Alliance-TR_N2ROU_CALA for Mexico(Remote Unit) User Manual SOLiD, Inc. 393-400 10,9th Floor, SOLiD Space220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea Tel: +82-31-627-6290 Fax: +82-31-627-6209 Confidential & Proprietary 1/32 Preface Copyright REVISION HISTORY Version Issue Date Section Description V 1.0 April 27, 2020 All Original Technicians using these manuals should have completed the SOLiD Certification Program. SOLiD also recommends technicians be familiar with the concepts of fiber optic cabling, networking and wireless communication technologies, and SNMP. We further recommend training programs offered through CIBET (Certified In Building Engineering Technologist) and BICSI (Building Industry Consulting Service International). This manual is written and produced by SOLiD and printed in the USA. All rights are reserved 2015 SOLiD. Confidential and proprietary. Information contained in this document is company private to SOLiD and should not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of SOLiD. Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.kr Confidential & Proprietary 2/32 Section1 Section2 Section3 Section4 Section5 Contents 1.1 Safety & Certification Notice ............................................................................... 4 2.1 Overview ........................................................................................................... 7 2.2 N2ROU .............................................................................................................. 8 3.1 Functional Description ....................................................................................... 9 3.2 N2ROU Component .......................................................................................... 11 3.3 Dimension ....................................................................................................... 13 4.1 Installation ...................................................................................................... 14 4.2 Required Materials ........................................................................................... 14 4.3 Install N2ROU .................................................................................................. 17 4.3.1 Install N2ROU .................................................................................................. 17 4.3.2 N2ROU Power Cabling ...................................................................................... 21 4.3.3 N2ROU Ground Cabling .................................................................................... 22 4.3.4 Optical Cabling ................................................................................................. 24 4.3.5 Mounting N2RDU (Optional Modules) ............................................................... 25 4.3.6 MIMO Antenna Connection (Optional) .............................................................. 28 5.1 Specifications................................................................................................... 29 5.2 RF Performance ............................................................................................... 30 5.3 Certification ..................................................................................................... 30 Confidential & Proprietary 3/32 Section1 1.1 Safety & Certification Notice Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.
- Obey all general and regional safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
- The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.
- To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm.
- When working with units outdoors, make sure to securely fasten the door or cover in an open position to prevent the door from slamming shut in windy conditions.
- Use this unit only for the purpose specified by the manufacturer. Do not modify or fit any spare parts that are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.
- Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 310cm minimum clearance from the antenna while the system is operating.
- Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation.
- Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors.
- Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure.
- Allow sufficient fiber length to permit routing without severe bends. Confidential & Proprietary 4/32
- For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible.
- Certification 27 and 90 FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24, UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product conforms to all applicable standards of 21 CFR Chapter 1, Subchaper J, Part 1040
- A readyily accessible disconnect device shall be incorporated external to the equipment.
- This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device
- Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device.
- Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device.
- The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station.
- Round terminals located on the side of a 1 mm2 (16 AWG) or more wires Using permanently connected to earth. (Green/yellow color)
- The following notice: "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device."
Confidential & Proprietary 5/32
- Prior to equipment use the service must be registered with the FCC. This can be done through the FCCs website at https://signalboosters.fcc.gov/signal-boosters/.
- Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and
- Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location.
- Notice! Be careful not to touch the Heat-sink part due to high temperature.
- Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited.
- Home/ personal use are prohibited.
Signal booster warning label message WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device. CAUTION DOUBLE POLE/NEUTRAL FUSING Confidential & Proprietary 6/32 Section2 2.1 Overview The N2ROU is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. Shopping malls Hotels Campus areas Airports Clinics Subways Multi-use stadiums, convention centers, etc. The system helps improve in-building radio environments in poor condition and make better poor RSSI and Ec/Io. By providing communication services at every corner of buildings, the system enables users to make a call at any site of buildings. The system uses digital (CDMA, WCDMA, LTE) methods. The N2ROU system supports communication standards interface protocols in worldwide use. Frequencie Bands : 850C, 1900P, AWS13, L2600F Voice protocols: CDMA etc. Data protocols: WCDMA,CDMA2000, LTE etc. N2ROU is basically equipped with four-band (850C, 1900P, AWS13, L2600F) modules. The 1900P_M, L2600F_M, AWS13_M bands are serviceable, but up to two optional modules (Bands) are supported. Multiple signals are transmitted by one fiber optic cable, and the system does not require additional facilities each time a new frequency is added. The characteristics of this system are as follows :
Confidential & Proprietary 7/32 Flexibility & Scalability Support fiber-optic ports up to 60 Clustering multiple-buildings (campus) as one coverage Option structures Modular frequency upgrade Multi-Band, Multi Operator Signals with a plurality of service provider transmit simultaneously Support multi-operator in a band Low OPEX / CAPEX Compact design Upgradable design Easy installation and maintenance 2.2 N2ROU The N2ROU (New 2W Remote Optical Unit) is one of the Alliance-TR DAS series that supports 2W output power. There are two types of N2ROUs: four-band (SISO) support and two-band
(MIMO) support multiplexers.
