncontrolled Exposure to electromagnetic waves at a minimum operating distance of 23 cm. The installation design shall thus be such as to maintain a minimum distance of 23 cm between the antennas and users or other persons. 5-18 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, RF660R reader 5.8 Certificates and approvals RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 5-19 Antennas 6.1 RF660A antenna 6.1.1 RF660A description 6 The RF660A is a stationary antenna, specially designed for the RF660R reader. The antenna is available in two different frequency ranges that have been specified for the regions of Europe and USA. Frequency range The antenna for Europe operate in the frequency range of 865 to 868 MHz The antenna for the USA operate in the frequency range of 902 to 928 MHz Design of the RF660A The antenna is installed in a rectangular plastic housing.
Front view
Side view RTNC connection RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6-1 Antennas 6.1 RF660A antenna Radiating/receiving characteristic The characteristic curve is shown for horizontal alignment and for a frequency of 865 MHz. The radiating/receiving angle of the antenna is defined by the angle between the two 3dB points.
Figure 6-1 Effective range of radiation (at 865 MHz, horizontal alignment) 6-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Ordering data Antennas 6.1 RF660A antenna Description RF660A for Europe RF660A for USA Machine-Readable Product Code 6GT2 810-0AA00 6GT2 810-0AA01 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6-3 Antennas 6.1 RF660A antenna 6.1.2 Application Planning Specified minimum spacing of antennas The following diagram shows the specified minimum and maximum spacings for mounting antennas:
A minimum spacing of 50 cm is necessary between the antenna and liquids or metals. The distance between the antenna and the floor should also be at least 50 cm.
Figure 6-2 Distance to the environment The distance between two antennas mounted alongside each other or one above the other should be at least 20 to 50 cm. 6-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Antennas 6.1 RF660A antenna
Figure 6-3 Antennas mounted adjacently horizontally or vertically For a portal configuration, the distance between two antennas that are connected to the same reader is up to 3.5 m (in Europe) or 4 m (in the USA).
Figure 6-4 Portal configuration RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6-5 Antennas 6.1 RF660A antenna 6.1.3 Installation /Mounting Mounting types The RF660A antenna can be fixed to any firm support. Two systems are available for fixing the antenna:
Rigid fixing with VESA 100 x 100 Flexible fixing with VESA 75 x 75 Fixing with VESA 100 x 100 Rigid fixing with an antenna adapter plate is suitable for:
Wall mounting on solid foundations Mast mounting Description Keyhole for wall mounting (4 x) Elongated hole for mast mounting (4 x) Standardized VESA fixing holes (4 x) Antenna with antenna adapter plate
6-6 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Antennas 6.1 RF660A antenna Antenna with antenna adapter plate
Description Dimensions for fixing holes All dimensions in mm
RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6-7 Antennas 6.1 RF660A antenna Fixing with VESA 75 x 75 Flexible mounting is possible using the VESA 75 x 75 mounting set. VESA 75 x 75 mounting set Description Swivel range of wall mounting Distances for wall mounting VESA adapter plate from VESA 75 x 75 to VESA 100 x 100 6-8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, VESA 75 x 75 mounting set Antennas 6.1 RF660A antenna Description 6.1.4 Connecting an antenna to a reader Connecting an RF660A Preassembled standard cables in lengths of 10 m and 20 m with the optimal impedance are available for connection. The cable between antenna and reader can be up to 20 m in length. Notice Only use original Siemens antenna cables
Figure 6-5 Rear of antenna with RTNC connection When less than four antennas are used, we recommend that the antennas are connected to the reader as follows. Number of antennas 2 antennas 3 antennas Connections on the reader ANT 1, ANT 2 ANT 1, ANT 2, ANT 3 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 6-9 Antennas 6.1 RF660A antenna Technical specifications 6.1.5 Frequency range Impedance Antenna amplification VSWR Polarization Radiating/receiving angle Connector Degree of protection Permissible ambient temperature RF660A antenna 865-868 865-868 MHz 50 Ohm nominal 5-7 dBil 2:1 max. RH circular 55-60 RTNC IP 65
-25 C to +75 C RF660A antenna 902-928 902-928 MHz 50 Ohm nominal
> 6 dBic 2:1 max. RH circular 60 - 75 RTNC IP 65
-25 C to +75 C 6-10 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Transponder/tags 7.1 Mode of operation of transponders 7 The tag/transponder mainly comprises a microchip with an integral memory and a dipole antenna. The principle of operation of a passive RFID transponder is as follows:
