Instruction & Safety Manual Death or Injury can occur from improper use or care. Ensure system is connected to base station and will remain within signal range before use and during use. Remove sling from service and contact an authorized repair station if:
Failure to ensure proper functioning of system can result in undetected damage and sling failure. System will not connect to base station. System alert activates indicating a potential overload condition. This product contains lithium metal batteries. Under extreme circum-
stances these batteries may catch fire or explode. Do not tamper with the Check-Fast Plus Sling Sensor. For additional important safety information, inspection, removal and repair follow Slingmax Guidelines, ASME B30.9, WSTDA RS-HP-1 and Cordage Institute CI 1905 standards. Check-Fast Plus - User Information Check-Fast Plus alerts the user when the sling is overloaded or damaged. Each base station can monitor up to 50 slings at one time. Typical range is 500ft. An alert will be sent to the base station if the Check-Fast Plus system detects an overload. In addition, text alerts (SMS) and email alerts can be enabled. Set up of Check-Fast Plus Application Login to the Check-Fast Plus application with your username and password. If you forgot your password click Forgot Password?
and enter the phone number the device was registered with. A new password will be sent to that phone number. To set up your site click the SETTINGS tab. Click Edit Site Info. The EDIT SITE INFO screen will appear. Enter your job site name and address. Click Save to save changes. Click on the Add New User tab to add users. These users will have the ability to log into the Check-Fast Plus application. Add the users info and toggle the SMS Alerts to enable text message notication for damage detected by Check-Fast Plus System. Alerts will include:
Site info Date and time Serial number of the sling Multiple slings can be monitored simultaneously from the LIFT Screen. Or individually from by clicking on the sling. Slings will show status, signal strength, and overload indication. Green status indicates the sling is within its normal range of use. Red indicates overload. the lift immediately!
If indication of overload is detected or observed stop Before Each Use Sling users shall be trained Do not use this sling unless you are properly trained. Follow all instructions and warnings in this manual and in the Twin-Path user manual. DEATH or INJURY can occur from improper use or care. Check tag to conrm that sling is adequately rated for the load. Inspect sling for damage in accordance with the Twin-Path user manual. Inspections shall be completed before each use and must include all items being used. Periodic inspections shall be completed at least annually or more frequently depending on service. Periodic inspections shall be documented. Refer to ASME B30.9 and manufacturer recommendations Care Login into the Check-Fast Plus application with your user name and password. Begin pairing the slings by clicking the Scan Slings button on the LIFT tab. Slings within a 500ft radius should appear. Once sling(s) are paired they will be added to your inventory. Sling(s) in inventory can be selected to show additional information. Use Determine the weight of the load. Check the tag to conrm that the sling is rated adequately for the load in the manner or hitches that it will be used. Refer to load angle, choke angle and other relevant charts. Slings should be kept away from possible mechanical damage, corrosion, dust, grit and temperatures above 180 degrees F. To clean sling: use mild soap and water and allow to air dry before storing. Do not machine wash or dry. Repair Field repair is not permitted. Return sling to a Slingmax Dealer for repairs. Troubleshooting Sling will not connect to base station. 1. 2. 3. Ensure base station is plugged into the computer. Ensure sling is within signal range Obstructions may aect signal range. Restart computer. Sling is indicating overload without having a load on it. 1. Sling may have exhibited damage during its last lift or during handling return to a Slingmax Dealer for repair. Text messages/emails are not being sent. 1. 2. 3. 4. Ensure computer is connected to the internet. Ensure SMS alerts are turned on for each user. Ensure phone number and email addresses are accurate. Check spam messages. This device has been designed to operate with the antennas listed below, and having a maximum gain of 2 dBi (base station antenna) and 3 dBi (node antenna). Antennas not included in this list or having a gain greater than 2 dBi (base station antenna) and 3 dBi
(node antenna) are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Manufacturer Model Type Component Gain (dBi) Nearson, Inc. S152AH-915S External Whip Base station 2dBi Anaren 66089-0906 Internal Whip Node 3dBi To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. WARNING!
FCC and IC Radiation Exposure Statement:
This equipment complies with FCCs and ICs RF radiation exposure limits set forth for an uncontrolled environment under the following conditions:
1. This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between
(antenna) &
radiator users/nearby persons body at all times. 2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. the FCC Statements Changes or modications not expressly approved by Slingmax Rigging Solutions could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter-
ference when the equipment is operated in a com-
mercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CANADA This device complies with Industry Canada licence-ex-
empt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux condi-
tions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouil-
lage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement.