nano Professional Balance Charger / Discharger Instruction Manual
[Version 1.20]
TABLE OF CONTENTS INTRODUCTION SPECIAL FEATURES WARNING AND SAFETY NOTES PROGRAM FLOW CHART OPERATION OPERATING PROGRAM CHARGING PROGRAM BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY METER BATTERY RESISTANCE METER WARNING AND ERROR MESSAGE USING THE CHARGE CONTROL SOFTWARE CHARGE MASTER THE SET CONTAINS SPECIFICATION CONFORMITY DECLARATION COMMONLY USED TERMS WARRANTY AND SERVICE INTRODUCTION Congratulations on your choice of SkyRC B6 nano. The operation and UI has been optimized to be hassle-free for basic usage. Being app-enabled, the user experience can be largely expanded, more features and advanced settings are provided within the free app. Multiple safety protections are implemented, such as, reverse polarity protection, charging time limit, charging capacity limit. The operation of a multi-chemistry battery charger does require certain knowledge on the part of the user. Please BE SURE to read these INSTRUCTIONS, WARNING and SAFETY NOTES before you use the charger. It can be dangerous, fire or explosion, if misoperation happens. We hope you have years of pleasure and success with your new battery Charger. THESETCONTAINS B6 nano 01 INTRODUCTION Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist!
DC Input Socket DC 9-32V LCD Display Decrease Button Start / Stop Button Increase Button Output Socket Balance Lead Socket 02 B6 nano SPECIAL FEATURES Smart Phone Control (both iOS and Android) The free SkyCharger App unleashes tons of features and advanced settings, which tremendously expands the user experience of B6 nano. Internal Independent Lithium Battery Balancer With the balance lead connected, B6 nano will balance your lithium batteries while charging or discharging. Adaptable to Various Types of Batteries B6 nano is adaptable to various types of batteries, such as LiPo, NiMH, Pb and the lastest LiHV batteries. Fast and Storage Mode for Lithium Battery With highly optimized software, the preset modes can meet varies charging purposes, 'fast' charge reduces the duration of charging, whereas 'storage' controls the terminal voltage of your battery to the best state for storing while protects its lifespan. Delta-peak Sensitivity for NiMH/NiCd Delta-peak sensitivity for NiMH/NiCd battery: the automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically. Cyclic Charging/ Discharging 1 to 5 cyclic and continuous process of charge> discharge or discharge> charge is operable for battery refreshing and balancing to stimulate the battery's activity. Capacity Limit*
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value. Processing Time Limit*
You can limit the maximum process time to avoid any possible defect. Terminal Voltage Control (TVC)*
Experienced users or experts can set charge or discharge terminal voltage according to their needs.
*This feature is available in the SkyCharger App only. B6 nano 03 WARNING AND SAFETY NOTES These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual. Keep the charger well away from dust, damp, rain, heat, direct sunshine and vibration. Never drop it. The allowable DC input voltage is 9~32V DC This charger and the battery should be put on a heat-resistant, noninflammable and nonconductive surface. Never place them on a car seat, carpet or similar. Keep all the inflammable volatile materials away from operating area. Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger. If the program is set up incorrectly, the battery and charger may be damaged .It can cause fire or explosion due to overcharging. Standard Battery Parameters Nominal Voltage Max Charge Voltage Storage Voltage Allowable Fast Charge Min. Discharge Voltage LiPo LiIon LiFe LiHV NiCd NiMH Pb 3.7V/cell 3.6V/cell 3.3V/cell 3.7V/cell 1.2V/cell 1.2V/cell 2.0V/cell 4.2V/cell 4.1V/cell 3.6V/cell 4.35V/cell 1.5V/cell 1.5V/cell 2.4V/cell 3.8V/cell 3.7V/cell 3.3V/cell 3.85V/cell n/a n/a n/a 1C 1C 4C 1C 1C-2C 1C-2C 0.4C 3.0-3.3V/cell 2.9-3.2V/cell 2.6-2.9V/cell 3.1-3.4V/cell 0.1-1.1V/cell 0.1-1.1V/cell 1.8V/cell Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode. WARNING AND SAFETY NOTES Never attempt to charge or discharge the following types of batteries. A battery pack which consists of different types of cells (including different manufacturers) A battery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMh, LiPo or Gel cell (Pb, Lead acid). A faulty or damaged battery. A battery fitted with an integral charge circuit or a protection circuit. Batteries installed in a device or which are electrically linked to other components. Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process. Please bear in mind the following points before commencing charging:
Did you select the appropriate program suitable for the type of battery you are charging?
