all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
15 SK-2612-SPQ UserMan-US r1 | Users Manual | 5.35 MiB | December 23 2019 | |||
1 |
|
09 SK-2612-SPQ IntPho | Internal Photos | 947.97 KiB | December 23 2019 | |||
1 |
|
08 SK-2612-SPQ ExtPho | External Photos | 562.33 KiB | December 23 2019 | |||
1 |
|
06 SK-2612-SPQ LabelSmpl-US | ID Label/Location Info | 83.88 KiB | December 23 2019 | |||
1 |
|
10 SK-2612-SPQ TSup r1 | Test Setup Photos | 163.04 KiB | December 23 2019 | |||
1 | 11 SK-2612-SPQ OpDes r2 | Operational Description | December 23 2019 | confidential | ||||
1 | SK-2612-SPQ BlkDia | Block Diagram | December 23 2019 | confidential | ||||
1 | 13 SK-2612-SPQ Schem r1 | Schematics | December 23 2019 | confidential | ||||
1 |
|
14 SK-2612-SPQ TestRpt DXX r1 | Test Report | 2.34 MiB | December 23 2019 | |||
1 |
|
17 SK-2612-SPQ AntSpec | Operational Description | 12.75 KiB | December 23 2019 | |||
1 |
|
18 SK-2612-SPQ RFExp | RF Exposure Info | 185.99 KiB | December 23 2019 |
1 | 15 SK-2612-SPQ UserMan-US r1 | Users Manual | 5.35 MiB | December 23 2019 |
ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Resetting to Factory Default and Programming Add/Delete Cards:
The keypad must be connected to a Request-to-Exit (RTE) button to be reset to factory default settings. When resetting to factory default, user information is retained. You may also program new Master Add and Master Delete Card if they are lost. To reset the keypad to factory default settings, follow steps 1~4 below. To also program new Master Add and Master Delete cards, follow steps 1~3 and 5 below. NOTE: Programming new Master Add and Master Delete cards will delete the previous Master Add and Master Delete cards. 1. Power off the keypad 2. Hold down the egress button and power the keypad on, continuing to hold down the egress button for approximately 10 seconds until you hear 2 beeps and the LED tums orange. 3. Release the egress button. 4. Ifyou only need to reset the keypad to factory default, wait until the LED changes to red (about 30 seconds) indicating that the reset has completed successfully. 5. Ifyou need to program new Master Add and Master Delete Cards, within 30 seconds, read two cards. The first will become the Master Add Card, and the second the Master Delete Card. The LED will change to red indicating that the reset has completed successfully. FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that maycause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible forcompliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates uses and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur ina particular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receivingan = tenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different fram that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body, SECO-LARM U.S.A., Inc. 16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Phone: (949) 261-2999 | (800) 662-0800 Email: sales@secolarm.com 20 SECO-LARM U.S.A., Inc. aff PICSNA MI_SH-2612-5PQ_ 191000 docs ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Quick Installation Guide:
This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming instructions, see "Table of Contents on pg. 4. Mounting Diagram:
a | 4 Z| Lj; Choice of 2 pairs of ag GZ mounting holes a) ZZ Drill at least a/e"
(@9mm) wiring hole a Yj Uy Yt Housing base
& GY EO Me:
Security screw >y Quick Wiring Diagram:
Red - 12VDC (+) (+) Purple - Output (COM) Gray Tamper Alarm Output (GND) Black - Ground (-) (-) Coy Egress Yellow - Egress Input (N.0.) YF] stem | 12V0C
-] Power Supply Brown - Door Sensor Input*
Blue - Output (N.O.) Ts Orange - Output (N.C) O%.-*"P"7) Lack ESIC CS) jsssees |
NO. Quiput for Faill-secure Lock N.C. Output for Fail-safe Lock Cathode <T Green - Data 0 |
Wiegand Diode IN4007 Controller (See note below) NOTE: For DC-powered electric strikes, connect the included diode as close as possible and in parallel with the electric strike, This absorbs possible electromagnelic interference to prevent operation of the strike from damaging the keypad. Do not connect a diode when using electromagnetic locks or with AC powered strikes. 2 SECO-LARM U.S.A., Inc.
*Connect fo ground if unused ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Duplicating Users to Other Keypads:
User data can be duplicated from one keypad to Fig. 1 other keypads (up to 10 at one time) that supports = - tar Sup oy SS this function, All user data will be transferred to the ag me) 14 aq @
second unit (taking about 3 minutes for 1,000 Bim re . __ (a) users), overwriting any existing user data, em |S m elo Connect the keypads in parallel as shown in Fig. 1, 7 Green (DO) |g a a all wires to the same corresponding color. (3) (&) | White (D1) ) =) Make sure that both keypads have the same = |} Tosddional |_|
master programming code. To transfer user data, units use the following general formula from within base programming mode on the main keypad containing the user data (see "Enter and Exit Base Programming Mode, pg. 7):
2J8) (+) Initiate User Data Transfer function code (LED will change to steady orange) NOTES:
* All keypads must support the data transfer function and have the same master programming code.
* Any user data existing on the additional devices will be overwritten. When transfer is complete, a short beep will sound, the LED will flash green once and change to red.
* Exit programming mode by pressing the _-] key after transfer is complete. Wiegand Controller Mode:
The keypad can work as a controller connected to an external Wiegand reader, Wiegand Controller Mode Wiring Diagram:
Red - 12VDC (+) (+) Purple Output (COM) (+) Alarm 42V0C Gray - Tamper Alarm Output (GND) | !-) Power Black - Ground (-) L _ (-) wey W@ _ Egress aw Yellow Egress Input (N.O.) Button
(5) (6) Brown Door Sensor Input 5) Blue - Output (N.O.)
(+) () Orange - Output (N.C) 1-7-4 Wiegand
(nro Output Relay Reawer
\ NO. Ouiput for Fail-secure Lock @ GND N.C. Output for Failsale Lock Gata @ HN Green - Data 0 @ DD White - Data 1 eo NOTE: For DC-powered electric strikes, connect the included diode as close as possible and in parallel with the electric strike. This absorbs possible electromagnetic interference to prevent operation of the strike from damaging the reader/keypad. Do nat connect a diode when using electromagnetic locks or with AC powered strikes. 18 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Table of Contents:
QUICK Installation Guides .......ceeerecrersceseeseeseseesed Programming User Codes: cscs | P12 Mouriting Diagram... 2 Changing the User Code for an Existing User: .......... 12 Quick Wiring Diagram: .......0c0c00 sine Programming Duress Codes or Cards: ..........ccccssee Id Quick Programming Guide:........... weed DepBHING USOPS2 eects neesscnsnssesseeenscnaes 13-14 Table fareee we Programming Quiput Mode and Times... M1 i 4 Programming Notification Sounds, LED, Backlight:... 15 Overviews... | Programming the External Alarm Qutpuit:........... 18-16 Parts List: 4 Programming the Wrong-Code Lockout/Alarmy......... 16 LED Indicators and Device Sounds: .. 5 = Setting up a Two-Door Interlock System... TF Important MOBS: ........ercrcsesessrssesees veoh Duplicating Users to Other Keypads: .......scscsscssseres 1G PStAMIABION: ...cccsecsosssossesscscssevecesens wed Wiegand Controller Mode... BT Wiring Chaitt:.......ccc0e: 6 Wiegand Reader Mode: va 6-F Troubleshooting:............... 19 Programming Format and Default Vales: f Reseiting to Factory Default a Programming the Master Programming Code: ...........8 AdidiDelete Cards: .......ossossesesescesserserssevsesersnseseee dll Setting the Keypad Operation MO: cc =| Accessories Available from SECOMLARM:.....csuu02l Programming the Access Mode / Security Level:....8-9 Important Notes/WamingS............1::scsssssssssssesereseerdlll Programming User Proximity Cards... TT WARTEIIY. ccccsuscsuscsaescreetserestsastumsesansonesceeseen ell Specifications:
Operating voltage 9-18 VDC standby 40mA@12VDC Current draw active 105mA@12VDC (max) Form C 2A@12V0C Outputs Alarm 2.0A@12V0C Wiegand 26~37 bits, PIN output bits - 4, 8, or 10 Egress input N.O. Ground Door sensor input N.C. Ground Wiegand input 26~37 bits, PIN input bits - 4, 8, or 10 Card type EM 125kHz Enclosure material Black ABS plastic Operating temperature ~40~140 F (-40-60 C) Operating humidity 10-90% non-condensing Dimensions The ea Sig (49x17 20x24 mm) Weight 5.602 (1659) Overview: Parts List:
1x Keypad 1x Security wrench 1x Diode 2x Mounting screws 2x Plastic screw anchors 1x Master add card*
1x Master delete card"
1x Manual User proximity cards or key fobs sold separately (see pg. 20) 4 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming the Wrong-Code Lockout/Alarm:
The device can be programmed to either lockout or sound an internal alarm after 10 successive wrong cards/codes. The lockout continues and the LED flashes red for 10 minutes and cannot be reset before then. The built-in notifications and external alarm sounds for the length of time set in the alarm settings
(1~3 minutes, see notes below), or until stopped with a valid master programming code or user code. When programming the wrong code lockout, use the following general formula from within base programming mode (see "Enter and Exit Base Programming Mode," po. 7):
soa 4
-) Program Wrong-Code Lockout/Alarm function code (LED will change to steady orange) 4] -Disable or Enable/Configure the Wrang-Code Lockout/Alarm Disable or Enable/Configure Wrong-Code Lockout/Alarm:
* _0] Disable wrong-code lockout (factory default) _1)- Enable wrong-code lockout to deny access for 10 minutes
* _2]-Enable wrong-code alarm to sound the keypad notifications / external alarm NOTES:
* If wrong-code lockout is enabled, the LED will flash red and all access will be denied for 10 minutes after 10 successive wrong cards/oodes.
* If wrong-code alarm is enabled, the LED will flash red and the built-in notifications (if enabled, see Programming the Notification Sounds, LED, and Backlight," pg. 15) and external alarm (if enabled, see "Programming the External Alarm Output, pgs. 15~16) will sound and continue for the length of time programmed for the alarm or until a valid master programming code or user code is entered. This setting requires either or both the built-in notifications and external alarm output to be enabled and the alarm timing is set by the external alarm settings.
* The *] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-] key (see "Enter and Exit Base Programming Mode, pg. 7). Examples:
1. Disable the wrong-code lockout:
Ja 4 2. Enable the wrong-code lockout to deny access for 10 minutes:
2) sy ls) 3. Enable the wrong-code alarm for the set time (disabled with a valid master code or user code/card):
ie] 2) GJ 16 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Wiring Chart:
Color Function Description Red Power (+) Connect to +12VDC power supply Black Ground (-) Connect to Ground Yellow Egress Input__| N.O. Pushbutton contact to ground. Press button to activate the output Brown Door Sensor | Connect toa magnetic contact or door sensor Blue Output N.O. Purple OutputCOM | NO/NC/COM, relay output, max. 3A@12VDC Orange | Output N.C. Gray Alarm Qutput | Transistor ground output, max. 2.54@12VDC. Green Data 0 Wiegand controller White Data 1 Wiegand controller See also Quick Wiring Diagram on pg. 2 for a sample application and for the use of the included diode. Getting Ready to Program:
The keypad is activated by keypad user codes (4~6 digits) and/or user proximity cards." All user codes/cards must have a unique User ID (between 0 and 997 for users and 998 or 999 for duress). Itis important to record all User IDs for future management tasks. Card types:
There are four types of cards:
* Master add card' - Used only to quickly add user cards without entering programming mode. This will assign each user card to the first available user ID in consecutive order,
* Master delete card - Used only to quickly delete user cards without entering programming mode.
* User cards Up to 998 user cards (user IDs 0~997) can be assigned to activate the relay.
* Duress cards - Up to 2 duress cards (user ID s 998~999) can be assigned. Duress cards are used under duress to activate the relay while triggering an alarm. Keypad code types:
There are three types of keypad user codes:
* Master programming code (6 digits) - Used only to enter programming mode and cancel alarms. There can be only one master programming code per keypad.
* User codes (4~6 digits) - Up to 998 user codes (user IDs 0~997) can be assigned. User codes are used to activate the relay and cancel alarms.
* Duress codes (4~6 digits) up to 2 duress codes (user ID s 998~999) can be assigned. Duress codes are used under duress to activate the relay while triggering an alarm. Security Levels:
There are four possible security levels (see "Programming the Access Mode / Security Level, pgs. 8~9 for more detail):
* Card only
* Card or code (default)
* Card+code
* Multiple cards/user codes In this manual card refers to either proximity cards or fobs. tithe master add/delete cards are lost, see "Resetting to Factory Default and Programing Add/Delete Cards," pg. 20) 6 SECO-LARM U.5.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Deleting Users (Continued):
Examples:
1. Delete User ID #501:
3 shld 4 2. Delete user code #6905:
2) (efsfols) iy 3. Delete a user card #56789012:
2) slelzJaseyejsj2) J 4. Delete a user card by presenting the card:
2) ReadCard _*]
5. Delete all users (if the master programming code is 631732):
2) elazave) Programming the Output Mode and Time:
The relay can be programmed to toggle the relay ON/OFF (toggle mode), or to trigger for a programmed length of time up to 99 seconds before automatically turning OFF. The output can be used for locking or unlocking a door or for a variety of functions that can be controlled with the keypad. When programming the output mode and time, use the following general formula from within base programming mode (see "Enter and Exit Base Programming Mode, pg. 7):
JAA os 3) Program Output Mode and Time function code (a short beep will sound and the LED will change to steady orange) Aj Output Mode and Output Time Output Mode and Output Time:
e (oJ -Start/stop (toggle) mode. In this case, the output starts when a user code is entered, and stops when a user code is entered again.
* (1) to 2)3)- The output triggered by a user code lasts up to 99 seconds before automatically turning off (1=500ms, default: 5 seconds). NOTES:
* For programming the output timing, 1=500ms. 2~99 represents full seconds.
* The _*] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-| key (see "Enter and Exit Base Programming Mode," pq. 7). Examples:
1. Set the output to toggle mode:
Jog aw 2. Set the output to 60 seconds:
2) sie) 4) 14 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming the Master Programming Code:
The master programming code is used to enter base programming mode and fo cancel alarms. The master programming code does not serve as a user code to activate the keypad output. 1. Enter base programming mode (see "Enter and Exit Base Programming Mode," pg. 7). 2. Enter the new master programming code (6 digits):
oO) sds ode) i) de) x) 12] (where "X" is the new master programming code) 3. Exit programming mode: Press the _-] key or wait 25 seconds to exit automatically. Setting the Keypad Operation Mode:
The keypad can operate as a standalone keypad, a controller connected to an extemal Wiegand reader, or a Wiegand reader. To set the operating mode, use the following general formula from within base programming mode (see Enter and Exit Base Programming Mode," pg. 7):
2] 4) J 2) Operating Mode function code (a short beep will sound and the LED will change to orange}
4) - Set the operating mode Operating Mode:
* (2) Standalone or controller mode (default) _3]Wiegand reader mode NOTE: The _*] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the +] key (see "Enter and Exit Base Programming Mode," pg. 7). Programming the Access Mode / Security Level:
Itis important to program the access mode / security level before adding users as this will affect user selup. In all modes except the "card+code" security level, a user ID may be assigned a card* ora user code, but not both. To give the same person both a card and a code requires two user IDs. Due to the exceptional operation of the "card+code" security level, see the notes for this security level below. The keypad can be programmed to one of four access modes / security levels:
* Card only -a user must use a card for access
* Either card or code - a user may use either a card or a user code for access (default)
* Card+code a user must use both a card and user code for access NOTES:
* In this security level, the card should be assigned first. The keypad will automatically assign each entered card a temporary user code 8888. This code will not activate the lock and must be changed before use.
* (lf you change to this security level after adding users, all existing card users will be given the temporary user code BBB which then must be changed for each user.
* |f you change to this security level after adding users, all existing code users have to be reprogrammed by adding a card, which will assign them the temporary user code 8888.
* The 8888 code for each card must be changed using the steps listed under "Changing the User Code for an Existing User, pg. 12, and not using the regular steps for adding a user code. 8 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming User Codes (Continued):
* Additional users may be entered in succession without repeating the function code _1J.
* The _*) key returns you to base programming mode (the LED will flash red), Exit programming mode by pressing the _-] key (see "Enter and Exit Base Programming Mode," pg. 7). Examples:
1. Program user code _2)_2)_7)_5J for User ID #0:
Jods gas 3 2. Program a user code _*|_2)_7)/J_5] allowing the device to auto-assign to the first available User ID
(not recommended unless you have a complete record of already assigned User IDs):
a) (sjsfryels) sy}
3. Program two user codes - 67890 for User ID #201, and 654321 for User ID #17:
J (zyols) s) shzssssse) s)waitforbeep, then Jz) 2) isJs)sJaj2ja) J NOTE: The add user function code _1J places you into this programming mode. Press the add user function code only before adding the first user. To continue to add other users in the same session, do not repeat the add user function code _+]. Changing the User Code for an Existing User For a Code User:
You can change the user code for an existing user without going into programming mode if you know both the current user code and user ID, Users can also use this method to change their own user codes to something they can more easily remember, This procedure is done outside programming mode. Use the following formula in standby mode to change an existing user code.
=) Y) 4) shelelc) ) Byeysyn) 2) Np NyNpn) 2) uj - User ID c| Current user code 4 New user code (4~6 digits, entered twice, do not use the user code 8888) In Code+Card" Security Level:
If you have set the security level to "card+code," you must use this method to change the temporary 8888 user code that the device automatically assigns to card users. Use the following formula in standby mode to change a user code.
=] ReadCard #) clelcle) 2) sIsyNIN) 2] NINININI is
-c| Current user code (temporary default 8888) 4] New user code (4~6 digits, entered twice) Programming Duress Codes and Cards:
Duress codes/cards are assigned to user IDs 998 and 999 to trigger an alarm while unlocking the door, Duress codes/cards are programmed in the same manner as regular users, except that you must particularly assign them to user ID 998 or 999. (see "Programming User Proximity Cards, pgs. 9~11 and Programming User Codes," pgs. 11-12):
12 SECO-LARM U.S.A., Inc. ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming User Proximity Cards (Continued):
individually by Reading Cards:
J (A) 14) Read Card _s)-After.a short beep, you may continue to add cards by repeating these steps, but without repeating the function code 1). 1) - Add Users function code (a short beep will sound and the LED will change to steady orange) 4J - 2) to (2J-2Jz) - 998 unique User IDs to trigger the device (if 4) _#J is omitted, the device will assign the user card to the first available User ID.) Individually by Gard Numbers (If Using Cards with Printed Numbers}:
3) @2lsje)s)2/2)s) (+) -Aftera short beep, you may continue to add cards by repeating these steps, but without repeating the function code J. 1] - Add Users function code (a short beep will sound and the LED will change to steady orange}
8) - 8~10 card number (the device will assign the user code to the first available User ID) Adding Cards in a Large Batch (If Using Cards with Printed Numbers):
This method allows the addition of up to 998 cards in a single batch. This is especially useful in the initial setup. This process adds the cards in consecutive order, assigned to available user IDs consecutively. J 4 4) &) &) eleveseleclc) -)-The process will take up to 2 minutes 1] Add Users function code (a short beep will sound and the LED will change to steady orange)
-AJ - 2) to _9)9)_7) - the beginning user ID 8] -the number of cards/fobs to be added
] =the card number (8~10 digits) for the first card (or read the first card in the sequence) NOTES:
* Note that in the step _) above, you may add the first card number, or you can read the first card.
* The user IDs will be assigned in consecutive order beginning from the beginning user ID.
* The card numbers must be in consecutive order with no gaps in the numbering sequence and must start with the lowest number. With the Master Add Card:
The Master Add Card allows you to enter cards quickly without entering programming mode. It takes you directly into the "add user" function mode without needing to enter the master programming code and the _1) add user function code. Once in this mode, you made add cards using any of the methods described above, but omitting the _1J. When complete, present the Master Add Card again to retum to standby mode, NOTES:
* [tis important to record each user ID assigned in order to simplify future user management.
* Auser |D can only have a single card or single code assigned (except by using the method described in Changing the User Code for an Existing User," on pg. 12 when in the card+code security level), If you try to add a card to an existing user ID that already has a user code assigned, the user code will be removed. 10 SECO-LARM U.S.A., Inc. ENFORCER SK-2612-SPQ Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Manual Features:
* 1,000 Users (up to 998 users and 2 duress users) * EEPROM Memory protects programmed
* User code length 4~6 digits information in case of power loss
* 9-18 VDC Operation All features programmed directly on the keypad:
* Low current draw - 105mA max, No need for an extemal programmer
* Form C relay output - 2A@12VDC * Egress input lets users exit the premises
* Adjustable output time - 0.5~99s, or toggle without keying in a code
* Built-in tamper alarm and external alarm output + * Can serve as Wiegand reader or controller,
* Backlit keypad and multicolor status LED output and input - 26~37 bits EM 125kHz * 2-Door interlock
* Outdoor rated - IP66 * Extreme cold tolerance to -40 F (-40 C)
* Easy transfer of users to additional devices * Sturdy black ABS plastic housing SECO-LARM Ss CE@
ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Wiegand Controller Mode (Continued):
Set Wiegand Input Bits/PIN Input Format:
Set the Wiegand input bits and format according to the output format of the external reader. To set the Wiegand input bits and the Wiegand PIN output format, use the following general formula from within base programming mode (see Enter and Exit Base Programming Mode, pg. 7):
4) alal is) 3) - Set Wiegand Input Bits/PIN Input Format function code (a short beep will sound and the LED will change to steady orange) 4) - Wiegand Input Bits/PIN Input Format Wiegand Input Bits/PIN Input Format:
* 2) 6) to _3)7] - Set Wiegand input bits (26~37, factory default, 26)
* 4], (8), or 1.2] - Set Wiegand PIN input format (4, 8, or 10, factory default, 4) NOTES:
* Basic programming is the same as in the stand-alone mode.
* [fthe external device is an EM card reader, users can be addedideleted on either device. If the external device is an HID or Mifare reader, users can only be added/deleted on the external reader.
* The _*) key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-J key (see Enter and Exit Base Programming Mode," pg. 7}. Wiegand Reader Mode:
The keypad can work as a standard Wiegand reader, Wiegand Reader Mode Wiring connected to an external controller. Be sure to set the _Keypad Red keypad operation mode to Wiegand reader mode (see o a Black porta
"Setting the Keypad Operation Mode," pg. 8). a) a @ GND Connect the keypad to the controller as shown in the aR wae Te wiring diagram on the right. (3) (0) e D1 NOTES: = 7 - LED
* The reader will override most controller settings. @ Buzzer
* The brown wire will control the LED. When its voltage is low, the LED will become green.
* The yellow wire will control the internal buzzer. When its voltage is low, the buzzer will sound. Set Wiegand Output Bits/Format:
Set the Wiegand output bits/format according to the input format of the controller. To set, use the same formula as used for setting the Wiegand input bits!format (See, Set Wiegand Input Bits/Format," above). Troubleshooting:
Ensure the User ID assigned is between 0 and 997 for users and Unit fails to accept anew useriduress either 998 or 999 for duress codes/cards code/card * Ensure the user code is between 4~6 digits long and not already assigned to another user Unit fails to respond to a programmed Ensure the unitis in standby mode by pressing the -) key until the user code/card LED becomes steady red SECO-LARM U.S.A., Inc. 19 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Quick Programming Guide:
Programming Tips:
* Master programming code (6 digits) should be programmed before any other programming.
* A steady red LED indicates that keypad is powered on and ready, The LED will change to orange and a single beep will sound to indicate the device has entered programming mode. Programming Instructions:
Follow the instructions below if the following covers your needs:
* Anew master programming code.
* Setting one user code.
* Setting one user card
* A door-unlocked time of 4 seconds after the output is activated.
* Access mode / security level set to "card or code" (default) NOTE: It's important to choose and fully understand the security level before adding users. For other security levels besides the default, read their setup instructions carefully before proceeding. 1. Enter base programming mode:
J dass 2 NOTE: _1)2]_3)4)_5]_8] is the factory default master programming code. A new master programming code (6 digits) should be set the first time you enter programming mode. 2. Sel the master programming code (6 digits):
0) Expxpxog og ep ofocofoo) Se]
NOTE: _*J_)_xJ_x)*J/*] is the new master programming code and must be entered twice. 3. Seta user card to operate the output (unlock the door):
a) sls) +) ReadCard 4]
NOTES:
(ifs) (*) chooses user ID #15 of 998 possible user IDs (0~997).
* To add other users (card or code) do not repeat the initial function code _1J. 4. Seta user code to operate the output (unlock the door):
Jae) 4 assez) 4 NOTES:
e 1)0) _*] chooses user ID #10 of 998 possible user IDs (0~997).
* (4J'5}/3)/7J is the new user code for user ID #10 (4~6 digits). Do not assign the user code 8888 to any user ID.
* To add other users (card or code) do not repeat the initial function code 1]. 5. Set the output time (skip this step if the default value of 5 seconds is acceptable):
Js 4 NOTE: _4J sets the output delay time for 4 seconds. 6. Exit programming mode:
=) One short beep will sound to indicated that the keypad has exited programming mode. SECO-LARM U.5.A., Inc. 3 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Setting up a Two-Door Interlock System with Two Keypads:
In this application, two keypads are each connected to separate door locks and egress pushbuttons. While one door is open, the other cannot be opened. Two-Door Interlock Wiring Diagram:
12VDC Door 1 Power Supply Door 2
= (+) L LC) Red(+) Mme Alarm | Purple (COM) (1) (2)
(3) (4) (3) @)
(5) (6) (5) &) 7) (7)
(0) {o) Le) (o) C) (#) amo (oven) Output Relay Output Relay
* BLO. Output for * 8.0, Gutput for Fail-secure Lock Fail-secure Lock
* ALC. Outpul for * LC. Quiput for Fail-sale Lock : Fail-sale Look Diode IN4007
(see note | Wiegand below) [Controller White - Data 1 NOTE: For 0C-powered electric strikes, connect the included diode as close as possible and in parallel with the electric strike. This absorbs possible electromagnetic interference to prevent operation of the strike from damaging the keypad. Do not connect a diode when using electromagnetic locks or with AC powered strikes. Programming the Interlock System:
When programming the interlock system, use the following general formula from within base programming mode (see "Enter and Exit Base Programming Mode," pg. 9):
JIA a 4) - Program the Interlock System function code (LED will change to steady orange) 4] - Disable or Enable the Interlock System Disable or Enable the Interlock:
* 0) Disable the interlock (factory default)
* (1) - Enable the interlock NOTE: The _#] key retums you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-] key (see "Enter and Exit Base Programming Mode," pg. 7). SECO-LARM U.S.A, Inc. 17 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader LED Indicators and Device Sounds:
Status Sounds LED Power on in standby mode - Red steady In base programming mode 1 Beep Red flashing In function programming mode 1 Beep Orange steady Exit programming mode 1 Beep Red steady Successful operation 1 Beep Green flash once Unsuccessful operation 3 Beeps Built-in alarm Rapid beeping" Red flashing rapidly De-activate the built-in alann by entering a valid user code. Important Notes:
IF USING THE KEYPAD WITH A MECHANICALLY OPERATED DOOR OR GATE, MOUNT THE UNIT AT LEAST 15 (5m) FROM THE DOOR OR GATE TO PREVENT USERS FROM BEING CRUSHED OR PINNED. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH, 1. Always disconnect power before servicing the keypad. Do not apply power until all connection wiring is completed. 2, The keypad must be properly grounded. Use a minimum 224WG wire connected to the common ground wire. Failure to do s0 may damage the unit. 3. All wiring and programming should be done by a professional installer to reduce the risk of improper installation. 4, Be sure to store this manual in a safe place for future reference. Installation:
1. Find a suitable location to mount the keypad. Install at a Fig. 1 ; ;
height convenient to most users. 9: os (eaten) wing hoe 2. Using the included security wrench, remove the security screw located on the bottom of the keypad (Fig. 1}. 3. Carefully remove the keypad from the housing base, sliding the keypad slightly upwards. 4. Using the housing base as a template, mark the holes needed for the wiring and mounting screws and drill needed holes (choose either of the two pairs of mounting holes). Ensure that the wiring hole is large enough to allow the wiring to be pushed in without crimping. 5. Run wiring through the wall to the wiring hole in the wall 6. Thread the keypad wires through the center of the keypad NOTE: For weatherproof installation, add a base and connect all according to Wiring Chart" on pg. 6. peed of sticane sealant around ae 7. Carefully push the wires through the hole in the wall, 8. Install the base using the included mounting screws and mounting screw anchors (if necessary). Ensure the correct orientation as shown in Fig. 1. 9. Finish assembly by reattaching the keypad to the base and securing with the security screw. SECO-LARM U.S.A., Inc. 5 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming Built-In Notification Sounds, LED, and Backlight:
The keypad notification sounds, LED, and backlight may be disabled. Setting the keypad notification sounds affects all sounds from the keypad, including keypad presses, successful card/code entry notifications, duress alarm, and wrong-code alarm. When programming, use the following general formula from within base programming mode (see Enter and Exit Base Programming Mode," pg. 7}:
aa 7) - Program Notification Sounds/LED/Backlight function code (LED will change to steady orange) 4) - Enable/Disable Notification Sounds/LED/Backlight Enable/Disable Notification Sounds/LED/Backlight:
* (0) - Disable notification sounds 1) - Enable notification sounds (default) 4) - Disable LED 5) - Enable LED (default) 6) Disable keypad backlight
* (7) - Enable keypad backlight (default) NOTES:
* Disabling the notification sounds affects only the internal sounds and not the extemal alarm output.
* The duress alarm and wrong-code alarm will trigger both the internal notification beep and the external alarm, depending on their settings.
* The _*] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-| key (see "Enter and Exit Base Programming Mode," pq. 7). Programming the External Alarm Output:
The external alarm sounds an external alarm when the tamper, duress, or wrong-code alarm (if enabled, see "Programming the Wrong-Code Lockout/Alarm," pg. 16) is triggered. To program, use the following formula in base programming mode (see "Enter and Exit Base Programming Mode," pq. 7):
sa wl
'5) = Program Alarm function code (LED will change to steady orange) 4) - Alarm Disable/Enable and Alarm Time Alarm Disable/Enable and Alarm Time:
0] Disable alarm (factory default)
* 1) to 2)-Enable and set the alarm time, 1~3 minutes (factory default, 1 minute) NOTE: The _#] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-] key (see "Enter and Exit Base Programming Mode," pg. 7). Examples:
* Disable the external alarm:
Ja 4
* Enable the extemal alarm and set it to 2 minutes:
Jas SECO-LARM U.S.A., Inc. 15 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Getting Ready to Program (Continued):
Enter and Exit Base Programming Mode:
All programming of the keypad is done from base programming mode. 1, Enter base programming mode using the master programming code:
=) 2d Jad) 4) - (One beep will sound and the LED will flash red) NOTE: J*J_*J JJ] is the master programming code (6 digits). +)_2)2J/+J/5J_] is the defautt
(see Programming the Master Programming Code," pg. 8). 2. Within the base programming mode, press a function code (see Programming Format and Default Values, below) to enter function programming mode (the LED changes to steady orange). The function code is not repeated between programming different items under the same function code. 3. Exit function programming mode: Press the _#] key. 4, Exit base programming mode: Press the _-| key or wait 25 seconds to exit automatically. NOTES:
* DO NOT DISCONNECT THE KEYPAD FROM POWER WHILE IN PROGRAMMING MODE. Disconnecting the unit while in programming mode may cause a memory error,
* The LED will flash green once indicating the unit has entered base programming mode and with a successful programming step. If you are unsure which function programming mode you are in, press the _*] key to retum to base programming mode and press the function code to proceed.
* Except for changing the user code for an existing User ID or using the Master add and Master delete cards, for all programming functions the keypad must first be in base programming mode. Programming Format and Default Values:
In this manual, the format used for programming the keypad is as follows:
* Asingle-digit (x)) FUNCTION CODE to tell the keypad what is being programmed.
* A varying number of digits (_xJ) to represent the parameters of that FUNCTION. The *] key to confirm programming of the FUNCTION and exit to base programming mode. The =] key to exit programming mode and retum to standby mode. The following is a list of the different programming functions:
Function Code" Parameters Default Functions and Values Pg. #
0 Master programing code Default 123456, code length 6 digits 8 1 Add usenduress cards/codes No default, must be programmed 9-13 Z Delete user/duress cardsicodes _| No default, must be programmed 13-14 3 Output mode/time Momentary 5 seconds 14-15 4 Access mode / security level Card or code &~9 5 Set extemal alanmitime 1 minute 15~16 6 Wrong-code lockout/alarm Lockout disabled 16 7 Sounds, LED, backlight All ON 15 Operation mode Stand-alone mode 8
& Set Wiegand output/input formats | Qutput/input bits - 26, PIN output/input bits - 4 19 9 Set interlock mode, Interlock default - OFF i?
Duplicate to another device Duplicate no default, must be programmed 18
*Press the function code only to enter the programming mode for that function. It should not be repeated between each parameter. SECO-LARM U.S.A., Inc. 7 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming Duress Codes and Cards (Continued):
IMPORTANT NOTES:
A duress user ID can only have a single card or single code assigned (except by using the method described in "Changing the User Code of an Existing User," on pg. 12 when in the card+code"
security level). If you try to add a code to an existing duress user ID that already has a card assigned, the card will be removed and vice versa.
* The duress alarm will sound for the number of minutes set for the external alarm (see Programming the External Alarm Output, pgs. 15~16) and cannot be silenced before thal time is up.
* |fauser card or code is used while the duress alarm is sounding, the alarm will continue fo sound and not stop after the programmed alarm output time expires. When this happens, the duress code/card must be used again, after which the timing cycle will start again and the alarm will stop only after that time has expired.
* Incode+card security level, either the duress card or code will trigger the duress alarm. Deleting Users:
Deleting Individual User/Duress Codes or cards:
To delete a user or duress code/card, use the following general formula from within base programming mode (see "Enter and Exit Base Programming Mode, pg. 7):
24 AAA. 4 2] - Delete Users function code (a short beep will sound and the LED will change to steady orange) Either: A)- 2) to 9J2)s) - the user/duress ID (Duress IDs must use this method) Or: Al - (XJ) 2) 2) 2)%) - the user code (4-6 digits) Or: 4] Read card Deleting Cards with the Master Delete Card The Master Delete Card works similar to the Master Add Card, but allows you to delete cards/codes quickly without entering programming mode. The card takes you directly into the "delete user function mode without needing to enter the master programming code and the |2] delete user function code. Once in this mode, you delete cards/codes using any of the methods described above, but omitting the 2|, When complete, present the Master Delete Card again to return to standby mode. Deleting All Users:
To delete all users while retaining the keypad configuration, use the following formula from within base programming mode (see "Enter and Exit Base Programming Mode, pg. 7):
2 WX be) 2) - Delete Users function code (a short beep will sound and the LED will change to steady orange) x)) J) x) x) = Master programming code NOTES:
* Duress IDs cannot be deleted using their user code or card, but must be deleted with the Duress ID.
* Any of the above methods will delete the user ID along with any code/card connected to it.
* The *] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-] key (see "Enter and Exit Base Programming Mode," pg. 7). SECO-LARM U.5.A., Inc. 13 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming the Access Mode / Security Level (Continued):
* Multiple user codes or cards multiple (2~9) user codes or cards are required for access. Any combination of user codes or cards in any order up to the set number must be used with no more than 5 seconds between each code or card. No particular user code or card can be repeated. This is used for extremely secure areas requiring authentication by more than one person. NOTES:
* In multiple user code/card mode, if the same card user code is repeated or a wrong card/code is used, the device will return to standby without triggering the output.
* Inmultiple user code/card mode, the elapsed time between each user code/card must not exceed 5 seconds, otherwise, the device will return to standby. When programming the access mode / security level, use the following general formula from within base programming mode (see Enter and Exit Base Programming Mode, pg. 7):
4) (Alla) 4]
4] Program Access Mode function code (LED will change to steady orange) Al Access Mode Access Mode / Security Level:
* (o}-User card access only _1)-User card+code 2) - Either user card or code (default) 3) 2J/~.3) - Multiple user cards or codes (the second number 2~9 sets the number of cards/codes required for access). NOTE: The _*] key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the _-) key (see "Enter and Exit Base Programming Mode," pg. 7). Examples:
1. Set the access mode to card only:
4) of [J 2. Set the access to require four user codes/cards:
4) 3s) 4 Programming User Proximity Cards:
You should program user cards before programming user codes, especially if you are using the card+code" security level. IMPORTANT NOTES:
* The system assigns a temporary user code 8886 to each card under the "card+code" security level.
* (fata later time, you change the security level to "card+code" each previously entered card will have this 8888 user code as well.
* Incard+code" security level, you must remember to change that code before first use. The 8888 user code does not allow access (see Changing the User Code for an Existing User, pg. 12). There are multiple ways to program proximity cards. Proximity cards may be assigned to User IDs between 0 and 997. When programming cards, use the following general formula after entering base programming mode (see Enter and Exit Base Programming Mode, pg. 7):
SECO-LARM U.S.A., Inc. 9 ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader Programming User Proximity Cards (Continued):
* Additional users may be entered in succession without repeating the function code _1).
* The _*) key returns you to base programming mode (the LED will flash red). Exit programming mode by pressing the +] key (see "Enter and Exit Base Programming Mode," pg. 7). Examples:
1, Program user card for User ID #0:
1) (o) 4) ReadCard 4) 2, Program a user card allowing the device to auto-assign to the first available User ID (not recommended unless you have a complete record of already assigned User IDs):
1) ReadCard _+]
3. Program a batch of 50 cards, starting with card# 23456789 and beginning with user ID #0:
Joo a} sho) a) 2hahs) 5) sz) 2) 5) (or read cardi 23456789) +) NOTE: The add user function code 1) places you into this function programming mode. Press the add user function code only before adding the first user. To continue to add other users in the same session, do not repeat the add user function code 1). Programming User Codes:
User codes may be assigned to User IDs between 0 and 997. Do not use this mathod for adding a user code to an existing card user. Programming User Codes Individually:
When programming user codes, use the following general formula after entering base programming mode (see "Enter and Exit Base Programming Mode," pg. 7):
4) (Al J B)elele) (*)Aftera short beep, you may continue to add users by repeating these steps, but without repeating the function code 1. _J = Add Users function code (a short beep will sound and the LED will change to steady orange) AJ - 9) to (2)/2J_7) - 997 unique User IDs to trigger the device (if 4] _*) is omitted, the device wil assign the user code to the first available User ID)
'8| User code 4~6 digits (do not use the user code 6888) With the Master Add Card:
The Master Add Card allows you to enter codes quickly without entering programming mode. It takes you directly into the add user function mode without needing to enter the master programming code and the _t] add user function code. Once in this mode, you made add codes using the methods described above, but omitting the _1]. When complete, present the Master Add Card again to return to standby mode. NOTES:
* [tis important to record each User ID assigned in order to simplify future user management. Avuser ID can only have a single card or single code assigned (except by using the method described in "Changing the User Code for an Existing User," on pg. 12 when in the "card+code"
security level). If you try to add a user code to an existing user ID that already has a user card assigned, the user card will be removed. SECO-LARM U.S.A, Inc. 11
1 | 06 SK-2612-SPQ LabelSmpl-US | ID Label/Location Info | 83.88 KiB | December 23 2019 |
Label Location On EUT Label Product Name: Outdoor Mullion Stand-alone/Wiegand Proximity Reader Model No.: SK-2612-SPQ FCC ID: K4E2612SPQ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
1 | 17 SK-2612-SPQ AntSpec | Operational Description | 12.75 KiB | December 23 2019 |
Superior Electronics Corporation Declaration concerning Antenna Specification It is hereby declared that the product Model No.: SK-2612-SPQ, PR-3123-PQ, PR-3125-PQ, PR-2121-PQ, PR-2123-PQ, PR-2125-PQ, SK-2612-SDQ, SK-1612-SDQ FCC ID : K4E2612SPQ fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal antenna type(s) described below:
Model No. of antenna: N/A Type of antenna:
Gain of the antenna:
Frequency range:
Loop Antenna 0 dBi 125KHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Superior Electronics Corporation Address: No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110, Taiwan City:
ZIP / Postal code: N/A Country:
Taipei City Taiwan Place:
Taiwan Date: 2019-12-17 Signature:
version01
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-12-23 | 0.125 ~ 0.125 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-12-23
|
||||
1 | Applicant's complete, legal business name |
Superior Electronics Corporation
|
||||
1 | FCC Registration Number (FRN) |
0010373520
|
||||
1 | Physical Address |
No. 10 Lane 31, Chongde St., Sinyi District
|
||||
1 |
Taipei City, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@eurofins.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
K4E
|
||||
1 | Equipment Product Code |
2612SPQ
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S**** L********
|
||||
1 | Title |
Senior Systems Engineer
|
||||
1 | Telephone Number |
886 2********
|
||||
1 | Fax Number |
886 2********
|
||||
1 |
s******@superior-elec.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Outdoor Mullion Stand-alone/Wiegand Proximity Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 | Name |
J******** Z******
|
||||
1 | Telephone Number |
86-75********
|
||||
1 | Fax Number |
86-75********
|
||||
1 |
j******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC