all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.19 MiB | January 03 2019 | |||
1 | Cover Letter(s) | January 03 2019 | ||||||
1 | Cover Letter(s) | January 03 2019 | ||||||
1 | Cover Letter(s) | January 03 2019 | ||||||
1 | External Photos | January 03 2019 | ||||||
1 | Internal Photos | January 03 2019 | ||||||
1 | ID Label/Location Info | January 03 2019 | ||||||
1 | Test Report | May 03 2019 / January 03 2019 | ||||||
1 | Test Setup Photos | January 03 2019 |
1 | User Manual | Users Manual | 3.19 MiB | January 03 2019 |
Installation procedure Notice dinstallation Manual de instalacin SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES SPECTRE Module Access - SMA SPECTRE Reader Access - SLA Frequency Band: 865 - 868 MHz Frequency Band: 902 - 928 MHz SMA-R41-A-U04: TTL SMA-R42-A-U04: RS232 SMA-R43-A-U04: RS485 SMA-R51-A-U04: TTL SMA-R52-A-U04: RS232 SMA-R53-A-U04: RS485 Frequency Band: 865 - 868 MHz Frequency Band: 902 - 928 MHz SLA-R41-A-U04: TTL SLA-R42-A-U04: RS232 SLA-R43-A-U04: RS485 SLA-R51-A-U04: TTL SLA-R52-A-U04: RS232 SLA-R53-A-U04: RS485 Power Supply Characteristics - SMA /SLA Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for an eventual V+/V-. Main power supply: Range +9 Vdc up to +36 Vdc Consumption:
Typical: 12 Vdc Max: 1.5A under +12 Vdc Typical: 1A under +12 Vdc Characteristics - SMA / SLA Communication:
Pin out:
Temperature:
Protection:
Chip:
I/O:
Module LED:
Antenna LED:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data) Removable connectors 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in
-25 to +60 C / -13 to +140 F IP66 level EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max 4 optocoupled inputs and 4 optocoupled outputs 1 red LED: presence of power supply and 1 green LED: activity on Reader / host link 7 configurable colors (red, green, blue, orange, purple, turquoise, white) Recommended Cables - SMA / SLA Use a multi-conductor shielded twisted pair cable. Max length RS485:
Max length RS232:
Wiegand / Clock & Data:
3 280.84 ft / 1000 m at 9600 baud. 49.21 ft / 15 m. 1 pair AWG24 30 m / 98.43 ft max 1 pair AWG20 50 m / 164.04 ft max 2 pairs AWG20 100 m / 328.08 ft max 2 pairs AWG24 60 m / 196.85 ft max 3 pairs AWG24 100 m / 328.08 ft max Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector). The disruptions that they can cause can vary according to their radiation power and their proximity. Use a filtered and regulated power supply. Antennas connected to different modules/readers may interfere with each other. Move them away from each other. A power supply which provides 1.5 A min under +12Vdc is recommended. If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply. Recommendations - SMA / SLA Users must not remain within a range of less than, 25 cm / 9.84 in from an antenna for an extended period of time as per EN50364 applicable to this type of device. Apart from the hatch the module housings must not be opened. Before any service operation you must de-energize reader. Check that the hatch seal is correctly positioned before closing. Do not remove the caps of unused Do not remove the caps from the unused Install the module/reader with the word UP cable glands:
RF connectors:
facing upwards so that the connectors are down:
Host Connection Access - SMA / SLA In order to access the module/reader connectors, open only the hatch provided for this purpose by unscrewing the 4 captive screws without removing them from the hatch. Cable glands (Data Bus-Power sup. - Input/Output) Front View of the Module - SMA / SLA Green LED Red LED RF port 2 RF port 4 RF port 1 RF port 3 STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 1 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES J6 J9 J7 J14 TTL / RS232 / RS485 / I/O Connection - SMA / SLA Use this (on RS485 connection) when the distance of the data cable is near or over 100 m / 328.08 ft and the signal is weakened (polluted signals, frame errors etc.). End of line resistor RS485 TTL output level: +5V or Vin Micro USB connector for configuration purposes only Use this connector for earth connection purpose IN 1-2-3-4 OUT 1-2-3-4 V- opt V+ opt DATA1 CLK1 DATA 2 / CLK2 DATA 3 / CLK3 DATA 4 / CLK4 ALIM GND 4 opto-coupled inputs 4 opto-coupled outputs Low polarization potential of opto-coupled inputs and outputs High polarization potential of opto-coupled inputs and outputs Data or D0 Channel 1 or Tx (RS232) or L+ (RS485) Clock or D1 Channel 1 or Rx (RS232) or L- (RS485) Data/Clock or D0/D1 Channel 2 Data/Clock or D0/D1 Channel 3 Data/Clock or D0/D1 Channel 4 Power supply GND Configuration - SMA / SLA The number of antennas, the number of channels and the communication protocol are configurable with the Ultrys V2 application or when the module is ordered. TTL protocols (Wiegand & ISO2):
- ISO2 (Clock & Data) - Decimal (7 bytes max)
- Wiegand 26-bit
- Wiegand with LRC - Hexadecimal (12 bytes max) + LRC
- Wiegand without LRC - Hexadecimal (12 bytes max) Serial protocols (RS232 & RS485): The structure of the frame can be configured with the following optional parameters (in gray):
1 byte STX 0x02 1 byte + X bytes Channel number + Tag Data*
0x0y nn..nn 1 byte LRC 1 byte CR 0x0D 1 byte LF 0x0A 1 byte ETX 0x03
- STX+ETX: add 0x02 (STX) and 0x03 (ETX) at the start /end of frame
- CR/LF: Carriage Return (0x0D + 0x0A) configurable separately
- LRC: Checksum (XOR of all previously bytes except STX)
- Data sent in: decimal or hexadecimal
- ASCII: if this option is activated, the data will be sent in ASCII mode (data size will be doubled).
- Non-significant zero: complete the tag data with not significant 0 to obtain the defined data size.
(Channel no. + 0 padding + tag data, etc.) When the reader is switched on: the readers red LED lights up. Reader initializing. After initializing, the reader will look for a configuration tag for about 15 s, on antenna 1 (connected to RF port 1). Start Sequence - SMA / SLA If no tag detected: the antenna LED flashes color RFON (200ms) (blue by default) / RFOFF (200ms). If any tag is detected: the antenna LED displays the sequence color RFON (blue by default) / color DETECTION (orange by default) for 200ms then LED OFF. If a configuration tag is detected: the antenna LED displays the sequence color RFON (blue by default) / color DETECTION (orange by default) for 200ms then LED OFF then the antenna LED gives the followings indications:
-
-
-
-
3 GREEN flashes (500ms ON; 200ms OFF): the configuration tag is taken into account. 3 RED flashes (500ms ON; 200ms OFF): the regulation (region) of the configuration tag does not match to the regulation of the reader. 3 PURPLE flashes (500ms ON; 200ms OFF): the key of the configuration tag does match to the reader key. 5 RED flashes (500ms ON; 200ms OFF): the model of the reader of the configuration tag does match to the model of the reader. The end of the start sequence is indicated by the flashing of the reader LEDs (red and green) 3 times (500ms ON; 500ms OFF). STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 2 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Dimensions (mm/in) - SMA Mounting - SMA Two mounting possibilities:
Adjustable wall-mounted kit
(refer to the Installation Procedures for KFX-UHF-08) Wall Adjustable pole-mounted kit
(refer to the Installation Procedures for KFX-UHF-09) Pole Mount with a 75 x 75 mm / 0.79 x 0.79 in VESA standard mounting bracket M4x12 stainless steel screws provided with mounting kit) Or mount directly on a wall 4x35 aluminum screws provided (TCL ALU 4x12). An antenna must be connected to the RF port 1 (closed to the LEDs). Antenna Connection - SMA 4 serializable cable lengths are available:
1.5 m /4.92 ft: CAB-SPECTRE-1.5M 3 m / 9.84 ft: CAB-SPECTRE-3M 9 m / 29.53 ft: CAB-SPECTRE-9M 12 m / 39.37 ft: CAB-SPECTRE-12M Only possible combinations:
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M RF Port 1 STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 3 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES
-
-
-
Mounting an Antenna on Module - SLA Attach the antenna on the module with the 4 screws (TCL ALU M4x12) provided with the module. Remove the cap from port RF 1. Connect the antenna to port RF 1 of the module. Reader Dimensions (mm / in) - SLA Antenna must be connected to RF Port 1 Mount with 75 x 75 mm / 0.79 x 0.79 in Standard VESA mounting bracket M4x12 polier screws provided with mounting kit) Mounting - SLA Two mounting possibilities:
Adjustable wall-mounted kit
(refer to the Installation Procedures for KFX-UHF-08) Wall Adjustable pole-mounted kit
(refer to the Installation Procedures for KFX-UHF-09) Pole Antenna Connection - SLA 4 serializable cable lengths are available:
1.5 m /4.92 ft: CAB-SPECTRE-1.5M 3 m / 9.84 ft: CAB-SPECTRE-3M 9 m / 29.53 ft: CAB-SPECTRE-9M 12 m / 39.37 ft: CAB-SPECTRE-12M Only possible combinations:
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M The antenna cables have a male connector and a female connector. Label Antenna Cables SMA / SLA To antenna To module US FR ES STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 4 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin Antenna Specifications - ANT-UHF-V2 ANT-UHF2-A for SMA/SLA-R4x 865 - 868 MHz 8.30 dBi Circular 0.66 70 50 ohms TNC RP male Level IP66 ANT-UHF2-B for SMA/SLA-R5x 902 - 928 MHz 9.38 dBi Circular 1.16 60 50 ohms TNC RP male Level IP66 348.7 / 13.73 9 9 0 1
.
/
. 2 9 7 2 Frequency Band Antenna gain Polarization Axial ratio Beamwidth (-3 dB) Impedance Cable Protection Mount with 75 x 75 mm / 0.79 x 0.79 in Standard VESA mounting bracket (M4x12 stainless steel screws provided with mounting kit) 45.1 / 1.78 in Antenna Mounting Two mounting possibilities:
Adjustable wall-mounted kit
(refer to the Installation Procedures for KFX-UHF-08) Wall Adjustable ole-mounted kit
(refer to the Installation Procedures for KFX-UHF-09) Pole Horizontal polarization F = 867 MHz Horizontal polarization F = 915 MHz Vertical polarization F = 867 MHz Vertical polarization F = 915 MHz Azimuth pattern STid declares that the SMA-R5x/R4x-A reader is compliant to the fundamental requirements of Directive RED 2014/53/EU and Directive RoHs 2011/65/EU and Commission Delegated Directive 2015/863/EU. A copy of our declaration is available upon request send to qualite@stid.com. Declaration of Compliance This device complies with Part 15 of the FCC rules and with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
1) This device must not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can emit radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-
-
-
Reorient or relocate the receiving antenna. Increase the distance between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for assistance. This equipment complies with FCCs radiation exposure limits set forth for an uncontrolled environment under the following conditions:
-
-
-
This equipment should be installed and operated such that a minimum separation distance of 25 cm / 9.84 in is maintained between the radiator (antenna) and the users/nearby persons body at all times. The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. DEEE Pro Member In response to the regulation, STid finances the Rcylum recycling program dedicated to DEEE Pro. Electrical lighting equipment, control and monitoring devices, and used medical devices are recycled free of charge. More information at www.recylum.com. STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 5 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Module Access SPECTRE - SMA Lecteur SPECTRE - SLA Bande de frquences : 865 - 868 MHz Bande de frquences : 902 - 928 MHz SMA-R41-A-U04 : TTL SMA-R42-A-U04 : RS232 SMA-R43-A-U04 : RS485 SMA-R51-A-U04 : TTL SMA-R52-A-U04 : RS232 SMA-R53-A-U04 : RS485 Bande de frquences : 865 - 868 MHz Bande de frquences : 902 - 928 MHz Caractristiques de lalimentation - SMA / SLA SLA-R41-A-U04 : TTL SLA-R42-A-U04 : RS232 SLA-R43-A-U04 : RS485 SLA-R51-A-U04 : TTL SLA-R52-A-U04 : RS232 SLA-R53-A-U04 : RS485 Utiliser une alimentation AC/DC du type LPS, Source Puissance Limite (selon IEC EN 60950-1 Ed2) ou de type ES1, PS1 (selon IEC EN 62368-1) pour lalimentation principale et pour un ventuel V+/V-. Alimentation principale : Gamme +9 Vdc +36 Vdc Consommation :
Typique : +12 Vdc Max: 1.5A sous +12 Vdc Typique : 1A sous +12 Vdc Caractristiques - SMA / SLA RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data) Borniers dbrochables vis 3x4 points et 1x8 points, Pas de 3,81 mm Communication :
Raccordement :
T de fonctionnement : -25 C / +60C Indice de protection : Niveau IP66 Puce lue :
I/O :
LEDs sur module :
LEDs sur antenne : 7 couleurs configurables (rouge, vert, bleu, orange, violet, turquoise, blanc) EPC1 Gen2 (ISO 18000-63) - 1 62 octets max 4 entres et 4 sorties opto-couples 1 LED rouge : prsence tension dalimenttion 1 LED verte : activit sur la liaison Lecteur / Host Type de cble prconis - SMA / SLA Utiliser du cble multiconducteur blind par tresse, relie la masse du concentrateur. Dport max RS485 : 1000 m. 9600 bauds Dport max RS232 : 15 m. Wiegand / Clock & Data :
1 paire 6/10 - 30 m max 1 paire 9/10 - 50 m max 2 paires 6/10 - 60 m max 2 paires 9/10 - 100 m max 3 paires 6/10 - 100 m max Recommendations - SMA / SLA Installer le module distance des cbles de transmission informatique ou dorigine de puissance (ex : RJ45, secteur...). Les perturbations quils peuvent engendrer peuvent varier en fonction de leur puissance de rayonnement et de leur proximit. Utiliser une alimentation filtre et rgule. Des antennes connectes des lecteurs diffrents peuvent se perturber. Eloigner les, les unes des autres. Il est recommand dutiliser une alimentation 1,5 A minimum sous +12Vdc. Si les IN/OUT sont aliments par le module utiliser une alimentation de 2A min sous +12Vdc. Un utilisateur ne doit pas se trouver de manire prolonge, une distance infrieure 25 cm dune antenne conformment aux prconisations de la norme EN50364 applicable ce type dappareil. Installer le module en respectant la signaltique UP vers le haut afin que les connectiques soient vers le bas : :
Il est proscrit douvrir le botier module mis part la trappe. Avant toute opration de service, vous devez mettre le lecteur hors tension. Sassurer que le joint de trappe est bien positionn avant fermeture. Ne pas retirer les bouchons des presse-
Ne pas retirer les capuchons des connecteurs RF non-utiliss :
toupes non-utiliss :
Accs la connectique - SMA / SLA Afin daccder la connectique du lecteur, ouvrir uniquement la trappe prvue cet effet en dvissant les 4 vis imperdables sans les ter de la trappe. Presse toupes (Bus Donnes- Alimentation-entres/sorties) Vue de face du module - SMA / SLA LED verte LED rouge Port RF 2 Port RF 4 Port RF 1 Port RF 3 STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 6 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES J6 J9 J7 J14 Connexion TTL / RS232 / RS485 / I/O - SMA / SLA Rsistance de fin de lignes RS485 A utiliser, lors dune communication RS485, lorsque la distance de cble de donnes approche ou est suprieure 100 m et que la communication se dgrade (signaux non francs, erreurs de trames etc.) Niveau sortie TTL : +5V ou Vin Connecteur micro USB pour configuration uniquement Utiliser ce connecteur pour la connexion la terre IN 1-2-3-4 OUT 1-2-3-4 V- opt V+ opt DATA1 CLK1 DATA 2 / CLK2 DATA 3 / CLK3 DATA 4 / CLK4 ALIM GND 4 Entres opto-couples 4 Sorties opto-couples Potentiel de polarisation bas des entres et sorties opto-couples Potentiel de polarisation haut des entres et sorties opto-couples Data ou D0 de la voie 1 ou Tx (RS232) ou L+ (RS485) Clock ou D1 de la voie 1 ou Rx (RS232) ou L-(RS485) Data/Clock ou D0/D1 de la voie 2 Data/Clock ou D0/D1 de la voie 3 Data/Clock ou D0/D1 de la voie 4 Alimentation GND Configuration - SMA / SLA Le nombre dantenne, le nombre de voie, le protocole de communication sont configurables via lapplication Ultrys V2 ou lors de la commande du module. Protocoles TTL (Wiegand & ISO2) :
- ISO2 (Clock & Data) Dcimal (7 octets max).
- Wiegand 26 bits
- Wiegand avec LRC Hexadcimal (12 octets max) + LRC.
- Wiegand sans LRC Hexadcimal (12 octets max). Protocoles srie (RS232 & RS485) : Il est possible de configurer la structure de la trame avec les paramtres optionnels suivants (griss). 1 octet STX 0x02 1 octet + X octets Numro de Voie + Tag Data*
0x0y nn..nn 1 octet LRC 1 octet CR 0x0D 1 octet LF 0x0A 1 octet ETX 0x03
- STX+ETX : ajout dun 0x02 (STX) et 0x03 (ETX) en dbut et fin de trame
- CR/LF : retour chariot (0x0D + 0x0A) configurable sparment
- LRC : octet de contrle (XOR de tous les octets prcdents hormis STX)
- Donnes transmises en dcimal ou hexadcimal
- ASCII : si cette option est active, les donnes incluses dans la trame seront au format ASCII (la taille des donnes du tag lu sera alors double).
- Zros non-significatifs : complte les donnes du tag avec des 0 non significatifs pour obtenir la taille de donnes dfinie.
(Voie n + Zro de bourrage + Donnes du tag...). A la mise sous tension : la LED lecteur rouge sallume. Initialisation du lecteur. Aprs linitialisation, le lecteur recherche un tag de configuration pendant environ 15s sur lantenne 1 (connecte au port RF 1). Squence de dmarrage - SMA / SLA Si pas de tag dtect : clignotement de la LED antenne couleur RFON (200 ms) (par dfaut bleu) / RFOFF (200ms). Si dtection dun tag quelconque : la LED antenne enchane la squence couleur RFON (par dfaut bleu) / couleur DETECTION (par dfaut orange) pendant 200ms puis LED OFF. Si dtection dun tag de configuration : la LED antenne enchane la squence couleur RFON (par dfaut bleu) / couleur DETECTION (par dfaut orange) pendant 200ms puis LED OFF puis la LED antenne donne les indications suivantes :
-
-
3 clignotements de couleur VERT (500ms ON ; 200ms OFF) : prise en compte du tag de configuration OK. 3 clignotements de couleur ROUGE (500ms ON ; 200ms OFF) : la rgulation (rgion) du tag de configuration ne correspond pas la rgulation du lecteur. 3 clignotements de couleur VIOLET (500ms ON ; 200ms OFF) : la cl du tag de configuration ne correspond pas la cl du lecteur. 5 clignotements de couleur ROUGE (500ms ON ; 200ms OFF) : le modle de lecteur du tag de configuration ne correspond pas au modle du lecteur.
-
-
La fin de la squence de dmarrage est indique par le clignotement des LEDs lecteur (rouge et verte) 3 fois (500ms ON ; 500ms OFF). STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 7 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Dimensions (mm) - SMA Fixation - SMA Deux modes de fixation possibles :
Kit de fixation murale orientable
(se rfrer la Notice dinstallation du KFX-UHF-08) Mur Kit de fixation mt orientable
(se rfrer la Notice dinstallation du KFX-UHF-09) Mt 4 longueurs de cbles srialisables sont disponibles :
1,5 m : CAB-SPECTRE-1.5M 3 m : CAB-SPECTRE-3M 9 m : CAB-SPECTRE-9M 12 m : CAB-SPECTRE-12M Les seules combinaisons possibles sont :
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M 1- Fixation avec un support de fixation de type VESA 2-
standard 75x75 mm (vis M4x12 Inox fournies dans le kit de fixation) 3-
Ou Fixation directement sur un mur Vis 4x35 inoxydable recommande. Port RF 1 Il est impratif de raccorder une antenne sur le port RF 1 (le plus proche des LEDs). Raccordement antennes - SMA STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 8 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES
-
-
-
Fixation dune antenne sur le module - SLA Fixer lantenne sur le module SMA laide des 4 vis (TCL ALU M4x12) fournies avec le module. Retirer le capuchon du port RF 1. Raccorder lantenne au port RF 1 du module. Fixation avec un support de fixation de type VESA standard 75x75 mm (vis M4x12 Inox fournies dans le kit de fixation) Dimensions (mm) - SLA Il est impratif de raccorder une antenne au Port RF 1 Fixation - SLA Deux modes de fixation possibles :
Kit de fixation murale orientable
(se rfrer la Notice dinstallation du KFX-UHF-08) Mur Kit de fixation mt orientable
(se rfrer la Notice dinstallation du KFX-UHF-09) Mt Raccordement antenne(s) - SLA 4 longueurs de cbles srialisables sont disponibles :
1,5 m : CAB-SPECTRE-1.5M 3 m : CAB-SPECTRE-3M 9 m : CAB-SPECTRE-9M 12 m : CAB-SPECTRE-12M Les seules combinaisons possibles sont :
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M Cbles antennes SMA / SLA Les cbles antenne possdent 1 connecteur mle et un connecteur femelle. Etiquette Vers antenne Vers module STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 9 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin Spcifications antennes - ANT-UHF-V2 ANT-UHF2-A pour SMA/SLA-R4x 865 - 868 MHz 8.30 dBi Circulaire 0.66 70 50 ohms TNC RP mle Niveau IP66 ANT-UHF2-B pour SMA/SLA-R5x 902 - 928 MHz 9.38 dBi Circulaire 1.16 60 50 ohms TNC RP mle Niveau IP66 Bande de frquences Gain de lantenne Polarisation Ratio Axial Angle douverture (-3 dB) Impdance Cble Protection US FR ES Fixation avec un support de fixation de type VESA standard 75x75 mm (vis M4x12 Inox fournies dans le kit de fixation) Fixation des antennes Deux modes de fixation possibles :
Kit de fixation murale orientable
(se rfrer la Notice dinstallation du KFX-UHF-08) Kit de fixation mt orientable
(se rfrer la Notice dinstallation du KFX-UHF-09) Mur Mt Mesures en Azimut Polarisation horizontale F = 867 MHz Polarisation horizontale F = 915 MHz Polarisation verticale F = 867 MHz Polarisation verticale F = 915 MHz Dclaration de conformit STid dclare que les lecteurs SMA-R5x/R4x-A sont conforme aux exigences essentielles de la Directive RED 2014/53/UE et RoHs 2011/65/UE et Directive dlgue 2015/863/UE. Une copie de notre dclaration est disponible sur demande adresse qualite@stid.com. Cet appareil est conforme la Part-15 de la FCC et aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes :
1) Cet appareil ne doit pas causer dinterfrence nuisible. 2) Cet appareil doit accepter toute interfrence reue, y compris les interfrences pouvant provoquer un fonctionnement indsirable. Note : Le fabricant nest pas responsable des interfrences radio ou TV causes par des modifications non autorises de lquipement. De telles modifications pourraient annuler le droit lutilisateur dutiliser lquipement. Cet quipement a t test et dclar conforme aux limites imposes aux priphriques numriques de classe B stipules au chapitre 15 du rglement FCC. Ces limites sont conues pour fournir une protection raisonnable contre les interfrences nuisibles lorsque lquipement est utilis dans un environnement rsidentiel. Cet quipement gnre, utilise et peut mettre des frquences radio et, sil nest pas install et utilis conformment aux instructions, peut crer des interfrences nuisibles perturbant les communications radio. Toutefois, rien ne permet de garantir labsence totale dinterfrence dans une installation donne. Si lquipement perturbe la rception de radios ou de tlvisions, ce qui peut tre vrifi en teignant et en rallumant lquipement, lutilisateur est invit tenter de faire disparatre ces interfrences en recourant lune des mesures suivantes :
-
-
-
rorienter ou dplacer lantenne de rception ;
augmenter lcart entre lquipement et le rcepteur ;
brancher lquipement sur une prise situe sur un circuit autre que celui auquel est raccord le rcepteur ;
Consulter le revendeur ou un technicien expriment pour obtenir de laide. Cet quipement est conforme aux limites dexposition aux rayonnements de la FCC tablies pour un environnement non contrl dans les conditions suivantes :
-
-
Il doit tre install et utilis avec un minimum de 25 cm de distance entre la source de rayonnement et votre corps. Le transmetteur ne doit pas tre plac ct ou ne doit pas fonctionner avec une autre antenne ou un autre transmetteur. Adhrent DEEE Pro En rponse la rglementation, STid finance la filire de recyclage de Rcylum ddie aux DEEE Pro qui reprend gratuitement les matriels lectriques dclairage, les quipements de contrle et de surveillance, et les dispositifs mdicaux usags. Plus dinformations sur www.recylum.com STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 10 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Mdulo de Acceso SPECTRE - SMA Lector SPECTRE - SLA Banda de frecuencias: 865 - 868 MHz Banda de frecuencias: 902 - 928 MHz SMA-R41-A-U04: TTL SMA-R42-A-U04: RS232 SMA-R43-A-U04: RS485 SMA-R51-A-U04: TTL SMA-R52-A-U04: RS232 SMA-R53-A-U04: RS485 Banda de frecuencias: 865 - 868 MHz Banda de frecuencias: 902 - 928 MHz Caractersticas de alimentacin - SMA / SLA SLA-R41-A-U04: TTL SLA -R42-A-U04: RS232 SLA -R43-A-U04: RS485 SLA -R51-A-U04: TTL SLA -R52-A-U04: RS232 SLA -R53-A-U04: RS485 Utilizar una alimentacin AC/DC de tipo LPS, Fuente con Potencia Limitada (segn IEC EN 60950-1 Ed2) o de tipo ES1, PS1 (segn IEC EN 62368-1) para el suministro principal y para un eventual V + / V-. Main power supply: +9 Vdc a +36 Vdc Consumo:
Tpico: +12 Vdc Mximo: 1.5A con +12 Vdc Tpico: 1A con +12 Vdc Caractersticas - SMA / SLA RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data) Regleta de terminales extrables con tornillos 3x4 puntos y 1x8 puntos, Paso de 3.81 mm / 0.149 in Comunicacin:
Conexin:
T de funcionamiento: De -25 C a +60C / de -13 a +140 F ndice de proteccin: Nivel IP66 Chip ledo:
I/O:
LEDs en el mdulo: 1 LED rojo: presencia de tensin de alimentacin y 1 LED verde: actividad en conexin Lector / Host LEDs en antena:
EPC1 Gen2 (ISO 18000-63) - 1 a 62 octetos mx. 4 entradas y 4 salidas optoacopladas 7 colores configurables (rojo, verde, azul, naranja, lila, turquesa, blanco) Tipo de cable recomendado - SMA / SLA Utilizar cable multiconductor blindado por trenza, conectado a la masa del concentrador. Desvo mx. RS485: 3 280.84 ft / 1000. a 9600 baudios Desvo mx. RS232: 49.21 ft / 15 m. Wiegand / Clock & Data:
1 par 6/10 - 30 m / 98.43 ft mx. 1 par 9/10 - 50 m / 164.04 ft mx. 2 pares 6/10 - 60 m / 196.85 ft mx. 2 pares 9/10 - 100 m / 328.08 ft mx. 3 pares 6/10 - 100 m / 328.08 ft mx. Instalar el mdulo a distancia de los cables de transmisin informtica o de origen de potencia (Ej.: RJ45, sector...). Las perturbaciones que pueden generar dependen de su potencia de radiacin y de su proximidad. Recomendaciones - SMA / SLA Usar una alimentacin filtrada y regulada. Antenas conectadas a lectores diferentes pueden alterarse. Alejarlas entre ellas. Se recomienda usar una alimentacin 1,5 A mnimo en +12Vcc. Si los IN/OUT estn alimentados por el mdulo, usar una alimentacin de 2A min en +12Vcc. Un usuario no debe encontrarse de forma prolongada, a una distancia inferior a 25 cm / 9.84 in de una antena, de acuerdo con las recomendaciones de la norma EN50364 aplicable a este tipo de aparatos. Est desaconsejado abrir la caja del mdulo, excepto la trampilla. Antes de cualquier operacin de mantenimiento, debe desconectar el lector Asegurarse de que la junta de la trampilla est bien colocada, antes de cerrarla. No quitar los tampones de las prensaestopas no utilizadas:
No quitar las cpsulas de cierre de los conectores RF no utilizados:
Instalar el mdulo cumpliendo con la sealizacin UP hacia arriba para que las conexiones estn hacia arriba:
Acceso al sistema de conexin - SMA / SLA Para acceder al sistema de conexin del lector, abrir solamente la trampilla prevista a tal efecto, desatornillando los 4 tornillos imperdibles sin quitarlos de la trampilla. Prensaestopas (Bus Datos- Alimentacin-entradas/salidas) Vista frontal del mdulo - SMA / SLA LED verde LED rojo Puerto RF 2 Puerto RF 4 Puerto RF 1 Puerto RF 3 STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 11 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Conexin TTL / RS232 / RS485 / I/O - SMA / SLA Resistencia de fin de lneas RS485 J6 Utilizar en una comunicacin RS485, cuando la distancia del cable de datos se acerca o es superior a 100 m / 328.08 ft y que la comunicacin se deteriora (seales no claras, errores de tramas, etc.) J9 J7 J14 Nivel salida TTL: +5V o Vin Conector micro USB solo para configuracin Utilizar para conexin a la tierra IN 1-2-3-4 OUT 1-2-3-4 V- opt V+ opt DATA1 CLK1 DATA 2 / CLK2 DATA 3 / CLK3 DATA 4 / CLK4 ALIM GND 4 Entradas optoacopladas 4 Salidas optoacopladas Potencial de polarizacin bajo de las entradas y salidas optoacopladas Potencial de polarizacin alto de las entradas y salidas optoacopladas Data o D0 de la va 1 o Tx (RS232) o L+ (RS485) Clock o D1 de la va 1 o Rx (RS232) o L-(RS485) Data/Clock o D0/D1 de la va 2 Data/Clock o D0/D1 de la va 3 Data/Clock o D0/D1 de la va 4 Alimentacin GND Configuracin - SMA / SLA El nmero de antenas, el nmero de vas, el protocolo de comunicacin se pueden configurar mediante la aplicacin Ultrys V2 o al realizar el pedido del mdulo. Protocolos TTL (Wiegand & ISO2):
- ISO2 (Clock & Data) Decimal (7 octetos mx.).
- Wiegand 26 bits
- Wiegand con LRC Hexadecimal (12 octetos mx.) + LRC.
- Wiegand sin LRC Hexadecimal (12 octetos mx.). Protocolos serie (RS232 & RS485): Se puede configurar la estructura de la trama con los siguientes parmetros opcionales (en gris). 1 octeto STX 0x02 1 octeto + X octetos 1 octeto 1 octeto 1 octeto 1 octeto Nmero de Va + Tag Data*
0x0y nn..nn LRC CR 0x0D LF 0x0A ETX 0x03
- STX+ETX: agregacin de un 0x02 (STX) y 0x03 (ETX) al comienzo y final de la trama
- CR/LF: regreso carro (0x0D + 0x0A) configurable por separado
- LRC: octeto de control (XOR de todos los octetos anteriores salvo STX)
- Datos transmitidos en decimal o hexadecimal
- ASCII: si esta opcin est activada, los datos incluidos en la trama estarn en formato ASCII (el tamao de los datos del tag ledo estar entonces duplicado).
- Ceros no significativos: completa los datos del tag con 0 no significativos, para obtener el tamao de datos definido.
(Va n + Cero de relleno + Datos del tag...). Al conectar a la alimentacin: la LED del lector roja se enciende. Inicializacin del lector. Despus de la inicializacin, el lector busca un tag de configuracin durante 15s en la antena 1 (conectada al puerto RF 1). Secuencia de arranque - SMA / SLA Si no detecta ningn tag: parpadeo de la LED antena "color RFON" (200 ms) (por defecto azul) / RFOFF (200ms). Si deteccin de cualquier tag: la LED antena encadena la secuencia "color RFON" (por defecto azul) / "color DETECCIN" (por defecto naranja) durante 200ms y despus LED OFF. Si deteccin de un tag de configuracin: la LED antena encadena la secuencia "color RFON" (por defecto azul) / "color DETECCIN" (por defecto naranja) durante 200ms y despus LED OFF luego la LED antena proporciona las siguientes indicaciones:
-
-
-
-
3 parpadeos de color VERDE (500ms ON; 200ms OFF): tag de configuracin aceptado OK. 3 parpadeos de color ROJO (500ms ON; 200ms OFF): la regulacin (regin) del tag de configuracin no corresponde a la regulacin del lector. 3 parpadeos de color LILA (500ms ON; 200ms OFF): la clave del tag de configuracin no corresponde a la clave del lector. 5 parpadeos de color ROJO (500ms ON; 200ms OFF): el modelo del lector del tag de configuracin no corresponde al modelo del lector. El final de la secuencia de arranque est indicado por el parpadeo de las LEDs del lector (rojo y verde) 3 veces (500ms ON; 500ms OFF). STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 12 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Dimensiones (mm/in) - SMA Fijacin - SMA Dos tipos de fijaciones posibles:
Kit de fijacin mural orientable
(consultar el Manual de instalacin del KFX-UHF-08) Muro Kit de fijacin mstil orientable
(consultar el Manual de instalacin del KFX-UHF-09) Mstil 1- Fijacin con soporte de fijacin de tipo VESA estndar 75 x 75 mm / 0.79 x 0.79 in (tornillo M4x12 Acero inox. suministrados en el kit de fijacin) O Fijacin directamente en un muro Tornillo 4x35 acero inoxidable recomendado. Es obligatorio conectar una antena al puerto RF 1 (lo ms cercano de las LED). Conexin antenas - SMA Puerto RF 1 4 longitudes de cables serializables estn disponibles:
1.5 m /4.92 ft: CAB-SPECTRE-1.5M 3 m / 9.84 ft: CAB-SPECTRE-3M 9 m / 29.53 ft: CAB-SPECTRE-9M 12 m / 39.37 ft: CAB-SPECTRE-12M Las nicas combinaciones posibles son:
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 13 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES
-
-
-
Fijacin de una antena en el mdulo - SLA Fijar la antena en el mdulo SMA con los 4 tornillos (TCL ALU M4x12) suministrados con el mdulo. Retirar la tapa del puerto RF 1. Conectar la antena al puerto RF 1 del mdulo. Fijacin con soporte de fijacin de tipo VESA estndar 75 x 75 mm / 0.79 x 0.79 in (tornillo M4x12 Acero inox. suministrados en el kit de fijacin) Dimensiones (mm/in) - SLA Es obligatorio conectar una antena al Puerto RF 1 Fijacin - SLA Dos tipos de fijaciones posibles:
Kit de fijacin mural orientable
(consultar el Manual de instalacin del KFX-UHF-08) Kit de fijacin mstil orientable
(consultar el Manual de instalacin del KFX-UHF-09) Mstil Muro Conexin antena/s - SLA Cables antenas SMA / SLA Los cables de antena tienen 1 conector macho y un conector hembra. Etiqueta Hacia la antena 4 longitudes de cables serializables estn disponibles:
1.5 m /4.92 ft: CAB-SPECTRE-1.5M 3 m / 9.84 ft: CAB-SPECTRE-3M 9 m / 29.53 ft: CAB-SPECTRE-9M 12 m / 39.37 ft: CAB-SPECTRE-12M Las nicas combinaciones posibles son:
CAB-SPECTRE-1.5M + CAB-SPECTRE-1.5M CAB-SPECTRE-1.5M + CAB-SPECTRE-3M CAB-SPECTRE-1.5M + CAB-SPECTRE-9M CAB-SPECTRE-3M + CAB-SPECTRE-3M Hacia el mdulo STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 14 sur 15 - Ed. 25/02/2019 SPECTRE Access UHF Read only Installation procedure UHF SPECTRE Access Lecture seule Notice dinstallation UHF SPECTRE Access Solo lectura Manual de instalacin US FR ES Banda de frecuencias Ahorro de antena Polarizacin Ratio Axial ngulo de apertura (-3 dB) Impedancia Cable Proteccin Especificaciones antenas - ANT-UHF-V2 ANT-UHF2-A para SMA/SLA-R4x 865 - 868 MHz 8.30 dBi Circular 0.66 70 50 ohms TNC RP macho Nivel IP66 ANT-UHF2-B para SMA/SLA-R5x 902 - 928 MHz 9.38 dBi Circular 1.16 60 50 ohms TNC RP macho Nivel IP66 348.7 / 13.73 9 9 0 1
.
/
. 2 9 7 2 Fijacin con un soporte de fijacin de tipo VESA estndar 75 x 75 mm / 0.79 x 0.79 in (tornillos M4x12 Acero inox. suministrados en el kit de fijacin) 45.1 / 1.78 in Fijacin de antenas Dos tipos de fijaciones posibles:
Kit de fijacin mural orientable
(consultar el Manual de instalacin del KFX-UHF-08) Muro Kit de fijacin mstil orientable
(consultar el Manual de instalacin del KFX-UHF-09) Mstil Mediciones en Acimut Polarizacin horizontal F = 867 MHz Polarizacin horizontal F = 915 MHz Polarizacin vertical F = 867 MHz Polarizacin vertical F = 915 MHz Declaracin de conformidad STid declara que los lectores SMA-R5x/R4x-A cumplen las exigencias esenciales de la Directiva RED 2014/53/UE y RoHs 2011/65/UE y la Directiva delegada 2015/863/UE. Una copia de nuestra declaracin est disponible enviando una solicitud a qualite@stid.com. Este aparato cumple la Parte-15 de la FCC y los CNR de Innovacin, Ciencias y Desarrollo Econmico de Canad, aplicables a los aparatos de radio exonerados de licencia. Su funcionamiento est sujeto a las dos condiciones siguientes:
1) Este aparato no debe provocar interferencias nocivas. 2) Este aparato debe aceptar cualquier interferencia recibida, incluido las interferencias que pueden provocar un funcionamiento no deseado. Nota: El fabricante no es responsable de las interferencias de radio o TV provocadas por modificaciones no autorizadas del equipo. Modificaciones de este tipo podran anular el derecho del usuario a usar el equipo. Este equipo ha sido probado y se ha declarado que cumple los lmites impuestos a los perifricos digitales de clase B estipulados en el captulo 15 del Reglamento FCC. Estos lmites han sido establecidos para proporcionar una proteccin razonable contra las interferencias nocivas, cuando el equipo se utiliza en un entorno residencial. Este equipo genera, utiliza y puede emitir frecuencias de radio y, si no se instala y utiliza de acuerdo con las instrucciones, puede crear interferencias nocivas que perturben las comunicaciones de radio. Sin embargo, nada puede garantizar la ausencia total de interferencias, en una instalacin determinada. Si el equipo altera la recepcin de radios o de televisiones, lo que se puede comprobar apagando y volviendo a encender el equipo, el usuario debe intentar hacer que desaparezcan estas interferencias recurriendo a una de las medidas siguientes:
-
-
-
reorientar o desplazar la antena de recepcin;
aumentar la distancia entre el equipo y el receptor;
conectar el equipo a un enchufe situado en un circuito diferente de aquel al que est conectado el receptor;
Consultar el revendedor o un tcnico experimentado para obtener ayuda. Este equipo cumple los lmites de exposicin a las radiaciones de la FCC establecidos, para un entorno no controlado, en las siguientes condiciones:
-
-
Debe ser instalado y utilizado a una distancia mnima de 25 cm / 9.84 in, entre la fuente de radiacin y su cuerpo. El transmisor no debe estar colocado al lado, o no debe funcionar con otra antena u otro transmisor. Suscriptor de DEEE Pro (Residuos de Equipos Elctricos o Electrnicos Profesionales) En respuesta a la reglamentacin, STid finanza el sector del reciclaje de Rcylum dedicado a los DEEE Pro (Residuos de Equipos Elctricos o Electrnicos Profesionales) que recupera de forma gratuita los materiales elctricos de iluminacin, los equipos de control y de vigilancia, y los dispositivos mdicos usados. Para ms informacin consultar www.recylum.com STid - 20 PA des Pradeaux FR13850 Grasque - NI1127X03 - Page 15 sur 15 - Ed. 25/02/2019
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-01 | 902.75 ~ 927.25 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-03-01
|
||||
1 | Applicant's complete, legal business name |
STid
|
||||
1 | FCC Registration Number (FRN) |
0021921689
|
||||
1 | Physical Address |
20 PA des Pradeaux
|
||||
1 |
GREASQUE, N/A
|
|||||
1 |
France
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
OVN
|
||||
1 | Equipment Product Code |
SMA
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
P******** S****
|
||||
1 | Title |
Technical Director
|
||||
1 | Telephone Number |
+33 4********
|
||||
1 | Fax Number |
+33 4********
|
||||
1 |
s******@stid.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. Device operates with specific antennas in configurations as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 23 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
EMITECH Montpellier
|
||||
1 | Name |
O******** H****
|
||||
1 | Telephone Number |
33-4-********
|
||||
1 | Fax Number |
33-4-********
|
||||
1 |
o******@emitech.fr
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.75000000 | 927.25000000 | 0.4380000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC