WIRELESS THR GATEWAY UserManual Benutzerhandbuch FCC ID: SCF6021112 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfer-
ence, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications not expressly approved by this company could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital de-
vice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec-
tion against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. This device has been designed to operate with the antennas listed below, and having a maximum gain of 6 dB. Antennas not included in this list or having a gain greater than 6 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. IC: 10971A-6021112 This device complies with Industry Canada licence-exempt RSS standards. Operation is subject to the following two conditions: (1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired opera-
tion of the device. This device has been designed to operate with the antennas listed below, and having a maximum gain of 6 dB. Antennas not included in this list or having a gain greater than 6 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Ce dispositif a t conu pour fonctionner avec les antennes indiques ci-dessous, et ayant un gain maximum de 6 dB. Il est strictement interdit dutiliser les antennes ne figurant pas dans cette liste ou prsentant un gain suprieur 6 dB avec ce dispositif. Limpdance dantenne requise est 50 ohms. Use the following Agilion Antennas only:
Omni/4.5dBi/N-M Omni/6dBi/N-F/360 Table of contents English 1 Scope of delivery .......................................................................................................... 2 Functionality ................................................................................................................. 3 Layout and Connections ............................................................................................... 4 Connectors and Indicators........................................................................................ 5 Pin-Assignment ......................................................................................................... 5 Initial operation and installation ................................................................................. 7 Troubleshooting ........................................................................................................... 8 General errors ........................................................................................................... 8 Technical data............................................................................................................... 9 Declaration of Conformity ........................................................................................... 10 2 3 3.1 3.2 4 5 5.1 6 7 20130314-6021112-UM 1 EN 1 Scope of delivery 1 WIRELESS THR GATEWAY 1 Power plug (5-pole) 1 User manual EN 2 20130314-6021112-UM 2 Functionality The gateways are basing points in the localization network. Furthermore they are the interface between the IT infrastructure (e.g. Ethernet) and the wireless localization network. The IT infra-
structure is used for the exchange of localization information and application specific data be-
tween the wireless localization network and the localization server. The use of several gateways is recommended in larger localization networks for larger amount of mobile tags and highest availa-
bility of position information. 20130314-6021112-UM 3 EN 3 Layout and Connections m m 0 1 m m 6 8 35mm P1 6 7 8 9 10 S1 D2 D1 P3 P2 P3 m m 7 5 D5 D6 P2 Bottom View EN 4 20130314-6021112-UM 3.1 Connectors and Indicators Connection /Indication Specification S1 P1 - POWER P2 - ETH P3 - Antenna D1 - Radio-LED D2 - Power-LED Push Button, Factory Defaults Power supply connector Ethernet Receptacle, RJ45 RP-SMA antenna connection Indication of wireless transmissions On when running, blinking on error 3.2 Pin-Assignment P1 - POWER - Connector P1 6 7 8 9 10 5-pole connector with clamping screw 0.13 mm2 to 3.3 mm2 Reorder with order number: 6020154 Pin 6 7 8 9 10 Description Alarm switsch GND (Ground) GND (Ground) 8 to 30 V DC Shield Ethernet Alarm switch - Pin 6 The high side switch power input Pin 9 to the digital output line Pin 6. Power Supply Alarm Switch Ground 9 9 6 6 8 7 GND GND Output Voltage: 0 (disabled) or Power Input Voltage (enabled) Maximum Output Current: 100 mA 20130314-6021112-UM 5 EN P4 - ETH-Connector, RJ45 Description Differential Ethernet transmit Data +
Differential Ethernet transmit Data -
Differential Ethernet receive Data +
Differential Ethernet receive Data -
Pin 1 2 3 6 4, 5, 7, 8 Shield not connected Shield D5 Off Yellow Green Description No Link 10 MBit 100 MBit D6 Off Yellow Green Description no activity half duplex activity full duplex activity P3 - Antenna - RP-SMA Connector Pin 1 Shield Description Antenna Ground EN 6 20130314-6021112-UM 4 Initial operation and installation 1. The antenna (P3) must be attached to the RP-SMA-connection at the WIRELESS module. Warning: Do operate the WIRELESS Module without antenna connected. While changing or removing antenna switch the device off or remove power cable. Notice: The antennas should be justified in same direction on all WIRELESS modules. Notice: The WIRELESS modules should be placed line of sight and in a high position for op-
timised wireless data transmission. 2. Set up power connection (P1). During start-up all LEDs are flashing once. The power-LED
(D2) keeps on lighting. 3. The WIRELESS modules must be protected against humidity. 20130314-6021112-UM 7 EN 5 Troubleshooting 5.1 General errors Effect Reason Action Module does not work, Power-
LED is off No power connection or not switched on Check power supply, switch WIRELESS module on Flashing Power-LED at normal operation Module Error Switch WIRELESS module off and on for reset, if error occurs frequently contact service@agilion.de EN 8 20130314-6021112-UM 6 Technical data Radio Wireless technology IEEE 802.15.4a nanoLOC, Modulation: Chirp Spread Spectrum (CSS) Data rates 1 MBit Operating frequency 2.45 GHz ISM-Band Chirp-bandwidth 80 MHz Output power max. 100 mW, adjustable Range @ 1 MBit Indoor max. 90 m, Outdoor max. 1,000 m Connectors and Power Supply voltage 8 to 30 V DC Power consumption max. 0.2 A Antenna interface Power connector RP-SMA (male) 5-pole connector with clamping screw, 0.13 mm2 to 3.3 mm2, Order#: 6020154 Ethernet RJ45 Ethernet Ethernet Interface 10/100MBit Duplexmode Half-, Fullduplex Environment Case Plastic housing IP-protection IP 40 Dimension Weight Mounting 35 x 86 x 58 mm 80 g DIN 60 715 TH35 Temperature range
-40 to +70C 20130314-6021112-UM 9 EN 7 Declaration of Conformity The Agilion GmbH declares the conformity of WIRELESS THR GATEWAY according to the requirements of the standards:
EN 300328 EN 301489-1 EN 301489-17 EN 61000-3-2:2000+A1:2005 EN 61000-3-3:1995+A1:2001 EN 55022:1998+A1:2000+A2:2003 EN 55022:1994+A1:1995+A2:1997 EN 55024:1998+A1:2001+A2:2003 EN 60950-1 WIRELESS THR GATEWAY therefore complies with the EC-directives:
R&TTE 1999/5/EC 89/336/EEC 73/23/EWG symbol. Validity is lost if modifications are This declaration applies to all devices bearing the made to the product. Dipl.-Inf. Sven Sieber Dipl.-Kfm.(FH) Andreas Werner
(Managing Director) (Managing Director) Agilion GmbH Blankenauer Str. 74 09113 Chemnitz Germany EN 10 20130314-6021112-UM Inhaltsverzeichnis Deutsch Lieferumfang ................................................................................................................. 2 berblick....................................................................................................................... 3 Mechanik und Anschlsse ............................................................................................ 4 Anschlsse und Anzeigen.......................................................................................... 5 Pin-Belegung ............................................................................................................. 5 Inbetriebnahme und Installation ................................................................................. 7 Behebung von Strungen ............................................................................................. 8 Allgemeine Fehler...................................................................................................... 8 Technische Daten ......................................................................................................... 9 Konformittserklrung ............................................................................................... 10 1 2 3 3.1 3.2 4 5 5.1 6 7 20130314-6021112-UM 1 DE 1 Lieferumfang 1 WIRELESS THR GATEWAY 1 Power-Stecker (5-polig) 1 Benutzerhandbuch DE 2 20130314-6021112-UM 2 berblick Die Gateways fungieren wie Ankerknoten als Referenzpunkt zur Lokalisierung, besitzen aber zu-
stzlich eine Schnittstelle zur Anbindung an eine IT-Infrastruktur (z.B. Ethernet oder USB). ber diese werden die Daten zur Lokalisierung als auch optional applikationsspezifische Daten zwi-
schen den drahtlosen Lokalisierungsnetzwerk und dem Lokalisierungsserver ausgetauscht. In greren Netzwerken ist der Einsatz mehrerer Gateways empfohlen, da so die Anzahl der mgli-
chen Tags und die Verfgbarkeit von Positionsinformationen erhht werden kann. 20130314-6021112-UM 3 DE 3 Mechanik und Anschlsse m m 0 1 m m 6 8 35mm P1 6 7 8 9 10 S1 D2 D1 P3 P2 P3 m m 7 5 D5 D6 P2 Ansicht von Unten DE 4 20130314-6021112-UM 3.1 Anschlsse und Anzeigen Anschluss / Anzeige Beschreibung S1 P1 - POWER P2 - ETH P3 - Antenne D1 - Radio-LED D2 - Power-LED Taster, Werkseinstellungen Stromversorgung XPort - RJ45 Ethernet RP-SMA - Antennenanschluss LED zur Signalisierung der Funkaktivitt (Senden und Empfangen) LED leuchtet wenn Gert in Betrieb, blinkt bei Fehler 3.2 Pin-Belegung P1 - POWER - Steckverbinder P1 6 7 8 9 10 5-poliger Steckverbinder mit Schraubklemmen 0,13 mm2 bis 3,3 mm2 Nachbestellung mit Bestellnummer: 6020154 Pin 6 7 8 9 10 Beschreibung Meldeausgang GND (Masse) GND (Masse) 8 bis 30 V DC Schirmung Ethernet Meldeausgang - Pin 6 Ein High-Side-Switch schaltet die Versorgungsspannung auf den digitalen Ausgang Pin 6. Versorgungs-
spannung Melde-
ausgang Masse 9 9 6 6 8 7 GND GND Ausgangsspannung: 0 (ausgeschaltet) oder Eingansspannung
(eingeschaltet) Maximaler Ausgangsstrom: 100 mA 20130314-6021112-UM 5 DE P2 - ETH-Buchse, RJ45 (nur bei ETH) Pin 1 2 3 6 4, 5, 7, 8 Gehuse D5 Off Gelb Grn Beschreibung Differential Ethernet transmit Data +
Differential Ethernet transmit Data -
Differential Ethernet receive Data +
Differential Ethernet receive Data -
Nicht verwendet, abgeschlossen Schirmung Funktion Kein Link 10 MBit 100 MBit D6 Off Gelb Grn Funktion Keine Aktivitt Halbduplex Aktivitt Vollduplex Aktivitt P3 - Antenne - RP-SMA Stecker Beschreibung Antenne GND (Masse) Pin 1 Shield DE 6 20130314-6021112-UM 4 Inbetriebnahme und Installation 1. Antenne an RP-SMA-Anschluss (P3) anschlieen. Achtung: Das WIRELESS Modul darf nicht ohne Antenne betrieben werden. Zum Wechseln oder Entfernen der Antenne ist das Gert auszuschalten bzw. stromlos zu schalten. Hinweis: Die Antennen sollten an allen WIRELESS-Modulen gleich ausgerichtet sein. Hinweis: Um eine optimale bertragung zu ermglichen, sollten die WIRELESS-Module mg-
lichst weit oben angebracht werden und Sichtverbindung haben. 2. Anschluss der Stromversorgung an den Power-Eingang (P1). Dabei leuchten alle LEDs initial auf. Die Power-LED (D2) leuchtet permanent. 3. Die WIRELESS-Module mssen vor Feuchtigkeit geschtzt werden. 20130314-6021112-UM 7 DE 5 Behebung von Strungen 5.1 Allgemeine Fehler Fehlererkennung Fehlerursache Fehlerbehebung WIRELESS-Modul reagiert nicht, LED leuchtet nicht Modul nicht angeschlossen oder nicht eingeschaltet Stromversorgung des Moduls prfen, Modul anschalten Blinkende Power-LED whrend des Betriebs Fehler in Modul Rcksetzen durch Aus- & An-
schalten des Moduls; tritt der Fehler mehrfach auf, kontaktie-
ren sie bitte service@agilion.de DE 8 20130314-6021112-UM 6 Technische Daten Funk Funkverfahren IEEE 802.15.4a nanoLOC, Modulationsverfahren: Chirp Spread Spectrum (CSS) Datenrate 1 MBit Frequenzbereich 2,45 GHz ISM-Band Chirp-Bandbreite 80 MHz Sendeleistung max. 100 mW, einstellbar Reichweite @ 1 MBit Indoor max. 90 m, Outdoor max. 1.000 m Anschlsse und Energieversorgung Spannung 8 bis 30 V DC Energieaufnahme max. 0,2 A Antennenanschluss Power-Steckverbinder 5-poliger Steckverbinder mit Schraubklemme, 0,13 mm2 bis 3,3 mm2, RP-SMA-Stecker Bestell-Nr.: 6020154 Ethernet RJ45 Ethernet Ethernet Interface 10/100MBit Duplexmode Halb-, Vollduplex Umgebung Gehuse IP-Schutzart Abmessungen Gewicht Plastikgehuse IP 40 35 x 86 x 58 mm 80 g Befestigungsmglichkeiten Normschiene DIN 60 715 TH35 Temperaturbereich
-40 bis +70C 20130314-6021112-UM 9 DE 7 Konformittserklrung Die Agilion GmbH erklrt die Konformitt von WIRELESS THR GATEWAY mit den Anforderungen der Normen:
EN 300328 EN 301489-1 EN 301489-17 EN 61000-3-2:2000+A1:2005 EN 61000-3-3:1995+A1:2001 EN 55022:1998+A1:2000+A2:2003 EN 55022:1994+A1:1995+A2:1997 EN 55024:1998+A1:2001+A2:2003 EN 60950-1 WIRELESS THR GATEWAY entspricht den EG-Richtlinien:
R&TTE 1999/5/EC 89/336/EEC 73/23/EWG
- Zeichen tragen. Bei Vernderungen an dem Pro-
Diese Erklrung gilt fr alle Gerte, die das dukt geht die Gltigkeit verloren. Dipl.-Inf. Sven Sieber Dipl.-Kfm.(FH) Andreas Werner
(Geschftsfhrer) Agilion GmbH Blankenauer Str. 74 09113 Chemnitz
(Geschftsfhrer) DE 10 20130314-6021112-UM Notes/Notizen:
Agilion GmbH Blankenauer Strae 74 09113 Chemnitz Germany Tel.: +49 - (0)371 - 45 00 48-0 Fax.: +49 - (0)371 - 45 00 48-11 www.agilion.de service@agilion.de Management/Geschftsfhrung:
Sven Sieber Andreas Werner HR B 21249 Chemnitz USt.-IdNr.: DE236591552