Diversion of some of the high-frequency energy emitted by the reader to supply power to the integral chip Commands received from reader Responses are transmitted to the reader antenna by modulating the reflected radio waves (backscatter technique)
Figure 7-1 Mode of operation of transponders
The transmission ranges achieved vary in accordance with the size of the tag and the corresponding dipole antenna. In general the following rule applies: The smaller the tag and therefore the antenna, the shorter the range. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 7-1 Transponder/tags 7.2 Transponder classes and generations The transponder classes are distinguished by the different communication protocols used between the reader and transponder. Transponder classes are mostly mutually incompatible. The following transponder classes are supported by the RF 600 system:
EPC Global Class 1, 1b with full EPC Global Profile EPC Global Class 1, Generation 2 with full EPC Global Profile ISO 18000-6B with full ISO profile EPC Global EPC Global groups tags into the following classes and generations:
EPC class Definition Programming Class 0 Passive read-only tags Class 1 Passive single-write tags Class 2 Class 3 Class 4 Passive rewritable tags Semi-passive tags Active tags Programming by the manufacturer Programming by the customer
(cannot be reprogrammed) Freely programmable Supported by RF 600 No Yes No Characteristic Frequency Memory capacity Can be programmed on site Programming Other characteristics Generation 1 860-930 MHz 64 or 96 bits Yes Class 0: Read-only Class 1: written once; read many times _ Generation 2 860-960 MHz 96-256 bits Yes Yes Reading is faster and more reliable than for Generation 1. Enhanced compliance with global standards. 7-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, ISO 18000-6 Transponder/tags Specification of the transponder/tags in accordance with ISO 18000-6 refers to implementation of the air-interface protocol. There are two versions: ISO 18000-6 Type A and ISO 18000-6 Type B. Frequency range Transmission procedure Bi-phase modulation and Manchester Type B 860 to 960 MHz encoding Type A 860 to 960 MHz Pulse Interval Encoding (PIE) Anti-collision techniques Adaptive binary tree technique Protocol Supported by RF 600 Reader talks first Yes ALOHA technique Reader talks first No RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 7-3 Transponder/tags 7.3 Electronic Product Code (EPC) The Electronic Product Code (EPC) supports the unique identification of objects (e.g. retail items, logistical items or transport containers). This makes extremely accurate identification possible. In practical use, the EPC is stored on a transponder (tag) and scanned by the reader. Different EPC versions exist from 64 to 204 bits. The structure of a 96-bit EPC is shown below :
Header: This identifies the EPC identification number that follows with regard to length, type, structure and version of the EPC EPC manager number: This identifies the company/corporation. Object class: Corresponds to the article number. Serial number: Consecutive number of the article 7-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Accessories Accessories Antenna cable Cable Mounting set Further accessories Wide-range power supply unit for SIMATIC RF systems Up to 20 m RS 422: Up to 50 m RS 232: Up to 10 m Ethernet: Up to 20 m Yes, 2 different types Documentation on CD-ROM Order No. 8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 8-1 Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1 Wide-range power supply unit for SIMATIC RF systems
(1) DC output 1
(2) DC output 2
(3) Mains connection
Features 8.1.1 Wide-range power supply unit for RF systems
Features Wide-range input for use worldwide Dimensions without mains cable: 175 x 85 x 35 mm Dimensions including mains cable: 250 x 85 x 35 mm CE compatible Mechanically and electrically rugged design Secondary side: 24V DC / 3A Short-circuit and no-load stability Suitable for frame mounting 3 designs for use in the EU, UK, USA 8-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Description Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems The wide-range power supply unit for SIMATIC RF systems is a universal compact power supply and provides the user with an efficient, cost-saving solution for many different mid-
range power supply tasks. The primary switched power supply is designed for use on single-phase AC systems. The two DC outputs (sockets) are connected in parallel and protected by a built-in current limiting circuit against overload and short-circuits. The device is vacuum cast, prepared for applications of Safety Class 2 and satisfies the low-
voltage guideline as well as the current EU standards for CE compliance. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 8-3 Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1.2 Scope of supply Wide-range power supply unit for SIMATIC RF systems 2 m mains cable (country-specific) Protective cover for flange outlet Operating instructions Ordering data 8.1.3 Wide-range power supply unit for SIMATIC RF systems
(100 - 240 V AC / 24 V DC / 3 A) with 2 m connecting cable with country-specific plug 24 V-connecting cable, length 5 m EU: 6GT2 898-0AA00 UK: 6GT2 898-0AA10 US: 6GT2 898-0AA20 6GT2 491-1HH50 8.1.4 Safety Information Warning Danger to life It is not permitted to open the device or to modify the device. The following must also be taken into account:
Failure to observe this requirement shall constitute a revocation of the CE approval and manufacturer's warranty. For installation of the power supply, compliance with the DIN/VDE requirements or the country-specific regulations is essential. The field of application of the power supply is limited to "Information technology in electrical office equipment" within the scope of validity of the EN 60950/VDE 0805 standard. When the equipment is installed, it must be ensured that the mains socket outlet is freely accessible. The housing can reach a temperature of +25 C without any adverse consequences. It must, however, be ensured that the power supply is covered in the case of an ambient temperature of more than +25C to protect persons from contact with the hot housing. Adequate ventilation of the power supply must be maintained under these conditions. 8-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1.5 Connecting There are three different (country-specific) mains cables for the EU, UK and US. The appropriate mains cable must be connected to the primary input of the power supply. The wide-range power supply unit has total insulation (Safety Class 2) Can be mounted using four fixing holes RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 8-5 Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1.6 Technical specifications Table 8-1 General technical specifications Insulation stability (prim./sec.) Uins p/s Insulation resistance Rins Leakage current Ileak Safety class (SELV) Mains buffering th Ambient temperature Surface temperature Storage temperature Self-heating on full-load Interference immunity ESD HF fields Burst Surge HF injection Mains quality test Cooling Dimensions L x W x H Weight Housing / casting Power supply class 3.3 kVAC
>1 G
< 200 A Uin= 230 VAC, f = 50 Hz Designed for installation in devices of Safety Class 2 Uin= 230 VAC Module top, centrally EN 61000-4-2, 4-3 up to 4-6, 4-11 50 ms
-25 C to +55 C max. 96 C
-40 C to +85 C max. 45 K Air discharge: 15 kV 10 V/m symmetrical: 2 Symmetrical: 1 10 Vrms according to CSA Free convection tbd x 85.0 x 35.0 mm 720 g UL 94-V0 Level 3 Table 8-2 Technical specifications for the input Rated input voltage Uin EN 60950 / UL 60950 Input voltage range Uin Input frequency fin Radio interference level Switching frequency fsw Length of cable 100 to 240 V AC 120 to 353 VDC 94 to 264 V AC 120 to 375 VDC
(UL: 353 VDC) 50/60 Hz EN 55011/B approx. 70 kHz typ. 2 m 8-6 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems Table 8-3 Technical specifications of the output Output voltage tolerance Uout Overvoltage protection Noise ULF Noise UHF Line Regulation Load Regulation Short-circuit current Imax Settling time tR load variations Temperature coefficient Overload behavior Pover Short-circuit protection/
No-load response Derating Connector type Table 8-4 Output configurations Uin= 230 VAC Uin= min., BW: 1 MHz Uin= min., BW: 20 MHz Uin= min./max. Iout= 10...90...10 %
Inom = 4 A (+50C) Iout= 10...90...10 %
TA= -25 C to +70 C TA> +50 C to +70 C Flanged connector Fa. Binder, Order No.:09-3431-90-04 Uoutnom +2 %/-1 %
Uout nom +20 % typ. 1 % Uout 2 % Uout 1,0 %
1,0 %
105 up to 130 % Inom
< 5 ms 0.01 %/K Constant current Continuous/no-load stability max. 2 %/K 4 pins Input 110 V AC 110 V AC 220 V AC 220 V AC Outputs U1 = U2 24 V DC 24 V DC 24 V DC 24 V DC ILoad =
I1 + I2 0A 3A 0A 3A Efficiency
(%) 88 90 Remarks No-load stability No-load stability Table 8-5 Compliance with standards Name Electrical safety Conducted interference Emitted interference Values Standard EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition EN 61000-6-3 EN 55011 EN 61000-6-3 EN 55011 Class B Class B All values are measured at full-load and at an ambient temperature of 25 C (unless specified otherwise). RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 8-7 Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1.7 Modification possibilities Insulation strength up to 4 kVAC Output voltages Heatsink DIN rail mounting 8.1.8 Pin assignment of DC outputs and mains connection DC outputs
Mains connection
Assignment
(1) Ground (0V)
(2) +24 V DC
(3) +24 V DC
(4) Ground (0V) Assignment
(1) 100 to 240 V AC
(2) n.c.
