Lecteurs ARCT 13.56 MHz Notice dinstallation ARCT 13.56 MHz readers Installation procedure ARCT-A Rfrences produits / Product references J5 J6 L- L+ +Vcc 0V Caractristiques de lalimentation Power supply characteristics La tension dalimentation aux bornes du lecteur doit tre comprise entre +9 Vdc +15 Vdc (+12 Vdc typique). Utiliser une alimentation AC/DC du type LPS, Source Puissance Limite (selon IEC EN 60950-1 Ed2) ou du type ES1, PS1 (selon IEC EN 62368-1). Consommation max sous 12Vdc :120 mA Supply voltage at the readers connector should be between +9 Vdc up to +15 Vdc (+12 Vdc typical). Use AC/DC power supply type LPS, Limited Power Source (according to IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1). Power Consumption max.: 120 mA Type de cble prconis Recommended cables Utiliser un cble multiconducteur blind par tresse. Dport max en RS485 : 600m (cble torsad par paire). Use a multi-conductor cable, pair shielded. Max length RS485: 600m / 1968 ft (twisted pair cable). Buzzer / LED Buzzer / LED Le fonctionnement du buzzer et des LED 1 et 2 est configurable par badge de configuration
(R33) ou pilots par le protocole de communication du lecteur (W33). The operating mode for Buzzer and LED 1 and 2 can be programmed by a configuration card (R33) or driven by the communication protocol of the reader (W33). Fonction anti-arrachement Anti-Tearing Larrachement est dtect par un acclromtre. The tearing is detected by an accelerometer.
- pour R33 : le lecteur effectuera les oprations configures par badge de
- for R33: the reader will do the operations configured with configuration card. configuration.
- pour W33 : le lecteur effectuera les oprations configures via les commandes
- for W33: the reader will do the operations configured through the SSCP protocol. SSCP. Attention : mettre le lecteur sous tension lorsquil est dans sa position finale pour initialiser lacclromtre dans la position correcte. Configuration des lecteurs Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position Reader Configuration Le lecteur R33 est configurable par badge de configuration SCB cr avec SECard. R33 reader is configurable with configuration card SCB created with SECard.
- Si le SCB est compatible avec le firmware du lecteur, la LED devient verte et le buzzer retentit 5 fois.
- Si le SCB nest pas compatible avec le firmware du lecteur, la LED devient rouge et le buzzer est activ 1s.
- If the SCB is compatible with readers firmware, LED lights green and buzzer beeps 5 times.
- If the SCB is not compatible with readers firmware, LED lights red and buzzer is activated 1s. Attention : paramtrer vos lecteurs en dfinissant une cl entreprise personnalise. Caution: set your reader with your own company key. Mise sous tension des lecteurs A la mise sous tension, le lecteur est en phase dinitialisation :
1) Activation de la LED blanche et du buzzer pendant 100 ms. Pour les lecteurs R33 et W33 OSDP :
2) Activation de la LED selon le code couleur :
Powering readers At the power up the reader enters in an initialization phase:
1) Activating white LED and buzzer for 100 ms For the read R33 and W33 OSDP readers:
2) Activating LED according to the color code:
Rouge = +10, Orange = +5, Verte = +1 : Indication de la version firmware. Red = +10, Orange = +5, Green = +1: Indicating firmware version. Pour les lecteurs R33 :
For the read R33 reader:
3) Clignotement de la LED orange 20 fois : attente de mise jour. 4) Activation de la LED par dfaut (bleu fixe si pas de configuration client spcifique). 3) Blinking of orange LED 20 times: waiting for an update. 4) Activating default LED (fixed blue if no customer specific configuration. Prcautions d'installation Cautions for installation La tension dalimentation aux bornes du lecteur doit tre comprise entre +9 Vdc et
+15 Vdc. Eloigner, autant que possible, le lecteur des cbles de transmission informatique ou d'origine de puissance (secteur ou Haute Tension). Les perturbations quils peuvent engendrer varient en fonction de leur puissance de rayonnement et de leur proximit avec les lecteurs. Distance respecter entre 2 lecteurs :
Plans parallles : 30 cm - Mme plan : 40 cm - Plans perpendiculaires : 25 cm Si le lecteur est fix sur une surface mtallique, il est possible davoir une rduction de la distance de lecture. Utiliser une ferrite (2 passages) sur le cble (alimentation et donnes) Exemple : Rfrence 74271222 WURTH ELEKTRONIK. Brancher les fils et le connecteur du lecteur AVANT de mettre sous tension. Mettre hors tension avant de dbrancher les fils et/ou le connecteur du lecteur. Communication RS485 Vitesse de transmission Vitesse de transmission par dfaut Mode Nombre de bits Mode de transmission Bit de stop RS485 9600, 19200, 38400, 57600, 115200 bauds ARC R : 9600 ARC W : 38400(SSCP), 9600(OSDP) Asynchrone 8 LSB first 1 Adresse de diffusion par dfaut 00h Supply voltage at the readers connector should be between +9 Vdc and +15 Vdc. Keep away, as much as possible, the reader from computer or power source cables. They can generate an electrical perturbation dependent of their radiation level and of proximity to reader. Recommended distance between 2 readers:
Parallel plan: 30 cm Same plan: 40 cm Perpendicular plan: 25 cm. Reader installed on metallic surface may have reduced performances. Use a ferrite (2 ways) for the cable (Power supply and Data). Example: Reference 74271222 WURTH ELEKTRONIK Connect the wires and the connector of the reader BEFORE power on. Power off before disconnect the wires or the connector of the reader. Communication RS485 Baud rate 9600, 19200, 38400, 57600, 115200 bauds Default Baud rate Mode Number of bits Transfer mode Stop bit RS485 ARC R: 9600 ARC W: 38400(SSCP), 9600(OSDP) Asynchronous 8 LSB first 1 Default broadcast address 00h STid reserves the right to make change without notice, for the purpose of product improvement. STid 2017 20 PA des Pradeaux FR13850 Grasque NI1122A01 - 1 / 2 - Ed. 23/08/2017 Lecteurs ARCT 13.56 MHz Notice dinstallation ARCT 13.56 MHz readers Installation procedure Architecture en bus (RS485) Bus architecture (RS485) Le pr-cblage dans le lecteur des rsistances de 1.5 k (pull-up et pull-down) permet dutiliser des proprits tendues du BUS RS485 :FAIL-SAFE (cf. RS485-AN-960). RT : rsistance de fin de ligne de 120 fournie. The pre-wiring in the reader of the 1.5 k resistors (pull-up & pull-down) makes it possible to use extended features of the RS485 Bus: FAIL-SAFE (see RS485-AN-960). RT: End of line resistor of 120 supplied. Protocole de communication SSCP/SSCP2 SSCP/SSCP2 communication protocol Le lecteur ARCT-W33 accepte toutes les commandes SSCP/SSCP2 Lecteurs, les commandes de SCAN et Release de toutes les puces, les commandes Load SKB et Transceive. Le mode autonome et les commandes puce ne sont pas disponible. The ARCT-W33 reader accepts all Readers SSCP/SSCP2 commands, Scan and Release commands for all chips, LoadSKB and Transceive commands. Autonomous mode and chips commands are not available. Dimensions / Dimensions
*Visuels non-contractuels /
Non-contractual pictures Fixation / Mounting
-
-
-
-
-
-
Faire passer les cbles dans la cavit du socle. Fixer le socle sur son emplacement final. Effectuer le raccordement du lecteur. Tester le fonctionnement. Placer le lecteur sur le socle (clipper le haut puis pivoter le vers le bas). Fixer le lecteur laide des 2 vis et de lembout fourni. Dclaration de conformit
-
-
-
-
-
-
Pass the cables through the hole in the base. Screw the base to its final location. Connect the reader. Test the reading and communication. Place the reader on the base (clip the top part and then pivot it down). Lock the reader with the 2 provided screws using the specific tool. Declaration of compliance STid dclare que le lecteur ARCT- A est conforme aux exigences essentielles des Directives RED 2014/53/UE et Rohs 2011/65/UE. Une copie de notre dclaration est disponible sur demande adresse qualite@stid.com STid declares that the reader ARCT -A is compliant to the essential requirements of the Directives RED 2014/53/UE and Rohs 2011/65/UE. A copy of our declaration is available upon request to qualite@stid.com. Cet appareil est conforme la Part-15 de la FCC et la licence ISED sans RSSs. Son fonctionnement est soumis aux deux conditions suivantes :
1) Cet appareil ne doit pas causer dinterfrence nuisible. 2) Cet appareil doit accepter toute interfrence reue, y compris les interfrences pouvant provoquer un fonctionnement indsirable. Note : Le fabricant nest pas responsable des interfrences radio ou TV causes par des modifications non autorises de lquipement. De telles modifications pourraient annuler le droit lutilisateur dutiliser lquipement. Cet appareil est conforme aux exigences de scurit pour l'exposition aux RF en conformit avec RSS-
102 issue 5 pour les conditions d'utilisation. This device complies with Part 15 of the FCC rules and with ISEDs licenseexempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for potable use conditions. Adhrent DEEE Pro / DEEE Pro Adherent En rponse la rglementation, STid finance la filire de recyclage de Rcylum ddie aux DEEE Pro qui reprend gratuitement les matriels lectriques dclairage, les quipements de contrle et de surveillance, et les dispositifs mdicaux usags. Plus dinformations sur www.recylum.com. In response to the regulation, STid finances the Rcylum dedicated to DEEE Pro recycling chain. Lighting electrical equipment, control and monitoring devices, and used medical devices are taken back free of charge. More information on www.recylum.com. STid reserves the right to make change without notice, for the purpose of product improvement. STid 2017 20 PA des Pradeaux FR13850 Grasque NI1122A01 - 2 / 2 - Ed. 23/08/2017