Non-contact physiological signal detector SSR2D1P14AAPBXXC Smart Pig Raising Management Systems NEW VERSION Standard Products Version: A1 Date 2019-04-24 Overview SSR2D1P14AAPBXXC is a non-contact physiological signal detection system. The respiratory rate of pigs was measured with an accuracy of 10%, and the measurement distance was 1.0M. Pig growth period and pregnancy state breathing table see (Figure 1). The detection frequency band of the radar device frequency operates in the 2.4~2.5 GHz ISM band. It is used on the SIL radar sensor with a power of 1/100 WIFI. The SIL Radar device can be used with thermal imaging devices to detect animal health and behavior. The unit is designed to meet the standard f ANSI / AAMIES60601-1 and IEC / EN60601-1 3rd editions and meets international medical standards (2 x MOPP).
(Figure 1) Product specifications Item Frequency Range Antenna connector Transmit power Antenna gain Antenna angle Communication interface Network function Operating voltage Working current Operating temperature Body size (WxLxH) weight Switch Protection level Specifications 2439MHz~2460MHz ISM Band 3.5MM SMA * 1 32 dBm 14dBi (1dB) 60 degree Two sets of RJ45 serial port // TCP/IP (data transmission) Built-in 5 ports network switch 80~264VAC//47~63Hz; 0.75A/115VAC ;0.5A/230VAC 150mA ( 16.5W ) 0C ~ 70C 22 x 15 x 5.6 cm (2mm) 2.85Kg Waterproof IP65 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Switch and interface 1. Power input: 80~264VAC//47~63Hz; 0.75A/115VAC ;0.5A/230VAC 2. Power switch: O=OFF, I=ON 3. Communication port: RJ45 *2. Support 10/100 Mbps 4. Antenna connector: 3.5mm SMA (1M Coaxial Cable) System details 1. Equipment system (IP65 enclosure)* 1 2. Antenna 14dBi * 1 3. Antenna clip * 1 4. Coaxial cable (1m)* 1 5. Power cord (1.5 m)* 1 Antenna installation Precautions 1. Reduce the effects of electromagnetic waves, please use them properly. 2. The use of low-power RF motors shall not affect flight safety, if interference is found, it shall be immediately deactivated. 3. All parts must be replaced by trained and qualified technicians 4. This instrument may not be modified without the consent of the original manufacturer. Description function principle An oscillator transmits signals through the antenna unit. Then the biological reflection signal is injected back into the oscillator make it injection locking state, and the reflected signal has a Doppler shift characteristic. At this time, the output signal of the oscillator can be amplified by the simple frequency demodulation, and the Doppler frequency shift signal can be amplified and the phase noise can be removed. Because of the signal has small bandwidth of the injection locking operation, most of the channel noise can be filtered and the signal-to-noise ratio for boosting the frequency shift exceeds 100dB. It is very suitable for detecting the weak vital signs of life in the Life Detector. Such as breathing, heartbeat, pulse, etc. SIL , Taiwan Tel. +886-2-8512-3222 Fax. +886-2-8512-1898 Date of release: June 2019 Non-contact physiological signal detector SSR2D1P14ACHBHXC NEW VERSION Standard Products Version: A2 Date 2019-04-21 Table of Contents 1 Overview 2. Product Features 3. Input terminal definition 4. System block diagram 5. Mechanical chart 6. Installation instructions (effective antenna detection range) 7. Precautions 1. Overview SSR2D1P14ACHBHXC is a Non-contact Physiological Signal Detector system to detect human heart rate and respiratory rate simultaneously with working distance up to 2.5M(depending on Athena design). The detection of heart rate and respiratory rate is applying for SIL Radar sensor working at 2.4GHz ISM frequency by 1/100 WIFI power level. The SIL Radar technology is also for detecting human and animals trace and at the location. Power deign meets the standard f ANSI/AAMIES60601-1 and IEC/EN60601-1 Version 3 to meet International medical standards (2 x MOPP). Product Features mmediacy The All-in-one system can obtain humans 3 major physiological signals from one device in a short period. The entire system reduce out-of-synchronization problem for 3 major signals from different devices, as well as the complexity to set up 3 different devices in one location. It helps the care staffs in the nursing organization to raise their efficiency and immediacy to give the first aids to patients in danger conditions. Sensitivity & Accuracy The system outputs ultimate sensitivity by detecting only 1mm vibration from human physiological signals. For any living body, it detects directly the heart rate and respiratory rate for accuracy approximately 90%. The error value of respiratory rate is 3 R.R and of heart rate is 7 bpm. To detect if any presence of living body takes no longer than 30 seconds (living body arrives in 15 seconds and departures in 30 seconds at signal range). System Expandability The system has a built-in high-speed Ethernet interface that automatically detects and adjusts the 10/100Mbps connection rate. Transmission rate up to 1GbpsCompatible with IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE 802.3az EEE standards. Easy to install and play Actual installation 2. Product Specification Item Frequency range Athena Interface 2439MHz~2460MHz 3.5MM SMA *1 PCBA Emission Power Antenna Gain 32 dBm 14dBi Specification Communication Interface RJ45 connector // TCP/IP(for data transfer) *2 Display Interface HDMI Operating Voltage/Noise 80~264VAC//47~63Hz; 0.75A/115VAC ;0.5A/230VAC Operating Current 110V AC 150mA ( 16.5W ) Operating Temperature 0C ~ 70C Dimension(WxLxH) Weight 600 x 600 x 75mm 4.5 Kg 300g 2.1 SIL Radar Module Pin Define Pin pitch: 1/ 2.54mm Dimension: 55 55 7.5 mm (0.2mm) Pin# Description 1 2 3 4 5 NOTE Vcc GND I2C-SDA I2C-SCK GND In/Out POWER POWER I/O I/O Comment supply voltage (+12 V) Analog Ground Digital Signal Digital Signal POWER Analog Ground 3. Input Terminals 1. PowerInput: 80~264VAC//47~63Hz; 0.75A/115VAC;0.5A/230VAC 2. RJ45Connector:Support10/100MbpsLANNetwork 3. PowerSwitch 4. System block diagram 1. Power Source 2. SIL Radar Module 3. Base Band 4. Ethernet HUB 5 ports 10/100Mbps 5. Antenna( Gain 14 dBi) 5. Mechanical chart (UNIT: mm) 6. Installation Notes Radar antenna effective detection area (green block on the right) Centering on the shuifen point (best position point) The effective detection range is:
Each side of the shuifen point is 15 cm, and the head is extended to 25 cm. As shown on th Radar installation requirements description When the subject is lying on the bed, the radiation center of the radar antenna needs to be the best position for the water hole of the person. As shown below 7. Precautions 1. Reduce the effects of electromagnetic waves, please use them properly 2. Avoid measurement and error caused by conversation and eating during measurement 3. The installation distance between the two devices must be one meter 4. There should be no obstacle isolation between the person to be tested and the device. 5. All parts must be replaced by trained and qualified technicians 6. This instrument may not be modified without the consent of the original manufacturer. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. SIL , Taiwan Tel. +886-2-8512-3222 Fax. +886-2-8512-1898 Date of release: June 2019 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. SIL , Taiwan Tel. +886-2-8512-3222 Fax. +886-2-8512-1898 Date of release: June 2019