Did you set up adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can be wired in parallel and in series, i.e. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series). Have you checked that all connections are firm and secure?
Make sure there are no intermittent contacts at any point in the circuit. Charging During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is calculated by multiplying charge current by charge time. The maximum permissible charge current varies depending on the battery type or its performance, and can be found in the information by the battery manufacturer. Only batteries that are expressly stated to be capable of quick-
charge are allowed to be charged at rates higher than the standard charge current. Connect the battery to the terminal of the charger: red is positive and black is negative. Due to the difference between resistance of cable and connector, the charger can not detect resistance of the battery pack, the essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross-section, and high quality connectors which are normally gold-
plated should be fitted to both ends. Always refer to the manual by battery manufacturer about charging methods, recommended charging current and charging time. Especially, the lithium battery should be charged according the manufacturer strictly. instruction provided by the charging WARNING AND SAFETY NOTES Attention should be paid to the connection of lithium battery especially. Do not attempt to disassemble the battery pack arbitrarily. Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same. The voltages imbalance may cause fire or explosion .Lithium battery is recommended to charge in series. Discharging The main purpose of discharging is to clean residual capacity of the battery, or to reduce the battery voltage to a defined level. The same attention should be paid to the discharging process as charging. The final discharge voltage should be set up correctly to avoid deep-discharging. Lithium battery can not be discharged to lower than the minimum voltage, or it will cause a rapid loss of capacity or a total failure. Generally, lithium battery doesn't need to be discharged. Please pay attention to the minimum voltage of lithium battery to protect the battery. Some rechargeable batteries have a memory effect. If they are partly used and recharged before the whole charge is accomplished, they remember this and will only use that part of their capacity next time. This is a memory effect. It is said that NiCd and NiMH batteries are suffering from memory effect. NiCd has more memory effect than NiMH. OPERATING PROGRAM 1. Connect the charger to DC power supply. Important Notice To take advantage of B6 nanos full power capability, the power source should be 9-32V DC, and output power should be capable of 250W or higher. Low quality DC power source may damage your B6 nano charger. We recommend you to choose SKYRC 380W Power Supply. Connect the charger to Pb battery. 2. Insert the battery to the charger LiPo Battery Battery Type Battery Cells BATTERY TYPE:
CELLS:
Bluetooth Mode MODE:
BALANCE CHARGE Current CURRENT:
Battery Voltage VOLTAGE:
Capacity CAPACITY:
A V mAh
%
Percentage Battery Type: select the chemistry of the battery to be processed. Cells: select how many cells of the battery to be processed. Mode: select which process the charger will run. Current: select the current of charge/ discharge process. Voltage: display the voltage of the connected battery. Capacity: calculate the electric charge transferred. Percentage: display the remaining capacity of the connected battery. Bluetooth: indicate the charger is connected with mobile device. 3. Battery Type Setting Press button, the battery type will blinking. Then Press or button to select the correct battery type. 4. Battery Cells Setting Press button, the battery cells will blinking. Then Press or button to select the correct battery cells. 5. Charging Mode Setting Press button, the mode will blinking. Then Press or button to select the charging mode. BATTERY TYPE:
CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
A V mAh BATTERY TYPE:
CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
A V mAh BATTERY TYPE:
CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
A V mAh
%
%
%
6. Charge Current Setting Press button, the current will blinking. Then Press or button to select the charge current. 7. Program Start Press and hold button for 3 seconds to start the program. BATTERY TYPE:
CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
A V mAh BATTERY TYPE:
CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
A V mAh
%
%
8. Program Stop During the charging process, press button to stop the charging process. 9. Program Complete When the charging process finished, and 5 beeps audible sound will be heard. CELLS:
MODE:
BALANCE CHARGE CURRENT:
VOLTAGE:
CAPACITY:
%
A V mAh OPERATING PROGRAM Charging Program Depends on different battery type, the operation programs are different. Batt Type Operation Program Description CHARGE This charging mode is for charging LiPo/LiFe/LiIon/LiHV battery in normal mode. DISCHARGE This mode is for discharging LiPo/LiFe/LiIon/LiHV battery. LiPo Lilon LiFe LiHV NiMH NiCd Pb STORAGE This program is for charging or discharging lithium battery which will not be used for long time. FAST CHG The charging capacity may be a bit smaller than normal charging but the process time will be reduced. BAL CHARGE This mode is for balancing the voltage of lithium-polymer battery cells while charging. CHARGE The charger will charge NiMH and NiCd batteries using the charge current set by the user. DISCHARGE This mode is for discharging NiMH/NiCd battery. CYCLE 1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for battery refreshing and balancing to stimulate the battery's activity. CHARGE This mode is for charging Pb battery. DISCHARGE This mode is for discharging Pb battery. WARNING AND ERROR MESSAGE In case of an error the screen will display the cause of error and emit an audible sound. No battery attached. The cell number is wrong. The battery voltage is higher than the maximum voltage which the user sets when charging in balance mode. Balance port voltage error. Battery is full. Incorrect polarity connected. The internal temperature of the unit goes too high. Input voltage less than 9V. Input voltage higher than 32V. The battery capacity is more than the maximum capacity which the user sets. The charging time is longer than the maximum charging time which the user sets. CONTROLLING THE CHARGER USING THE APP The Bluetooth 4.0 connectivity allows the user to control and monitor the B6 nano comfortably through an app on a portable device such as smart phone, iPad, or iPhone. The iOS app can be downloaded from iTunes store, the Android app from Google Play Store. Operation of the app is self-
explanatory and the same on iOS and on Android. Explicit pairing is not required; after download and installation just activate Bluetooth on your mobile device and launch the App. B6 nano and your device will establish Bluetooth connection automatically. Scan the QR code on the right to download the SkyCHARGER App. Scan with your Smartphone to download. OPERATION 1. Connect the power cord to B6 nano, then plug the power cord into the outlet
(100~240V AC, 50/60Hz). Connect the batteries to the corresponding channels. Enable Bluetooth function on your mobile device and launch the SkyCHARGER. 2. 3. 1). Launch the App and set the password (Please do not set the password to 5793 which is the reserved for the system using) Revo 15:53 Ver: 1.7.1 Revo 15:53 Revo BACK 15:53 Edit Password Battery Type Battery Cells Operation Mode SkyCHARGER 4 5 6 LiPo Your password must have at least 4 digits Alert BAL.CHARGE OK LiIon LiFe Please setup your password CHARGER Ignore DISCHARGER OK NEXT SCAN TO GO HOME PROGRAM SYSTEM CONTROLLING THE CHARGER USING THE APP How to reset password B A T T / P R O G R A M S Y S T E M S E T T I N G - >
Press ENTER button START ENTER D C S U P P L Y : O F F C H A : 5 0 C H B : 5 0 Press DEC twice L o a d F a c t o r y S e t E N T E R Press and hold the ENTER button for 3 seconds to reset password. 2). Operation Steps for Charging(Take 6S LiPo battery for example) Connect the batteries to the corresponding channels,select battery type, cells. Press NEXT to set the proper charge current. Revo 15:53 Battery Type Battery Cells Operation Mode Revo Back Battery Type LiPo 4 5 6 LiPo LiIon LiFe BAL.CHARGE CHARGER DISCHARGER NEXT SCAN TO GO HOME PROGRAM SYSTEM 15:53 Revo 15:53 More Battery Cells Operation Mode 6 BAL.CHARGE Charge Current 1.1A 1.2A 1.3A 1.4A 1.5A 1.6A 1.7A START Balance Charge Battery Type LiPo Current 4.65 A Capacity 1500 mAh Battery Fuel Gauge 89 %
Battery ID 0D0E07D5 Battery Cells 6 Voltage 24.58 V Duration 00:10:07 Charger Temperature 50 122 F No. of charger 1 C 4.09 V 4.10 V 4.10 V 4.09 V 4.10 V 4.10 V STOP CONTROLLING THE CHARGER USING THE APP 3). How to Use Memory Program Revo 15:53 Revo 15:53 Revo BACK 15:53 Edit Battery Type Battery Cells Operation Mode 4 5 6 LiPo LiIon LiFe BAL.CHARGE CHARGER DISCHARGER Save Enter into PROGRAM interface Set battery type, cells and working modes Revo 15:53 Revo 15:53 LiPo BAL.CHARGE Cells 6 Charge Curretn 5.0A Voltage4.20V LiPo BAL.CHARGE Cells 6 Charge Curretn 5.0A Voltage4.20V Battery Type Battery Cells Operation Mode 4 5 6 LiPo LiIon LiFe BAL.CHARGE CHARGER DISCHARGER NEXT SCAN TO GO HOME PROGRAM SYSTEM Press PROGRAM button Revo Cancel 15:53 Edit Save LiPo 6Cell BAL.CHARGE >
Charge Current 5.0 A Voltage Cut-Off 4.20 V START EDIT CANCEL Press to save the program after set the charge current and voltage cut-off HOME PROGRAM SYSTEM Memory program setting finishes. HOME PROGRAM SYSTEM PressSTARTbutton to start charge PressEDIT button to change the setting CONTROLLING THE CHARGER USING THE APP 4). System Setting Revo 15:53 Battery Type Battery Cells Operation Mode 2 3 4 5 6 LiPo LiIon LiFe BAL.CHARGE CHARGER DISCHARGER NEXT SCAN TO GO Revo 15:53 Revo 15:53 Safety Timer 120 Min Capacity Cut-Off 5000 mAh Key Beep Buzzer Temperature Cut-Off 122 50 C F Change Password
>
Rest Time Between Cycle Charge Discharge 10 Min DC Input Low Cut-Off 11.0 V Balance Port Enable HOME PROGRAM SYSTEM HOME PROGRAM SYSTEM HOME PROGRAM SYSTEM Enter into System Setting 5). SCAN TO GO A very unique feature of B6 nano is SCAN TO GO (automatically charging system). As the range of battery types and capacity becomes more and more, each battery requires its own dedicated charging process. It is easy to set up the charger incorrectly for a specific type of battery, resulting damage the battery or even cause accident. The revolutionary SCAN TO GO provides a solution to this problem by allowing the user to assign a QR Code which contains all the relevant data for the battery for charging or discharging. The user can create a unique QR Code by using SkyCharger apps. Print it and paste it on the battery. Using your smart phone and launch SkyCharger App. Since all the essential information is stored in the QR Code. All you need to do is press the Scan button, and the charge or discharge process will start automatically. CONTROLLING THE CHARGER USING THE APP How to print QR code Revo 15:53 Revo 15:53 Revo 15:53 LiPo BAL.CHARGE Cells 6 Charge Curretn 5.0A Voltage4.20V LiPo BAL.CHARGE 6S Cells 6 Charge Curretn 5.0A Voltage4.20V 5.0A Press the QR code Revo 15:53 Save the QR code to Gallery Revo 15:53 Gallery Open Gallery A 0
. 5 S 6 You can print it from your mobile phone or send the QR code image to computer to print it out. Attach the printed QR code to the battery Revo BACK 15:53 Select the QR code and open it Scan to charge Revo 15:53 Battery Type Battery Cells Operation Mode 2 3 4 5 6 LiPo LiIon LiFe BAL.CHARGE CHARGER DISCHARGER NEXT SCAN TO GO Align QR Code/Barcode within frame to scan HOME PROGRAM SYSTEM PressSCAN TO GO Scan to launch the program SPECIFICATION DC Input Voltage : 9-32V Display Type: LCD Case Material: Plastic Controls: Three Buttons Case Size: 76x85x37mm Weight: 130g External Port: 2-6S Balance Socket-XH, Battery Socket, DC Input Delta Peak Detection for NiMH/NiCd: 3-15mV/cell / Default: 4mV/cell Charge Voltage: NiMH/NiCd: Delta peak detection
LiPo: 4.18-4.25V/cell LiIon: 4.08-4.2V/cell LiFe: 3.58-3.7V/cell LiHV: 4.25-4.35V/cell Balance Current: 1000mA/cell Max Reading Voltage Range: 0.1-26.1V/cell Battery Types/Cells: LiPo/LiIon/LiFe/LiHV: 1-6cells
Battery Capacity Range: NiMH/NiCd: 100-50000mAh NiMH/NiCd: 1-15cells Pb: 2-20V LiPo/LiIon/LiFe/LiHV: 100-50000mAh
Pb: 100-50000mAh Charge Current: 0.1A-15.0A Safety Timer: 1-720minutes off Charge Wattage: 320W Discharge Current: 0.1A-3.0A Discharge Cut-off Voltage: NiMH/NiCd: 0.1-1.1V/cell LiPo: 3.0-3.3V/cell LiIon: 2.9-3.2V/cell LiFe: 2.6-2.9V/cell LiHV: 3.1-3.4V/cell Pb: 1.8V Discharge Wattage: 5W Balance Cells: 2-6 cells Charge Method: CC/CV for lithium types and lead (Pb) batteries Delta-peak Sensitivity for NiMH/NiCd. REGULATORY INFORMATION B6 nano satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B: 2016. For CE directives:
The product has been tested to meet the following technical standards:
EN 55014-1:2006+
A1:2009+A2:2011 EN 55014-2:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 300 328 V2.1.1 EN 301489-1 EN 301489-17 EN 62479 EN 60950-1 Electromagnetic Compatibility- Requirements for household appliances, electric tools and similar apparatus- Part 1: Emission Electromagnetic Compatibility- Requirements For Household Appliances, Electric Tools And Similar Apparatus- Part 2: Immunity Product Family Standard Electromagnetic Compatibility (EMC) Part 3-2:
Limits for harmonic current emissions(Equipment input current up to and including 16A per phase) Electromagnetic Compatibility (EMC) Part 3-3:
Limitation of voltage supply systems for equipment with rated current16A Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques;
Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements. Part 17: Specific conditions for Broadband Data Transmission Systems. Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 Ghz). Information Technology Equipment-Safety- Part 1:
General Requirements This symbol means that you must dispose of electrical from the General household waste when it reaches the end of its useful life. Take your charger to your local waste collection point or recycling centre. This applies to all countries of the European Union, and to other European countries with a separate waste collection system. COMMONLY USED TERMS Commonly used terms Final charge voltage: the voltage at which the battery's charge limit (capacity limit) is reached. The charge process switches from a high current to a low maintenance rate (trickle charge) at this point. From this point on further high current charging would cause overheating and eventual terminal damage to the pack. Final discharge voltage: the voltage at which the battery's discharge limit is reached. The chemical composition of the batteries determines the level of this voltage. Below this voltage the battery enters the deep discharge zone. Individual cells within the pack may become reverse polarized in this condition, and this can cause permanent damage. A, mA: unit of measurement relating to charge or discharge current.1000 mA = 1 A
(A=Ampere,mA=Milliampere) Ah, mAh: unit of measurement for the capacity of a battery (Amperes x time unit; h
= hour). If a pack is charged for one hour at a current of 2 A, it has been fed 2 Ah of energy. It receives the same quantity of charge (2 Ah) if it is charged for 4 hours at 0.5 A, or 15 minutes (=1/4 h) at 8 A.
'C'-rating: Capacity is also referred to as the 'C' rating. Some battery suppliers recommend charge and discharge currents based on the battery 'C' rating. A battery's '1C' current is the same number as the battery's rated capacity number, but noted in mA or amps. A 600mAh battery has a 1C current value of 600mA, and a 3C current value of (3 x 600mA) 1800mA or 1.8A. The 1C current value for a 3200mAh battery would be 3200mA (3.2A). Nominal voltage(V): The nominal voltage of the battery pack can be determined as follows;
-.NiCd or NiMH: multiply the total number of cells in the pack by 1.2. A 8-cell pack will have a nominal voltage of 9.6 volts (8x1.2).
-.LiPo: multiply the total number of cells in the pack by 3.7. A 3-cell LiPo wired in series will have a nominal voltage of 11.1 volts (3x3.7).
-.LiIo: multiply the total number of cells in the pack by 3.6. A 2-cell LiIo wired in series will have a nominal voltage of 7.2 volts (2x3.6).
-.LiFe: multiply the total number of cells in the pack by 3.3. A 4-cell LiIo wired in series will have a nominal voltage of 13.2 volts (4x3.3). If the nominal voltage of the battery is not printed on the battery's label, consult your battery manufacturer or supplier. Do not guess the rated voltage of battery. WARRANTY AND SERVICE Liability exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated. We are unable to ensure that you follow the instructions supplied with the charger, and we have no control over the methods you employ for using, operating and maintaining the device. For this reason we are obliged to deny all liability for loss, damage or costs which are incurred due to the incompetent or incorrect use and operation of our products, or which are connected with such operation in any way.Unless otherwise prescribed by law, our obligation to pay compensation, regardless of the legal argument employed, is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred. Warranty and service We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase. The warranty only applies to material or operational defects, which are present at the time of purchase. During that period, we will repair or replace free of service charge for products deemed defective due to those causes. This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modification or as a result of failure to observe the procedures outlined in this manual. Note:
1. 2. The warranty service is valid in China only. If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for processing guarantee claims overseas. Due to high shipping cost, complicated custom clearance procedures to send back to China. Please understand SkyRC can't provide warranty service to overseas end user directly. If you have any questions which are not mentioned in the manual, please feel free to send email to info@skyrc.cn 3. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Manufactured by SKYRC Technology Co., Ltd. www.skyrc.com RoHS FCC ID: REY-B6NANO All specifications and figures are subject to change without notice. Printed in China 2018.04