all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 522.92 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | ID Label/Location Info | |||||||
1 |
|
Int Photos | Internal Photos | 1.11 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Setup Photos | |||||||
1 |
|
Test Report | Test Report | 474.90 KiB |
1 | User Manual | Users Manual | 522.92 KiB |
ENFORCER Wireless Help Button Changing the Battery:
The Wireless Help Button has a multi-colored LED that illuminates blue when the button is pressed. When the battery begins to run low, the LED will illuminate red. To change the battery:
1. 2. 3. 4. 5. Troubleshooting:
Remove the two screws from the front of the plate and remove the plate from the back box. Remove the battery clip from the 9V battery and remove the battery from the bracket. Place the new battery in the bracket and snap the battery clip to the new battery. Test the unit with the new battery. The LED should illuminate blue. Put the plate back in the back box and secure it to the back box using the screws on the front. LED does not light LED lights blue, but does not activate lock Also Available from 2-Channel RF Receiver Check battery connection Replace 9V battery Ensure Wireless Help Button is not housed in a metal box Test Wireless Help Button closer to the receiver Clear codes from receiver and re-learn wireless transmitter code
:
1-Button Handheld RF Transmitter Room Monitor Kit SK-910RB2Q SK-919TP1H-BUQ RM-R100-KB1Q IMPORTANT: Users and installers of this product are responsible for ensuring this product complies with all national, state, and local laws and statutes related to monitoring and recording audio and video signals. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or statutes. FCC ID: K4ER100TBQ FCC COMPLIANCE STATEMENT THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void users authority to operate the device. WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARMs obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchasers exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARMs option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else. NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright 2018 SECO-LARM U.S.A., Inc. All rights reserved. RM-R100-TBQ SD-862M-GWSQ Wireless Help Button Manual Features:
Built-in RF transmitter:
ABS Plastic single-gang plate with surface
- Powered by 9VDC (battery included)
- Range up to 250ft (76m)*, 433.92MHz
- Over 68 billion (6.8x1010) possible codes
- LED to indicate transmission and low battery mount back box Clear 2" square button
"Push for Help" message plate included Requires RM-R100-KB1Q, or SK-910 Desktop or wall mounted
*Actual operating range will vary greatly depending on the installation and operating environment.
(433.92MHz) series receiver U.S.A., Inc. 16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com 4 SECO-LARM U.S.A., Inc. PITSW1 Order Part# 763-190%
MI_RM-R100-TBQ_181211.docx ENFORCER Wireless Help Button Introduction:
The ENFORCER Wireless Help Button can be used to wirelessly expand the Room Monitor
(RM-R100-KB1Q) with a service/help button. The button is perfect for placing on a desktop, mounting on walls, or any other location where it is difficult to run wires. The Wireless Help Button combines the very best of SECO-LARM, flexible wireless solutions and reliable access control. Parts List:
1x Wireless Help Button 2x Mounting screws 4x Adhesive rubber feet 1x Back box 2x Wall anchors 1x Manual Specifications:
2x Wall plate screws 1x 9V Alkaline battery Operating frequency Operating voltage Maximum range Battery life Dimensions Desktop Wall mount 433.92MHz 9VDC 250' (76m)*
Up to four (4) years (60 uses per day) 45/8"x27/8"x17/8" (117x73x48 mm) 45/8"x27/8"x2" (117x73x50 mm) Weight
*Actual operating range will vary greatly depending on the installation and operating environment. 6-oz (178g) 9V Alkaline battery Battery clip Request button Push for Help LED Indicator Off: No transmission Blue: Transmitting Red: Low battery ENFORCER Wireless Help Button Installation:
1. 2. 3. Find a suitable location for the Wireless Help Button. NOTE: Do not house in a metal box as this will greatly reduce the range. The Wireless Help Button can either be wall mounted (taller side of back box on bottom), or placed on a desktop (taller side of back box on top). Test the operation of the Wireless Help Button in the location where it will be installed before finalizing the installation. NOTE: The Wireless Help Button needs to be programmed into the RM-R100-RB1Q or a SK-910 (433.92MHz) series receiver before testing. See the receiver manual for transmitter learning procedure. 4. Ensure the battery clip is securely connected, mount the Wireless Help Button in the back box according to the appropriate orientation stated above, and secure it with the two included screws. Apply the included adhesive rubber feet for desktop applications. Changing the Message Plate:
