MANUAL
(i) None. OVERVIEW: SENSMITTERS 1 OVERVIEW: SENSGATE 2 OVERVIEW: SENSGATE LED LAMPS 3 OVERVIEW: SENSATION 4 GETTING STARTED 5 ADDING NEW WI-FI SETTINGS TO YOUR SENSGATE 6 SETTING UP A SENS SYSTEM SETTING UP A SENS SYSTEM PART 1 7 SETTING UP A SENS SYSTEM PART 2 8 ADDING A SENSGATE TO THE SENS SYSTEM 9 ADDING A SENSMITTER TO THE SENS SYSTEM 10 DESK OCCUPANCY INSTALLATION INSTRUCTIONS 11 2 2 CLIMATE BACK M;DD:96:32:7D:24:AA;4 1 8 7 4 Model SSM-004 S/N 001-0002 Sigma Made in Sweden 5 BACK M;DD:96:32:7D:24:AA;4 8 7 Model SSM-004 S/N 001-0002 Sigma Made in Sweden 5 6 6 CONFERENCE 1 Light sensor 2 Temperature/Humidity sensor 3 PIR sensor 4 Air pressure sensor 5 LED 6 Reset button 7 Battery/ Battery holder 8 QR code 1 3 1 FRONT BACK 2 3 1 QR code 2 Power button 3 Mirco usb power outlet 2 SENSGATE DEPLOY FLOW:
1. Bluetooth LED lamp starts blinking BLUE and is ready for connection to receive registration ticket Error state : Bluetooth LED lamp starts blinking RED if the hub detects any error when creating the connecting to the deloy app device 2. Bluetooth LED lamp is constantly BLUE. Connection between sensgate and deploy app device done OK. 3. Bluetooth LED lamp is GREEN (Registration ticket received OK through BT and validated OK) Error state: Verication of security token and registration ticket fails, Bluetooth LED turns RED 3.5: Wi-Fi LED lamp is BLUE when the sensgate tries to connect to WiFi 4. Wi-Fi LED lamp turns GREEN when the sensgate has created a WiFi connection Error state Wi-Fi LED lamp turns RED when theres an rror when connecting to WiFi (e.g. wrong key or not found the SSID, etc.) When theres a problem with inbox/outbox connection, the gateway lamp turns RED 5: Gateway lamp turns GREEN when the setup is OK Any change of state for any LED, times out after 8 seconds. SENSMITTER DEPLOY FLOW:
1. The sensmitter registration LED lamp turns GREEN when the registration is OK Error state: If the registration doesnt go through, the sensmitter registration LED lamp will turn RED TROUBLESHOOTING 1. Press the power button for 8 seconds in order to restart it. The LED lamps will turn red and shut down after some seconds. Restart process takes around 2-3 minutes before the sensgate is up and running again 2.2. To do a hard reboot, press the power button for approximately 15 seconds. The LED lamps will rst turn BLUE and then RED, which initialize the reboot sequence. Restart process takes around 2-3 minutes before the sensgate is up and running again 1 4 2 3 1 Bluetooth LED lamp 2 Wi-Fi LED lamp 3 Gateway LED lamp 4 Sensmitter registration LED lamp 3 INTRODUCTION AppIoT is the application that handles your network of sensors. With AppIoT you can analyze and process enor-
mous amounts of data in real-time. The information is displayed in the user interface below and can be connected to maintenance systems and BI solutions. INSTALLATION AND TEMPLATES During the installation, templates are used in order to congure each individual sensmitter. When conguring a sensmitter, a conguration could be: how often it will report, and in which range of values that it report. For exam-
ple if we have a sensmitter that has a temperature sensor, this sensmitter could then use a template called
"indoor", which would enable the sensmitter to report the temperature once every hour. In this wa In this way, the user simply select the template and does not have to worry about the underlying logic and set-
tings. These templates can also specify what rules to apply. Its possible to have a rule that says that if the indoor temperature exceeds 26 degrees Celsius, a work order is created. This means that an installation could be done in a couple of minutes if templates are used during the installation 4 5 2 1 3 9 7 8 6 1 Dashboard Overview pane of all installations where the user can see active events, caluculated values and pinned graphs 2 Location Is the geographical location of the installation. Here the user is able to set the name of the location such as home or ofce 3 Sub-location Is the sub-location to the main location. A sub-location could be oor 1 or area A 4 Settings menu Is where the user is able to set up/add locations, tags templates etc. 5 Calculated values Is the button which enables the user to add calculated values to locations and sensmitters 6 Event history Shows all events , such as triggers and alarms. 7 Location map setting Is where the user is able to pinpoit the location on a map and where they can add a oorplan to the location 8 Location map Shows the location of the system on a map 9 User menu Is the menu which alows the user to log out from AppIoT 4 1. To get started with your SENS kit, you rst need to download the SENS app from the Google play store. 2. Find the app by searching for SENS (made by Sigma AB) 3. Once the app is downloaded, begin by starting up the app by clicking the SENS app icon Play Store Sigma AB Sens the world around you 1 2 SENS 3 5 In order to add new wi- settings to an already deployed sensgates, do the following:
1. Plug your sensgate to a wall outlet. 2. Press the sensgate button for 2 seconds, a blue LED should start blinking. 3. Press the 3 dots in the SENS app and press settings. Here you will be able to to add a Wi-Fi network to your SENS system. 4. 4. Start by clicking the add new network conguration button. Here your have to enter the network congura-
tions of the network that you want to connect to your SENS system. Once this is done, prsss Send to gateway and scan the QR code of the sensgate.
*Note The sensgate should be installed in the celling in order to get best coverage and not used closer than 20 cm to the human body 2 Seconds 1 2 3 4 6 In order to set-up your SENS system, you rst have to add a Wi-Fi network to your SENS system. 1. Start up the SENS app by clicking the SENS icon. 2. Click the 3 dots in the top right corners to access settings. 3. Under settings you will be able to to add a Wi-Fi network to your SENS system. 4. Start by clicking the add new network conguration button. Here your have to enter the network congura-
tions of the network that you want to connect to your SENS system Once this is done, you can go back to the Login screen. Start by logging in with the given credentials found in the Once this is done, you can go back to the Login screen. Start by logging in with the given credentials found in the email. When this is done, you are able to set up your SENS system. 1 3 2 4 7 1. Start by adding a system location, which can be found under settings. 2. Once a location is added, you can add sensmitters and sensgates. Start by clicking the Register gateway +
or Register device button. 3. Sscan the QR code of your device, which you can nd on the backside of your device. 4. 4. After the QR code has been scanned, you will be directed to the set-up page where you can congure your device. On this page you will be able to set templates (pre-congured settings),settings (your own custom made settings), oor plan, position and tags ( used for analytics) 1 2 3 8 4 1. Plug your sensgate into an outlet in order to turn on the device. Wait approx.1 minute to boot up the device 2. Press the power button for 2 seconds in order to put the sensgate in deploy mode. The Bluetooth LED lamp will start blinking BLUE (nformation about the different LED lamps can be found under Overview: Sensgate LED lamps) 3. Start up the SENS app and choose the location where you want to add your sensgate. 4. 4. Scan the QR code on the backside of the sensgate and nalize the setup buy conguring your sensgate with the settings that you desire 2 Seconds 1 2 Test Installation Test Installation Sigma Connectivity Made in Sweden Model SSM-004 S/N 001-0002 FCC xxxxx-SSM004 IC xxxxx-SSM004 G;12:34:56:78:90:12;4 3 4 9 10 1. In order to measure correctly, the desk occupancy sensmitter should be installed as shown in the picture below (top view of the sensmitter should be facing the edge of the desk) 2. The desk occupancy sensmitter should be placed in the center of the desk and approximately 60cm from the edge of the table (under the table as seen in the picture) and approximately 70cm above the oor to measure someone who is sitting (when standing, the height should be increased) 3. Under above circumstances, the desk occupancy will be able to detected presence with a 1,5m eld of view
(width) 4. Desk occupancy sensmitters will be able to detect if desks are occupied or not, whether you are standing or sitting 60cm 70cm 2 4 1 1,5m 3 11