Sortie cble / Outputs :
50cm ref. A & C 3 m ref. B & D Mini lecteur de proximit 125 kHz Notice dinstallation Mini proximity reader 125 kHz Installation procedure Sortie cble Outputs Marron / Brown Rouge / Red Gris / Grey Bleu / Blue Jaune / Yellow Vert / Green Type R31 (Wiegand) 0 Vdc
+12 VDC Data 0 Data 1 Clock Led Verte / Green Orange Led Rouge / Red Led Led Type R31 (Clock &
Data) 0Vdc
+12 VDC Code Data Clock Led Verte / Green Led Led Rouge / Red Led Rfrences des produits / Product references LXM-R11-A-E01-xx LXM-R11-B-E01-xx LXM-R11-C-H01-xx LXM-R11-D-H01-xx Type de cble prconis Recommended cables Utiliser un cble multiconducteur blind par tresse. Dans le cas d'une tl-
alimentation, utiliser :
Use a multi-conductor cable, pair shielded. When power is supplied with the same cable we recommend:
1 paire 6/10 jusqu' 30 m 2 paires 6/10 jusqu' 60 m 3 paires 6/10 jusqu' 100 m 1 paire 9/10 jusqu' 50 m 2 paires 9/10 jusqu' 100 m Buzzer / LED 1 pair AWG24 for up to 30 m 2 pairs AWG24 for up to 60 m 3 pairs AWG24 for up to 100 m 1 pair AWG35 for up to 50 m 2 pairs AWG35 for up to 100 m Buzzer / LED A la mise sous tension du lecteur, la LED est active sur la couleur orange. Elle peut tre commande par le systme distant pour sallumer verte ou rouge, en ramenant un contact 0V respectivement sur les entres du bornier Vert ou Rouge. Le buzzer donne une indication de lecture correcte, indpendante des autorisations pouvant tre lies au badge. Il fonctionnera ds quun badge sera lu. When the reader is switched on, the orange LED is activated. It can be driven by the remote system to light it either red or green, by bringing a 0V respectively on the red or green inputs of the readers connector. The buzzer gives an indication of correct read, not depending on the eventual authorizations or access rights given to a card. It will emit a brief sound as soon as a card or tag is read. Fixation Effectuer le raccordement du lecteur. Tester le fonctionnement. Utiliser des vis max 3 mm (entre axes de 104 mm). Placer les caches vis. Pull-up intgrs Installation Connect the reader. Test the reading and communication. Use screws max 0.1378 in / 3 mm. (Over Locknut Distance: 104 mm) Install the screw caps. Pull-ups resistors Des rsistances de pulls-up de 10k au Vin (tension dalimentation du lecteur) sont pr quipes dans llectronique du lecteur. For Data signals, 10k pull-up resistors are connected internally to Vin (power supply voltage). Prcautions dinstallation Precautions for installation La tension de l'alimentation aux bornes du lecteur doit tre comprise entre +9 Vdc et +15 Vdc. Eloigner autant que possible le lecteur des cbles de transmission informatique ou d'origine de puissance (secteur ou Haute Tension). Les perturbations quils peuvent engendrer peuvent varier en fonction de leur puissance de rayonnement et de leur proximit des lecteurs. Distance respecter entre deux lecteurs: plans parallle : 30 cm - mme plan :
40 cm - plan perpendiculaire : 25 cm. Si le lecteur est fix sur une surface mtallique, il est possible davoir une rduction de la distance de lecture. Pour obtenir la distance maximale de lecture, le lecteur doit tre install au moins 7 cm de toute surface mtallique. Filtrage Par dfaut, lorsque cette entre nest pas connecte, le lecteur temporise la lecture lorsquun mme badge reste dans le champ du lecteur le code du badge nest transmis que toutes les deux secondes. Cependant, ds quun badge diffrent est prsent au lecteur, il est immdiatement lu. Pour annuler le filtrage, il faut connecter les deux points de cette entre comme indiqu sur le schma ci-dessous :
1. Dbrancher l'alimentation du lecteur. 2. Effectuer la connexion de l'entre Mode (par ex : avec un fil). 3. Rebrancher l'alimentation. Vrifier le fonctionnement en prsentant une carte devant le lecteur qui doit mettre un Bip chaque lecture. 4. Dbrancher l'alimentation, retirer le fil de l'entre Mode et rebrancher l'alimentation. A prsent, si une mme carte est maintenue devant le lecteur la lecture se fera toutes les deux secondes environ. Power supply tension at the readers connector should be strictly comprised between +9 Vdc and +15 Vdc. Keep the reader away from computer or power cables as much as possible. They can generate an electrical perturbation that is function of their proximity and radiation level. Distance to respect between two readers: parallel plan: 30 cm Same plan: 40 cm Perpendicular: 25 cm. If the reader is mounted on a metallic surface it can affect the reading distance. To get the maximum reading distance, the reader should be installed at no less than 7 cm from any metallic surface. Filter By default, when this input is not connected, the reader will automatically delay the transmission of the code every 2 seconds. If a new card is shown to the reader before this time laps, its code will be transmitted immediately. To cancel the filter, you must connect two points in the internal connector, as indicated on the drawing above:
1. Power off the reader. 2. Connect the filter cancellation strap (with a little wire). 3. Power on the reader. Check if the reader is operating properly by presenting a card. The reader should then beep quickly on each reading. 4. To come back to the initial configuration, power off the reader, then unplug the strap. Power the reader on. Now, when a card is left in the reading area, the reader will beep only every two seconds. Fixation Installation Effectuer le raccordement du lecteur. Tester le fonctionnement. Fixer le lecteur au mur laide de vis type M3 maximum. Une fois mont et test, placer le capot avant et clipper lensemble. Connect the reader. Test the reading and communication. Attach the reader on the wall (M3 screws only). Place the front cover and clip it. Dimension STid 20 PA des Pradeaux FR13850 Grasque NI1021A05 - Ed. 07/02/2018 Mini lecteur de proximit 125 kHz Notice dinstallation Mini proximity reader 125 kHz Installation procedure Dclaration de conformit Declaration of compliance STid dclare que le lecteur LXM est conforme aux exigences essentielles des Directives RED 2014/53/UE et Rohs 2011/65/UE. Une copie de notre dclaration est disponible sur demande adresse qualite@stid.com STid declares that the reader LXM is compliant to the essential requirements of the Directives RED 2014/53/UE and Rohs 2011/65/UE. A copy of our declaration is available upon request to qualite@stid.com. Cet appareil est conforme la Part-15 de la FCC. Son fonctionnement est soumis aux deux conditions suivantes :
1) Cet appareil ne doit pas causer dinterfrence nuisible. 2) Cet appareil doit accepter toute interfrence reue, y compris les interfrences pouvant provoquer un fonctionnement indsirable. Note : Le fabricant nest pas responsable des interfrences radio ou TV causes par des modifications non autorises de lquipement. De telles modifications pourraient annuler le droit lutilisateur dutiliser lquipement. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. Adhrent DEEE Pro / DEEE Pro Adherent En rponse la rglementation, STid finance la filire de recyclage de Rcylum ddie aux DEEE Pro qui reprend gratuitement les matriels lectriques dclairage, les quipements de contrle et de surveillance, et les dispositifs mdicaux usags. Plus dinformations sur www.recylum.com. In response to the regulation, STid finances the Rcylum dedicated to DEEE Pro recycling chain. Lighting electrical equipment, control and monitoring devices, and used medical devices are taken back free of charge. More information on www.recylum.com STid 20 PA des Pradeaux FR13850 Grasque NI1021A05 - Ed. 07/02/2018