(4-Band Multiuplexer: 850C, 1900P, AWS13, L2600F)
(2-Band Multiuplexer: 1900P_M, L2600_M)
(2-Band Multiuplexer: AWS13_M, L2600_M) N2ROU sends a signal that multiple operators and multiple technologies are simultaneously transmitted from BTS to remote locations via the same optical fiber. Confidential & Proprietary 8/32 Section3 3.1 Functional Description The following figure shows the block diagram of N2ROU. The N2ROU has four different diagrams based on optional modules. The diagram shown below is the first one with the default combination. Figure 3.1 N2ROU Block Diagram (4 Bands) RPSU (AC): Remote AC Power Supply Unit (When using the AC input power) The components are;
R-Optic: Remote Optical Unit RCPU: Remote Central Processor Unit N2RDU_8519A1326: Remote Drive Unit (4 bands) N2ROU_MUX_5B_708519A1326: Combining Unit Confidential & Proprietary 9/32 The diagram below shows the 4 bands(SISO) combination and 2 bands(MIMO). combination 4 base bands with 2 additional bands. Figure 3.2 N2ROU Block Diagram (4 bands(SISO) + 2 bands(MIMO)) RPSU (AC): Remote AC Power Supply Unit (When using the AC input power) The components are;
R-Optic: Remote Optical Unit RCPU: Remote Central Processor Unit N2RDU_8519A1326: Remote Drive Unit (4 bands) N2RDU_1900P_M: Remote Drive Unit (1 band) N2RDU_L2600F_M: Remote Drive Unit (1 band) N2ROU_MUX_5B_7085182126: Combining Unit N2ROU_MUX_2B_1926: Combining Unit N2ROU_MUX_2B_A1326: Combining Unit Confidential & Proprietary 10/32 3.2 N2ROU Component bands. The following figure shows internal configuration of the N2ROU fully equipped with frequency Figure 3.5 Internal View of Remote Unit The N2ROU receives TX optical signals from Head-End and converts them into RF signals. The converted RF signals are amplified through High Power Amp in a corresponding RDU, combined with Multiplexer module and then radiated to the antenna port. RX signals received from the antenna port are filtered through the multiplexer module, amplified at the RDU modules, and converted into optical signals via optical module. After converted, the signals are sent to a upper device of ODU or iODU. Four base bands are installed and additional two RDU modules can be installed on the right side of the enclosure. Refer to the image above. Confidential & Proprietary 11/32 The following table describes components of N2ROU. Unit Description N2RDU Remote Drive Unit Amplify TX signals Amplify RX signals Remove other signals through BPF Remote AC Power Supply Unit RPSU (AC) Input power: 90~280 VAC Output power: +29.2 VDC Remote Optic Convert RF signals into optical signals and vise versa; Compensate optical loss R-OPTIC Communicate with BIU/OEU though the WIFI modem 5dBo optical link between ODU (OM4) and ROU 10dBo optical link between ODU (OM1) and ROU Fiber Connector: SC/APC Connector Fiber Type: Single Mode Fiber Optical Wavelength: 1310/1550 WDM Remote Central Processor Unit RCPU Controls signal of each unit MUX_4B_8519A1 326 MUX_2B_1926 MUX_2B_A1326 Monitors BIU/ODU/OEU through the WIFI modem Multiplexer 4-band(SISO bands) Combine TX signals from 4 RDUs; Distribute RX signals to 4 RDUs Allow to use a single antenna port for 4 bands Multiplexer 2-band(MIMO bands) Combine TX signals from 2 RDUs; Distribute RX signals to 2 RDUs Allow to use a single antenna port for 2 bands Enclosure to satisfy IP66 ROU Enclosure Vertical Mount Wall Mount Confidential & Proprietary 12/32 3.3 Dimension Figure 3.6 Remote Unit Dimension ITEM SPECIFICATION REMARK Dimensions (WxHxD) 18.5x16.5" (10 RU) x 10.2
(470mm x 420mm x 260mm) Including Bracket Weight Max. 69.44 lbs (31.5kg) for base model, 4 bands Max. 72.75 lbs (33kg) for 5 bands Max. 80.46 lbs (36.5kg) for 6 bands MUX included Confidential & Proprietary 13/32 Installation Step Remote Installation Power Connection_AC Ground Connection Optical Connection Antenna Connection Section4 4.1 Installation This chapter describes how to install each unit and optical cables. It also explains how to install shelves or enclosuers of each unit, power cabling method and optical cabling and RF interface. Required accessories and tools for installation are list up in the below table. 4.2 Required Materials Accessory Included Tool Remark Enclosure M12 Bolt (4EA) AC 120V power cable (1EA)
[2 meter, with MIL-5015 type Connector (MS-3106A- 18-10S) at one end, AC Plug at another end]
M6 Screw (1EA) Screwdriver X X X X Spanner
(19mm)
Crimping refer to tool 4.3.3.
#2
For more details, For more details, refer to 4.3.4. 2 EA are required in case Lug (1EA) Max. AWG #6 Cable Optical Cable Assembly Connector (1EA)
[957-5004-105, by Amphenol]
OPTIC SC/APC Cable (1EA) 4.3-10 DIN(M) RF Cable (1 or 2EA) Confidential & Proprietary 14/32 N2RDU Installation
(Optional bands) Expansion of N2RDU_L700A
(Not support) RX OUT RF Cable Screwdriver of MIMO. For more details, refer to 4.3.5.
#1
#0
#1
(+) N2RDU_L700A Module M4 Screw (6EA) I/O Cable (1EA) TX IN RF Cable (1EA) Base RDU to Option RDU
(1EA) RDU Base RDU to Option TX RF Cable (1EA) L700A RDU to MUX RX RF Cable (1EA) L700A RDU to MUX N2RDU_1900P_M Module Module Module N2RDU_AWS13_M N2RDU_L2600F_M MUX_2B_1926 MUX_2B_A1326 M4 Screw (18EA) I/O Cable (2EA) TX RF Cable (1EA) Base RDU to Option RDU RDU RX RF Cable (1EA) Base RDU to Option Casecade TX RF Cable(1EA) AWS13_M/1900P_M Expansion of or N2RDU_1900P_M+N2RDU_L2600F_M Screwdriver N2RDU_AWS13_M+N2RDU_L2600F_M Screwdriver Confidential & Proprietary 15/32 to L2600F_M Casecade RX RF Cable(1EA) AWS13_M/1900P_M to L2600F_M MUX RF Cable (1EA) MUX to ANT Port TX RF Cable (1EA) 1900P_M/AWS13_B RDU to MUX RX RF Cable (1EA) 1900P_M/AWS13_M RDU to MUX TX RF Cable (1EA) L2600F_M RDU to MUX MUX RX RF Cable (1EA) L2600F_M RDU to RF Adaptor MIMO Antenna
[4.3-10 DIN(F) type to SMA(F) type Adaptor]
Connection
(Optional) M3 Screw (4EA) Inner Data Interface Cable (1 EA) Connection
[0.5 meter, with MIL-5015 type Connector (97-3102A-14S-5P) with External and Signal Connector (SMH200-05)]
Alarm M3 Screw (4EA)
#0 Screw driver (+)
#0 Screw driver (+) For more details, refer to 4.3.6. For more details, refer to 4.3.7. Confidential & Proprietary 16/32 4.3 Install N2ROU 4.3.1 Install N2ROU N2ROU is included. The N2ROU uses a unibody enclosure that is NEMA 4 (IP66) certified to withstand water and dust intrusion. It can be mounted on a pole, wall, or rack. Basically wall-mounted bracket for Figure 4.1 Exterior of N2ROU Confidential & Proprietary 17/32 Figure 4.2 N2ROU Wall Mount Dimensions Figure 4.3 N2ROU Rack Mount Dimensions Confidential & Proprietary 18/32 N2ROU Wall Mount Procedure The enclosure comes with the bracket for wall mounting. It doesnt need to remove the bracket to install the enclosure, simply install and tighten 4 mounting bolts to secure the unit. First, install 2 of M12 mounting bolts roughly half way into the wall. Mount the enclosure and tighten the bolts. Second, tighten the remaining M12 mounting bolts under the enclosure and secure the unit tightly. Figure 4.4 Installation Procedure Confidential & Proprietary 19/32 N2ROU Components N2ROU has the following components:
No. Unit Description Remark Enclosure N2ROU_BASE_AC RCPU Remote Central Processor Unit R_OPTIC Remote Optic (only Remote Unit) RPSU Remote AC Power Supply Unit Power Cable MS Connector with 4 holes Common Part N2RDU N2RDU_8519A1326 N2RDU_1900P_M N2RDU_AWS13_M N2RDU_L2600F_M Internal Combiner Unit for 850C, 1900P, AWS13, MUX_4B MUX_2B L2600F Internal Combiner unit for 1900P_M, L2600F_M Internal Combiner unit for AWS13_M, L2600F_M Basically, the N2ROU is equipped with RCPU to check and control state of each module, R_OPTIC to covert RF to opticals and vise versa, RPSU to supply power for N2ROU. It should have a power cable for external rectifier or to supply required power. 1EA 1EA 1EA 1EA 1EA ANT1 ANT2 1EA 1EA 1EA Confidential & Proprietary 20/32 4.3.2 N2ROU Power Cabling AC Power The N2ROU supports only AC 120V input power and only a single type of power cable is provided. The pin discription of AC port is as below. Pay attention to the correct polarity. AC Power Port MS Connector No. Name Description A B C D AC_H AC Hot AC_N AC Neutral N.C Not Connected F.G Frame Ground Check if the connection is the same as one seen in the table above and make sure to turn the power ON. The figure below is the AC power cable that comes with the unit. Figure 4.5 AC Power Cable Confidential & Proprietary 21/32 4.3.3 N2ROU Ground Cabling The grounding terminal is located at the bottom of N2ROU enclosure fixed by an M6 screw. Compression terminal is attached already when it is delivered. The recommended thickness of cable is AWG#6 copper grounding wire. Figure 4.7 Location of Ground Terminal The specification of compression terminal is as follows. Figure 4.8 Information of Terminal Confidential & Proprietary 22/32 The required part number is JOCO 0102-RS06 that supports AWG 6. To install the grounding cable, follow the steps below. Figure 4.9 Installing Ground Terminal The procedures are 1. Loosen two M6 screws and then take compression terminal off 2. Insert AWG#6 grounding wire into terminal, and then compress a terminal using the tool 3. Assemble the terminal with 2xM6 screws 4. Cut the ground wire to proper length and connect it to the earth ground source Confidential & Proprietary 23/32 4.3.4 Optical Cabling by using its connectors. The Optical connector is located at the bottom of the N2ROU. Optical cable can be connected Figure 4.10 Optical Connector Refer to the figure below for detailed information. The figure is based on LC type, but can be applied to SC type as well. Confidential & Proprietary 24/32 4.3.5 Mounting N2RDU (Optional Modules) The N2ROU has the basic modules as shown on the left side of the enclosure (see the figure below) and the maximum of two optional remote units can be installed on the right. Various combinations can be configured based on different services and conditions. Figure 4.11 Location of N2RDU Confidential & Proprietary 25/32 Mounting of N2RDU_1900P_M+ N2RDU_L2600F_M or AWS13_M+ N2RDU_L2600F_M
(MIMO Band Expansion) N2RDU_1900P_M, N2RDU_AWS13_M and N2RDU_L2600F_M module can be installed in the N2RDU as an optional module in the pink box shown in the figure below. It can be installed with 12 screws included in the package. Figure 4.14 Install N2RDU_1900P_M + N2RDU_L2600F_M or AWS13_M +
N2RDU_L2600F_M To service 1900P_M, AWS13_M and L2600F_M Band Expansion, MUX_2B(1926 or A1326) is required, and it can be installed with 6 screws included in the package. Figure 4.15 Install MUX_2B(1926 or A1326) Confidential & Proprietary 26/32 Refer to the figure below for cabling in order to service 1900P_M + L2600F_M or AWS13_M +
L2600F_M Band Expansion. Figure 4.16 Cabling of N2RDU_1900P_M + N2RDU_L2600F_M or N2RDU_AWS13_M +
N2RDU_L2600F_M (MIMO Band Expansion) Confidential & Proprietary 27/32 4.3.6 MIMO Antenna Connection (Optional) To support MIMO service, MIMO Antenna connection is required. Figure 4.22 Installing MIMO Antenna Adaptor The procedures are 1. Remove the dummy cover from the ANT2 port. 2. Install 4.3-10 DIN(F) to SMA(F) Adaptor with the screws included in the package. Confidential & Proprietary 28/32 Section5 5.1 Specifications Mechanical Specification Mounting Type Wall or rack mounting Connectors Craft Port Power Consumption Antenna port type: 4.3-10 DIN (M) type Fiber connectors: SC/APC for connecting to ODU or OEU Serial interface RS-232 9-pin D-sub Male for connecting management PC
(on CPU) 175W for 4 bands(850C, 1900P, AWS13, L2600F) 265W for 6bands(850C, 1900P, AWS13, L2600F, 1900P_M, L2600F_M or 850C, 1900P, AWS13, L2600F, AWS13_M, L2600F_M) optional band is AWS13_M and L2600F_M Environmental Specification Environmental & IP Rating IP66 Compliant, NEMA4 Operating Environment Temp Range: -10C to 50C. Humidity: 5 to 90% non-condensing Optical Specification Confidential & Proprietary 29/32 Optics SC/APC (Step Ferrule) Laser Diode/Photo Diode 1550nm/1310nm (Coaxial Type) Optical Loss Max 5dBo (4-port optical module); Max 10dBo (1-port optical module) 5.2 RF Performance N2RDU Specifications per Band Downlink(Tx) Uplink(Rx) Frequency Band Frequency(MHz) Bandwidth(MHz) Frequency(MHz) Bandwidth(MHz) Output Pwr(dBm) 850C 1900P AWS13 L2600F 1900P_M AWS13_M L2600F_M 869 ~ 894 1930 ~ 1995 2110 ~ 2180 2620 ~ 2690 1930 ~ 1995 2110 ~ 2180 2620 ~ 2690 25 65 70 70 65 70 70 33 33 33 33 33 33 33 824 ~ 849 1850 ~ 1915 1710 ~ 1780 2500 ~ 2570 1850 ~ 1915 1710 ~ 1780 2500 ~ 2570 25 65 70 70 65 70 70 5.3 Certification Environmental Specification Environmental & IP Rating IP66 Compliant, NEMA4 Operating Environment Temp Range: -10C to 50C. Humidity: 5 to 90% non-condensing Confidential & Proprietary 30/32 FCC Part 15.105 statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Part 15.21 statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. RF Exposure Statement The antenna(s) must be installed such that a minimum separation distance of at least 320 cm is maintained between the radiator (antenna) and all persons at all times. This device must not be co-located or operating in conjunction with any other antenna or transmitter. RSS-GEN, Sec. 7.1.2 (transmitters) Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation dIndustrie Canada, le prsent metteur radio peut fonctionneravec une antenne dun type et dun gain maximal (ou infrieur) approuv pour lmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention desautres utilisateurs, il faut choisir le type dantenne et son gain de sorte que la puissance isotroperayonne quivalente (p.i.r.e.) ne dpassepas lintensit ncessaire ltablissement dune communication satisfaisante. Confidential & Proprietary 31/32 RSS-GEN, Sec. 7.1.2 (detachable antennas) (Max. antenna gain : 17 dBi) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le prsent metteur radio (identifier le dispositif par son numro de certification ou son numro de modle sil fait partie du matriel de catgorie I) a t approuv par Industrie Canada pour fonctionner avec les types dantenne numrs ci-dessous et ayant un gain admissible maximal et limpdance requise pour chaque type dantenne. Les types dantenne non inclus dans cette liste,ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour lexploitation de lmetteur. RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 320 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. RSS-102 RF Exposure metteur. Lantenne (ou les antennes) doit tre installe de faon maintenir tout instant une distance minimum de au moins 320 entre la source de radiation (lantenne) et toute personne physique. Cet appareil ne doit pas tre install ou utilis en conjonction avec une autre antenne ou Confidential & Proprietary 32/32