s Compact Operating Instructions 12/2018 SINAMICS G120 SINAMICS G120 Smart Access (option) SINAMICS G120 For more information about the module, see SINAMICS G120 Smart Access Operating Instructions. SINAMICS G120 SINAMICS G120 Smart Access Functionality SINAMICS G120 Wi-Fi PC SINAMICS G120 JOGSINAMICS G120 SINAMICS G120 Smart Access is a Wi-Fi-based Web server module and an engineering tool. It allows web-
based access to the supported SINAMICS G120 inverter from a connected device (a conventional PC with a wireless network adapter installed, a tablet, or a smart phone), realizing inverter operations such as quick setup, parameterization, JOG, monitoring, diagnostics, backup and restoring. SINAMICS G120 Smart Access is only for commissioning and thus cannot be used with the inverter permanently. Connecting the device Device with wireless network adapter PC Operating system Windows 7 Google Chrome 64.0.3239 IE 11.0.9600 Firefox 45.0.2 Windows 10 Edge 38.14393.1066 Firefox 45.0.2
/
Smart phone/tablet Apple iOS 10.2 Firefox 10.6 Safari Android 6.0.1 Google Chrome 64.0.3202.84 Firefox 45.0.2
*) Siemens recommends that you use the Web browsers listed above to achieve optimum browsing performance. 2018 Copyright 2018 Siemens Numerical Control Ltd., Nanjing A5E43332647-006 LED LED Status LED Inverter communication Wi-Fi Wi-Fi communication Color Solid red Solid green Solid red Solid yellow Solid green Flashing green Flashing yellow Alternating flashing red and yellow Description The communication between the module and the inverter is not established. The communication between the module and the inverter is established. The network communication is initializing. PC The network initialization completes but the module is not connected to a PC or mobile device. PC The connection between the module and the PC or mobile device is set up and you can open the Web pages now. PC The connection between the module and the PC or mobile device is set up and the Web page is open. Wi-Fi The module requires a restart because an upgrade completes or the Wi-Fi configuration is modified. The module is upgrading. Technical specifications Rated voltage 15 V DC Wireless technology and working frequency Wi-Fi 2400 MHz ... 2483.5 MHz Maximum radio frequency power 17.5 dBm (EIRP *)) Wireless modulation type Antenna gain
*) Extreme temperature range Recommended Web browser Operating ambient temperature 802.11 b/g 1.9 dBi
-10 C ... 60 C 0 C ... 50 C **)
*) EIRP EIRP means effective isotropic radiated power.
**) UL according to UL requirement SINAMICS G120 SINAMICS G120 Web address http://192.168.1.1 https://192.168.1.1 ( SSL requires download and installation of SSL certificates) SSL https:// Installing SSL certificates (https:// access only) Windows 10 PC iOS https:// SINAMICS G120 SSL To access the SINAMICS G120 Web pages with https:// from Windows 10-based PCs or iOS-based mobile devices, you need to install SSL certificates. Windows 10 PC Installing on Windows 10-based PCs 1. https://support.industry.siemens.com/cs/ww/en/ps/13225/dlG120 smart access certificates.ziproot-ca-cert.der Enter the certificate download Web site (https://support.industry.siemens.com/cs/ww/en/ps/13225/dl) and download the file "G120 smart access certificates.zip". Extract the certificate file "root-ca-cert.der" to your local drive. 2. root-ca-cert.der >
Double-click the file root-ca-cert.der and then select Install certificate > Next to open the certificate store. 3. Select Places all certificates in the following store and then browse to Trusted Root Certification Authorities. 4. > > SINAMICS G120 SINAMICS G120 Select "Next > Finish > OK " to complete the certificate installation. Now you are able to access the SINAMICS G120 Web pages via the SINAMICS G120 Smart Access. iOS Installing on iOS-based mobile devices 1. iOS iOS PC https://support.industry.siemens.com/cs/ww/en/ps/13225/dlG120 smart access certificates.ziproot-ca-cert.der iOS 3. iOS > >
G120 Smart Access 2018 Select "Settings > General > Profiles" to view configuration profiles in your iOS-based mobile device and make sure that the certificate has been issued to "G120 Smart Access 2018". 4. > > > G120 Smart Access 2018 SINAMICS G120 SINAMICS G120 As iOS devices do not support directly downloading files, enter the certificate download Web site Select " Settings > General > About > Certificate Trust Settings" to enable full trust for the root certificate
(https://support.industry.siemens.com/cs/ww/en/ps/13225/dl) from a non-iOS device (for example, a PC) and download the file "G120 smart access certificates.zip". Extract the certificate file "root-ca-cert.der" to your local drive of this non-iOS device. 2. "" iOS ""
""
Send the attached certificate file to an E-mail account of your choice (""). Use the built-in mail application ("") of your iOS-based mobile device to log in to your E-mail account (""), receive the attachment, and tap the attachment to install the certificate ().
"G120 Smart Access 2018". Now you are able to access the SINAMICS G120 Web pages via the SINAMICS G120 Smart Access. 2018 Copyright 2018 Siemens Numerical Control Ltd., Nanjing A5E43332647-006 Establishing initial wireless network connection 1. SINAMICS G120 WLAN > 3 Wi-Fi After you have fitted the SINAMICS G120 Smart Access to the inverter, power on the inverter and then hold down the WLAN button (> 3 s) to enable the Wi-Fi connection of the module. 2. PC Wi-Fi PC IP Activate the Wi-Fi interface inside your PC or mobile device. If you desire to establish the wireless network connection on your PC, make sure that you have previously enabled the automatic IP settings. 3. SINAMICS G120 SSIDG120 smart access_xxxxxxxxxxxx SINAMICS G120 MAC Search the wireless network SSID of the SINAMICS G120 Smart Access: G120 smart access_xxxxxx
("xxxxxx" stands for the last six characters of the module MAC address of the SINAMICS G120 Smart Access). 4. 12345678 Enter the wireless network password to launch the connection (default password: 12345678). 5. IP http://192.168.1.1 https://192.168.1.1 8. IP http://192.168.1.1 https://192.168.1.1 Enter the IP address (http://192.168.1.1 or https://192.168.1.1) in the supported browser. 6. 8 10 20 8 20 10...9 2A...Z3a...z4) _-
~!@#$%^&*
After the Web page for password change opens, enter a new password. The minimum requirement for the new password is 8 characters including numbers, uppercase and lowercase letters. To achieve better network access security, enter a new password of 10 to 20 characters (required character length: 8 to 20) that includes all of the following four categories of password characters: 1) numbers: 0 ... 9; 2) uppercase letters: A ... Z; 3) lowercase letters: a ... z; 4) special characters: _, -, ~, ! , @, #, $, %, ^, &, and *; the space character is not allowed. 8 9 10 20 8 9 10 20 Note that this password change page includes a security level indicator. The indicator displays as follows with the complexity of the new password:
Low: The password includes 8 or 9 characters and is a mixture of numbers, uppercase and lowercase letters. Medium: The password includes 10 to 20 characters and is a mixture of numbers, uppercase and lowercase letters. Or, the password includes 8 or 9 characters and is a mixture of numbers, uppercase and lowercase letters, and special characters. High: The password contains 10 to 20 characters and is a mixture of numbers, uppercase letters, lowercase letters, and special characters. 7. SINAMICS G120 SSID Wi-Fi Select the wireless network SSID of the SINAMICS G120 Smart Access and then enter the new Wi-Fi password to launch the connection. Enter the IP address (http://192.168.1.1 or https://192.168.1.1) to open the home page. Wireless network connection examples Windows 7/Windows 10 1. PC Click on the taskbar on your PC. 2. Select the target network and enter the wireless password to launch the connection. Android/iOS Wi-Fi Go to the Wi-Fi setting window on your tablet or smart phone, select the target network, and then enter the wireless password to launch the connection. Wi-Fi Resetting Wi-Fi configuration SINAMICS G120 SINAMICS G120 Wi-Fi When the SINAMICS G120 Smart Access is in power-on state, holding down the reset button for more than three seconds resets the Wi-Fi configuration of the SINAMICS G120 Smart Access to factory defaults. Wi-Fi (SSID): G120 smart access_xxxxxx xxxxxx MAC xxxxxx stands for the last six characters of the module MAC address. Wi-Fi Wi-Fi default password: 12345678 Default frequency channel: 1 Note Wi-Fi SINAMICS G120 Wi-Fi LED
/Wi-Fi LED Wi-Fi SINAMICS G120 Smart Access. Before pressing the reset button to reset the Wi-Fi configuration, make sure that the Wi-Fi communication LED on the SINAMICS G120 Smart Access lights up solid green/solid yellow or flashes green. The Wi-Fi configuration is reset successfully when the status of the Wi-Fi communication LED flashes yellow. After resetting Wi-Fi configuration, restart SINAMICS G120 Smart Access. Upgrading SINAMICS G120 Upgrading on the SINAMICS G120 Web page upgrades the firmware version of the module. Conventional upgrading 1. *.bin PC Download the target upgrade file (*.bin file) from the following Web site to your local drive (recommended on PC):
https://support.industry.siemens.com/cs/ww/en/ps/13225/dl 4. Proceed as follows to complete the upgrade. 5. Restart the module, clear the browser cache, and refresh your Web application. 2. SINAMICS G120 http://192.168.1.1 https://192.168.1.1 Additional information Access the SINAMICS G120 Web page: http://192.168.1.1 or https://192.168.1.1. Proceed as follows to perform the upgrade:
SINAMICS G120 Smart Access 10 After upgrading is successfully complete, the SINAMICS G120 Smart Access will restart automatically after the 10-second countdown time has elapsed. 3. Clear the browser cache and refresh your Web application. Basic upgrading Basic upgrading is applicable only when conventional upgrading fails. 1. *.bin PC Download the target upgrade file (*.bin file) from the following Web site to your local drive (recommended on PC):
https://support.industry.siemens.com/cs/ww/en/ps/13225/dl 2. Hold down the reset button when the module is in power-off state and then power on the module. 3. Open the following Web site specific for basic upgrading:
http://192.168.1.1/factory/basicupgrade.html You can watch the online tutorial for operating the module from the following link: www.Siemens.com/sinamics-accessories SINAMICS G120 Smart Access Operating Instructions For information about uploading self-created certificates, see SINAMICS G120 Smart Access Operating Instructions. ANATEL Statement in Portuguese about the ANATEL certificate:
Este equipamento no tem direito proteo contra interferncia prejudicial e no pode causar interferncia em sistemas devidamente autorizados. SINAMICS G120 2014/53/EU SINAMICS G120 Smart Access is in compliance with Radio Equipment Directive 2014/53/EU.
: or follow the link:
https://support.industry.siemens.com/cs/ww/en/ps/1 3225/man
: or follow the link:
https://support.industry.siemens.com/cs/ww/en/ps/1322 5/cert
: or follow the link:
https://support.industry.siemens.com/cs/ww/en/sc/2 067
: or follow the link:
https://www.automation.siemens.com/aspa_app/?lang=
en&showLayer=0 2018 Copyright 2018 Siemens Numerical Control Ltd., Nanjing A5E43332647-006 Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1)Lappareil ne doit pas produire de brouillage;
(2)Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This equipment complies with radio frequency exposure limits set forth by the Innovation, Science and Economic Development Canada for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux radiofrquences dfinies par la Innovation, Sciences et Dveloppement conomique Canada pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre le dispositif et l'utilisateur ou des tiers. Ce dispositif ne doit pas tre utilis proximit dune autre antenne ou dun autre metteur. NCC Statement in Traditional Chinese:
NCC FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RF exposure statement This equipment complies with radio frequency exposure limits set forth by the FCC for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders. This device must not be co-located or operating in conjunction with any other antenna or transmitter. IC Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.