(3) 100 to 240 V AC
(4) n.c. 8-8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8.1.9 Dimension drawing
Units of measurement:
All dimensions in mm
RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, 8-9 Accessories 8.1 Wide-range power supply unit for SIMATIC RF systems 8-10 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Appendix A A.1 Certificates and approvals Notes on CE marking The following applies to the system described in this documentation:
The CE marking on a device is indicative of the corresponding approval:
DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001:
1987). This has been certified by DQS (the German society for the certification of quality management systems.) EQ-Net certificate no.: 1323-01 Certification for the USA, Canada and Australia Safety RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, A-1 Appendix A.1 Certificates and approvals One of the following markings on a device is indicative of the corresponding approval:
Underwriters Laboratories (UL) to UL 60950 Standard (I.T.E), or to UL508
(IND.CONT.EQ) Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950
(I.T.E) or C22.2 No. 142 (IND.CONT.EQ) Underwriters Laboratories (UL) according to standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142
(IND.CONT.EQ) UL recognition mark Canadian Standard Association (CSA) per Standard C22.2. No. 60950 (LR 81690) or per C22.2 No. 142 (LR 63533) Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533) A-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, EMC Appendix A.1 Certificates and approvals USA Federal Communications Commission Radio Frequency Interference Statement Shielded Cables Modifications This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded cables must be used with this equipment to maintain compliance with FCC regulations. Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Conditions of Operations This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CANADA Canadian Notice Avis Canadien AUSTRALIA This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe b est conforme la norme NMB-003 du Canada. This product meets the requirements of the AS/NZS 3548 Norm. RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, A-3 Appendix A.2 Service and support A.2 Service and support Technical support You can reach the technical support team for all A&D projects at Telephone: +49 (0) 180 5050 222 Fax: +49 (0) 180 5050 223 Internet Visit our site on the Internet at:
http://www.siemens.com/automation/service&support You can send a support query to:
http://www.siemens.de/automation/support-request You can find the latest general information about our identification systems on the Internet at:
http://www.siemens.de/simatic-sensors The online catalog and the online ordering system is available at:
http://mall.automation.siemens.com/
A-4 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Appendix A.3 Contact partners A.3 Contact partners If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office. The addresses are found on the following pages:
On the Internet at: http://www.siemens.com/automation/partner In catalog CA 01 In Catalog FS 10 specially for factory automation sensors A.4 Training Training center We offer appropriate courses to get you started. Please contact your regional Training Center, or the central Training Center in D-90327 Nuremberg. Telephone: +49 (911) 895-3200 http://www.sitrain.com RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, A-5 Appendix A.4 Training A-6 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Index A Accessories of the RF660R reader, 8-1 Antenna configuration, 4-2 Approvals, A-1 C Cable Shielding, 4-29 Certificates, A-1 Classes, 7-2 Configuration, 5-10 Antennas, 4-2 Contact partners, A-5 Coupling paths, 4-26 D Design of the RF660R reader, 5-3 Dimensions RF660R reader, 5-17 E Electromagnetic compatibility Coupling paths, 4-26 Electromagnetic interference, 4-23 Electromagnetic waves UHF range, 4-13 EMC Directives, A-3 EMC Guidelines Avoiding interference, 4-27 Basic rules, 4-20 Cable shielding, 4-29 Definition, 4-20 Equipotential bonding, 4-28 Overview, 4-19 Propagation of electromagnetic interference, 4-23 Equipotential bonding, 4-28 G Gate configuration Application areas, 4-3 Arrangement of antenna, 4-3 Generations, 7-2 I Identification system Performance Features, 3-3 UHF range, 3-1 Influence of Interference, 4-13 Liquids, 4-15 Metals, 4-14 Non-metallic substances, 4-15 reflections, 4-13 Interfaces, 5-10 Digital, 5-6 Serial, 5-5 Interference, 4-13 Interference sources Electromagnetic, 4-24 M Main applications RF600, 3-2 Minimum distances For antennas, 4-7, 6-4 Mounting types of the RF660R reader, 5-10 P Performance Features RF600, 3-3 Portal configuration Application example, 4-2 Power supply, 5-8 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618, Index-1 Index R Reading range Dependency of the, 4-10 reflections, 4-13 Regulations applicable to UHF frequency bands Europe, 4-16 USA, 4-18 RF600 Main applications, 3-2 Performance Features, 3-3 System requirements, 3-3 RF660A antenna Design, 6-1 Mounting types, 6-6 Ordering data, 6-3 Radiating/receiving characteristic, 6-2 Technical specifications, 6-10 RF660R reader Accessories, 8-1 Configuration, 5-10 Design, 5-3 Dimensions, 5-17 Examples of mounting types, 5-10 FCC information, 5-18 Interfaces, 5-5, 5-6, 5-10 Power supply, 5-8 Status displays, 5-4 Technical specifications, 5-14 Transmission protocols, 5-12 S Safety Information, 2-1 Service, A-4 Shielding, 4-29 Status LEDS of the RF660R reader, 5-4 Support, A-4 System overview SIMATIC RF600, 3-1 System requirements RF600, 3-3 T Technical specifications RF660A antenna, 6-10 RF660R reader, 5-14 Training center, A-5 Transmission protocols, 5-12 Transponder Classes, 7-2 Generations, 7-2 how it works, 7-1 Improving detection, 4-13 W Wide-range power supply unit Safety Information, 8-4 Technical specifications, 8-6 Index-2 RF600 System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2005-11-03 | 902 ~ 928 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2005-11-03
|
||||
1 | Applicant's complete, legal business name |
Siemens AG
|
||||
1 | FCC Registration Number (FRN) |
0006191076
|
||||
1 | Physical Address |
Gleiwitzer Str. 555
|
||||
1 |
Nuernberg, N/A 90475
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@babt.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
NXW
|
||||
1 | Equipment Product Code |
RF660
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T******** E******** S********
|
||||
1 | Title |
Manager, Compliance Engineering
|
||||
1 | Telephone Number |
00499********
|
||||
1 | Fax Number |
00499********
|
||||
1 |
t******@siemens.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Roke Manor Research Limited
|
||||
1 | Name |
J****** S********
|
||||
1 | Physical Address |
Roke Manor
|
||||
1 |
Hampshire, SO51 0ZN
|
|||||
1 |
United Kingdom
|
|||||
1 | Telephone Number |
+4417********
|
||||
1 | Fax Number |
+4417********
|
||||
1 |
j******@roke.co.uk
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is conducted. The Antenna(s) used for this transmitter must be installed to provide a separation distance of at least 23 cm from all persons and must not be co-located or operated in conjunction with any other Antenna or transmitter. End users must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
RFI Global Services Ltd.
|
||||
1 | Name |
A******** H********
|
||||
1 | Telephone Number |
44-12********
|
||||
1 | Fax Number |
44-12********
|
||||
1 |
a******@rfi-global.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.00000000 | 928.00000000 | 0.8910000 | 10.0000000000 ppm | 500KK7D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC