PIRAMID XL3 US PIRAMID XL3 DUAL-TECHNOLOGY SENSOR Installation instructions - Pages 1-28 Toll Free: 1-800-498-9662 / Phone: (775) 856-7333 / Fax: (775) 856-7658 Website: www.protechusa.com 529 VISTA BLVD 89434 SPARKS, NV - USA E-mail: sales@protechusa.com NT412 / V1.2 / 09.18 PROTECH PIRAMID XL3 CONTENTS 1 GENERAL .............................................................................................................2 2 DESCRIPTION ......................................................................................................3 3 OPERATION .........................................................................................................4 4 5 INSTALLATION PRECAUTIONS ..........................................................................6 INSTALLATION .................................................................................................. 10 6 WIRING ............................................................................................................... 11 6.1 Wiring PIRAMID XL3 ........................................................................................................... 11 6.2 Maximum length of 12VDC power supply cables ................................................................. 12 7 SET-UP ............................................................................................................... 12 7.1 Settings PIRAMID XL3 ......................................................................................................... 12 7.2 Anti-masking alarm .............................................................................................................. 15 7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode ............................................. 16 8 SMARTPHONE APPLICATION .......................................................................... 17 8.1 Managing settings ................................................................................................................ 19 8.2 PIRAMID XL3 settings ......................................................................................................... 19 8.3 Real-time Information ........................................................................................................... 21 8.4 Event log .............................................................................................................................. 22 9 PERIODIC MAINTENANCE ................................................................................ 24 10 MAINTENANCE .................................................................................................. 24 11 TECHNICAL SPECIFICATIONS ......................................................................... 25 12 PRODUCT REFERENCES .................................................................................. 26
- 1 -
PROTECH 1 GENERAL PIRAMID XL3 is a dual-technology sensor:
PIRAMID XL3 A passive infrared unit composed of a pyroelectric infrared (PIR) sensor that detects radiation emitted by the human body in the infrared spectrum. A Microwave antenna using a 10,510 GHz frequency transmitter and a Doppler Effect receiver detect changes in the state of the radiation field caused by passage of an object or body in the lobe created by the antenna. The detection zone formed by the lobe of the microwave antenna and the beams from the mirror of the PIR create an invisible detection zone. To trigger an alarm, it is necessary that the object or intruder pass through the detection zone. MAIN FEATURES:
Maximum outdoor range:
SDI-78XL3-A:
SDI-78XL3-B:
SDI-78XL3-C:
SDI-78XL3-D:
SDI-78XL3-H:
SDI-78XL3-H60:
SDI-78XL3-H40:
SDI-78XL3-H20:
/ 30m x 30m 98ft x 98ft 98ft x 33ft
/ 30m x 10m 131ft x 19.7ft / 40m x 6m 131ft x 9.8ft / 40m x 3m 98ft x 85ft
/ 30m x 26m
/ 30m x 14m 98ft x 46ft
/ 30m x 7m 98ft x 23ft 98ft x 9.8ft
/ 30m x 3m Horizontal orientation +/- 90 in 10 increments. Vertical orientation from 0 to -10 maximum. Anti-masking function by infrared Led.
- 2 -
Front view PROTECH 2 DESCRIPTION Top view PIRAMID XL3 PIR Lens MW antenna cover Back view Side view
- 3 -
PROTECH 3 OPERATION Characteristics of detection zone:
SDI-78XL3-A Top view m 0 3
/
t f 8 9 98 ft / 30 m Side view lens A Side view lens A-Pet SDI-78XL3-C Top view m 6
/
t f
. 7 9 1 131 ft / 40 m Side view lens C Side view lens C-Pet PIRAMID XL3 m 0 1
/
t f 3 3 m 3
/
t f
. 8 9 SDI-78XL3-B Top view 98 ft / 30 m Side view lens B Side view lens B-Pet SDI-78XL3-D Top view 131 ft / 40 m Side view lens D Legend:
PIR detection zone MW detection zone
- 4 -
PROTECH PIRAMID XL3 SDI-78XL3-H Top view SDI-78XL3-H60 Top view m 6 2
/
t f
. 3 5 8 m 7
/
t f 3 2 m 4 1
/
t f
. 9 5 4 98.4 ft / 30 m Side view SDI-78XL3-H40 Top view 98.4 ft / 30 m Side view 98.4 ft / 30 m Side view SDI-78XL3-H20 Top view 98.4 ft / 30 m Side view m 3 Legend:
PIR detection zone MW detection zone
- 5 -
INSTALLATION PRECAUTIONS PROTECH 4 It is important to follow certain rules to ensure proper installation of the detector:
PIRAMID XL3
- ENSURE THAT NO VEGETATION IS FOUND IN THE DETECTION ZONE. CHECK THAT THE CLOSEST VEGETATION DOES NOT OBSTRUCT THE DETECTION ZONE IN CASE OF WIND. DONT DO
- RESPECT THE RECOMMENDED INSTALLATION HEIGHT. t n e e w e b e b t s u m t i h g e h n o i t a l l a m 4 d n a m 2
/
t f 3 1 d n a t f 6 6
. t s n I
- 6 -
PROTECH PIRAMID XL3
-
INSTALL THE DETECTOR ON A STABLE MOUNTING SURFACE DONT mount the detector on a surface exposed to strong vibrations, such as a fence with no support or a flimsy metal surface. DO: Mount the detector on a wall or solid post If it is installed on a building with a metal surface, the support must be vibration-resistant. Vibration-resistant Support Structure Vibration-resistant Support non sensible Support Structure aux vibrations
- USE AS A MOTION DETECTOR AND NOT AS A PERIMETER DETECTOR DONT use the PIRAMID XL3 as a perimeter detector. For good transverse detection, the sensitivity must be set to maximum, which risks increasing the number of unwanted alarms triggered. DONT DO: Use the PIRAMID XL3 as an approach detector (use of A, B or C lenses possible). A low sensitivity setting enables a reduction of the number of unwanted alarms triggered. DO BUILDING BUILDING
- BE CAREFUL OF WASTE WHICH COULD ATTRACT SMALL ANIMALS AND BIRDS
- 7 -
PIRAMID XL3 PROTECH DONT leave any bin in the range of the detector which could attract small animals and birds. When they are near to the detector, they may be identified as larger targets by the detector. DONT detector. DO DO: Place bins away from the range of the Rubbish Rubbish
- BE CAREFUL OF BIRDS WHICH COULD PERCH IN THE RANGE OF THE DETECTOR DO: Select a location which provides the detector with a range which is free of any obstacles. DO DONT install the detector near to lighting fixtures or signage. They can be used as perches by birds and trigger false alarms. DONT
- 8 -
PROTECH PIRAMID XL3
- BE CAREFUL OF ANIMALS PASSING THROUGH HOLES IN OR DUG UNDER A FENCE DONT ignore openings which have been made in a fence and may provide an easy passage for small animals (dogs, cats, raccoons, etc.) in the protected area. DONT
-
DO: Repair holes in the fence (or fill in holes dug underneath) to block access to the protected area. DO
- WARNING IF INSTALLING THE SENSOR UNDER EAVES DONT mount the detector under eaves which are not equipped with a gutter. In the event of heavy rainfall, the flow of water directly in front of the sensor may trigger false alarms. DONT DO: mount the detector under eaves provided that they are equipped with a gutter. DO
- 9 -
PROTECH 5 INSTALLATION PIRAMID XL3 For optimum performance, the PIRAMID XL3 detector must be installed at a height between 6.6ft / 2m and 13ft / 4m. Drilling template for wall mounting:
2.4 in
/ 60mm n i 2 3
. m m m 0 8
/
Drilling template for corner mounting:
REQUIRED ACCESSORIES TO MOUNT PIRAMID XL3:
- 4 Screws 4.8x60
- 4 Screw anchors
- 4 Washer 5
- 1 Hex key size 6mm m m 0 7 i n
,8 2 m m 0 7 n i
,8 2 m m 0 1 n i 0,4 0,7 in 1 9 m m
,7 in19 mm
- 10 -
PIRAMID XL3 PROTECH Opening the cover Loosen the screw, raise, and then pull the cover up. 6 WIRING 6.1 Wiring PIRAMID XL3 1: 12V DC power supply 2: 0V DC power supply 3: Intrusion alarm contact NC 4: Intrusion alarm contact NO 5: Intrusion alarm contact COM 6: Anti-masking alarm contact NC 7: Anti-masking alarm contact NO 8: Anti-masking alarm contact COM 13: Tamper Contact NC *
14: Tamper Contact NO *
15: Tamper Contact COM *
- 11 -
PROTECH 6.2 Maximum length of 12VDC power supply cables
(Wire type SYT1 shielded) PIRAMID XL3 Wire Wire section 0.02 in 0.04 in 0.06 in 0.6 mm 23 AWG 0.3 mm 0.9 mm 20 AWG 0.6 mm 1.4 mm 16 AWG 1.5 mm Maximum length of cables 0.06 mi 0.13 mi 0.29 mi 94 m 211 m 470 m Note: When using the same cable to supply power to several components, the indicated distances should be divided by the number of connected components. When using several wires with the same section in parallel by polarity, the indicated distances should be multiplied by the number of connected wires. PIR LED ALARM LED 7 SET-UP 7.1 Settings PIRAMID XL3 Using the setting mode:
ALARM LED: lights up when the PIR and MW are in alarm. PIR LED: lights up when the PIR is in alarm. MW LED: lights up when the MW is in alarm. Code selector max. distance: setting the maximum distance of detection. The detector is insensitive to moving objects beyond this distance. Code selector setting max. distance Code selector setting Sensitivity MW LED Code selector value 1 2 3 4 5 6 7 8 9 Distance 16.4 ft
/ 5 m 33 ft
/ 10 m 49 ft
/ 15 m 66 ft
/ 20 m 82 ft
/ 25 m 98 ft
/ 30 m 115 ft
/ 35 m 131 ft
/ 40 m 147 ft
/ 45 m Code selector sensitivity: setting the sensitivity of the MW. High sensitivity Low sensitivity
- 12 -
PROTECH PIRAMID XL3 1. Turn the Test Mode switch to the ON position to change to Settings mode. 2. Set the sensitivity to maximum (code selector set to 9). Code selector sensitivity setting 3. Set the maximum distance beyond which the PIRAMID XL3 should not detect. Code selector setting Max. distance Code selector value 1 2 3 4 5 6 7 8 9 Distance 16.4 ft / 5 m 33 ft / 10 m 49 ft / 15 m 66 ft / 20 m 82 ft / 25 m 98 ft / 30 m 115 ft / 35 m 131 ft / 40 m 147 ft / 45 m Note: On the two code selectors, setting 0 is reserved for rereading the value memorized in the detector. (See 7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode)
- 13 -
PIRAMID XL3 4. Turn the product on, the PIR and MW LEDs will light up when the initiation phase has ended PROTECH
(5s). ALARM LED PIR LED MW LED 5. Determine the desired PIRAMID XL3 detection range by performing walk test in this area. Adjust detector orientation and sensitivity to the required settings. When one of the technologies, PIR or MW, switches to alarm status, the associated LED will light up red. When both PIR + MW technologies are in alarm status, the ALARM LED will light up red. Detector status NO alarm Alarm PIR Alarm MW Alarm intrusion
(PIR + MW) Legend:
ALARM LED LO LO LO RL MW LED PIR LED Buzzer *
GL GL RL RL GL RL GL RL Off Slow beers Rapid beeps Continuous LO : LED off RL : Red LED on GL : Green Led on
* If buzzer is enabled in the hub
- 14 -
PROTECH PIRAMID XL3 6. Turn the "Test Mode" to the OFF position to switch to detection mode. 7. Close the cover. 8. In normal operation, the LEDs are off. It is possible to activate them via smartphone application (see 8.2). Note: INTRUSION and "MASKING relays remain in alarm status when the "Test Mode"
switch is in the ON position. 7.2 Anti-masking alarm The alarm is triggered when an obstacle obstructs the masking sensor located in the upper cover.
(The masking alarm is triggered approximately 15s after the obstacle has been located) Anti-masking sensor
- 15 -
PROTECH 7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode Sensitivity and distance settings max. can be modified:
- Either via the code selectors on the detector
- Or via the smartphone application PIRAMID XL3 Note: In Settings mode, sensitivity and distance settings are stored in memory by the code selectors. In Detection mode, sensitivity and distance settings are stored in memory either by the application: last backup performed. To find out the values of stored settings, switch the detector to READ mode:
1. Set the code selector to "0". 2. Turn the "Test Mode" switch to ON. 3. The detector LED(s) will blink. Note: only the LED linked to the code selector set to 0 will blink. Max distance LED setting Sensitivity LED setting Max distance code selector setting Code selector sensitivity setting
- 16 -
PROTECH PIRAMID XL3 4. Turn the code selector until the LED is permanently lit. The value displayed on the code selector corresponds to the stored setting. 5. Turn the "Test Mode" switch OFF to exit Read mode. 8 SMARTPHONE APPLICATION Note: The smartphone application is compatible from Android 4.1 or higher. 1. Download the Sorhea Connect smartphone application. Sorhea Connect 2. Launch the Sorhea Connect application. Authorize activation of Bluetooth if requested to do so by the application. 3. Check that the tamper switches are turned downwards. Switches down
- 17 -
PROTECH PIRAMID XL3 4. Set a tamper alarm to activate the BLE connection with the smartphone application: leave the tamper contact pressed down for 2 seconds, then release. Note: the connection remains active for as long as the PIRAMID XL3 is connected to the smartphone application. It is disconnected when the cover is shut (tamper contact closed) or after 1 minute of inactivity (application closed). Tamper contact 5. Launch the search. 6. Click on the product found. PIRAMID XL3 Radio ID found is identical to the sticker on the card PIRAMID XL3 found
- 18 -
PIRAMID XL3 Setting the time on the PIRAMID XL3 Name of PIRAMID XL3:
Click on the name to change it then click on Save. PROTECH 8.1 Managing settings 8.2 PIRAMID XL3 settings 1. Click on Menu Menu 2. Click on Settings Settings
- 19 -
PROTECH PIRAMID XL3 Disable Sensor not ejected 3. PIRAMID XL3 settings Legend:
Enable Sensor ejected LEDS enabled / disabled Buzzer enabled / disabled Relay outputs enabled / disabled Antimask enabled / disabled MW ejection PIR ejection Moving direction:
Settings save above MW range: Modification of the maximum detection range of the MW. MW sensitivity: Modification of the detection sensitivity of the MW. Max. speed: Modification of the maximum speed to detect of the MW. MW Range settings 1 : 16 ft / 5 m MW Sensitivity settings 1 : Not very sensitive Max. speed settings:
0.62 to 31 mph / 1 to 50 km/h MW and PIR settings save 1 : Not very sensitive Distance to be covered settings:
0.33 to 16 ft / 0.1 to 5m PIR Sensitivity settings:
9 : 148 ft / 45 m 9 : Very sensitive 81 : Very sensitive Makes it possible to filter objects for which the speed is superior to the Speed max.. Distance of movement: Modification of the maximum distance an object has to move before the MW detects it. Minimum distance of movement that an object has to move in the same direction before triggering an alarm. PIR sensitivity: Modification of the detection sensitivity of the PIR.
- 20 -
PROTECH 8.3 Real-time Information 1. Click on Menu PIRAMID XL3 Menu 2. Click on Real-time Real-time 3. Viewing PIRAMID XL3 real-time information MW and PIR sensor status Intrusion and anti-mask relays status Test mode switch status
: Setting mode
: Detection mode Internal temperature of the PIRAMID XL3 Power supply Legend:
No Alarm Alarm
- 21 -
PIRAMID XL3 PROTECH 8.4 Event log 1. Click on Menu Menu 2. Click on Event log Event log
- 22 -
PROTECH 3. View event log PIRAMID XL3 Date/Time of the event Type of events PIRAMID XL3 setting List of events:
- Alarm intrusion
- Alarm mask
- End alarm mask
- Alarm tamper
- End alarm tamper
- Time setting
- Configuration
- Power on
- Raz event log
- Blocking event log
- Unblock event log
- Default 12V
- End default 12V
- Default MW
- End default MW
- Default radio card
- End default radio card
- MW ejected
- End MW ejected
- PIR ejected
- End PIR ejected
- BLE Connection
- End BLE Connection
- 23 -
PROTECH 9 PERIODIC MAINTENANCE To guarantee performance over time, basic maintenance operations should be performed to confirm the status of the PIR filter. If necessary, clean the filter with a soft, moist cloth. 10 MAINTENANCE PIRAMID XL3 Default settings:
- LEDs status
- Buzzer status
: disable
: enable
(see 8.2 for led settings)
(see 8.2 for buzzer settings) Failure Probable causes Solutions
- "Test Mode" switch in the
- Turn the "Test Mode" switch to the Permanent alarm No triggering of the intrusion alarm Anti-masking alarm in permanent alarm ON position.
-
Incorrect voltage (<10V)
- The relays are disabled.
- Passage beyond the distance set on the code selector. OFF position.
- Check the power supply.
- Enable relays via the application
(see 8.2)
- Change the distance set on the code selector.
- The relays are disabled.
- Enable relays via application
(see 8.2)
- Enable the anti-masking alarm
- The anti-masking alarm is
(see 8.2) disabled.
- Tamper switches are in up.
-
Permanente tamper alarm
-
If the tamper is to be used in a local connection, wire the terminals 13,14,15. If the tamper is to be used in a network connection, turn the switches to the bottom.
- Press on the tamper switch for at least 2 seconds, then release.
(see 8)
- Check that the tamper switches are towards the bottom. (see 8) The smartphone application cannot detect the PIRAMID XL3.
- The PIRAMID XL3 BLE connection is not activated.
- 24 -
PROTECH 11 TECHNICAL SPECIFICATIONS Maximum outdoor range Detection mode Antenna MW frequency Power supply voltage Power supply current Typical intrusion alarm duration Typical anti-masking alarm duration NC Tamper relay rating NC Intrusion relay rating NC Anti-masking relay rating Operating temperature Relative humidity Protection Index Weight Electromagnetic compatibility Detector orientation External dimensions:
6,5 in 165 mm m m 0 2 2 i n
,6 8 PIRAMID XL3 SDI-78XL3-A:
SDI-78XL3-B:
SDI-78XL3-C:
SDI-78XL3-D:
SDI-78XL3-H:
SDI-78XL3-H60:
SDI-78XL3-H40:
SDI-78XL3-H20:
/ 30mx30m
/ 30mx10m
/ 40mx6m
/ 40mx3m
/ 30mx26m
/ 30mx14m
/ 30mx7m
/ 30mx3m PIR sensor and MicroWave antenna 98ftx98ft 98ftx33ft 131ftx19.7ft 131ftx9.8ft 98ftx85ft 98ftx46ft 98ftx23ft 98ftx9.8ft 10.510 GHz 10 to 20V DC 80 mA 5 seconds Duration the sensor is masked 24VDC 1A 24VDC 1A 24VDC 1A
-31F to 158F / -35C to +70C 95% max without condensation IP55 1.98 lb / 0,9 Kg Compliance with European standards
(label CE) Horizontal: +/- 90 in increments of 10 Vertical from 0 to -10 9,2 in 233 mm 4,1 in 103 mm
- 25 -
PROTECH 12 PRODUCT REFERENCES PIRAMID XL3 SDI-78XL3-A range 98x98ft / 30x30m white SDI-78XL3-B range 98x33ft / 30x10m white SDI-78XL3-C range 131x19.7ft / 40x6m white SDI-78XL3-D range 131x9.8ft / 40x3m white SDI-78XL3-A PET range 98x98ft / 30x30m white SDI-78XL3-B PET range 98x33ft / 30x10m white SDI-78XL3-C PET range 131x19.7ft / 40x6m white SDI-78XL3-A range 98x98ft / 30x30m gray anthracite SDI-78XL3-B range 98x33ft / 30x10m gray anthracite SDI-78XL3-C range 131x19.7ft / 40x6m gray anthracite SDI-78XL3-D range 131x9.8ft / 40x3m gray anthracite SDI-78XL3-A PET range 98x98ft / 30x30m gray anthracite SDI-78XL3-B PET range 98x33ft / 30x10m gray anthracite SDI-78XL3-C PET range 131x19.7ft / 40x6m gray anthracite SDI-78XL3-H range 98ft x 85ft / 30x26m white SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m white SDI-78XL3-H40 range 98ft x 23ft / 30x7m white SDI-78XL3-H60 range 98ft x 46ft / 30x14m white SDI-78XL3-H range 98ft x 85ft / 30x26m gray anthracite SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m gray anthracite SDI-78XL3-H40 range 98ft x 23ft / 30x7m gray anthracite SDI-78XL3-H60 range 98ft x 46ft / 30x14m gray anthracite ref: 60760301 ref: 60760302 ref: 60760303 ref: 60760304 ref: 60760305 ref: 60760306 ref: 60760307 ref: 60760401 ref: 60760402 ref: 60760403 ref: 60760404 ref: 60760405 ref: 60760406 ref: 60760407 ref: 60760308 ref: 60760309 ref: 60760310 ref: 60760311 ref: 60760408 ref: 60760409 ref: 60760410 ref: 60760411 Changes or modifications not expressly approved by PROTECH could void the users authority to operate the equipment. FCC Part 15 compliance statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
-
- Connect the equipment into an outlet on circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected.
- Consult the dealer or an experienced radio/TV technician for help.
- 26 -
PIRAMID XL3 PROTECH ISED Licence-Exempt Radio Apparatus This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Appareils radio exempts de licence ISDE Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage ;
2. L'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus To satisfy FCC and IC RF Exposure requirements for mobile devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Pour satisfaire aux exigences FCC et IC concernant l'exposition aux champs RF pour les appareils mobile, une distance de sparation de 20 cm ou plus doit tre maintenu entre l'antenne de ce dispositif et les personnes pendant le fonctionnement. Pour assurer la conformit, il est dconseill d'utiliser cet quipement une distance infrieure. Cet metteur ne doit pas tre co-situ ou fonctionner conjointement avec une autre antenne ou un autre metteur PROTECH hereby declares that the device PIRAMID XL3 is in conformity with the essential requirements of Directive 2014/53/EU. The declaration of conformity can be found at:
www.protechusa.com
- Frequency Band: 2400-2483.5MHz / Maximum Transmitting Power: 10mW (EIRP)
- Frequency band: 10.5-10.6GHz / Maximum Transmitting Power: 13mW (EIRP)
- 27 -
PROTECH PIRAMID XL3 In compliance with the European environmental directives, this product must not be thrown away but recycled through an appropriate subsidiary.
- 28 -