You can easily print your own message plate on very thin card stock, no thicker than the included message plate, and trim to 17/8" (37mm) square. NOTE: Thicker card stock will not allow the transparent lens to fully seat. 1. Use the tip of a very thin screwdriver to pry off the transparent lens over the message plate (see Fig. 1). Replace the current plate with the desired message plate, keeping the spacer plate in place. Check that message plate orientation is correct. Carefully snap the lens assembly back on. 3. 4. RM-R100-TBQ Sample Applications:
Basic Installation with Room Monitor Kit (RM-R100-KB1Q) 2. Fig. 1 Your Custom Message Message Plate Transparent lens Spacer Plate Sensor/Transmitter RM-R100-TLQ Indicator/Receiver RM-R100-RB1Q 1 2 Sensor/Transmitter RM-R100-TLQ Indicator/Receiver RM-R100-RB1Q Light/Buzzer and RF receiver
(not included) 17/8"
(48mm) 17/16"
(36mm) 45/8"
(117mm) Desktop 2"
(50mm) 13/4"
(45mm) 27/8"
(73mm) Wall mount Push for Help 45/8"
(117mm) Wireless Help Button RM-R100-TBQ Room occupied Wireless Help Button RM-R100-TBQ Room occupied indicator/receiver LED is lit. Wireless pushbutton pressed indicator/receiver LED flashes and/or buzzer sounds Attendant uses wireless remote (not included) to reset the indicator flashing LED and/or buzzer. Room occupied remote indicator/receiver LED is lit. Wireless pushbutton pressed light/buzzer connected to a 433.92MHz RF receiver outside door is triggered and remote indicator/receiver LED flashes and/or buzzer sounds Attendant uses wireless pushbutton (or wireless remote, not included) to reset the Indicator flashing LED and/or buzzer. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc. 3 Overview:
Dimensions:
15/16"
(24mm) 2
1 | Int Photos | Internal Photos | 1.11 MiB |
Bay Area Compliance Laboratories Corp.(Taiwan) Project No.: RXZ181204009 EUT Internal Photographs EUT - Uncover View EUT - Uncover View Page 1 of 4 Bay Area Compliance Laboratories Corp.(Taiwan) Project No.: RXZ181204009 Main Board - Top View Main Board - Bottom View Page 2 of 4 Bay Area Compliance Laboratories Corp.(Taiwan) Project No.: RXZ181204009 Antenna View RF Chip IC Page 3 of 4 Bay Area Compliance Laboratories Corp.(Taiwan) Project No.: RXZ181204009 Battery Battery Page 4 of 4
1 | Test Report | Test Report | 474.90 KiB |
FCC Part 15.231 TEST REPORT For Superior Electronics Corporation No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110, Taiwan (R.O.C.) FCC ID: K4ER100TBQ Product Type:
Wireless Help Button Report Type:
Original Report Report Producer : Kaylee Chiang Report Number : RXZ181204009-00 Report Date : 2018-12-21 Reviewed By: Jerry Chang Prepared By: Bay Area Compliance Laboratories Corp.(Taiwan) 70, Lane 169, Sec. 2, Datong Road, Xizhi Dist., New Taipei City 22183, Taiwan, R.O.C. Tel: +886 (2) 2647 6898 Fax: +886 (2) 2647 6895 www.bacl.com.tw Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 1 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Revision History Revision No. Report Number Issue Date Description Author/
Revised by 1.0 RXZ181204009 RXZ181204009-00 2018.12.21 Original Report Kaylee Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 2 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 TABLE OF CONTENTS 2 1.1 1.2 1.3 1.4 1.5 1 General Information ....................................................................................................... 4 Product Description for Equipment under Test (EUT) ......................................................... 4 Objective ............................................................................................................................... 5 Related Submittal(s)/Grant(s) ................................................................................................ 5 Test Methodology.................................................................................................................. 5 Test Facility ........................................................................................................................... 5 System Test Configuration ........................................................................................... 6 Description of Test Configuration ......................................................................................... 6 Equipment Modifications ...................................................................................................... 6 EUT Exercise Software ......................................................................................................... 6 Support Equipment List and Details...................................................................................... 6 External Cable List and Details ............................................................................................. 6 Block Diagram of Test Setup ................................................................................................ 7 3 Summary of Test Results ................................................................................................ 8 2.1 2.2 2.3 2.4 2.5 2.6 4 Test Equipment List and Details ................................................................................... 9 5 5.1 5.2 FCC 15.203 Antenna Requirements ..................................................................... 10 Applicable Standard ............................................................................................................ 10 Antenna Connected Construction ........................................................................................ 10 6 FCC 15.209, 15.205 , 15.231(b) Radiated Emissions ......................................... 11 Applicable Standard ............................................................................................................ 11 6.1 6.2 Measurement Uncertainty ................................................................................................... 12 EUT Setup ........................................................................................................................... 12 6.3 EMI Test Receiver & Spectrum Analyzer Setup................................................................. 13 6.4 6.5 Test Procedure ..................................................................................................................... 13 Corrected Factor & Margin Calculation .............................................................................. 13 6.6 Test Results Summary ......................................................................................................... 13 6.7 Environmental Conditions ................................................................................................... 13 6.8 6.9 Test Results ......................................................................................................................... 14 7 FCC 15.231(a)(1) Deactivation Testing .................................................................. 20 Applicable Standard ............................................................................................................ 20 Test Procedure ..................................................................................................................... 20 Environmental Conditions ................................................................................................... 20 Test Results ......................................................................................................................... 21 8 FCC 15.231(c) 20 dB Emission Bandwidth Testing .............................................. 22 Applicable Standard ............................................................................................................ 22 Test Procedure ..................................................................................................................... 22 Environmental Conditions ................................................................................................... 22 Test Results ......................................................................................................................... 23 8.1 8.2 8.3 8.4 7.1 7.2 7.3 7.4 Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 3 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 1 General Information 1.1 Product Description for Equipment under Test (EUT) Applicant Manufacturer Brand(Trade) Name Product (Equipment) Main Model Name Series Model Name Model Discrepancy Frequency Range Number of Channels Antenna Specification Power Operation
(Voltage Range) Superior Electronics Corporation No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110, Taiwan (R.O.C.) Superior Electronics Corporation No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110, Taiwan (R.O.C.) ENFORCER Wireless Help Button RM-R100-TBQ SD-862M-GWSQ The major electrical and mechanical constructions of series models are identical to the basic model, except different appearance color. The model, RM-R100-TBQ is the testing sample, and the final test data are shown on this test report. 433.92MHz 1 Channel PCB Antenna / -2 dBi AC 120V/60Hz Adapter By AC Power Cord PoE DC Type Battery 9Vdc DC Power Supply External from USB Cable External DC Adapter Host System Dec 04, 2018 Dec 16, 2018 ~ Dec 17, 2018 Received Date Date of Test
*All measurement and test data in this report was gathered from production sample serial number: 181204009
(Assigned by BACL, Taiwan). Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 4 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 1.2 Objective This report is prepared on behalf of Superior Electronics Corporation All the test measurements were performed according to the measurement procedure described in ANSI C63.10 - 2013. The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section 15.203, 15.205, 15.209, 15.35(c) and 15.231 rules. 1.3 Related Submittal(s)/Grant(s) N/A. 1.4 Test Methodology All measurements contained in this report were conducted with ANSI C63.10-2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. 1.5 Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Taiwan) to collect test data is located on 70, Lane 169, Sec. 2, Datong Road, Xizhi Dist., New Taipei City 22183, Taiwan, R.O.C. 68-3, Lane 169, Sec. 2, Datong Road, Xizhi Dist., New Taipei City 22183, Taiwan, R.O.C. Bay Area Compliance Laboratories Corp. (Taiwan) Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code: 3180) and the FCC designation No.TW3180 under the Mutual Recognition Agreement (MRA) in FCC Test. The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.10. The Federal Communications Commission has the reports on file and is listed under FCC Registration No.: 974454. The test site has been approved by the FCC for public use and is listed in the FCC Public Access Link (PAL) database. Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 5 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 2 System Test Configuration 2.1 Description of Test Configuration Channel list:
Channel 1 Frequency
(MHz) 433.92 2.2 Equipment Modifications No modification was made to the EUT. 2.3 EUT Exercise Software No test software was used. 2.4 Support Equipment List and Details Description Manufacturer Model Number BSMI FCC ID N/A N/A N/A N/A N/A 2.5 External Cable List and Details Length (m) Cable Description N/A N/A From N/A S/N N/A To N/A Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 6 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 2.6 Block Diagram of Test Setup See test photographs attached in setup photos for the actual connections between EUT and support equipment. Radiation:
Below 1GHz:
Above 1GHz:
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 7 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 3 Summary of Test Results FCC Rules 15.203 15.207(a) 15.205, 15.209, 15.231(b) 15.231(a)(2) 15.231(c) Not applicable: Device only supports battery. Description of Test Antenna Requirement Conducted Emissions Radiated Emissions Deactivation Deactivation Results Compliance Not applicable Compliance Compliance Compliance Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 8 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 4 Test Equipment List and Details Description Manufacturer Model Serial Number Calibration Date Calibration Due Date Radiated Room (966-A) Bilog Antenna with 6 dB Attenuator SUNOL SCIENCES & MINI-
CIRCUITS JB6/UNAT-6+ A050115/1554 2_01 2017/12/20 2018/12/19 Horn Antenna EMCO Horn Antenna ETS-Lindgren Preamplifier Sonoma 3115 3116 310N 9311-4158 2018/04/20 2019/04/19 62638 2018/08/29 2019/08/28 130602 2018/07/04 2019/07/03 Preamplifier EM Electronics Corp. EM01G18G 060657 2018/12/07 2019/12/06 Microware Preamplifier EM Electronics Corporation EM18G40G 060656 2018/01/15 2019/01/14 EMI Test Receiver Rohde & Schwarz ESR7 101419 2018/10/23 2019/10/22 Spectrum Analyzer Rohde & Schwarz FSV40 101435 2018/02/12 2019/02/13 Micro flex Cable UTIFLEX Micro flex Cable UTIFLEX Micro flex Cable ROSNOL Micro flex Cable ROSNOL FSCM 64639 /
(2M) UFA210A-1-
3149-300300 K1K50-UP0264-
K1K50-450CM K1K50-UP0264-
K1K50-80CM 93D0127 2018/07/31 2019/07/30 MFR64639 226389-001 2018/11/16 2019/11/15 160309-1 2018/03/05 2019/03/04 160309-2 2018/01/17 2019/01/16 Turn Table Champro TT-2000 060772-T Antenna Tower Champro AM-BS-4500-B 060772-A Controller Champro EM1000 60772 N.C.R N.C.R N.C.R Software Farad EZ_EMC BACL-03A1 N.C.R N.C.R N.C.R N.C.R N.C.R
*Statement of Traceability: BACL Corp. attests that all of the calibrations on the equipment items listed above were traceable to the SI System of Units via the R.O.C. Center for Measurement Standards of the Electronics Testing Center, Taiwan (ETC) or to another internationally recognized National Metrology Institute (NMI), and were compliant with the current Taiwan Accreditation Foundation (TAF) requirements Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 9 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 5 FCC 15.203 Antenna Requirements 5.1 Applicable Standard An intentional radiator shall be designed to ensure that no antenna other than that furnished by theresponsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 5.2 Antenna Connected Construction The EUT has a PCB antenna which was permanently attached and the antenna gain is 0dBi; fulfill the requirement of this section. Please refer to EUT photos. Result: Compliant. Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 10 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 6 FCC 15.209, 15.205 , 15.231(b) Radiated Emissions 6.1 Applicable Standard FCC 15.205, 15.209, 15.231 (b) According to FCC 15.231(b), the field strength of emissions from intentional radiators operated under this section shall not exceed the following:
Fundamental frequency
(MHz) Field strength of fundamental
(microvolts/meter) Field strength of spurious emission (microvolts/meter) 40.66 40.70 70 130 130 174 174 260 160 470 Above 470 2250 1250 1250 to 3750 **
3750 3750 to 12500 **
12500 225 125 125 to 375 **
375 375 to 1250 **
1250
(1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges.
(2) Intentional radiators operating under the provisions of this section shall demonstrate compliance with the limits on the field strength of emissions, as shown in the above table, based on the average value of the measured emissions. As an alternative, compliance with the limits in the above table may be based on the use of measurement instrumentation with a CISPR quasi-peak detector. The specific method of measurement employed shall be specified in the application for equipment authorization. If average emission measurements are employed, the provisions in 15.35 for averaging pulsed emissions and for limiting peak emissions apply. Further, compliance with the provisions of 15.205 shall be demonstrated using the measurement instrumentation specified in that section.
(3) The limits on the field strength of the spurious emissions in the above table are based on the fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in 15.209, whichever limit permits a higher field strength. Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 11 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 6.2 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability. Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay Area Compliance Laboratories Corp. (Taiwan) is shown in below table. And the uncertainty will not be taken into consideration for the test data recorded in the report. Frequency 30 MHz~200 MHz 200 MHz~1 GHz 1 GHz~6 GHz 6 GHz~18 GHz 18 GHz~26 GHz 26 GHz~40 GHz 6.3 EUT Setup Below 1 GHz:
Above 1 GHz:
Measurement uncertainty 3.75 dB (k=2, 95% level of confidence) 4.21 dB (k=2, 95% level of confidence) 4.83 dB (k=2, 95% level of confidence) 5.18 dB (k=2, 95% level of confidence) 4.55 dB (k=2, 95% level of confidence) 4.67 dB (k=2, 95% level of confidence) Radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC Part 15.209 and FCC 15.231 Limits. Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 12 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 6.4 EMI Test Receiver & Spectrum Analyzer Setup The system was investigated from 30 MHz to 4 GHz. During the radiated emission test, the EMI test receiver was set with the following configurations measurement method 6.3 in ANSI C63.10. Frequency Range 30-1000 MHz Above 1 GHz RBW 100 kHz 1 MHz VBW 300 kHz 3 MHz Detector PK PK 6.5 Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. 6.6 Corrected Factor & Margin Calculation The Correct Factor is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier Gain from the Meter Reading. The basic equation is as follows:
Correct Factor = Antenna Factor + Cable Loss Amplifier Gain The Margin column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of -7 dB means the emission is 7 dB below the limit. The equation for margin calculation is as follows:
Margin = Result Limit 6.7 Test Results Summary According to the data in the following table, the EUT complied with the FCC 15.209 Limit. 6.8 Environmental Conditions Temperature:
Relative Humidity:
ATM Pressure:
The testing was performed by Tom Hsu on 2018-12-16 ~ 2018-12-17. 1010 hPa 25 55 %
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 13 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 6.9 Test Results Test Mode: Transmitting 30MHz-1GHz (GFSK modulation) (Pre-scan with three orthogonal axis, and worse case as Z axis.) Horizontal 30MHz-1GHz:
1GHz-4GHz:
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 14 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Vertical 30MHz-1GHz:
1GHz-4GHz:
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 15 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Below 1GHz Horizontal Frequency
(MHz) 124.09 200.72
*433.92
*433.92 578.05 650.8 759.44 867.84 867.84 Reading
(dBV) 26.69 24.41 85.83 80.43 28.02 39.31 37.02 51.64 51.98 Vertical Frequency
(MHz) 141.55 201.69 353.01
*433.92
*433.92 650.8 759.44 867.84 867.84 Reading
(dBV) 26.44 24.21 24.28 79.95 74.55 40.11 29.82 38.36 38.7 Correct Factor(dB/m)
-9.21
-8.92
-5.40
-8.04
-3.7
-2.84
-1.51 0.34
-8.04 Correct Factor(dB/m)
-9.51
-9.15
-6.8
-5.40
-8.04
-2.84
-1.51 0.34
-8.04 Result
(dBV/m) 17.48 15.49 80.43 72.39 24.32 36.47 35.51 51.98 43.94 Result
(dBV/m) 16.93 15.06 17.48 74.55 66.51 37.27 28.31 38.7 30.66 Limit
(dBV/m) 43.5 80.83 100.83 80.83 80.83 80.83 80.83 80.83 60.83 Limit
(dBV/m) 80.83 80.83 80.83 100.83 80.83 80.83 80.83 80.83 60.83 Margin Height
(cm) 100 100 242 242 100 100 100 100 100
(dB)
-26.02
-65.34
-20.4
-8.44
-56.51
-44.36
-45.32
-28.85
-16.89 Margin Height
(cm) 100 100 100 233 233 100 100 100 100
(dB)
-63.9
-65.77
-63.35
-26.28
-14.32
-43.56
-52.52
-42.13
-30.17 Degree Remark
( ) 234 115 11 11 227 172 360 7 7
( ) 311 311 96 264 264 262 306 223 223 QP QP Peak Ave QP QP QP Peak Ave QP QP QP Peak Ave QP QP Peak Ave Degree Remark Note 1:
Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) Amplifier Factor (dB) Margin (dB) = Result (dBV /m) Limit (dBV/m) Note 2:
Calculate Average value based on Duty Cycle correction factor:
Tp = 52.403ms Ton = Burst1*N1 + Burst2*N2 = 0.671*21 + 0.333*20 = 14.091 + 6.66 = 20.751ms Duty Cycle Corrected Factor = 20*log(Ton/Tp) = 20*log(20.751ms/52.403ms) = -8.04dB Average value = Peak value + Duty Cycle Corrected Factor Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 16 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Above 1GHz Horizontal Frequency
(MHz) 1301.760 1301.760 1735.680 1735.680 2169.600 2169.600 2603.520 2603.520 Reading
(dBV) 71.92 63.74 56.72 50.52 51.99 47.55 64.26 60.97 Vertical Frequency
(MHz) 1301.760 1301.760 1735.680 1735.680 2169.600 2169.600 2603.520 2603.520 Reading
(dBV) 67.94 59.76 59.81 53.61 48.89 44.45 50.26 46.97 Correct Factor(dB/m)
-8.18
-8.04
-6.20
-8.04
-4.44
-8.04
-3.29
-8.04 Correct Factor(dB/m)
-8.18
-8.04
-6.20
-8.04
-4.44
-8.04
-3.29
-8.04 Result
(dBV/m) 63.74 55.70 50.52 42.48 47.55 39.51 60.97 52.93 Result
(dBV/m) 59.76 51.72 53.61 45.57 44.45 36.41 46.97 38.93 Limit
(dBV/m) 80.83 60.83 80.83 60.83 80.83 60.83 80.83 60.83 Limit
(dBV/m) 80.83 60.83 80.83 60.83 80.83 60.83 80.83 60.83 Margin Height
(cm) 219 219 146 146 112 112 139 139
(dB)
-17.09
-5.13
-30.31
-18.35
-33.28
-21.32
-19.86
-7.90 Margin Height
(cm) 214 214 215 215 100 100 100 100
(dB)
-21.07
-9.11
-27.12
-15.26
-36.38
-24.42
-33.86
-21.90 Degree Remark
( ) 61 61 82 82 199 199 16 16
( ) 140 140 346 346 90 90 20 20 peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG Degree Remark Note 1:
Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) Amplifier Factor (dB) Margin (dB) = Result (dBV /m) Limit (dBV/m) Note 2:
Calculate Average value based on Duty Cycle correction factor:
Tp = 52.403ms Ton = Burst1*N1 + Burst2*N2 = 0.671*21 + 0.333*20 = 14.091 + 6.66 = 20.751ms Duty Cycle Corrected Factor = 20*log(Ton/Tp) = 20*log(20.751ms/52.403ms) = -8.04dB Average value = Peak value + Duty Cycle Corrected Factor Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 17 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Duty Cycle Tp=52.403ms RBW 100 kHz
*
VBW 300 kHz SWT 300 ms
*
Att 10 dB 1 1 2 Delta 2 [T1 ]
0.59 dB 52.403846 ms Marker 1 [T1 ]
-28.89 dBm 107.211538 ms Delta 1 [T1 ]
0.38 dB 41.346154 ms Ref 0 dBm 0 1 PK
*
CLRWR
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100 Center 433.92 MHz 30 ms/
Date: 16.DEC.2018 16:32:57 Zoom in N1=21, N2=20
*
Att 10 dB RBW 100 kHz
*
VBW 300 kHz SWT 50 ms Delta 1 [T1 ]
0.39 dB 40.865385 ms Marker 1 [T1 ]
-33.51 dBm 2.804487 ms 1 Ref 0 dBm 0 1 PK
*
CLRWR
-10
-20
-30 1
-40
-50
-60
-70
-80
-90
-100 Center 433.92 MHz 5 ms/
Date: 16.DEC.2018 16:34:06 A SGL 3DB A SGL 3DB Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 18 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 Duty Cycle Burst 1 Ref 0 dBm 0
*
Att 10 dB RBW 100 kHz
*
VBW 300 kHz SWT 3 ms 1 1 1 PK
*
CLRWR
-10
-20
-30
-40
-50
-60
-70
-80
-90 Delta 1 [T1 ]
0.36 dB 671.474359 s Marker 1 [T1 ]
-31.60 dBm 1.160256 ms A SGL 3DB
-100 Center 433.92 MHz 300 s/
Date: 16.DEC.2018 16:35:50 Duty Cycle Burst 2 Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 19 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 7 FCC 15.231(a)(1) Deactivation Testing 7.1 Applicable Standard Per FCC 15.231(a) (1), A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released 7.2 Test Procedure 1. With the EUTs antenna attached, the waveform was received by the test antenna which was connected to the spectrum analyzer. 2. Set center frequency of spectrum analyzer=operating frequency. 3. Set the spectrum analyzer as RBW=100k VBW=300k Span=0Hz. 4. Repeat above procedures until all frequency measured was complete. 7.3 Environmental Conditions Temperature:
Relative Humidity:
ATM Pressure:
The testing was performed by Tom Hsu on 2018-12-16. 1010 hPa 25 55 %
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 20 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 7.4 Test Results Test mode: Transmitting GFSK Modulation 5s RBW 100 kHz
*
VBW 300 kHz SWT 10 s Delta 1 [T1 ]
-55.76 dB 5.000000 s Marker 1 [T1 ]
-22.08 dBm 1.282051 s A SGL 3DB 1 Ref 0 dBm 0
*
Att 10 dB 1 1 PK
*
CLRWR
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100 Center 433.92 MHz 1 s/
Date: 16.DEC.2018 16:50:55 Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 21 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 8 FCC 15.231(c) 20 dB Emission Bandwidth Testing 8.1 Applicable Standard Per 15.231(c), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down from the modulated carrier. 8.2 Test Procedure With the EUTs antenna attached, the waveform was received by the test antenna which was connected to the spectrum analyzer, plot the 20 dB bandwidth. 8.3 Environmental Conditions Temperature:
Relative Humidity:
ATM Pressure:
The testing was performed by Tom Hsu on 2018-12-16. 1010 hPa 25 55 %
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 22 of 23 Bay Area Compliance Laboratories Corp.(Taiwan) No.: RXZ181204009-00 8.4 Test Results Frequency
(MHz) 433.92 20 dB Emission Bandwidth
(kHz) 48.718 Limit
(kHz) 1085 Result Compliance Note: Limit = 0.25% * Center Frequency = 0.25% * 433.92 MHz = 1085 kHz 20 dB Emission Bandwidth Ref 0 dBm 0
*
Att 10 dB
*
RBW 10 kHz
*
VBW 30 kHz SWT 10 ms Marker 1 [T1 ]
-28.09 dBm 433.977692308 MHz ndB [T1] 20.00 dB BW 48.717948718 kHz Temp 1 [T1 ndB]
-48.14 dBm 433.954294872 MHz Temp 2 [T1 ndB]
-48.18 dBm 434.003012821 MHz 1 T1 T2 A 3DB 1 PK MAXH
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100 Center 433.92 MHz 20 kHz/
Span 200 kHz Date: 16.DEC.2018 16:45:02
***** END OF REPORT *****
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan) Page 23 of 23
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-01-18 | 433.92 ~ 433.92 | DSC - Part 15 Security/Remote Control Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-01-18
|
||||
1 | Applicant's complete, legal business name |
Superior Electronics Corporation
|
||||
1 | FCC Registration Number (FRN) |
0010373520
|
||||
1 | Physical Address |
No. 10 Lane 31, Chongde St., Sinyi District
|
||||
1 |
Taipei City, N/A 110
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@baclcorp.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
K4E
|
||||
1 | Equipment Product Code |
R100TBQ
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S****** L********
|
||||
1 | Title |
Senior Systems Engineer
|
||||
1 | Telephone Number |
886 2********
|
||||
1 | Fax Number |
886 2********
|
||||
1 |
s******@superior-elec.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSC - Part 15 Security/Remote Control Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Help Button | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bay Area Compliance Laboratories Corp. (Taiwan)
|
||||
1 | Name |
j****** c********
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
j******@baclcorp.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231 | 433.92000000 | 433.92000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC